CLCai-Yi Lu

Cai-Yi Lu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Cai-Yi Lu has a total of 40 co-authors. Here are the top co-authors by number of shared publications:

  • Yu-Xiao Zhang

    Institute of Geriatric Cardiology, Chinese People's Liberation Army General Hospital, Beijing 100853, China

    4 shared publications
  • Jie Yang

    Department of Cardiology, Institute of Geriatric Cardiology, General Hospital of Chinese People's Liberation Army, Beijing 100853, China

    3 shared publications
  • Qiang Xu

    Department of Cardiology, Institute of Geriatric Cardiology, General Hospital of Chinese People's Liberation Army, Beijing 100853, China

    3 shared publications
  • Qiao Xue

    Department of Cardiology, First Medical Center of Chinese PLA General Hospital, Beijing 100853, China

    3 shared publications
  • Tong Yin

    Institute of Geriatrics, National Clinical Research Center for Geriatric Diseases, The Second Medical Center of Chinese PLA General Hospital, 100853 Beijing, China

    3 shared publications
  • Yuxiao Zhang

    Department of Cardiology, Institute of Geriatric Cardiology, General Hospital of Chinese People's Liberation Army, Beijing 100853, China

    3 shared publications

Latest Publications

  • Joint effects of CYP2C19*2 and smoking status on clopidogrel responsiveness in patients with acute coronary syndrome

    by Li Peng, Lanning Zhang, Jie Yang, Xuyun Wang, Xiaoqi Li, Wenjie Guo, Yuxiao Zhang, Qiang Xu, Caiyi Lu, Tong Yin


  • Open Access

    COMPARATIVE PERFORMANCE OF GENE-BASED WARFARIN DOSING ALGORITHMS IN CHINESE PATIENTS

    by Tong Yin, Qiang Xu, Yu Liu, Hongjuan Wang, Jie Yang, Lei Gao, Yuxiao Zhang, Bin Xu, Caiyi Lu, Yusheng Zhao

    Objectives Multiple warfarin pharmacogenetic algorithms have been published and been confirmed to predict warfarin dose more accurately than clinical algorithm or fixed-dose approach. However, their performance in Chinese patients has never been evaluated. We sought to compare the performance of published warfarin pharmacogenetic algorithms in a cohort of Chinese patients under warfarin anticoagulation. Methods The study population consisted of 282 unrelated Han-Chinese patients consecutively admitted to the General Hospital of Chinese People's Liberation Army between January 2008 and July 2011. The patients had all undergone warfarin anticoagulation for various indications and were stably controlled with a target international normalisation ratio (INR) of 1.6–2.5. Genomic DNA extraction from each patient was followed by genotyping to detect the polymorphisms of CYP2C9*3 (rs1057910), VKORC1 −1639 G/A (rs9923231), and CYP4F2*3 (rs2108622) respectively, using standard techniques. A total of 8 eligible pharmacogenetic algorithms were selected for performance comparison. The performance of each algorithm was evaluated by calculating the percentage of patients whose predicted dose fell within 20% of their actual therapeutic dose (percentage within 20%), and the mean absolute error (MAE) between each predicted dose and actual stable dose. Results In the entire cohort, the pharmacogenetic algorithms could predict warfarin dose with the average MAE of 0.87±0.17 mg/day (0.73–1.17 mg/day), and the average percentage within 20% of 43.8%±8.1% (29.1–52.1%). By pair wise comparison, warfarin dose prediction was significantly more accurate with the algorithms derived from Asian patients (48.6–50.0%) than those from Caucasian patients (29.1–39.7%; OR 1.61–3.36, p≤0.02). Algorithms with additional covariates of INR values or CYP4F2*3 performed better than those without the covariates (adding INR: OR: 1.71 (1.08–2.72), p=0.029; adding CYP4F2*3: OR: 2.67 (1.41–5.05), p=0.004). When the patients were stratified according to the dose range, the algorithms from Caucasian and racially mixed populations tended to perform better in higher dose group (≥4.5 mg/day), and algorithms from Asian populations performed better in intermediate dose group (1.5–4.5 mg/day). None of the algorithms performed well in lower dose group (≤1.5 mg/day). Conclusions Our study indicated that none of the eligible pharmacogenetic algorithms could perform the best for all dosing ranges in the present cohort of Chinese patients under warfarin anticoagulation. It may be important to consider the ethnic and clinical specific characteristics when choosing the appropriate algorithm for a local service population. A more refinement pharmacogenetic algorithm combining 3 genotypes (CYP2C9, VKORC1 and CYP4F2) and clinical factors with INR response could potentially improve the warfarin dose prediction in Chinese patients.

  • Open Access

    HIGH PRESSURE POST-DILATION IMPROVES IMPLANTATION QUALITY OF DRUG ELUTING STENTS

    by Caiyi Lu, Yuxiao Zhang, Shenhua Zhou, Liping Ding, Wei Yan, Ran Zhang, Ya Huang, Qiang Xu, Yanming Chen

    Objectives Effect of high pressure post-dilation on implantation quality of drug eluting stents was evaluated by optical coherence tomography (OCT). Methods Consecutive patients with acute coronary syndrome and type A lesion in left anterior descending coronary artery (LAD) were enrolled into the study. The nominate pressure of preloaded balloon was used to delivery sirolimus eluting stents. OCT was used then to obtain following parameters: 1. stent apposition rate (SAR). 2. minimal lumen diameter (MLD). 3. minimal lumen area (MLA). 4. maximal distance of strut to endovasculum (DSEmax). 5. apposition strut per centimetre (AS/cm). 6. mean distance of apposition strut to endovasculum (MDASE). Finally, non-compliant high pressure balloons were adapted to dilate the implanted stents with 18 atm and OCT studies were repeated. Results Sixteen patients (male 9, 62.34±7.15 years) were enrolled into the study. Total 16 sirolimus eluting stents were implanted in LAD without death and complications. Mean stent length and diameter was 19.75±9.61 mm and 3.14±0.56 mm respectively. Comparison between OCT parameters before and after high pressure post-dilation was shown in table. Nominate pressure dilation High pressure post-dilation p value SAR 13/16 (81.25) 1/16 (6.25) Conclusions Stent apposition rate was 81.25% if nominate pressure was adapted to delivery drug eluting stent in type A lesion of LAD. This rate could be decreased 92.31% by post-dilation of 18 atm with non-compliant balloon.

    • 1 January 2012
      • Vol. 125  (1) , 16-20

    Radiofrequency catheter ablation of atrioventricular nodal reentrant tachycardia guided by magnetic navigation system: a prospective randomized comparison with conventional procedure.

    by Yu-Xiao Zhang, Cai-Yi Lu, Qiao Xue, Ke Li, Wei Yan, Sheng-Hua Zhou

    Atrioventricular nodal reentrant tachycardia (AVNRT) is one of the most common paroxysmal supraventricular tachyarrhythmias. The aim of the study was to prospectively compare the characteristics of radiofrequency catheter ablation of AVNRT guided by a magnetic navigation system with the conventional procedure. Patients with AVNRT diagnosed by electrophysiological tests were randomized into two groups. In the conventional technique group (CMT), a common 4-mm-tip quadrapolar temperature-controlled ablation catheter was used. In the magnetic navigation system guidance group (MNS), a magnetic 4-mm-tip quadrapolar temperature-controlled ablation catheter was used. The following parameters were collected and compared between the two groups: ablation procedure time, patient fluoroscopy time, operator fluoroscopy time, energy delivery numbers, maximal energy per deployment, success rate, complication rate and operative cost. Forty patients were enrolled and randomized into CMT and MNS groups. The age, gender, tachycardia history and basic cardiovascular diseases of the two groups were comparable (P > 0.05). All procedures were conducted successfully without complications. No tachycardia recurred during the follow-up period of (9.3 ± 2.6) months. In the MNS group, the patient and operator fluoroscopy times ((11.5 ± 4.3) min, (4.2 ± 1.5) min), energy delivery numbers (3.2 ± 0.9), and maximal energy per deployment ((16.9 ± 3.4) W) were shorter or lower than those of the CMT group ((14.3 ± 6.2) min, (13.6 ± 3.5) min, 6.3 ± 2.1, (23.7 ± 1.3) W, respectively) (P < 0.05). But the operative cost for the MNS group was higher than that of the CMT group (P < 0.01). Magnetic navigation system guided radiofrequency catheter ablation of AVNRT has the advantages of shorter fluoroscopy time and lower energy delivery numbers and maximal energy per deployment compared to the present conventional ablation technique.


    • 1 December 2011
      • Vol. 23  (12) , 727-30

    [Tirofiban improved the prognosis of senior acute coronary syndrome patients received percutaneous coronary intervention].

    by Yu-Xiao Zhang, Cai-Yi Lu, Sheng-Hua Zhou, Qiao Xue, Lei Gao, Jin-Wen Tian, Wei Gao, Rui Chen, Jin-Yue Zhai, Li-Jun Li

    To examine if tirofiban may improve the prognosis in aged acute coronary syndrome (ACS) patients received percutaneous coronary intervention (PCI). Three hundred and twenty-five ACS patients (age ≥ 60 years), all received drug-eluting stents implantation, were assigned into tirofiban group (n = 210) to receive tirofiban+aspirin and clopidogrel and control group (n = 115) to received aspirin and clopidogrel only. The incidence of thrombolysis in myocardial infarction (TIMI) grade 3 after PCI, in-stent thrombosis, slight/severe bleeding, platelet decrease, myocardial infarction (MI) and target vessel revascularization (TVR) within 30 days and 12 months after PCI and 30 days and 12 months mortality post PCI. In comparison with the control group, the tirofiban group had significantly higher TIMI grade 3 flow after PCI (99.05% vs. 94.78%, P < 0.05), lower in-stent thrombosis (0.47% vs. 2.61%, P < 0.05), as well as lower mortality, MI, and TVR in 30 days and 12 months after PCI (30 days: 0, 0.47% and 0.47% vs. 2.61%, 3.48% and 2.61%; 12 months: 0, 0.47% and 0.47% vs. 2.61%, 5.22% and 5.22%, P < 0.05 or P < 0.01). No significant difference was found (both P > 0.05) in slight bleeding (7.14% vs. 4.35%) and severe bleeding (0 vs. 0) between tirofiban group and control group. A slight difference in thrombocytopenia was found between tirofiban group and control group (0.95% vs. 0), but it failed to reach the level of statistical significance (P > 0.05). Tirofiban may improve the TIMI grade flow in senior ACS patients after PCI. It also decreases the incidence of in-stent thrombosis, mortality, MI, and TVR in 30 days and 12 months after PCI, without causing increase in severe bleeding and platelet penia. Therefore, it may improve the short/long-term prognosis for these patients.

    • 1 September 2011
      • Vol. 124  (17) , 2767-70

    Extremely low warfarin dose in patients with genotypes of CYP2C9*3/*3 and VKORC1-1639A/A.

    by Lei Gao, Lei He, Jin Luo, Bin Xu, Jie Yang, Yu-Xiao Zhang, Ting Yang, Ke Li, Jin-Wen Tian, Hong-Juan Wang, et al.

    Patients with the genotypes of both CYP2C9*3/*3 and VKORC1-1639 A/A are expected to require the lowest dose of warfarin, and to have a greatly increased risk of bleeding. The experience for the dosing of warfarin in such extremely rare cases has been seldom reported. Demographic and clinical data from two cases with stable low dose of warfarin in China were studied by resequencing the corresponding gene segments in their whole blood DNA. The potential clinical value of the pharmacogenetic algorithm for them was evaluated by calculating the stable dose of warfarin in pharmacogenetic algorithm developed by International Warfarin Pharmacogenetics Consortium. Both cases (68-year-old female and 50-year-old male) were diagnosed as chronic nonvalvular atrial fibrillation needing warfarin treatment, with target international normalized ratio (INR) 2 to 3. Case 1 had stable warfarin dose of 0.625 mg/d and case 2 1.25 mg/d. They needed more than 1 month to stabilize their anticoagulation. Exceeding INR values were recorded for them when the dose of warfarin was no more than 2 mg/d. Hemorrhagic complication appeared in case 1 when the dose was titrated from 2.5 to 1.25 mg/d. No concomitant medicine to increase or decrease the INR value was recorded for them. Genotyping CYP2C9 and VKORC1 showed both patients were the carriers of the homozygous alleles -CYP2C9*3/*3 and VKORC1-1639 A/A. Their stable doses of warfarin calculated by the pharmacogenetic dose algorithm (0.672 mg/d for case 1 and 1.16 mg/d for case 2) were comparable with their actual stable therapeutic doses. Two Chinese with the rare genotypes of both CYP2C9*3/*3 and VKORC1-1639 A/A were found to require the extremely low dose of warfarin. The pharmacogenetic algorithm incorporating the variances of VKORC1 and CYP2C9 genotypes, as well as the non-genetic factors could predict their stable dose of warfarin with high accuracy.


    • 1 November 2006
      • Vol. 34  (11) , 971-4

    [Safety and efficacy comparison between rapamycin-eluting stent with biodegradable polymer or permanent polymer in patients with coronary artery disease].

    by Yu-Xiao Zhang, Cai-Yi Lu, Qiao Xue, Peng Liu, Wei Yan, Xing-Li Wu, Rui Chen

    To evaluate the safety and efficacy of rapamycin-eluting stent with biodegradable polymer (EXCEL) or permanent polymer (Cypher) in patients with coronary artery disease (CAD). In this prospective, non-random and comparative study, 60 patients with CAD were divided into EXCEL group (n = 32) and Cypher group (n = 28). The coronary angiography (CAG) and stenting procedure were identical. The safety and efficacy of EXCEL stent was evaluated by major adverse cardiac events (MACE), restenosis rate and percent diameter stenosis rate as well as late luminal loss (LLL) at six months post stenting. During follow-up (mean: 6.04 +/- 2.12 months), there was no MACE in the two groups. Quantitative coronary angiography (QCA) data at 6.0 +/- 2.1 months post stenting were available in 27 patients (84.38%) in EXCEL group and 10 patients (35.71%) in Cypher group. Restenosis rate was zero in both groups. Percent diameter stenosis rate (5.98% +/- 5.52% vs. 5.21% +/- 6.3%) and LLL (-0.02 +/- 0.09 mm vs. -0.01 +/- 0.07 mm) were similar between the 2 groups. EXCEL stent was safe for the treatment of CAD and comparable as Cypher stent in preventing MACE and restenosis at 6 months post stenting.