TMTomohiro Mizuno

Tomohiro Mizuno

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Tomohiro Mizuno has a total of 199 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Hybrid surgical-electrophysiological epicardial cryoablation for ventricular tachycardia storm from a deep intramural substrate in hypertrophic cardiomyopathy: a case report

    by Tadashi Fujino, Shintaro Yao, Kenji Okubo, Tomohiro Mizuno, Takanori Ikeda

    Background: Ventricular tachycardia (VT) associated with hypertrophic cardiomyopathy (HCM) may arise from deep intramural substrates and remains challenging to treat when conventional endocardial or percutaneous epicardial approaches are ineffective or infeasible. Case summary: A 63-year-old man with HCM presented with drug-resistant VT storm. Endocardial mapping showed marked narrowing of the left ventricular (LV) cavity at the midventricular level, without abnormal potentials. Pace mapping demonstrated the closest match at the distal anterolateral coronary venous branch, suggesting a deep intramural origin. A subxiphoid epicardial approach was precluded by prior oesophageal reconstruction; therefore, minimally invasive cardiac surgery via left thoracotomy enabled epicardial cryoablation using the cryoICE system. Epicardial mapping during VT revealed a low-voltage area with fractionated electrograms at the apicolateral LV. Activation time did not span the full VT cycle length, suggesting an epicardial exit with a deep intramural isthmus. VT terminated during the first cryoapplication, followed by two additional applications (total 15 min). No VT recurrence was observed during 1 year of follow-up after discontinuation of amiodarone. Postprocedural cardiac magnetic resonance demonstrated transmural enhancement at the cryoablation target site despite a myocardial thickness of approximately 15 mm, suggesting successful deep lesion formation. Discussion: This case demonstrated that hybrid surgical-electrophysiological cryoablation can provide effective treatment for VT arising from deep intramural substrates when conventional endocardial and percutaneous epicardial approaches are ineffective or infeasible. Surgical cryoablation was associated with transmural enhancement despite marked myocardial hypertrophy and resulted in durable arrhythmia suppression.

  • Open Access

    Recurrent Cerebral Embolism Caused by Sluggish Retrograde Flow from the Residual False Lumen of the Aortic Arch after Type A Aortic Dissection

    by Norihiro Okada, Shinichiro Shimura, Go Hashimoto, Satoshi Fujita, Morito Hayashi, Hidehiko Hara, Tomohiro Mizuno

    A residual false lumen after type A aortic dissection repair may rarely serve as an embolic route to the cerebral circulation. A woman in her 60s underwent ascending aortic replacement for Stanford type A aortic dissection, leaving a residual patent dissection involving the supra-aortic branches and the descending aorta. Despite receiving anticoagulant and antiplatelet therapies, the patient developed recurrent multifocal cerebral infarctions. Transesophageal echocardiography (TEE) demonstrated an entry tear in the descending aorta communicating from the true lumen to the false lumen. Flow became markedly stagnant toward the proximal false lumen, with thrombus-like echogenic material. Four-dimensional computed tomography (4DCT) confirmed delayed retrograde flow ascending within the false lumen toward the arch. Total arch replacement was performed to eliminate the suspected embolic route. Intraoperative findings confirmed thrombotic material within the false lumen. No recurrent cerebral infarctions were observed postoperatively.

  • Open Access

    Left Atrial Mitral Valve Chordae Which Disturbed the Mitral Leaflet Motion and Induced Mitral Regurgitation

    by Toru Kameda, Tomohiro Mizuno, Kota Kawada, Tsubasa Yoshikawa, Koichi Sugiyama, Yuzo Katayama, Takeshiro Fujii

    Left atrial mitral valve chorda (LAMVC) is a rare congenital cardiac anomaly. The abnormal tissue band, like a mitral valve chorda, is attached to the left atrial wall on one side and mostly to the mitral valve leaflet on the other side and the band sometimes disturbs the mitral leaflet motion, followed by mitral regurgitation (MR). We encountered a case with a LAMVC which originated from a papillary muscle and attached to the posterior mitral annulus over the posterior leaflet and caused MR due to restricted mitral leaflet motion.

  • Ring annuloplasty, optionally combined with edge-to-edge leaflet plications, should be amended with subvalvular repair techniques to efficaciously treat tricuspid regurgitation with severe tethering

    by Masashi Takeshita, Hirokuni Arai, Eiki Nagaoka, Keiji Oi, Tatsuki Fujiwara, Kiyotoshi Oishi, Tomohiro Mizuno

    This study aimed to evaluate the outcomes of tricuspid annuloplasty with/without additional edge-to-edge plications in patients with functional tricuspid regurgitation and to clarify the impact of tethering on surgical outcomes. This retrospective observational study included patients with moderate or greater functional tricuspid regurgitation who underwent initial tricuspid valve repair between January 2008 and December 2021. The patients were divided into two groups based on whether they had tethering (preoperative tethering area ≥0.75 cm2). All patients underwent annuloplasty, and edge-to-edge plications were added at the regurgitant leakage site identified by saline tests. The surgical outcomes of each group, and the effect of tethering on recurrent moderate or greater tricuspid regurgitation were evaluated. One-hundred and thirty-three patients were included in this study. During the follow-up period of 55.3 (standard deviation: 44.9) months, the 5-year survival rates were 78.4% in patients without tethering and 76.1% in patients with tethering (P = 0.78). The 5-year cumulative incidence rates of readmission for heart failure and recurrent tricuspid regurgitation were 10.8% and 1.3% in patients without tethering and 23.0% and 29.5% in patients with tethering, respectively (P = 0.12 and <0.001). Multivariable analyses revealed that the preoperative and predischarge tethering areas predicted recurrent tricuspid regurgitation. A large tethering area remained postoperatively in patients with tethering. In patients without tethering, annuloplasty and additional edge-to-edge plications are effective in avoiding recurrent tricuspid regurgitation with satisfactory midterm clinical outcomes. However, in patients with tethering, these procedures resulted in residual tethering, which could be leading to recurrent tricuspid regurgitation.


  • Open Access

    Efficacy of Thromboelastography-Guided Blood Transfusion Management in Thoracic Aortic Surgery

    by Yushi Okumura, Tomohiro Mizuno, Tatsuki Fujiwara, Kiyotoshi Oishi, Masashi Takeshita, Masafumi Yashima, Eiki Nagaoka, Keiji Oi


  • Open Access

    Bovine pericardial patch repair for abdominal aortic pseudoaneurysm to preserve lumbar arteries

    by Junya Nabeshima, Tomohiro Mizuno, Eiki Nagaoka

    We describe a case of aortic repair using bovine pericardium for a pseudoaneurysm of a dissecting abdominal aorta. A 71-year-old man had undergone several aortic replacement surgeries for type B aortic dissection. He developed paraparesis after thoraco-abdominal aortic surgery and recovered. After 3 years, the scheduled computed tomography scan showed a pseudoaneurysm of the dissecting abdominal aorta. Because he was at high risk of spinal cord ischaemia, aortic repair using bovine pericardium was performed, and all lumbar arteries were preserved. During the 12-month follow-up, he was asymptomatic, and computed tomography scans showed no dilation of the aorta.

  • Surgical extraction of cardiac implantable electronic device leads based on a heart team approach

    by Tomohiro Mizuno, Masahiko Goya, Tatsuki Fujiwara, Kiyotoshi Oishi, Masashi Takeshita, Masafumi Yashima, Eiki Nagaoka, Keiji Oi, Tetsuo Sasano


  • Open Access

    Long-term outcomes of papillary muscle relocation anteriorly for functional mitral regurgitation

    by Keiji Oi, Hirokuni Arai, Eiki Nagaoka, Tatsuki Fujiwara, Kiyotoshi Oishi, Masashi Takeshita, Tatsuhiko Anzai, Tomohiro Mizuno

    This study aimed to evaluate the outcomes of the patients who underwent restrictive annuloplasty (RA) plus papillary muscle relocation anteriorly (PMR-A) with the risk factors in mitral valve repair for functional mitral regurgitation (FMR). Eighty-six patients underwent mitral valve repair with RA for FMR. Thirty-five of them received additional bilateral papillary muscle relocation for severe leaflet tethering. The papillary muscles were relocated posteriorly (PMR-P) early in the study. Then, in the later period, the technique was modified to PMR-A, in which the papillary muscles were relocated anteriorly for 24 cases. The survival of the patients undergoing RA + PMR-A was examined retrospectively, adjusting for differences in patient background. Twenty-three deaths were observed during the follow-up period out of the 86 cases. Independent preoperative risk factors for survival were left ventricular ejection fraction, patient age and B-type natriuretic peptide (BNP) level. Among the patients with BNP P = 0.011), while the hazard ratio of RA alone to RA + PMR-A was not significantly different. Furthermore, reverse remodelling of the left ventricle was observed for 3 years only in RA + PMR-A. Long-term survival for patients who underwent RA plus bilateral PMR-A was promising. Patients with significantly higher BNP had lower survival after valve repair for FMR.


  • Innovative experimental animal models for real‐time comparison of antithrombogenicity between two oxygenators using dual extracorporeal circulation circuits and indocyanine green fluorescence imaging

    by Hironobu Sakurai, Tatsuki Fujiwara, Katsuhiro Ohuchi, Wataru Hijikata, Yusuke Inoue, Osamu Maruyama, Tomoki Tahara, Sachie Yokota, Yui Tanaka, Yoshiaki Takewa, et al.

    Background: Antithrombogenicity of extracorporeal membrane oxygenation (ECMO) devices, particularly oxygenators, is a current problem, with numerous studies and developments underway. However, there has been limited progress in developing methods to accurately compare the antithrombogenicity of oxygenators. Animal experiments are commonly conducted to evaluate the antithrombogenicity of devices; however, it is challenging to maintain a steady experimental environment. We propose an innovative experimental animal model to evaluate different devices in a constant experimental environment in real‐time.Methods: This model uses two venous–arterial ECMO circuits attached to one animal (one by jugular vein and carotid artery, one by femoral vein and artery) and real‐time assessment of thrombus formation in the oxygenator by indocyanine green (ICG) fluorescence imaging. Comparison studies were conducted using three pigs: one to compare different oxygenators (MERA vs. CAPIOX) (Case 1), and two to compare antithrombotic properties of the oxygenator (QUADROX) when used under different hydrodynamic conditions (continuous flow vs. pulsatile flow) (Cases 2 and 3).Results: Thrombi, visualized using ICG imaging, appeared as black dots on a white background in each oxygenator. In Case 1, differences in the site of thrombus formation and rate of thrombus growth were observed in real‐time in two oxygenators. In Case 2 and 3, the thrombus region was smaller in pulsatile than in continuous conditions.Conclusions: We devised an innovative experimental animal model for comparison of antithrombogenicity in ECMO circuits. This model enabled simultaneous evaluation of two different ECMO circuits under the same biological conditions and reduced the number of sacrificed experimental animals.


  • The rotational position of the aortic valve: implications for valve-sparing aortic root replacement

    by Kiyotoshi Oishi, Hirokuni Arai, Keiji Oi, Eiki Nagaoka, Masafumi Yashima, Tatsuki Fujiwara, Masashi Takeshita, Tomohiro Mizuno

    OBJECTIVES: There are few reports on the rotational position of the aortic valve relative to the base of the left ventricle, and its influence on valve-sparing aortic root replacement (VSRR) has not been reported. Based on our experience with complications such as right atrial perforation and tricuspid valve injury, we investigated the cause of these complications in terms of morphological variations in the aortic root and its surrounding structures. METHODS: The aortic valve rotation relative to the base of the left ventricle was assessed in 30 patients with tri-leaflet aortic valves who underwent VSRR. The influence of such anatomical variations on surgical procedures was investigated. RESULTS: The aortic valve was positioned normally in 25 patients (83.3%), rotated counterclockwise in 4 (13.3%), and rotated clockwise in 1 patient (3.3%). In patients with a counterclockwise rotated aortic valve, the non-coronary sinus was the largest compared with other sinuses. This aortic valve rotation could be diagnosed by multidetector row computed tomography. In all patients who had difficulty in the external dissection of the right sinus of Valsalva, the aortic valve was counterclockwise rotated and forcible dissection had a risk of right atrial perforation and tricuspid valve injury. CONCLUSIONS: Aortic valve rotation is an element that complicates VSRR. The rotational position of the aortic valve can be diagnosed preoperatively using multidetector row computed tomography and understanding the anatomy of the aortic valve related to rotational position help decide proper surgical decision-making in performing aortic root reconstruction procedure.