Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Alvin Christopher Galang Varquez has a total of 80 co-authors. Here are the top co-authors by number of shared publications:

  • Manabu Kanda

    Department of Transdisciplinary Science and Engineering, School of Environment and Society, Institute of Science Tokyo, Tokyo, 152-8552, Japan

    22 shared publications
  • Manabu Kanda

    Dept. of Transdisciplinary Sci. and Eng., Institute of Science Tokyo

    7 shared publications
  • Atsushi Inagaki

    Department of Transdisciplinary Science and Engineering, School of Environment and Society, Institute of Science Tokyo, Tokyo, 152-8552, Japan

    6 shared publications
  • Do Ngoc Khanh

    SIT Research Laboratories Shibaura Institute of Technology Tokyo Japan

    6 shared publications
  • Tomohiko Ihara

    Department of Environment Systems, Graduate School of Frontier Sciences, The University of Tokyo, 5-1-5 Kashiwanoha, Kashiwa, Chiba 277-8563, Japan

    5 shared publications
  • Xiao Jin

    Department of Transdisciplinary Science and Engineering School of Environment and Society Institute of Science Tokyo Tokyo Japan

    5 shared publications

Latest Publications

  • Open Access

    Reply on RC1

    by I Dewa G. A. Junnaedhi, Muhammad Arkan, An Nur A. Muzasyaroh, Dwina Nugraha, Rachmy Fitriani, Muhammad R. Abdillah, Rusmawan Suwarman, Sukendra Sukendra, Alvin C. G. Varquez, Atsushi Inagaki, et al.

    Climate change and rapid urbanization have increased the need for dense air temperature and humidity monitoring networks in tropical cities. Although low-cost sensors are widely available, the cost of radiation shields remains a major barrier to large-scale deployment. This study presents a low-cost horizontal tube radiation shield (H-Tube) constructed from commercially available pipes and fittings combined with a small number of 3D-printed components. Two versions were developed: a bright-annealed stainless-steel shield (H-TubeSS) and a PVC shield covered with aluminum foil (H-TubePVC). Material costs were approximately USD 25 and USD 11, respectively, making them about 8 and 18 times less expensive than typical commercial radiation shields (>USD 200). Performance was evaluated through comparative field experiments in a tropical urban environment in Bandung, Indonesia, using identical Vaisala HMP155A temperature-humidity probes. Measurements from the H-Tube were compared against a Cotton Region Shelter (CRS) reference and two commercial radiation shields: a multiplate (MP) shield and a vertical tube (V-Tube) shield. Under non-aspirated conditions, daytime temperature biases exceeded 4 °C and relative humidity biases exceeded 15% during periods of strong net radiation. In contrast, aspirated operation substantially improved performance, with temperature biases generally remaining within ±1 °C and relative humidity biases within ±5%, comparable to those of the commercial MP and V-Tube shields. The aspirated H-TubeSS achieved a temperature RMSE of 0.49 °C relative to the CRS, comparable to the MP shield (0.53 °C) and slightly lower than the H-TubePVC (0.58 °C). Simple bias-correction methods based on linear temperature regression and saturation-vapor-pressure adjustment for relative humidity were also developed and evaluated. For the H-Tube designs, temperature RMSE was reduced from 1.35-1.46 °C to approximately 0.56 °C under non-aspirated conditions and from 0.49-0.58 °C to 0.30-0.35 °C under aspirated conditions. Relative humidity RMSE was reduced to approximately 2.6-3.2% after correction. The correction methods also reduced temperature-measurement uncertainty, particularly for the non-aspirated configurations. These results demonstrate that the aspirated H-Tube provides a practical, scalable, and low-cost alternative to commercial radiation shields for distributed temperature-humidity monitoring networks in tropical urban environments.

  • Open Access

    Comment on egusphere-2026-4598

    by I Dewa G. A. Junnaedhi, Muhammad Arkan, An Nur A. Muzasyaroh, Dwina Nugraha, Rachmy Fitriani, Muhammad R. Abdillah, Rusmawan Suwarman, Sukendra Sukendra, Alvin C. G. Varquez, Atsushi Inagaki, et al.

    Climate change and rapid urbanization have increased the need for dense air temperature and humidity monitoring networks in tropical cities. Although low-cost sensors are widely available, the cost of radiation shields remains a major barrier to large-scale deployment. This study presents a low-cost horizontal tube radiation shield (H-Tube) constructed from commercially available pipes and fittings combined with a small number of 3D-printed components. Two versions were developed: a bright-annealed stainless-steel shield (H-TubeSS) and a PVC shield covered with aluminum foil (H-TubePVC). Material costs were approximately USD 25 and USD 11, respectively, making them about 8 and 18 times less expensive than typical commercial radiation shields (>USD 200). Performance was evaluated through comparative field experiments in a tropical urban environment in Bandung, Indonesia, using identical Vaisala HMP155A temperature-humidity probes. Measurements from the H-Tube were compared against a Cotton Region Shelter (CRS) reference and two commercial radiation shields: a multiplate (MP) shield and a vertical tube (V-Tube) shield. Under non-aspirated conditions, daytime temperature biases exceeded 4 °C and relative humidity biases exceeded 15% during periods of strong net radiation. In contrast, aspirated operation substantially improved performance, with temperature biases generally remaining within ±1 °C and relative humidity biases within ±5%, comparable to those of the commercial MP and V-Tube shields. The aspirated H-TubeSS achieved a temperature RMSE of 0.49 °C relative to the CRS, comparable to the MP shield (0.53 °C) and slightly lower than the H-TubePVC (0.58 °C). Simple bias-correction methods based on linear temperature regression and saturation-vapor-pressure adjustment for relative humidity were also developed and evaluated. For the H-Tube designs, temperature RMSE was reduced from 1.35-1.46 °C to approximately 0.56 °C under non-aspirated conditions and from 0.49-0.58 °C to 0.30-0.35 °C under aspirated conditions. Relative humidity RMSE was reduced to approximately 2.6-3.2% after correction. The correction methods also reduced temperature-measurement uncertainty, particularly for the non-aspirated configurations. These results demonstrate that the aspirated H-Tube provides a practical, scalable, and low-cost alternative to commercial radiation shields for distributed temperature-humidity monitoring networks in tropical urban environments.

  • Open Access

    Design and Evaluation of a Low-Cost Horizontal Tube Radiation Shield for Temperature and Humidity Measurements in a Tropical Urban Environment

    by I Dewa G. A. Junnaedhi, Muhammad Arkan, An Nur A. Muzasyaroh, Dwina Nugraha, Rachmy Fitriani, Muhammad R. Abdillah, Rusmawan Suwarman, Sukendra Sukendra, Alvin C. G. Varquez, Atsushi Inagaki, et al.

    Climate change and rapid urbanization have increased the need for dense air temperature and humidity monitoring networks in tropical cities. Although low-cost sensors are widely available, the cost of radiation shields remains a major barrier to large-scale deployment. This study presents a low-cost horizontal tube radiation shield (H-Tube) constructed from commercially available pipes and fittings combined with a small number of 3D-printed components. Two versions were developed: a bright-annealed stainless-steel shield (H-TubeSS) and a PVC shield covered with aluminum foil (H-TubePVC). Material costs were approximately USD 25 and USD 11, respectively, making them about 8 and 18 times less expensive than typical commercial radiation shields (>USD 200). Performance was evaluated through comparative field experiments in a tropical urban environment in Bandung, Indonesia, using identical Vaisala HMP155A temperature-humidity probes. Measurements from the H-Tube were compared against a Cotton Region Shelter (CRS) reference and two commercial radiation shields: a multiplate (MP) shield and a vertical tube (V-Tube) shield. Under non-aspirated conditions, daytime temperature biases exceeded 4 °C and relative humidity biases exceeded 15% during periods of strong net radiation. In contrast, aspirated operation substantially improved performance, with temperature biases generally remaining within ±1 °C and relative humidity biases within ±5%, comparable to those of the commercial MP and V-Tube shields. The aspirated H-TubeSS achieved a temperature RMSE of 0.49 °C relative to the CRS, comparable to the MP shield (0.53 °C) and slightly lower than the H-TubePVC (0.58 °C). Simple bias-correction methods based on linear temperature regression and saturation-vapor-pressure adjustment for relative humidity were also developed and evaluated. For the H-Tube designs, temperature RMSE was reduced from 1.35-1.46 °C to approximately 0.56 °C under non-aspirated conditions and from 0.49-0.58 °C to 0.30-0.35 °C under aspirated conditions. Relative humidity RMSE was reduced to approximately 2.6-3.2% after correction. The correction methods also reduced temperature-measurement uncertainty, particularly for the non-aspirated configurations. These results demonstrate that the aspirated H-Tube provides a practical, scalable, and low-cost alternative to commercial radiation shields for distributed temperature-humidity monitoring networks in tropical urban environments.

  • Open Access

    Implementation of a GeoAI Model to Detect Ground-Mounted Photovoltaic Power Stations in Thailand

    by Linux Farungsang, Alvin Christopher G. Varquez, Koji Tokimatsu

    A comprehensive and publicly available geospatial database of PV installations is crucial for effective policymaking and infrastructure planning towards Thailand’s carbon neutrality and net-zero greenhouse gas emissions plan. This study introduces a national-scale mapping framework for ground-mounted photovoltaic power stations using geospatial artificial intelligence (GeoAI). A pretrained deep learning model is applied to Sentinel-2 satellite imagery to delineate solar photovoltaic sites. The outputs are cross-checked and verified with official statistical data. Geospatial analyses and regression-based comparisons are conducted to validate the infrastructure inventory. The results indicate that all registered solar PV sites were identified, with a total mapped area of 14.55 km2 and a capacity of 506.4 megawatts. Furthermore, the research clarifies that without official administrative ownership data, GeoAI cannot be applied more broadly for policy evaluation. Closing these data infrastructure gaps is necessary to support more effective energy planning and monitoring in Thailand.

  • Open Access

    Evaluating different satellite-based Aerosol Optical Depth (AOD) in predicting inland daytime PM 2.5 using machine learning-based regression approach

    by Roseanne V. Ramos, Mark Joseph R. Calubad, Alvin Christopher G. Varquez

    Aerosols play a critical role in the development of the boundary layer and build-up of air pollution in urban environments. Their presence in the atmosphere is quantified by Aerosol Optical Depth (AOD). Satellite sensors observe and retrieve AOD at varied spatial and temporal resolutions. In air quality monitoring, satellite-based AOD products are typically utilized to predict ground concentrations of fine particulate matter (PM2.5) through various modelling approaches. This study evaluates AOD products observed by Moderate Resolution Imaging Spectroradiometer (MODIS), Visible Infrared Imaging Radiometer Suite (VIIRS) and the Advanced Himawari Imager (AHI) of Himawari-8 in predicting inland daytime PM2.5 concentrations for test sites in Japan and South Korea. Prediction models were constructed using eXtreme Gradient Boosting (XGBoost) regression with input variables from observation datasets matched on ground PM2.5 station locations. In addition to AOD, twelve (12) predictor variables representing topographic and meteorological parameters were considered. Prediction results were evaluated using Kruskal-Wallis test and effect size analysis to compare the absolute error distributions across AOD products. Statistical results indicate that while models utilizing MODIS AOD generalize better to new data, the overall difference in prediction accuracy is statistically negligible. These findings suggest that no single AOD product is significantly superior in predicting ground-level PM2.5 concentrations, highlighting the potential of integrating AOD values from various sources. This work is essential for improving the accuracy of PM2.5 estimates and for supporting more effective mapping of urban air pollution.

  • Open Access

    Comparative Analysis of Future Urban Thermal Comfort in Three Cities Considering Urbanization Under Multiple CMIP6 Scenarios

    by Xiao Jin, Alvin C. G. Varquez, Do Ngoc Khanh, Tomohiko Ihara, Norihiro Itsubo, Manabu Kanda, I. Dewa Gede Agung Junnaedhi

    This work investigates variations in thermal conditions in cities with different background climates exposed to climate change and future urbanization (i.e., horizontal/vertical urban expansion and energy consumption change). Simultaneously considering projected urbanization from the present to the 2050s, characterized by spatial changes in urban parameters and anthropogenic heat emissions (AHE), 1.5‐km present and future climates of Tokyo, Cairo, and Jakarta in the 2050s were modeled using initial and boundary conditions from the National Centers for Environmental Prediction Global Data Assimilation System/Final (NCEP GDAS/FNL) 0.25° Global Tropospheric Analyses and Forecast Grids and Coupled Model Intercomparison Project Phase 6 (CMIP6) climate‐change scenarios based on Shared Socioeconomic Pathways (SSP126, SSP245, and SSP370). The Universal Thermal Climate Index (UTCI) was estimated using the UTCI‐Fiala model. Regional near‐surface air temperature and UTCI scaled proportionally with background climate changes. Projected urbanization caused significant intra‐urban variability, with some locations showing warming comparable to background climate change. It also altered strong heat‐stress exposure, defined as hours with UTCI , amplifying exposure in Cairo and Jakarta but slightly offsetting it in Tokyo, where AHE declined. Cities with different background climates exhibited distinct seasonal responses: Tokyo showed moderate bimodal variability, Cairo exhibited the strongest variability with peak summer warming, and Jakarta showed a uniform increase year‐round. Near‐surface air temperature and UTCI responses to urbanization also varied seasonally across scenarios and cities, while variables beyond air temperature contributed to thermal‐comfort changes. This study strengthens the necessity of projecting not only meteorology, but also socially relevant indices, such as UTCI.


  • Open Access

    Drainage Duration Variability and PALSAR-2 Sensitivity to Rice-Field Water Status: Insights from Large-Scale In Situ Water-Level Observations

    by Xiao Jin, Muditha Madusanka Dantanarayana, Alexis Declaro, Shinjiro Kanae, Alvin C. G. Varquez

    Achieving scalable monitoring of Alternate Wetting and Drying (AWD) for methane mitigation in rice cultivation depends on establishing field benchmarks for drainage behavior and demonstrating that satellite observations can reliably detect corresponding changes in water status. We analyzed about two million high-frequency in situ water-level observations from hundreds of sensors deployed in rice fields across the Philippines and Japan to quantify drainage duration from near-surface conditions to 15 cm below the soil surface and to test the sensitivity of open-access PALSAR-2 dual-polarization L-band SAR to vertical water-level variations. Across 564 drainage events, the median drainage duration was 19.0 h, and only 0.9% of events exceeded 240 h, indicating that drainage happens generally within a day. Seasonal differences were evident in Pangasinan, while small Chiba and Cagayan samples suggested exploratory longer-duration patterns; multiple drainage events occurred in 48.0% of Philippine dry-season fields but only 21.6% of wet-season fields. PALSAR-2 data showed a statistical significance in detecting inundation at Mid crop growth stage with cross-polarization band, but the significant overlap induces challenges in operational applications. These results provide empirical benchmarks for AWD-related drainage dynamics while showing that dual-polarization PALSAR-2 alone is unlikely to support robust field-scale monitoring of rice-field water status.


  • Open Access

    Drainage Duration Variability and PALSAR-2 Sensitivity to Rice Field Water Status: Insights from Large-Scale In Situ Water-Level Observations

    by Xiao Jin, Muditha Madusanka Dantanarayana, Alexis Declaro, Shinjiro Kanae, Alvin C.G. Varquez

    Achieving scalable monitoring of Alternate Wetting and Drying (AWD) for methane mitigation in rice cultivation depends on establishing field benchmarks for drainage behavior and demonstrating that satellite observations can reliably detect corresponding changes in water status. We analyzed about two million high-frequency in situ water-level observations from hundreds of sensors deployed in rice fields across Philippines and Japan to quantify drainage duration from near-surface conditions to 15 cm below the soil surface and to test the sensitivity of open-access PALSAR-2 dual-polarization L-band SAR to vertical water level variations. Across 564 drainage events, the median drainage duration was 19.0 h, and only 0.9% of events exceeded 240 h, indicating that drainage happens generally within a day. Drainage duration varied markedly by region and season, with median values ranging from 10.6 h in Pangasinan wet-season events to 72.6 h in Cagayan dry-season events; multiple drainage events occurred in 48.0% of Philippine dry-season fields but only 21.6% of wet-season fields. PALSAR-2 data shows a statistical significance in detecting inundation at Mid crop growth stage with cross-polarization band, but the significant overlap induce challenges in operational applications. These results provide empirical benchmarks for AWD-related drainage dynamics while showing that dual-polarization PALSAR-2 alone is unlikely to support robust field-scale monitoring of rice-field water status.

  • Open Access

    Improving prediction of PM 2.5 in Metro Manila using XGBoost with Optuna hyperparameter optimization

    by Roseanne V. Ramos, Alvin Christopher G. Varquez

    Reporting air pollution levels in Metro Manila, Philippines remains dependent on records from few ground monitoring stations. For impact studies on human health, grid-based pollution levels datasets will enhance the assessment of the exposure and risk of the local population with a finer spatial resolution. This paper presents an enhanced model for fine particulate matter (PM2.5) in Metro Manila using extreme gradient boosting (XGBoost) with predictor variables from daily satellite observations and climate reanalysis datasets. This study employs XGBoost with Optuna workflow, a Bayesian optimization algorithm, to determine optimal learning parameters achieving least mean absolute error (MAE), root mean squared error (RMSE) and highest coefficient of determination R2 for both training and test datasets to obtain more accurate predictions of PM2.5. Predictor variables assessed are Aerosol Optical Depth (AOD), emissivity, direct solar radiation (DSR), albedo, land surface temperature during daytime (LSTDT) and nighttime (LSTNT), Normalized Difference Vegetation Index (NDVI), wind speed, air temperature, pressure and total precipitation. The results indicate that using a Kriging-based interpolated PM2.5 as target variable achieves the highest R2 = 0.73 and lowest RMSE (1.08 μg/ m3) in the test data using K-fold cross-validation approach (k = 5). The predictors in the best XGBoost model with relatively high feature importance in both gain scores and SHAP values are DSR, precipitation, LSTDT, air temperature and AOD in the 0.47 μm band. These outputs can be utilized in generating daily gridded PM2.5 maps for long-term health impact studies and assessment of seasonal variations of PM2.5 at regional level.


  • Open Access

    URBANIZATION AND CLIMATE CHANGE EFFECTS ON FUTURISTIC THERMAL COMFORT OF THREE MEGACITIES: SSP370 SCENARIO

    by Xiao Jin, Alvin C. G. Varquez, Do Ngoc Khanh, Tomohiko Ihara, Norihiro Itsubo, Manabu Kanda

    Rising climate hazards in urban areas, driven by global climate change and intensified by urbanization, are increasing extreme thermal stress, posing significant risks to thermal comfort and socioeconomic well-being. This study projects high-resolution future urban climate and thermal stress for 2050 under the SSP370 scenario, a high-emission, low-mitigation pathway from the Coupled Model Intercomparison Project Phase 6 (CMIP6). In this research, hourly 1.5 × 1.5-km projections of meteorology and Universal Temperature Climate factor (UTCI) were generated, incorporating urbanization effects (future urban morphology and anthropogenic heat emissions change) across three major cities: Tokyo, Cairo, and Jakarta. Under SSP370, both UTCI and air temperature increase substantially across all cities, with UTCI showing stronger responses. Urban change effects vary distinctly across cities: Tokyo shows cooling due to reduced anthropogenic heat emissions, with air temperature responding more strongly than UTCI, while Cairo and Jakarta experience warming from continued urban development. Despite these differences, the magnitudes of urban change effects are inversely correlated with background temperature across all cities. Analysis of feature importance through machine-learning reveals that urban change-induced UTCI responses are radiation-dominated in Tokyo and Cairo, contrasting with ventilation-dominated responses in humid Jakarta.