Andrew H. Gee
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Andrew H. Gee has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Graham M. Treece
Department of Engineering, University of Cambridge, Cambridge, U.K.
4 shared publications - C.J. Tonkin
University of Cambridge Department of Medicine, Level 5, Addenbrooke's Hospital (Box 157), Hills Road, Cambridge CB2 2QQ, UK
1 shared publication - Dennis M. Black
Department of Epidemiology and Biostatistics University of California, San Francisco San Francisco CA USA
1 shared publication Graham M. Treece
Department of Engineering, University of Cambridge, Cambridge, UK
1 shared publication- Kenneth E. S. Poole
NIHR Biomedical Research Centre, Cambridge University Hospitals NHS Foundation Trust, UK NIHR Cambridge Biomedical Research Centre, Hills Rd, Cambridge CB2 0QQ, UK
1 shared publication - Kenneth E.S. Poole
University of Cambridge Department of Medicine, Level 5, Addenbrooke's Hospital (Box 157), Hills Road, Cambridge CB2 2QQ, UK
1 shared publication
Latest Publications
- Open Access
- 10 February 2021
- Published by Springer Nature in Scientific Reports
- Vol. 11 (1) , 1-11
Practicable assessment of cochlear size and shape from clinical CT images
There is considerable interpersonal variation in the size and shape of the human cochlea, with evident consequences for cochlear implantation. The ability to characterize a specific cochlea, from preoperative computed tomography (CT) images, would allow the clinician to personalize the choice of electrode, surgical approach and postoperative programming. In this study, we present a fast, practicable and freely available method for estimating cochlear size and shape from clinical CT. The approach taken is to fit a template surface to the CT data, using either a statistical shape model or a locally affine deformation (LAD). After fitting, we measure cochlear size, duct length and a novel measure of basal turn non-planarity, which we suggest might correlate with the risk of insertion trauma. Gold-standard measurements from a convenience sample of 18 micro-CT scans are compared with the same quantities estimated from low-resolution, noisy, pseudo-clinical data synthesized from the same micro-CT scans. The best results were obtained using the LAD method, with an expected error of 8–17% of the gold-standard sample range for non-planarity, cochlear size and duct length.
- 10 February 2021
- Published by Springer Nature in Scientific Reports
- Vol. 11 (1) , 1-11
Open AccessPracticable assessment of cochlear size and shape from clinical CT images
There is considerable interpersonal variation in the size and shape of the human cochlea, with evident consequences for cochlear implantation. The ability to characterize a specific cochlea, from preoperative computed tomography (CT) images, would allow the clinician to personalize the choice of electrode, surgical approach and postoperative programming. In this study, we present a fast, practicable and freely available method for estimating cochlear size and shape from clinical CT. The approach taken is to fit a template surface to the CT data, using either a statistical shape model or a locally affine deformation (LAD). After fitting, we measure cochlear size, duct length and a novel measure of basal turn non-planarity, which we suggest might correlate with the risk of insertion trauma. Gold-standard measurements from a convenience sample of 18 micro-CT scans are compared with the same quantities estimated from low-resolution, noisy, pseudo-clinical data synthesized from the same micro-CT scans. The best results were obtained using the LAD method, with an expected error of 8–17% of the gold-standard sample range for non-planarity, cochlear size and duct length.
- Open Access
- 1 April 2018
- Published by Elsevier in Medical Image Analysis
- Vol. 45, 55-67
How does the femoral cortex depend on bone shape? A methodology for the joint analysis of surface texture and shape
- 1 April 2018
- Published by Elsevier in Medical Image Analysis
- Vol. 45, 55-67
Open AccessHow does the femoral cortex depend on bone shape? A methodology for the joint analysis of surface texture and shape
- Open Access
- 1 February 2015
- Published by Elsevier in Medical Image Analysis
- Vol. 20 (1) , 249-264
Independent measurement of femoral cortical thickness and cortical bone density using clinical CT
- 1 February 2015
- Published by Elsevier in Medical Image Analysis
- Vol. 20 (1) , 249-264
Open AccessIndependent measurement of femoral cortical thickness and cortical bone density using clinical CT
- 1 February 2014
- Published by Elsevier in Medical Image Analysis
- Vol. 18 (2) , 385-393
Systematic misregistration and the statistical analysis of surface data
- 1 February 2014
- Published by Elsevier in Medical Image Analysis
- Vol. 18 (2) , 385-393
Systematic misregistration and the statistical analysis of surface data