Austin Reiter
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Austin Reiter has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Ayushi Sinha
The Johns Hopkins University
3 shared publications - Gregory D. Hager
Johns Hopkins University, Baltimore, MD, 21211, USA
3 shared publications - Russell H. Taylor
Department of Computer Science, Johns Hopkins University
2 shared publications - Tae Soo Kim
Johns Hopkins University Baltimore MD
2 shared publications Andy Ma
The Johns Hopkins University
1 shared publicationChristine Shrock
Johns Hopkins Medical Institutions
1 shared publication
Latest Publications
- Open Access
Dense Depth Estimation in Monocular Endoscopy with Self-supervised Learning Methods
We present a self-supervised approach to training convolutional neural networks for dense depth estimation from monocular endoscopy data without a priori modeling of anatomy or shading. Our method only requires monocular endoscopic videos and a multi-view stereo method, e.g., structure from motion, to supervise learning in a sparse manner. Consequently, our method requires neither manual labeling nor patient computed tomography (CT) scan in the training and application phases. In a cross-patient experiment using CT scans as groundtruth, the proposed method achieved submillimeter mean residual error. In a comparison study to recent self-supervised depth estimation methods designed for natural video on in vivo sinus endoscopy data, we demonstrate that the proposed approach outperforms the previous methods by a large margin. The source code for this work is publicly available online at https://github.com/lppllppl920/EndoscopyDepthEstimation-Pytorch.
Open AccessDense Depth Estimation in Monocular Endoscopy with Self-supervised Learning Methods
We present a self-supervised approach to training convolutional neural networks for dense depth estimation from monocular endoscopy data without a priori modeling of anatomy or shading. Our method only requires monocular endoscopic videos and a multi-view stereo method, e.g., structure from motion, to supervise learning in a sparse manner. Consequently, our method requires neither manual labeling nor patient computed tomography (CT) scan in the training and application phases. In a cross-patient experiment using CT scans as groundtruth, the proposed method achieved submillimeter mean residual error. In a comparison study to recent self-supervised depth estimation methods designed for natural video on in vivo sinus endoscopy data, we demonstrate that the proposed approach outperforms the previous methods by a large margin. The source code for this work is publicly available online at https://github.com/lppllppl920/EndoscopyDepthEstimation-Pytorch.
- Open Access
Train, Diagnose and Fix: Interpretable Approach for Fine-grained Action Recognition
Despite the growing discriminative capabilities of modern deep learning methods for recognition tasks, the inner workings of the state-of-art models still remain mostly black-boxes. In this paper, we propose a systematic interpretation of model parameters and hidden representations of Residual Temporal Convolutional Networks (Res-TCN) for action recognition in time-series data. We also propose a Feature Map Decoder as part of the interpretation analysis, which outputs a representation of model's hidden variables in the same domain as the input. Such analysis empowers us to expose model's characteristic learning patterns in an interpretable way. For example, through the diagnosis analysis, we discovered that our model has learned to achieve view-point invariance by implicitly learning to perform rotational normalization of the input to a more discriminative view. Based on the findings from the model interpretation analysis, we propose a targeted refinement technique, which can generalize to various other recognition models. The proposed work introduces a three-stage paradigm for model learning: training, interpretable diagnosis and targeted refinement. We validate our approach on skeleton based 3D human action recognition benchmark of NTU RGB+D. We show that the proposed workflow is an effective model learning strategy and the resulting Multi-stream Residual Temporal Convolutional Network (MS-Res-TCN) achieves the state-of-the-art performance on NTU RGB+D.
Open AccessTrain, Diagnose and Fix: Interpretable Approach for Fine-grained Action Recognition
Despite the growing discriminative capabilities of modern deep learning methods for recognition tasks, the inner workings of the state-of-art models still remain mostly black-boxes. In this paper, we propose a systematic interpretation of model parameters and hidden representations of Residual Temporal Convolutional Networks (Res-TCN) for action recognition in time-series data. We also propose a Feature Map Decoder as part of the interpretation analysis, which outputs a representation of model's hidden variables in the same domain as the input. Such analysis empowers us to expose model's characteristic learning patterns in an interpretable way. For example, through the diagnosis analysis, we discovered that our model has learned to achieve view-point invariance by implicitly learning to perform rotational normalization of the input to a more discriminative view. Based on the findings from the model interpretation analysis, we propose a targeted refinement technique, which can generalize to various other recognition models. The proposed work introduces a three-stage paradigm for model learning: training, interpretable diagnosis and targeted refinement. We validate our approach on skeleton based 3D human action recognition benchmark of NTU RGB+D. We show that the proposed workflow is an effective model learning strategy and the resulting Multi-stream Residual Temporal Convolutional Network (MS-Res-TCN) achieves the state-of-the-art performance on NTU RGB+D.
- Open Access
Interpretable 3D Human Action Analysis with Temporal Convolutional Networks
The discriminative power of modern deep learning models for 3D human action recognition is growing ever so potent. In conjunction with the recent resurgence of 3D human action representation with 3D skeletons, the quality and the pace of recent progress have been significant. However, the inner workings of state-of-the-art learning based methods in 3D human action recognition still remain mostly black-box. In this work, we propose to use a new class of models known as Temporal Convolutional Neural Networks (TCN) for 3D human action recognition. Compared to popular LSTM-based Recurrent Neural Network models, given interpretable input such as 3D skeletons, TCN provides us a way to explicitly learn readily interpretable spatio-temporal representations for 3D human action recognition. We provide our strategy in re-designing the TCN with interpretability in mind and how such characteristics of the model is leveraged to construct a powerful 3D activity recognition method. Through this work, we wish to take a step towards a spatio-temporal model that is easier to understand, explain and interpret. The resulting model, Res-TCN, achieves state-of-the-art results on the largest 3D human action recognition dataset, NTU-RGBD.
Open AccessInterpretable 3D Human Action Analysis with Temporal Convolutional Networks
The discriminative power of modern deep learning models for 3D human action recognition is growing ever so potent. In conjunction with the recent resurgence of 3D human action representation with 3D skeletons, the quality and the pace of recent progress have been significant. However, the inner workings of state-of-the-art learning based methods in 3D human action recognition still remain mostly black-box. In this work, we propose to use a new class of models known as Temporal Convolutional Neural Networks (TCN) for 3D human action recognition. Compared to popular LSTM-based Recurrent Neural Network models, given interpretable input such as 3D skeletons, TCN provides us a way to explicitly learn readily interpretable spatio-temporal representations for 3D human action recognition. We provide our strategy in re-designing the TCN with interpretability in mind and how such characteristics of the model is leveraged to construct a powerful 3D activity recognition method. Through this work, we wish to take a step towards a spatio-temporal model that is easier to understand, explain and interpret. The resulting model, Res-TCN, achieves state-of-the-art results on the largest 3D human action recognition dataset, NTU-RGBD.
- 2 October 2016
- Published by Springer Nature
- Vol. 9900, 482-490
Process Monitoring in the Intensive Care Unit: Assessing Patient Mobility Through Activity Analysis with a Non-Invasive Mobility Sensor
Throughout a patient’s stay in the Intensive Care Unit (ICU), accurate measurement of patient mobility, as part of routine care, is helpful in understanding the harmful effects of bedrest [ 1 ]. However, mobility is typically measured through observation by a trained and dedicated observer, which is extremely limiting. In this work, we present a video-based automated mobility measurement system called NIMS: Non-Invasive Mobility Sensor. Our main contributions are: (1) a novel multi-person tracking methodology designed for complex environments with occlusion and pose variations, and (2) an application of human-activity attributes in a clinical setting. We demonstrate NIMS on data collected from an active patient room in an adult ICU and show a high inter-rater reliability using a weighted Kappa statistic of 0.86 for automatic prediction of the highest level of patient mobility as compared to clinical experts.
- 2 October 2016
- Published by Springer Nature
- Vol. 9900, 482-490
Process Monitoring in the Intensive Care Unit: Assessing Patient Mobility Through Activity Analysis with a Non-Invasive Mobility Sensor
Throughout a patient’s stay in the Intensive Care Unit (ICU), accurate measurement of patient mobility, as part of routine care, is helpful in understanding the harmful effects of bedrest [ 1 ]. However, mobility is typically measured through observation by a trained and dedicated observer, which is extremely limiting. In this work, we present a video-based automated mobility measurement system called NIMS: Non-Invasive Mobility Sensor. Our main contributions are: (1) a novel multi-person tracking methodology designed for complex environments with occlusion and pose variations, and (2) an application of human-activity attributes in a clinical setting. We demonstrate NIMS on data collected from an active patient room in an adult ICU and show a high inter-rater reliability using a weighted Kappa statistic of 0.86 for automatic prediction of the highest level of patient mobility as compared to clinical experts.
- 21 March 2016
- Published by SPIE-Intl Soc Optical Eng in Proceedings of SPIE
- Vol. 9784, 978418
Endoscopic-CT: learning-based photometric reconstruction for endoscopic sinus surgery
In this work we present a method for dense reconstruction of anatomical structures using white light endoscopic imagery based on a learning process that estimates a mapping between light reflectance and surface geometry. Our method is unique in that few unrealistic assumptions are considered (i.e., we do not assume a Lambertian reflectance model nor do we assume a point light source) and we learn a model on a per-patient basis, thus increasing the accuracy and extensibility to different endoscopic sequences. The proposed method assumes accurate video-CT registration through a combination of Structure-from-Motion (SfM) and Trimmed-ICP, and then uses the registered 3D structure and motion to generate training data with which to learn a multivariate regression of observed pixel values to known 3D surface geometry. We demonstrate with a non-linear regression technique using a neural network towards estimating depth images and surface normal maps, resulting in high-resolution spatial 3D reconstructions to an average error of 0.53mm (on the low side, when anatomy matches the CT precisely) to 1.12mm (on the high side, when the presence of liquids causes scene geometry that is not present in the CT for evaluation). Our results are exhibited on patient data and validated with associated CT scans. In total, we processed 206 total endoscopic images from patient data, where each image yields approximately 1 million reconstructed 3D points per image.
- 21 March 2016
- Published by SPIE-Intl Soc Optical Eng in Proceedings of SPIE
- Vol. 9784, 978418
Endoscopic-CT: learning-based photometric reconstruction for endoscopic sinus surgery
In this work we present a method for dense reconstruction of anatomical structures using white light endoscopic imagery based on a learning process that estimates a mapping between light reflectance and surface geometry. Our method is unique in that few unrealistic assumptions are considered (i.e., we do not assume a Lambertian reflectance model nor do we assume a point light source) and we learn a model on a per-patient basis, thus increasing the accuracy and extensibility to different endoscopic sequences. The proposed method assumes accurate video-CT registration through a combination of Structure-from-Motion (SfM) and Trimmed-ICP, and then uses the registered 3D structure and motion to generate training data with which to learn a multivariate regression of observed pixel values to known 3D surface geometry. We demonstrate with a non-linear regression technique using a neural network towards estimating depth images and surface normal maps, resulting in high-resolution spatial 3D reconstructions to an average error of 0.53mm (on the low side, when anatomy matches the CT precisely) to 1.12mm (on the high side, when the presence of liquids causes scene geometry that is not present in the CT for evaluation). Our results are exhibited on patient data and validated with associated CT scans. In total, we processed 206 total endoscopic images from patient data, where each image yields approximately 1 million reconstructed 3D points per image.
- Open Access
- 21 March 2016
- Published by SPIE-Intl Soc Optical Eng
- Vol. 9784, 97840D
Automatic segmentation and statistical shape modeling of the paranasal sinuses to estimate natural variations
We present an automatic segmentation and statistical shape modeling system for the paranasal sinuses which allows us to locate structures in and around the sinuses, as well as to observe the variability in these structures. This system involves deformably registering a given patient image to a manually segmented template image, and using the resulting deformation field to transfer labels from the template to the patient image. We use 3D snake splines to correct errors in this initial segmentation. Once we have several accurately segmented images, we build statistical shape models to observe the population mean and variance for each structure. These shape models are useful to us in several ways. Regular registration methods are insufficient to accurately register pre-operative computed tomography (CT) images with intra-operative endoscopy video of the sinuses. This is because of deformations that occur in structures containing erectile tissue. Our aim is to estimate these deformations using our shape models in order to improve video-CT registration, as well as to distinguish normal variations in anatomy from abnormal variations, and automatically detect and stage pathology. We can also compare the mean shapes and variances in different populations, such as different genders or ethnicities, in order to observe differences and similarities, as well as in different age groups in order to observe the developmental changes that occur in the sinuses.
- 21 March 2016
- Published by SPIE-Intl Soc Optical Eng
- Vol. 9784, 97840D
Open AccessAutomatic segmentation and statistical shape modeling of the paranasal sinuses to estimate natural variations
We present an automatic segmentation and statistical shape modeling system for the paranasal sinuses which allows us to locate structures in and around the sinuses, as well as to observe the variability in these structures. This system involves deformably registering a given patient image to a manually segmented template image, and using the resulting deformation field to transfer labels from the template to the patient image. We use 3D snake splines to correct errors in this initial segmentation. Once we have several accurately segmented images, we build statistical shape models to observe the population mean and variance for each structure. These shape models are useful to us in several ways. Regular registration methods are insufficient to accurately register pre-operative computed tomography (CT) images with intra-operative endoscopy video of the sinuses. This is because of deformations that occur in structures containing erectile tissue. Our aim is to estimate these deformations using our shape models in order to improve video-CT registration, as well as to distinguish normal variations in anatomy from abnormal variations, and automatically detect and stage pathology. We can also compare the mean shapes and variances in different populations, such as different genders or ethnicities, in order to observe differences and similarities, as well as in different age groups in order to observe the developmental changes that occur in the sinuses.
- 23 November 2014
- Published by Springer Nature
- Vol. 8899, 88-98
Is Multi-model Feature Matching Better for Endoscopic Motion Estimation?
Camera motion estimation is a standard yet critical step to endoscopic visualization. It is affected by the variation of locations and correspondences of features detected in 2D images. Feature detectors and descriptors vary, though one of the most widely used remains SIFT. Practitioners usually also adopt its feature matching strategy, which defines inliers as the feature pairs subjecting to a global affine transformation. However, for endoscopic videos, we are curious if it is more suitable to cluster features into multiple groups. We can still enforce the same transformation as in SIFT within each group. Such a multi-model idea has been recently examined in the Multi-Affine work, which outperforms Lowe’s SIFT in terms of re-projection error on minimally invasive endoscopic images with manually labelled ground-truth matches of SIFT features. Since their difference lies in matching, the accuracy gain of estimated motion is attributed to the holistic Multi-Affine feature matching algorithm. But, more concretely, the matching criterion and point searching can be the same as those built in SIFT. We argue that the real variation is only the motion model verification. We either enforce a single global motion model or employ a group of multiple local ones. In this paper, we investigate how sensitive the estimated motion is affected by the number of motion models assumed in feature matching. While the sensitivity can be analytically evaluated, we present an empirical analysis in a leaving-one-out cross validation setting without requiring labels of ground-truth matches. Then, the sensitivity is characterized by the variance of a sequence of motion estimates. We present a series of quantitative comparison such as accuracy and variance between Multi-Affine motion models and the global affine model.
- 23 November 2014
- Published by Springer Nature
- Vol. 8899, 88-98
Is Multi-model Feature Matching Better for Endoscopic Motion Estimation?
Camera motion estimation is a standard yet critical step to endoscopic visualization. It is affected by the variation of locations and correspondences of features detected in 2D images. Feature detectors and descriptors vary, though one of the most widely used remains SIFT. Practitioners usually also adopt its feature matching strategy, which defines inliers as the feature pairs subjecting to a global affine transformation. However, for endoscopic videos, we are curious if it is more suitable to cluster features into multiple groups. We can still enforce the same transformation as in SIFT within each group. Such a multi-model idea has been recently examined in the Multi-Affine work, which outperforms Lowe’s SIFT in terms of re-projection error on minimally invasive endoscopic images with manually labelled ground-truth matches of SIFT features. Since their difference lies in matching, the accuracy gain of estimated motion is attributed to the holistic Multi-Affine feature matching algorithm. But, more concretely, the matching criterion and point searching can be the same as those built in SIFT. We argue that the real variation is only the motion model verification. We either enforce a single global motion model or employ a group of multiple local ones. In this paper, we investigate how sensitive the estimated motion is affected by the number of motion models assumed in feature matching. While the sensitivity can be analytically evaluated, we present an empirical analysis in a leaving-one-out cross validation setting without requiring labels of ground-truth matches. Then, the sensitivity is characterized by the variance of a sequence of motion estimates. We present a series of quantitative comparison such as accuracy and variance between Multi-Affine motion models and the global affine model.