Samir Moujaes
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Samir Moujaes has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
A. Heller
M.S. Graduate Student, Dept. of Mechanical Engineering, Univ. of Nevada Las Vegas, Las Vegas, NV 89154-4027
1 shared publication- Alex Heller1 shared publication
Armin Saraei
Department of Mechanical Engineering, College of Engineering, University of Nevada Las Vegas, Las Vegas, USA
1 shared publicationDaniel Heller
1 shared publication- Deborah A. Kuhls
University of Nevada School of Medicine,Las Vegas,NevadaUSA
1 shared publication Jayant Patil
University of Nevada Las Vegas
1 shared publication
Latest Publications
- Open Access
CFD Study of the Effects of Groove Geometries on Heat Transfer for Internally Grooved Tubes
The CFD study investigated three different groove geometries: circular, rectangular, and trapezoidal grooves, and these results were compared to a smooth tube. The results obtained from this CFD study were compared with experimental work completed for Reynolds numbers of 10,000, 22,000, 34,000, and 38,000. A CFD analysis for Reynolds numbers between 10,000 and 50,000 were performed to further investigate the effects of heat transfer on these geometries. This CFD work validated the experimental results and analyzed three additional Reynolds numbers of 42,000, 46,000, and 50,000 to further evaluate the turbulence effect on heat transfer. For increasing Reynolds numbers in the turbulence region, the Nusselt number significantly increased. The Nusselt number for the grooved geometries was significantly greater than that of the smooth tube. The augmented grooves resulted in the greatest enhancement of heat transfer for the circular, rectangular, and trapezoidal grooves at a Reynolds number of 34,000 and were 63%, 31%, and 58%, respectively. These results are consistent with the experimentally obtained results for the circular, rectangular, and trapezoidal grooves of 63%, 47%, and 58%, when compared to the smooth tube. It was observed that overall thermal enhancement was greatest for the augmented grooves in the Reynolds number range between 10,000 and 20,000. The friction factor for each grooved tube increased with higher Reynolds numbers, while the smooth tube showed a reduction in friction factor for the range 10,000 < Re < 38,000. All three grooves had greater axial pressure drop than the compared smooth tube. The rectangular groove exhibited the greatest axial pressure drop, while the circular and trapezoidal grooves were similar in their results. The mean heat enhancement factors for the circular, rectangular, and trapezoidal grooves were determined to be 1.40, 1.12, and 1.25, respectively. Therefore, all three grooved geometries proved to be thermodynamically advantageous when compared to the smooth tube.
Open AccessCFD Study of the Effects of Groove Geometries on Heat Transfer for Internally Grooved Tubes
The CFD study investigated three different groove geometries: circular, rectangular, and trapezoidal grooves, and these results were compared to a smooth tube. The results obtained from this CFD study were compared with experimental work completed for Reynolds numbers of 10,000, 22,000, 34,000, and 38,000. A CFD analysis for Reynolds numbers between 10,000 and 50,000 were performed to further investigate the effects of heat transfer on these geometries. This CFD work validated the experimental results and analyzed three additional Reynolds numbers of 42,000, 46,000, and 50,000 to further evaluate the turbulence effect on heat transfer. For increasing Reynolds numbers in the turbulence region, the Nusselt number significantly increased. The Nusselt number for the grooved geometries was significantly greater than that of the smooth tube. The augmented grooves resulted in the greatest enhancement of heat transfer for the circular, rectangular, and trapezoidal grooves at a Reynolds number of 34,000 and were 63%, 31%, and 58%, respectively. These results are consistent with the experimentally obtained results for the circular, rectangular, and trapezoidal grooves of 63%, 47%, and 58%, when compared to the smooth tube. It was observed that overall thermal enhancement was greatest for the augmented grooves in the Reynolds number range between 10,000 and 20,000. The friction factor for each grooved tube increased with higher Reynolds numbers, while the smooth tube showed a reduction in friction factor for the range 10,000 < Re < 38,000. All three grooves had greater axial pressure drop than the compared smooth tube. The rectangular groove exhibited the greatest axial pressure drop, while the circular and trapezoidal grooves were similar in their results. The mean heat enhancement factors for the circular, rectangular, and trapezoidal grooves were determined to be 1.40, 1.12, and 1.25, respectively. Therefore, all three grooved geometries proved to be thermodynamically advantageous when compared to the smooth tube.
- Open Access
CFD Analysis of Heat Transfer Enhancement for Twisted Tape Inserted in Spirally Corrugated Tubes and Proposal of a New Vane-Inserted Geometry
This research investigates the enhancement of heat transfer in a heat exchanger that is made of a corrugated tube which has a twisted plate inserted in it; the corrugation and twisted plate are expected to increase the amount of heat transfer since the plate is acting as a connection between the center of the flow and the edges of the tube. The turbulence will cause an increase in pressure drop along the channel length, so the investigation will try to find the best compromise between the gain in heat transfer and loss of hydraulic energy by using well-established metrics. A positive heat transfer gain is achieved if the metric indicates a value equal to or greater than 1. This CFD research will be compared with the experimental results found in previous studies cited in the text. After validating the CFD results, it is proposed to investigate a new insert geometry to further improve the efficiency of the heat exchanger. The computational fluid dynamics (CFD) simulation was conducted to investigate and validate the CFD model, which evaluates the heat transfer performance in a spirally corrugated tube that has a twisted tape inserted. The heat transfer was then compared to a simple corrugated tube without the twisted tape and to a smooth tube with no corrugations and no twisted tape.
Open AccessCFD Analysis of Heat Transfer Enhancement for Twisted Tape Inserted in Spirally Corrugated Tubes and Proposal of a New Vane-Inserted Geometry
This research investigates the enhancement of heat transfer in a heat exchanger that is made of a corrugated tube which has a twisted plate inserted in it; the corrugation and twisted plate are expected to increase the amount of heat transfer since the plate is acting as a connection between the center of the flow and the edges of the tube. The turbulence will cause an increase in pressure drop along the channel length, so the investigation will try to find the best compromise between the gain in heat transfer and loss of hydraulic energy by using well-established metrics. A positive heat transfer gain is achieved if the metric indicates a value equal to or greater than 1. This CFD research will be compared with the experimental results found in previous studies cited in the text. After validating the CFD results, it is proposed to investigate a new insert geometry to further improve the efficiency of the heat exchanger. The computational fluid dynamics (CFD) simulation was conducted to investigate and validate the CFD model, which evaluates the heat transfer performance in a spirally corrugated tube that has a twisted tape inserted. The heat transfer was then compared to a simple corrugated tube without the twisted tape and to a smooth tube with no corrugations and no twisted tape.
- Open Access
- 5 September 2023
- Published by MDPI AG in Preprints.org
CFD Analysis of Heat Transfer Enhancement for Twisted Tape Inserted in spirally Corrugated Tubes
In this study, a computational fluid dynamics (CFD) simulation was conducted to validate the CFD model with experimental data from Zimparov et.al (2012), which investigates the heat transfer performance in a spirally corrugated tube that has a twisted tape inserted. The heat transfer was then compared to a simple corrugated tube without the twisted tape and to a smooth tube with no corrugations and no twisted tape. This simulation is compared with a previous experimental study conducted by (Zimparov et al. 2012), which focuses on tubes with a height-to-diameter ratio e/Di > 0.04 and small relative pitches of the twisted tape, H/Di. The largest improvement was noticed in the tube with e/Di= 0.057 and ridge pitch-to-height ratio p/e=6.77 with a twisted tape of H/Di= 4.7. This tube is labeled 5035. Tube 5035 was found to have the most significant enhancement, hence the focus of the CFD simulation will be on this tube, and the simulation will range for Reynolds numbers, 3.5 x 103 < Re < 5.0 x 104. The focus of this simulation is the evaluation of heat transfer and friction factors; a metric was used to obtain an empirical representation of the tube’s performance. Keywords: Spirally corrugated tube; Twisted tape; Heat transfer enhancement; Friction factor; Nusselt number; Computational fluid dynamics (CFD); Star CCM+
- 5 September 2023
- Published by MDPI AG in Preprints.org
Open AccessCFD Analysis of Heat Transfer Enhancement for Twisted Tape Inserted in spirally Corrugated Tubes
In this study, a computational fluid dynamics (CFD) simulation was conducted to validate the CFD model with experimental data from Zimparov et.al (2012), which investigates the heat transfer performance in a spirally corrugated tube that has a twisted tape inserted. The heat transfer was then compared to a simple corrugated tube without the twisted tape and to a smooth tube with no corrugations and no twisted tape. This simulation is compared with a previous experimental study conducted by (Zimparov et al. 2012), which focuses on tubes with a height-to-diameter ratio e/Di > 0.04 and small relative pitches of the twisted tape, H/Di. The largest improvement was noticed in the tube with e/Di= 0.057 and ridge pitch-to-height ratio p/e=6.77 with a twisted tape of H/Di= 4.7. This tube is labeled 5035. Tube 5035 was found to have the most significant enhancement, hence the focus of the CFD simulation will be on this tube, and the simulation will range for Reynolds numbers, 3.5 x 103 < Re < 5.0 x 104. The focus of this simulation is the evaluation of heat transfer and friction factors; a metric was used to obtain an empirical representation of the tube’s performance. Keywords: Spirally corrugated tube; Twisted tape; Heat transfer enhancement; Friction factor; Nusselt number; Computational fluid dynamics (CFD); Star CCM+
- 23 December 2020
- Published by Springer Nature in Building Simulation
- Vol. 14 (4) , 1063-1075
The effects of exhaust air vent location on thermal comfort inside a residential building equipped with an evaporative cooling system
- 23 December 2020
- Published by Springer Nature in Building Simulation
- Vol. 14 (4) , 1063-1075
The effects of exhaust air vent location on thermal comfort inside a residential building equipped with an evaporative cooling system
- 1 September 2016
- Published by Association for the Advancement of Medical Instrumentation (AAMI) in Biomedical Instrumentation & Technology
- Vol. 50 (5) , 336-348
Research : Testing of a Novel Portable Body Temperature Conditioner Using a Thermal Manikin
A battery-operated active cooling/heating device was developed to maintain thermoregulation of trauma victims in austere environments while awaiting evacuation to a hospital for further treatment. The use of a thermal manikin was adopted for this study in order to simulate load testing and evaluate the performance of this novel portable active cooling/heating device for both continuous (external power source) and battery power. The performance of the portable body temperature conditioner (PBTC) was evaluated through cooling/heating fraction tests to analyze the heat transfer between a thermal manikin and circulating water blanket to show consistent performance while operating under battery power. For the cooling/heating fraction tests, the ambient temperature was set to 15°C ± 1°C (heating) and 30°C ± 1°C (cooling). The PBTC water temperature was set to 37°C for the heating mode tests and 15°C for the cooling mode tests. The results showed consistent performance of the PBTC in terms of cooling/he...
- 1 September 2016
- Published by Association for the Advancement of Medical Instrumentation (AAMI) in Biomedical Instrumentation & Technology
- Vol. 50 (5) , 336-348
Research : Testing of a Novel Portable Body Temperature Conditioner Using a Thermal Manikin
A battery-operated active cooling/heating device was developed to maintain thermoregulation of trauma victims in austere environments while awaiting evacuation to a hospital for further treatment. The use of a thermal manikin was adopted for this study in order to simulate load testing and evaluate the performance of this novel portable active cooling/heating device for both continuous (external power source) and battery power. The performance of the portable body temperature conditioner (PBTC) was evaluated through cooling/heating fraction tests to analyze the heat transfer between a thermal manikin and circulating water blanket to show consistent performance while operating under battery power. For the cooling/heating fraction tests, the ambient temperature was set to 15°C ± 1°C (heating) and 30°C ± 1°C (cooling). The PBTC water temperature was set to 37°C for the heating mode tests and 15°C for the cooling mode tests. The results showed consistent performance of the PBTC in terms of cooling/he...
- 1 September 2016
- Published by American Society of Civil Engineers (ASCE) in Journal of Energy Engineering
- Vol. 142 (3)
CFD Performance Prediction of a Parallel-Counterparallel Flow Heat Exchanger Used for the Treatment of Hypothermia
The aim of this study is to investigate the use of computational fluid dynamics (CFD) in evaluating the thermal performance of a parallel/counterparallel flow heat exchanger used as part of a fluid warmer to treat hypothermia. The developed CFD model was validated in a parametric study using previously collected experimental data. The effects of heat exchanger length and inlet mass flow rate were considered. To more accurately represent the thermodynamic average temperature profile, the current CFD analysis evaluated outlet temperatures in terms of mean bulk temperature as opposed to the centerpoint temperature probe used in the experimental study. Despite this difference, the CFD results were found to agree well with the experimental values. As such, the CFD simulations are not only applicable to future design considerations but elicit further understanding of the thermal and hydrodynamic characteristics within the heat exchanger. Using the validated CFD model, thermal hydraulic entrance lengths and pressure drop within the semiannular geometry of the heat exchanger were investigated. CFD results of the semiannulus were compared to calculated values for a true concentric annulus. It was shown that the entrance length of a concentric annulus is generally longer than the semiannulus under laminar flow, and the difference is more prominent for increasing Reynolds number. Under both laminar and turbulent flow, the studied semiannulus of the hot water region demonstrated a greater pressure drop than a true concentric annulus with similar dimensions and flow conditions. The thermal and hydrodynamic properties revealed in this CFD analysis can be used to improve future design considerations, which may lead to improved hypothermia treatment protocols.
- 1 September 2016
- Published by American Society of Civil Engineers (ASCE) in Journal of Energy Engineering
- Vol. 142 (3)
CFD Performance Prediction of a Parallel-Counterparallel Flow Heat Exchanger Used for the Treatment of Hypothermia
The aim of this study is to investigate the use of computational fluid dynamics (CFD) in evaluating the thermal performance of a parallel/counterparallel flow heat exchanger used as part of a fluid warmer to treat hypothermia. The developed CFD model was validated in a parametric study using previously collected experimental data. The effects of heat exchanger length and inlet mass flow rate were considered. To more accurately represent the thermodynamic average temperature profile, the current CFD analysis evaluated outlet temperatures in terms of mean bulk temperature as opposed to the centerpoint temperature probe used in the experimental study. Despite this difference, the CFD results were found to agree well with the experimental values. As such, the CFD simulations are not only applicable to future design considerations but elicit further understanding of the thermal and hydrodynamic characteristics within the heat exchanger. Using the validated CFD model, thermal hydraulic entrance lengths and pressure drop within the semiannular geometry of the heat exchanger were investigated. CFD results of the semiannulus were compared to calculated values for a true concentric annulus. It was shown that the entrance length of a concentric annulus is generally longer than the semiannulus under laminar flow, and the difference is more prominent for increasing Reynolds number. Under both laminar and turbulent flow, the studied semiannulus of the hot water region demonstrated a greater pressure drop than a true concentric annulus with similar dimensions and flow conditions. The thermal and hydrodynamic properties revealed in this CFD analysis can be used to improve future design considerations, which may lead to improved hypothermia treatment protocols.
- 1 January 2015
- Published by Springer Nature
- p. 95-100
3D CFD Simulation of the Thermal Performance of an Air Channel Solar Heater
- 1 January 2015
- Published by Springer Nature
- p. 95-100
3D CFD Simulation of the Thermal Performance of an Air Channel Solar Heater