Ebadullah Asadi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ebadullah Asadi has a total of 47 co-authors. Here are the top co-authors by number of shared publications:
- Majid Abdouss
Department of Chemistry, Amirkabir University of Technology, Tehran, Iran
3 shared publications - Sina Farzaneh
Young Researchers and Elite Club, South Tehran Branch, Islamic Azad University, Tehran, Iran
2 shared publications Ajit Kumar Meikap
1 shared publicationAlexei Kuznetsov
1 shared publicationAlireza Hassani Najafabadi
Department of Chemistry, Amirkabir University of Technology, Tehran, Iran
1 shared publicationAntti Nykänen
1 shared publication
Latest Publications
- 1 January 2018
- Published by Elsevier
List of Contributors
- 5 January 2015
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 7 (4) , 1280-1292
Determination of meloxicam in plasma samples using a highly selective and sensitive voltammetric sensor based on carbon paste electrodes modified by molecularly imprinted polymer nanoparticle–multiwall carbon nanotubes
In this study, a highly selective voltammetric sensor is introduced for the monitoring of meloxicam by using a new carbon paste electrode (CPE). A meloxicam molecularly imprinted polymer (MIP) and a non-imprinted polymer (NIP), polymerizing on the surface of functionalized multiwall carbon nanotubes (MWCNTs), were synthesized and then used for the preparation of carbon paste electrodes (CPEs) to improve the selectivity and conductivity of the prepared sensor. The sensor was applied for the determination of meloxicam using the cathodic stripping voltammetric method. The MIP@MWCNT–CP electrode showed higher recognition ability in comparison to the NIP@MWCNT–CP. Some parameters affecting the sensor response were optimized and then the calibration curve was plotted. Under optimized conditions, two linear dynamic ranges from 4.33 × 10−5 to 2.85 × 10−3 mg L−1 and 2.85 × 10−3 to 7.53 × 10−2 mg L−1 were obtained. The detection limit and quantitation limit of the sensor were calculated to be 3.22 × 10−5 and 1.1 × 10−4 mg L−1, respectively, which indicated the sensitivity of the proposed procedure. The proposed sensor is applied to determine meloxicam in plasma samples and the recovery results were found to be between 98.0 and 102.5% using the voltammetric method with acceptable precision of less than 3.1%.
- 5 January 2015
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 7 (4) , 1280-1292
Determination of meloxicam in plasma samples using a highly selective and sensitive voltammetric sensor based on carbon paste electrodes modified by molecularly imprinted polymer nanoparticle–multiwall carbon nanotubes
In this study, a highly selective voltammetric sensor is introduced for the monitoring of meloxicam by using a new carbon paste electrode (CPE). A meloxicam molecularly imprinted polymer (MIP) and a non-imprinted polymer (NIP), polymerizing on the surface of functionalized multiwall carbon nanotubes (MWCNTs), were synthesized and then used for the preparation of carbon paste electrodes (CPEs) to improve the selectivity and conductivity of the prepared sensor. The sensor was applied for the determination of meloxicam using the cathodic stripping voltammetric method. The MIP@MWCNT–CP electrode showed higher recognition ability in comparison to the NIP@MWCNT–CP. Some parameters affecting the sensor response were optimized and then the calibration curve was plotted. Under optimized conditions, two linear dynamic ranges from 4.33 × 10−5 to 2.85 × 10−3 mg L−1 and 2.85 × 10−3 to 7.53 × 10−2 mg L−1 were obtained. The detection limit and quantitation limit of the sensor were calculated to be 3.22 × 10−5 and 1.1 × 10−4 mg L−1, respectively, which indicated the sensitivity of the proposed procedure. The proposed sensor is applied to determine meloxicam in plasma samples and the recovery results were found to be between 98.0 and 102.5% using the voltammetric method with acceptable precision of less than 3.1%.
- 27 November 2014
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 5 (12) , 9154-9166
Molecularly imprinted polymer nanoparticles for olanzapine recognition: application for solid phase extraction and sustained release
Recently, scientists have drawn more attention to polymeric nanoparticles as potential drug carriers. In this study, we synthesized high selective imprinted polymer nanoparticles using olanzapine as the template. The aim of this study was to prepare efficient imprinted polymer nanoparticles from an olanzapine template for the controlled release of olanzapine as a therapeutic drug for central nervous system (CNS) diseases at different pH values, and solid-phase extraction (SPE) as the sample clean-up technique combined with high-performance liquid chromatography (HPLC). The morphology of the nanoparticles was determined using scanning electron microscopy (SEM) images. Drug release, binding properties and dynamic light scattering (DLS) of the molecularly imprinted polymers (MIPs) were studied in this investigation. The adsorption isotherm was fitted with Langmuir and Freundlich models. The performance of the MIPs for the controlled release of olanzapine was assessed in two different media (SDS 1% and PBS). Results revealed that the MIPs have potential application in controlled drug release. Moreover, cytotoxicity of the MIP nanoparticles was measured on a NIH/3T3 cell line using a MTT method. Furthermore, the MIPs were applied to extract olanzapine from human blood plasma samples. The limit of detection (LOD) and limit of quantification (LOQ) were evaluated and were 0.18 μg L−1 and 0.39 μg L−1, respectively. These results collectively illustrate that MIP nanoparticles can be employed as an efficient technique for the extraction of the olanzapine from human plasma.
- 27 November 2014
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 5 (12) , 9154-9166
Molecularly imprinted polymer nanoparticles for olanzapine recognition: application for solid phase extraction and sustained release
Recently, scientists have drawn more attention to polymeric nanoparticles as potential drug carriers. In this study, we synthesized high selective imprinted polymer nanoparticles using olanzapine as the template. The aim of this study was to prepare efficient imprinted polymer nanoparticles from an olanzapine template for the controlled release of olanzapine as a therapeutic drug for central nervous system (CNS) diseases at different pH values, and solid-phase extraction (SPE) as the sample clean-up technique combined with high-performance liquid chromatography (HPLC). The morphology of the nanoparticles was determined using scanning electron microscopy (SEM) images. Drug release, binding properties and dynamic light scattering (DLS) of the molecularly imprinted polymers (MIPs) were studied in this investigation. The adsorption isotherm was fitted with Langmuir and Freundlich models. The performance of the MIPs for the controlled release of olanzapine was assessed in two different media (SDS 1% and PBS). Results revealed that the MIPs have potential application in controlled drug release. Moreover, cytotoxicity of the MIP nanoparticles was measured on a NIH/3T3 cell line using a MTT method. Furthermore, the MIPs were applied to extract olanzapine from human blood plasma samples. The limit of detection (LOD) and limit of quantification (LOQ) were evaluated and were 0.18 μg L−1 and 0.39 μg L−1, respectively. These results collectively illustrate that MIP nanoparticles can be employed as an efficient technique for the extraction of the olanzapine from human plasma.