JRJalil Ur Rehman

Jalil Ur Rehman

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Jalil Ur Rehman has a total of 27 co-authors. Here are the top co-authors by number of shared publications:

  • Iftikhar Alam

    Department of Physics, Islamia University of Bahawalpur, Bahawalpur, Pakistan

    4 shared publications
  • Nisar Ahmad

    Department of Physics , Balochistan University of Information Technology, Engineering and Management Sciences , Quetta , Pakistan

    4 shared publications
  • Alia Nazir

    Department of Physics, Islamia University of Bahawalpur, Bahawalpur, Pakistan

    3 shared publications
  • Altaf Hussain

    Department of Physics, Islamia University of Bahawalpur, Bahawalpur, Pakistan

    3 shared publications
  • Aslam Hameed

    Department of Physics, Islamia University of Bahawalpur, Bahawalpur, Pakistan

    3 shared publications
  • Muhammad Isa

    Department of Physics, Hafiz Hayat Campus University of Gujrat, Gujrat, Pakistan

    3 shared publications

Latest Publications

  • Assessment of health hazards related to contaminations of fluorides, nitrates, and nitrites in drinking water of Vehari, Punjab, Pakistan

    by Aslam Hameed, Saima Nazir, Jalil Ur Rehman, Nisar Ahmad, Altaf Hussain, Iftikhar Alam, Alia Nazir, M. Bilal Tahir

    The high concentration of fluorides, nitrates, and nitrites in water causes methemoglobinemia and gastrointestinal cancer. The purpose of this research is to investigate the physiochemical analysis and concentration of fluoride, nitrate, and nitrite with interconnected health hazards due to potable water. The potable water samples were collected from 48 different rural and urban areas of district Vehari, Pakistan. The concentration of fluoride, nitrate, and nitrite are 0.29–0.86, 0–14.086, and 0–0.005 mg/L, respectively. Nitrate at one place is reported 14.086 mg/L which is much higher than other area reports. The findings of this study indicate that concentrations of fluoride, nitrate, and nitrites are less than WHO guidelines. The chronic daily intake (mg/kg/day) and hazard quotient calculated by concentration are also in safe limits, so this region is on the safe side concerning health hazards.


  • An overview on radiometric assessment and excess lifetime cancer risk of soil in Pakistan by using High Purity Germanium (HPGe) detector

    by Jalil Ur Rehman, Iftikhar Alam, Nisar Ahmad, Aslam Hameed, Alia Nazir, Hafeez Ullah, Altaf Hussain

    Objectives: The aim of this study is to compare the natural radioactivity and excess life time cancer risk (ELCR) factor of soil in different regions of Pakistan during last decade. Soil contains various elements and compounds including naturally occurring radioactive elements (U-238, Th-232, K-40 and Cs-137). Human being, animals and plants are in health risk by contaminations of natural radioactivity in soil and environmental radiometric pollution. Transferring of large amount of the natural radioactive elements in human body by nutrients may cause carcinogenic effects in human body. Pakistani soil has six types as Indus Basin Soil, Bongar Soil, Khaddar Soil, Indus delta soil, Mountainous soil and Sandy Desert Soil. In some northern region of Pakistan, naturally occurring radioactive rocks like uranuium-238 and iridium concentrations present in Gharwandi, Aram, Kingri S, Vitakri Fort Munro, Dera Bugti, Kohlu and Sibbi districts. Methods: In this reviewed data, gamma rays spectroscopy used to determine the concentrations of U-238, Th-232 and K-40 with the help of High Purity Germanium (HPGe) detectors. Only the data of HPGe detector collected because of comparisons of different regions of Pakistan. Results and conclusions: Mostly, different gamma rays energy peaks of relevant daughter radionuclides of radioactive element were used such as the energy peak lines of daughter radionuclides Pb-214 (295.21 and 352 KeV) and Bi-214 (609 and 1,120 KeV) used for calculating the Ra-226 concentration in soil. In the recent study, it is concluded that average values of concentrations of natural radioactivity in soil in central and north regions of Pakistan are higher than permissible limit but found permissible range in south region of Pakistan. Mean values of ELCR factor were found higher, equal and lower in central, north and south regions than permissible limit, respectively. Generally, no serious health hazard due to natural radioactivity in soil were found.


  • Health Risks in Different Age Group of Nitrate in Spring Water Used for Drinking in Harnai, Balochistan, Pakistan

    by Jalil Ur Rehman, Nisar Ahmad, Niamt Ullah, Iftikhar Alam, Hamid Ullah

    This study aims to determine the nitrate exposure and their health assessment in spring water used for drinking in Harnai. Total 24 water samples were collected from four springs used for drinking. Three samples from starting point and three from the end point of each spring were collected. DR/890 multi-parameter portable calorimeter was used for the measurement of nitrate. The concentration of nitrate was ranged from 0.1 to 1.1 mg/l with an average of 0.389 mg/l. The results show that the concentration of nitrate in spring water is 93%, and 99% less than permissible limits recommended by Pakistan Standards & Quality Control Authority (PSQCA) and World Health Organization (WHO), respectively. The values of physiochemical parameters like potential of Hydrogen (pH), Electrical Conductivity (EC) and Total Dissolved Solid (TDS) were ranged from 7.8 to 8.3, 564 to 749 µS/cm, and 36 to 479 mg/l with average values 8.025, 630.5 µS/cm, and 403.5 mg/l, respectively. The calculated mean chronic daily intake (CDI) in three age groups was found 0.01, 0.02, and 0.03 in adults, children, and infants, respectively. Hence, it is concluded that spring water used for drinking in Harnai was considered safe and do not pose any health hazards associated with nitrate.


  • An overview on the concentration of radioactive elements and physiochemical analysis of soil and water in Iraq

    by Iftikhar Alam, Jalil Ur Rehman, Nisar Ahmad, Alia Nazir, Aslam Hameed, Altaf Hussain

    In the last decade, radiation physics brought about a revolution in health science by improving scientific equipment and useful methodologies for measurement. Human beings are affected by ionizing radiations that radiate from radioactive elements. The quantity of radioactive elements is different inside and outside the earth’s surface. Soil and water are exigencies of human lives which are contaminated by radioactive elements. These radioactive elements enter into the human body through drinking, eating and breathing. On reaching hazardous limits in the human body, these radioactive elements cause stomach cancer, lung cancer and leukemia. Measurement of radioactive elements in soil and water is helpful in monitoring the health issues caused by exposure to these elements. In Iraq, numerous studies about natural radioactivity, radon concentration and physiochemical parameters have been conducted by different researchers, of which most of the studies were conducted in Barsa, Nasirya, Najaf, Karbala, Baghdad, Balad, Kirkuk, Erbil, Mosul and Dohuk cities. This article aims to review and compile the studies conducted in these cities of Iraq from 2011 to 2019. In most articles, high-purity germanium (HPGe), RAD7 and CR-39 detectors are used for radioactivity and radon measurement. These cities are located in the low-high folded and Mesopotamian zones. From this study, it can be concluded that radon concentration in soil and water was greater in the Mesopotamian and lower in the low-high folded zones. Higher concentrations of natural radioactivity in water and soil were found in the low-high folded zone in Iraq. However, most of the conducted studies show that concentrations of radon and natural radioactivity are above the permissible limits recommended by the International Commission on Radiological Protection (ICRP) and World Health Organization (WHO). The values of physiochemical parameters were found to be greater in the Mesopotamian zone, but overall they are not above the permissible limits.


  • Quality assurance of intensity modulated radiation therapy treatment planning using head and neck phantom

    by Zahra, Jalil Ur Rehman, H M Noor Ul Huda Khan Asghar, Nisar Ahmad, Zaheer Abbas Gilani, Gulfam Nasar, Malik M Akhter

    Purpose: The purpose of this study is the verification of intensity modulated radiation therapy (IMRT) head neck treatment planning with one-dimensional and two-dimensional (2D) dosimeters using imaging and radiation oncology core (IROC) Houston head & neck (H&N) phantom.Method: The image of the H&N phantom was obtained by computed tomography scan which was then transferred to Pinnacle@3 treatment planning system (TPS) for treatment planning. The contouring of the target volumes and critical organ were done manually and dose constraints were set for each organ according to IROC prescription. The plan was optimised by adoptive convolution algorithm to meet the IROC criteria and collapse cone convolution algorithm calculated the delivered doses for treatment. Varian Clinac 2110 was used to deliver the treatment plan to the phantom, the process of irradiation and measurement were repeated three times for reproducibility and reliability. The treatment plan was verified by measuring the doses from thermoluminescent dosimeters (TLDs) and GafChromic external beam therapy 2 films. The agreement between the planned and delivered doses were checked by calculating the percentage dose differences, analysing their isodose line profiles and 2D gamma maps.Results: The average percent dose difference of 1·8% was obtained between computed doses by TPS and measured doses from TLDs, however these differences were found to be higher for organ at risk. The film dose profile was well in agreement with the planned dose distribution with distance to agreement of 1·5 mm. The gamma analysis of the computed and recorded doses passed the criteria of 3%/3 mm with passing percentages of >96%, which shows successful authentication of delivered doses for IMRT.Conclusion: IMRT pre-treatment validation can be done with IROC anthropomorphic phantoms, which is essential for the delivery of modulated radiotherapies. It was concluded that films and TLDs can be used as quality assurance tools for IMRT.


  • Dose verification of volumetric-modulated arc therapy using one-dimensional and two-dimensional dosimeters

    by Jalil Ur Rehman, Zahra Syed, Ghulam Hussain, Nisar Ahmad, H M Noor Ul Huda Khan Asghar, Zaheer Abbas Gilani, Gulfam Nasar, Malik M Akhter, Muhammad Isa, Tahir Iqbal

    PurposeTo verify dose delivery and quality assurance of volumetric-modulated arc therapy (VMAT) for head and neck (H&N) cancer.MethodThe Imaging and Radiation Oncology Core Houston (IROC-H) H&N phantom with thermoluminescent dosimeters (TLDs) and films, were imaged with computed tomography scan and the reconstructed image was transferred to pinnacle treatment planning system (TPS). On TPS, the planning target volume (PTV), secondary target volume (STV) and organ at risk (OAR) were delineated manually and a treatment plan was made. The dose constraints were determined for the concerned organs according to IROC-H prescription. The treatment plan was optimised using adoptive convolution algorithm to improve dose homogeneity and conformity. The dose calculation was performed using C.C Convolution algorithm and a Varian True Beam linear accelerator was used to deliver the treatment plan to the H&N phantom. The delivered radiation dose to the phantom was measured through TLDs and GafChromic external beam radiotherapy 2 (EBT2) films. The dosimetric performance of the VMAT delivery was studied by analysing percent dose difference, isodose line profile and gamma analysis of the TPS-computed dose and linac-delivered doses.ResultThe percent dose difference of 3.8% was observed between the planned and measured doses of TLDs and a 1.5-mm distance to agreement (DTA) was observed by comparing isodose line profiles. Passed the gamma criteria of 3%/3 mm was with good percentages.ConclusionThe dosimetric performance of VMAT delivery for a challenging H&N radiotherapy can be verified using TLDs and films embedded in an anthropomorphic H&N phantom.

  • Quality assurance of volumetric-modulated arc therapy head and neck cancer treatment using PRESAGE® dosimeter

    by Jalil Ur Rehman, Muhammad Isa, Nisar Ahmad, H. M. Noor Ul Huda Khan Asghar, Zaheer A. Gilani, James C. L. Chow, Muhammad Afzal, Geoffrey S. Ibbott

    BackgroundAccurate three-dimensional dosimetry is essential in modern radiotherapy techniques such as volumetric-modulated arc therapy (VMAT) and intensity-modulated radiation therapy (IMRT). In this research work, the PRESAGE® dosimeter was used as quality assurance (QA) tool for VMAT planning for head and neck (H&N) cancer.Material and methodComputer tomography (CT) scans of an Image Radiation Oncology Core (IROC) H&N anthropomorphic phantom with both IROC standard insert and PRESAGE® insert were acquired separately. Both CT scans were imported into the Pinnacle (9.4 version) TPS for treatment planning, where the structures [planning target volume (PTV), organs at risk) and thermoluminescent detectors (TLDs) were manually contoured and used to optimise a VMAT plan. Treatment planning was done using VMAT (dual arc: 182°–178°, 178°–182°). Beam profile comparisons and gamma analysis were used to quantify agreement with film, PRESAGE® measurement and treatment planning system (TPS) calculated dose distribution.ResultsThe average ratio of TLD measured to calculated doses at the four PTV locations in the H&N phantom were between 0·95 to 0·99 for all three VMAT deliveries. Dose profiles were taken along the left–right, the anterior–posterior and superior–inferior axes, and good agreement was found between the PRESAGE® and Pinnacle profile. The mean value of gamma results for three VMAT deliveries in axial and sagittal planes were found to be 94·24 and 93·16% when compared with film and Pinnacle, respectively. The average values comparing the PRESAGE® results and dose values calculated on Pinnacle were observed to be 95·29 and 94·38% in the said planes, respectively, using a 5%/3 mm gamma criteria.ConclusionThe PRESAGE® dose measurements and calculated dose of pinnacle show reasonable agreement in both axial and sagittal planes for complex dual arc VMAT treatment plans. In general, the PRESAGE® dosimeter is found to be a feasible QA tool of VMAT plan for H&N cancer treatment.


  • Evaluations of secondary cancer risk in spine radiotherapy using 3DCRT, IMRT, and VMAT: A phantom study

    by Jalil Ur Rehman, Ramesh C. Tailor, Muhammad Isa, Muhammad Afzal, James Chow, Geoffrey S. Ibbott