IOFI Working Group on Methods of Analysis
IOFI Working Group on Methods of Analysis has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Alain Chaintreau
Firmenich SA, Corporate R&D Division, Route des Jeunes 1, CH-1211 Geneva 8, Switzerland
3 shared publications C. Schippa
IOFI (International Organization of the Flavor Industry), Working Group on Methods of Analysis
3 shared publicationsD. Joulain
IOFI (International Organization of the Flavor Industry), Working Group on Methods of Analysis
3 shared publicationsF. Sekiya
IOFI (International Organization of the Flavor Industry), Working Group on Methods of Analysis
3 shared publicationsG. Loesing
IOFI (International Organization of the Flavor Industry), Working Group on Methods of Analysis
3 shared publicationsH. Brevard
IOFI (International Organization of the Flavor Industry), Working Group on Methods of Analysis
3 shared publications
Latest Publications
- Open Access
- 2 February 2016
- Published by Wiley in Flavour and Fragrance Journal
- Vol. 31 (3) , 191-194
IOFI recommended practice for the use of predicted relative‐response factors for the rapid quantification of volatile flavouring compounds by GC‐FID
This recommended practice enables the quantification of volatile compounds in flavourings to be made by gas chromatography with flame‐ionization detection, without having authentic compounds available, and also in many cases it can avoid time‐consuming calibration procedures. The relative‐response factors (RRF) can be predicted from the molecular formula of the compound, and this approach can be applied to compounds containing the atoms C, H, O, N, S, F, Cl, Br, I, and Si, providing that the molecular formula and number of benzene rings in the analytes are known. The purity of chemically‐defined flavouring substances or chromatographic standards can also be estimated using these predicted RRF, and this procedure can also be used to quantify (poly)hydroxylated compounds, after their derivatization into trimethylsilyl ethers or esters. Copyright © 2016 John Wiley & Sons, Ltd.
- 2 February 2016
- Published by Wiley in Flavour and Fragrance Journal
- Vol. 31 (3) , 191-194
Open AccessIOFI recommended practice for the use of predicted relative‐response factors for the rapid quantification of volatile flavouring compounds by GC‐FID
This recommended practice enables the quantification of volatile compounds in flavourings to be made by gas chromatography with flame‐ionization detection, without having authentic compounds available, and also in many cases it can avoid time‐consuming calibration procedures. The relative‐response factors (RRF) can be predicted from the molecular formula of the compound, and this approach can be applied to compounds containing the atoms C, H, O, N, S, F, Cl, Br, I, and Si, providing that the molecular formula and number of benzene rings in the analytes are known. The purity of chemically‐defined flavouring substances or chromatographic standards can also be estimated using these predicted RRF, and this procedure can also be used to quantify (poly)hydroxylated compounds, after their derivatization into trimethylsilyl ethers or esters. Copyright © 2016 John Wiley & Sons, Ltd.
- Open Access
- 22 December 2014
- Published by Wiley in Flavour and Fragrance Journal
- Vol. 30 (1) , 2-4
IOFI guidelines for the isolation of flavouring substances by simultaneous distillation‐extraction
Simultaneous distillation‐extraction (SDE) combines, in a single step, hydro‐distillation of volatiles from a sample with continuous solvent extraction of the solutes dissolved in the aqueous distillate. The solvent extract containing the isolated flavour volatiles can be subsequently analysed by gas chromatography. The technique is applicable to compounds possessing a wide range of volatility, but it is suitable neither for compounds of low volatility (e.g. vanillin), nor for highly volatile materials (e.g. methanethiol). The present guidelines concern the isolation of flavouring substances by simultaneous distillation‐extraction (SDE), based on the experience of the authors in laboratories of the flavour industry. Copyright © 2014 John Wiley & Sons, Ltd.
- 22 December 2014
- Published by Wiley in Flavour and Fragrance Journal
- Vol. 30 (1) , 2-4
Open AccessIOFI guidelines for the isolation of flavouring substances by simultaneous distillation‐extraction
Simultaneous distillation‐extraction (SDE) combines, in a single step, hydro‐distillation of volatiles from a sample with continuous solvent extraction of the solutes dissolved in the aqueous distillate. The solvent extract containing the isolated flavour volatiles can be subsequently analysed by gas chromatography. The technique is applicable to compounds possessing a wide range of volatility, but it is suitable neither for compounds of low volatility (e.g. vanillin), nor for highly volatile materials (e.g. methanethiol). The present guidelines concern the isolation of flavouring substances by simultaneous distillation‐extraction (SDE), based on the experience of the authors in laboratories of the flavour industry. Copyright © 2014 John Wiley & Sons, Ltd.
- 10 December 2014
- Published by Wiley in Flavour and Fragrance Journal
- Vol. 30 (2) , 160-164
Determination of volatile ‘restricted substances’ in flavourings and their volatile raw materials by GC‐MS
Many flavour regulations around the world contain a list of so‐called ‘restricted substances’ (RS), i.e. substances that occur naturally in source materials for flavourings and food ingredients with flavouring properties, but whose presence in certain foods is restricted and/or for which maximum levels are set, for example, the European regulation 1334/2008. Only a few publications refer to the determination of RS in compound flavourings or their raw materials, and the latter only concern the analysis of one or two individual RS in single essential oils. The Working Group on Methods of Analysis of the International Organization of the Flavor Industry (IOFI) has developed a method for the rapid routine determination of β‐asarone, coumarin, menthofuran, methylchavicol, methyleugenol, pulegone, safrole and α‐ and β‐thujones in flavourings and their raw materials by gas chromatography‐mass spectrometry (GC‐MS), using selected‐ion monitoring and internal standards. The method has been evaluated by nine flavour‐industry laboratories using a complex surrogate flavouring containing all of the above analytes, at concentrations that would be likely to produce levels in finished foods of around typical maximum limits for these RS. Results were obtained from a total of 15 columns and sets of analytical conditions, using 11 GC/MS instruments, with in each case a determination of the analyte in two versions of the flavouring. With reproducibility relative standard deviations (RSDR) of less than about 20%, and recoveries of 80–120%, the method performance can be considered as satisfactory for rapid routine checks on the levels of restricted substances in compound flavourings. The method is intended for flavour‐industry laboratories in order for them to fulfil their obligation to inform food‐industry clients of the amounts of these substances in commercial flavourings, but is not intended for their analysis in finished foods. Copyright © 2014 John Wiley & Sons, Ltd.
- 10 December 2014
- Published by Wiley in Flavour and Fragrance Journal
- Vol. 30 (2) , 160-164
Determination of volatile ‘restricted substances’ in flavourings and their volatile raw materials by GC‐MS
Many flavour regulations around the world contain a list of so‐called ‘restricted substances’ (RS), i.e. substances that occur naturally in source materials for flavourings and food ingredients with flavouring properties, but whose presence in certain foods is restricted and/or for which maximum levels are set, for example, the European regulation 1334/2008. Only a few publications refer to the determination of RS in compound flavourings or their raw materials, and the latter only concern the analysis of one or two individual RS in single essential oils. The Working Group on Methods of Analysis of the International Organization of the Flavor Industry (IOFI) has developed a method for the rapid routine determination of β‐asarone, coumarin, menthofuran, methylchavicol, methyleugenol, pulegone, safrole and α‐ and β‐thujones in flavourings and their raw materials by gas chromatography‐mass spectrometry (GC‐MS), using selected‐ion monitoring and internal standards. The method has been evaluated by nine flavour‐industry laboratories using a complex surrogate flavouring containing all of the above analytes, at concentrations that would be likely to produce levels in finished foods of around typical maximum limits for these RS. Results were obtained from a total of 15 columns and sets of analytical conditions, using 11 GC/MS instruments, with in each case a determination of the analyte in two versions of the flavouring. With reproducibility relative standard deviations (RSDR) of less than about 20%, and recoveries of 80–120%, the method performance can be considered as satisfactory for rapid routine checks on the levels of restricted substances in compound flavourings. The method is intended for flavour‐industry laboratories in order for them to fulfil their obligation to inform food‐industry clients of the amounts of these substances in commercial flavourings, but is not intended for their analysis in finished foods. Copyright © 2014 John Wiley & Sons, Ltd.
- Open Access
- 4 April 2012
- Published by Wiley in Flavour and Fragrance Journal
- Vol. 27 (3) , 224-226
IOFI recommended practice for the quantitative analysis of volatile flavouring substances using coupled gas chromatography/mass spectrometry with selected‐ion monitoring (SIM)
The present recommended practice concerns the quantification of volatile flavouring substances by coupled gas chromatography/mass spectrometry with selected‐ion monitoring (SIM). This technique is especially suitable for unresolved peaks in classical gas chromatography (e.g. quantification in a complex chromatogram) and is more sensitive than the use of the mass spectrometer in the full‐scan mode. Copyright © 2012 John Wiley & Sons, Ltd.
- 4 April 2012
- Published by Wiley in Flavour and Fragrance Journal
- Vol. 27 (3) , 224-226
Open AccessIOFI recommended practice for the quantitative analysis of volatile flavouring substances using coupled gas chromatography/mass spectrometry with selected‐ion monitoring (SIM)
The present recommended practice concerns the quantification of volatile flavouring substances by coupled gas chromatography/mass spectrometry with selected‐ion monitoring (SIM). This technique is especially suitable for unresolved peaks in classical gas chromatography (e.g. quantification in a complex chromatogram) and is more sensitive than the use of the mass spectrometer in the full‐scan mode. Copyright © 2012 John Wiley & Sons, Ltd.
- Open Access
- 5 April 2010
- Published by Wiley in Flavour and Fragrance Journal
- Vol. 25 (6) , 404-406
Guidelines for solid‐phase micro‐extraction (SPME) of volatile flavour compounds for gas‐chromatographic analysis, from the Working Group on Methods of Analysis of the International Organization of the Flavor Industry (IOFI)
- 5 April 2010
- Published by Wiley in Flavour and Fragrance Journal
- Vol. 25 (6) , 404-406
Open AccessGuidelines for solid‐phase micro‐extraction (SPME) of volatile flavour compounds for gas‐chromatographic analysis, from the Working Group on Methods of Analysis of the International Organization of the Flavor Industry (IOFI)
- Open Access
- 23 November 2009
- Published by Wiley in Flavour and Fragrance Journal
- Vol. 25 (1) , 2-3
Guidelines for LC–MS identifications of flavouring substances in nature, made by the Working Group on Methods of Analysis of the International Organization of the Flavor Industry (IOFI)
- 23 November 2009
- Published by Wiley in Flavour and Fragrance Journal
- Vol. 25 (1) , 2-3
Open AccessGuidelines for LC–MS identifications of flavouring substances in nature, made by the Working Group on Methods of Analysis of the International Organization of the Flavor Industry (IOFI)