JAJun Arimoto

Jun Arimoto

*This is an algorithmically generated author record based on publicly available information.

Jun Arimoto has a total of 67 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Unexpected aortic proximity after endoscopic hand suturing for gastric tube: importance of preoperative anatomical assessment

    by Ai Hirohata, Mikio Kobayashi, Akimichi Hayashi, Yu Ebisawa, Jun Arimoto, Hirohiko Kitakawa, Hideyuki Chiba


  • Open Access

    Endoscopic submucosal dissection with a traction-guided rendezvous approach for sigmoid colon cancer in the distal limb of a double-barrel colostomy

    by Akimichi Hayashi, Hideyuki Chiba, Ai Hirohata, Toshifumi Iida, Yu Ebisawa, Jun Arimoto, Michiko Nakaoka

  • Open Access

    Hemostasis achieved with new self-assembling peptide hemostatic gel for a bleeding duodenal diverticulum

    by Yu Ebisawa, Hideyuki Chiba, Akimichi Hayashi, Mikio Kobayashi, Jun Arimoto, Hiroki Kuwabara, Michiko Nakaoka


  • Open Access

    Outcomes in colorectal endoscopic submucosal dissection for large protruded lesions: A retrospective multicenter study

    by Hideyuki Chiba, Ken Ohata, Akimichi Hayashi, Yu Ebisawa, Mikio Kobayashi, Jun Arimoto, Hiroki Kuwabara, Yohei Minato, Michiko Nakaoka

    Background and study aims Colorectal endoscopic submucosal dissection (ESD) is increasingly used for treating early-stage colorectal cancer, including large, protruded lesions (LPL). However, the challenges posed by LPLs, especially those accompanied by severe fibrosis or muscle-retracting sign (MRS), remain unclear. This study aims to investigate ESD outcomes for LPL, focusing on factors such as tumor size and, submucosal fibrosis. Patients and methods In a multicenter retrospective study (June 2012 to May 2023), data from 526 patients with 542 LPL lesions (≥ 2 cm) were analyzed. Parameters included lesion size, procedure time, dissection speed, physician experience, submucosal fibrosis, and adverse events. The tunnel method, including the double tunnel method, was used for cases with severe fibrosis or MRS. Multivariate analysis assessed factors affecting procedure difficulty, particularly LPLs ≥ 4 cm. Results The study revealed an impressive en bloc resection rate of 97.8% and a curative resection rate of 78.6% for LPLs. Notably, fibrosis and MRS were present in 25% and 18% of 4-cm LPLs, respectively, and their frequency tended to increase as the tumor diameter increased. One treatment strategy for LPLs was the tunneling method, which was used most frequently (41 cases, 7.6%). Factors affecting dissection speed included larger tumor size, submucosal fibrosis, MRS, and physician experience. Conclusions Treating LPLs through colorectal ESD presents significant challenges, especially in patients with fibrosis and MRS. This study highlights the importance of recognizing these complexities, and that more reliable resection strategy must be established for accurate pathological evaluation


  • Cold snare defect protrusion and incomplete polyp resection after forced cold snare polypectomy: a prospective observational study

    by Jun Arimoto, Hideyuki Chiba, Keiji Yamada, Takanori Nishiguchi, Mikio Kobayashi, Naoya Okada, Takuma Suto, Toshihiro Niikura, Hiroki Kuwabara, Michiko Nakaoka, et al.

    Background Cold snare defect protrusions (CSDPs) that occur after cold snare polypectomy (CSP) are considered indicators of incomplete polyp resection (IPR). We have sometimes experienced difficulty resecting polyps with snaring alone; in such cases, a forcible pull on the snare by the endoscopist is necessary. We call this procedure “forced CSP (FCSP).” However, no previous studies have evaluated this procedure. Methods This was a prospective observational study. From November 2020 to June 2021, the frequency, safety, and validity of FCSP were evaluated at our hospital. We distinguished CSP with snaring alone performed by the assistant as conventional CSP, and CSP requiring a forcible pull on the snare by the endoscopist as FCSP. Results Of 1315 polyps removed, 105 underwent FCSP (8%). The perforation rate was 0% in both groups. The rate of CSDP after the procedure was 96.2% (101/105) with FCSP and 6.4% (77/1210) with conventional CSP (P<0.001). The rate of IPR was 12.5% (13/104) with FCSP and 6.2% (75/1208) with conventional CSP (P=0.02). Multivariable analysis identified polyps located in the cecum (risk ratio [RR], 1.13; 95%CI 1.050–1.179; P=0.003) and polyps ≥6mm in diameter (RR, 2.37; 95%CI 2.146–2.542; P<0.001) as independent risk factors for FCSP. Conclusions FCSP was performed on 105 polyps (8%) in this study. FCSP may be associated with the occurrence of CSDP and IPR. Further studies are necessary to confirm our results.


  • Open Access

    Successful mucosal closure of artificial gastric ulcer with twin grasping forceps and endoclips after endoscopic submucosal dissection

    by Michiko Nakaoka, Hideyuki Chiba, Keiji Yamada, Naoya Okada, Jun Arimoto, Hiroki Kuwabara, Toru Goto

    The risk of postoperative adverse events following endoscopic resection can be reduced through endoscopic closure of the artificial gastric ulcer [1], but it is not easy owing to the gastric wall thickness and hardness. There are several methods for closing ulcers induced by gastric endoscopic submucosal dissection (ESD) [2] [3] [4] [5]. Here, we describe the successful simple closure of a post-gastric ESD artificial ulcer using twin grasping forceps (Twin Grasper; Ovesco Endoscopy AG, Tubingen, Germany) and endoclips (EZ clip; Olympus, Tokyo, Japan). An 89-year-old man with early gastric cancer (upper part of the gastric greater curvature) underwent ESD that resulted in a mucosal defect (artificial gastric ulcer, diameter 20 mm) ([Fig. 1], [Fig. 2]) that was subsequently closed as follows ([Video 1]). Video 1 Twin grasping forceps and endoclips used for successful mucosal closure of artificial gastric ulcer after endoscopic submucosal dissection. (1) A double-channel endoscope (GIF-2TQ260M; Olympus) was inserted to visualize the mucosal defect in a straight view. (2) A Twin Grasper was inserted through the first channel and rotated. One arm grasped the edge of the ulcer, then the other arm grasped opposite edge, and the two sides of the ulcer contacted completely ([Fig. 3]). (3) An EZ clip inserted through the second channel was rotated into an appropriate position and the sheath of the Twin Grasper was drawn to pull both of the grasped edges of the ulcer into the crotch of the clip, where they were closed ([Fig. 4]). (4) These steps were repeated until the defect was completely closed (procedure duration 11.7 min) ([Fig. 5]). The patient was discharged 5 days after ESD without adverse events. The advantage of the abovementioned Twin Grasper and EZ clip-based mucosal defect closure method is that the Twin Grasper enables the apposition of ulcer edges as though undertaken manually and facilitates defect closure under direct visualization. Therefore, this easy closure method will be one of the effective and safe options for closing a post-ESD artificial gastric ulcer. Endoscopy_UCTN_Code_CPL_1AJ_2AD Publication Date: 21 December 2021 (online) © 2021. Thieme. All rights reserved. Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany

  • Evaluation of cold snare polypectomy for small pedunculated (Ip) polyps with thin stalks: a prospective clinical feasibility study

    by Jun Arimoto, Hideyuki Chiba, Jun Tachikawa, Kenji Yamaoka, Dai Yamazaki, Airi Higa, Naoya Okada, Takuma Suto, Naoya Kawano, Toshihiro Niikura, et al.

    Although the use of cold snare polypectomy (CSP) has spread rapidly, no prospective studies evaluating the safety of CSP for pedunculated (Ip) polyps have been carried out.We performed this study t...


  • Management of Less Than 10-mm-Sized Pedunculated (Ip) Polyps with Thin Stalk: Hot Snare Polypectomy Versus Cold Snare Polypectomy

    by Jun Arimoto, Hideyuki Chiba, Keiichi Ashikari, Ryo Fukui, Jun Tachikawa, Naoya Okada, Takuma Suto, Naoya Kawano, Toshihiro Niikura, Hiroki Kuwabara, et al.

    Background Although the use of cold snare polypectomy (CSP) has spread rapidly, its safety for pedunculated (Ip) polyps remains controversial. In particular, the outcomes of hot snare polypectomy (HSP) and CSP for Ip polyps have not been previously compared. Aims This study evaluated whether the rate of delayed postpolypectomy bleeding (DPPB) after CSP for Ip polyps was higher than that after HSP for Ip polyps and compared other outcomes (the rates of immediate bleeding and pathological margins) between the HSP and CSP procedures. Methods A total of 5905 colorectal polyps in 4920 patients were resected at Omori Red Cross Hospital between October 2012 and June 2019. The polyps were divided into two groups: the HSP group (86 polyps, 64 patients) and the CSP group (102 polyps, 87 patients). The primary outcome measure was the incidence of DPPB. The secondary outcome measures were the incidences of immediate bleeding during the procedure and pathological margins of the resected specimen. Results The rate of immediate bleeding during CSP was significantly higher than that for the HSP group [38.2% (39/102) versus 3.5% (3/86); p < 0.001]. However, the rate of DPPB was significantly higher in the HSP group than in the CSP group [4.7% (4/86) versus 0% (0/102); p < 0.001]. The rate of DPPB after CSP was 0%. Conclusions This is the first study to compare the outcomes of HSP and CSP for Ip polyps. CSP is safer than HSP for Ip polyps measuring < 10 mm in diameter.


  • Tu1252 - Western Diet Increases Risk of Aspirin Induced small Bowel Injury in Mice

    by Tsutomu Yoshihara, Noboru Misawa, Jun Arimoto, Takayuki Kato, Kenji Kanoshima, Akiko Fuyuki, Hidenori Ohkubo, Takuma Higurashi, Takaomi Kessoku, Atsushi Nakajima

  • Su1656 The Analysis of Recurrence Rate After Colorectal Emr: Is Incomplete Polyp Resection Really a Clinical Important Problem?

    by Jun Arimoto, Takuma Higurashi, Akiko Fuyuki, Hidenori Ohkubo, Takashi Nonaka, Atsushi Nakajima