Xavier Helluy
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Xavier Helluy has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Peter Michael Jakob
Experimental Physics 5 University of Würzburg Würzburg Germany
2 shared publications - Christian Herbert Ziener
Department of Radiology, German Cancer Research Center (DKFZ), Heidelberg, Germany
1 shared publication - Christoph Kleinschnitz
Department of Neurology, University Hospital Essen, Essen, Germany
1 shared publication Cord B. Meyer
Universität Würzburg, Lehrstuhl für Experimentelle Physik 5, Am Hubland, 97074, Würzburg, Germany
1 shared publicationFabian T. Gutjahr
Universität Würzburg, Lehrstuhl für Experimentelle Physik 5, Am Hubland, 97074, Würzburg, Germany
1 shared publication- Guido Stoll
Department of Neurology, University of Würzburg, Würzburg, Germany
1 shared publication
Latest Publications
- Open Access
- 1 December 2014
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 74 (6) , 1705-1715
Quantification of perfusion in murine myocardium: A retrospectively triggeredT1-based ASL method using model-based reconstruction
Purpose A method for the quantification of perfusion in murine myocardium is demonstrated. The method allows for the reconstruction of perfusion maps on arbitrary time points in the heart cycle while addressing problems that arise due to the irregular heart beat of mice. Methods A flow-sensitive alternating inversion recovery arterial spin labeling method using an untriggered FLASH-read out with random sampling is used. Look-Locker conditions are strictly maintained. No dummy pulses or mechanism to reduce deviation from Look-Locker conditions are needed. Electrocardiogram and respiratory data are recorded for retrospective gating and triggering. A model-based technique is used to reconstruct missing k-space data to cope with the undersampling inherent in retrospectively gated methods. Acquisition and reconstruction were validated numerically and in phantom measurements before in vivo experimentation. Results Quantitative perfusion maps were acquired within a single slice measurement time of 11 min. Perfusion values are in good accordance to literature values. Myocardial infarction could be clearly visualized and results were confirmed with histological results. Conclusion The proposed method is capable of producing quantitative perfusion maps on arbitrary positions in the heart cycle within a short measurement time. The method is robust against irregular breathing patterns and heart rate changes and can be implemented on all scanners. Magn Reson Med 74:1705–1715, 2015.
- 1 December 2014
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 74 (6) , 1705-1715
Open AccessQuantification of perfusion in murine myocardium: A retrospectively triggeredT1-based ASL method using model-based reconstruction
Purpose A method for the quantification of perfusion in murine myocardium is demonstrated. The method allows for the reconstruction of perfusion maps on arbitrary time points in the heart cycle while addressing problems that arise due to the irregular heart beat of mice. Methods A flow-sensitive alternating inversion recovery arterial spin labeling method using an untriggered FLASH-read out with random sampling is used. Look-Locker conditions are strictly maintained. No dummy pulses or mechanism to reduce deviation from Look-Locker conditions are needed. Electrocardiogram and respiratory data are recorded for retrospective gating and triggering. A model-based technique is used to reconstruct missing k-space data to cope with the undersampling inherent in retrospectively gated methods. Acquisition and reconstruction were validated numerically and in phantom measurements before in vivo experimentation. Results Quantitative perfusion maps were acquired within a single slice measurement time of 11 min. Perfusion values are in good accordance to literature values. Myocardial infarction could be clearly visualized and results were confirmed with histological results. Conclusion The proposed method is capable of producing quantitative perfusion maps on arbitrary positions in the heart cycle within a short measurement time. The method is robust against irregular breathing patterns and heart rate changes and can be implemented on all scanners. Magn Reson Med 74:1705–1715, 2015.
- Open Access
- 15 March 2010
- Published by Springer Nature in Experimental & Translational Stroke Medicine
- Vol. 2 (1) , 6
Outcome of experimental stroke in C57Bl/6 and Sv/129 mice assessed by multimodal ultra-high field MRI
Transgenic mice bred on C57Bl/6 or Sv/129 genetic background are frequently used in stroke research. It is well established that variations in cerebrovascular anatomy and hemodynamics can influence stroke outcome in different inbred mouse lines. We compared stroke development in C57Bl/6 and Sv/129 mice in the widely used model of transient middle cerebral artery occlusion (tMCAO) by multimodal ultra-high field magnetic resonance imaging (MRI). C57Bl/6 and Sv/129 mice underwent 60 min of tMCAO and were analyzed by MRI 2 h and 24 h afterwards. Structural and functional images were registered to a standard anatomical template. Probability maps of infarction were rendered by automated segmentation from quantitative T2-relaxometric images. Whole-brain segmentation of infarction was accomplished manually on high-resolution T2-weighted (T2-w) RARE images. Cerebral perfusion (cerebral blood flow, CBF) was measured quantitatively by modified continuous arterial-spin-labeling (CASL) and apparent diffusion coefficients (ADC) by spin-echo diffusion-weighted imaging (DWI). Probabilities of cortical (95.1% ± 3.1 vs. 92.1% ± 2.5; p > 0.05) and subcortical (100% vs. 100%; p > 0.05) infarctions at 24 h were similar in both groups as was the whole-brain volumetric extent of cerebral infarction. In addition, CBF and ADC values did not differ between C57Bl/6 and Sv/129 mice at any time point or region of interest. The C57Bl/6 and Sv/129 genetic background is no major confounding factor of infarct size and cerebral perfusion in the tMCAO model.
- 15 March 2010
- Published by Springer Nature in Experimental & Translational Stroke Medicine
- Vol. 2 (1) , 6
Open AccessOutcome of experimental stroke in C57Bl/6 and Sv/129 mice assessed by multimodal ultra-high field MRI
Transgenic mice bred on C57Bl/6 or Sv/129 genetic background are frequently used in stroke research. It is well established that variations in cerebrovascular anatomy and hemodynamics can influence stroke outcome in different inbred mouse lines. We compared stroke development in C57Bl/6 and Sv/129 mice in the widely used model of transient middle cerebral artery occlusion (tMCAO) by multimodal ultra-high field magnetic resonance imaging (MRI). C57Bl/6 and Sv/129 mice underwent 60 min of tMCAO and were analyzed by MRI 2 h and 24 h afterwards. Structural and functional images were registered to a standard anatomical template. Probability maps of infarction were rendered by automated segmentation from quantitative T2-relaxometric images. Whole-brain segmentation of infarction was accomplished manually on high-resolution T2-weighted (T2-w) RARE images. Cerebral perfusion (cerebral blood flow, CBF) was measured quantitatively by modified continuous arterial-spin-labeling (CASL) and apparent diffusion coefficients (ADC) by spin-echo diffusion-weighted imaging (DWI). Probabilities of cortical (95.1% ± 3.1 vs. 92.1% ± 2.5; p > 0.05) and subcortical (100% vs. 100%; p > 0.05) infarctions at 24 h were similar in both groups as was the whole-brain volumetric extent of cerebral infarction. In addition, CBF and ADC values did not differ between C57Bl/6 and Sv/129 mice at any time point or region of interest. The C57Bl/6 and Sv/129 genetic background is no major confounding factor of infarct size and cerebral perfusion in the tMCAO model.