JSJan-Marten Seitz

Jan-Marten Seitz

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Jan-Marten Seitz has a total of 19 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    The influence of storage and heat treatment on a magnesium-based implant material: an in vitro and in vivo study

    by Katja Bracht, Nina Angrisani, Jan-Marten Seitz, Rainer Eifler, Andreas Weizbauer, Janin Reifenrath

    Magnesium alloys are recommended as a potential material for osteosynthesis. It is known that storage-induced property modifications can occur in materials like aluminum. Thus the aim of this study was to analyze the influence of storage durations of up to 48 weeks on the biomechanical, structural, and degradation properties of the degradable magnesium alloy LAE442. Extruded implants (n = 104; Ø 2.5 mm × 25 mm) were investigated after storage periods of 0, 12, 24, and 48 weeks in three different sub-studies: (I) immediately after the respective storage duration and after an additional (II) 56 days of in vitro corrosion in simulated body fluid (SFB), and (III) 48 weeks in vivo corrosion in a rabbit model, respectively. In addition, the influence of a T5-heat treatment (206 °C for 15 h in an argon atmosphere) was tested (n = 26; 0 week of storage). Evaluation was performed by three-point bending, scanning electron microscopy, radiography, µ-computed tomography, evaluation of the mean grain size, and contrast analysis of precipitations (such as aluminum or lithium). The heat treatment induced a significant reduction in initial stability, and enhanced the corrosion resistance. In vivo experiments showed a good biocompatibility for all implants. During the storage of up to 48 weeks, no significant changes occurred in the implant properties. LAE442 implants can be safely used after up to 48 weeks of storage.


  • In vivo evaluation of a magnesium-based degradable intramedullary nailing system in a sheep model

    by Christina Rössig, Nina Angrisani, Patrick Helmecke, Silke Besdo, Jan-Marten Seitz, Bastian Welke, Nickolay Fedchenko, Heiko Kock, Janin Reifenrath


  • Top Cited Papers

    Recent Advances in Biodegradable Metals for Medical Sutures: A Critical Review

    by Jan‐Marten Seitz, Martin Durisin, Jeremy Goldman, Jaroslaw W. Drelich

    Sutures that biodegrade and dissolve over a period of several weeks are in great demand to stitch wounds and surgical incisions. These new materials are receiving increased acceptance across surgical procedures whenever permanent sutures and long‐term care are not needed. Unfortunately, both inflammatory responses and adverse local tissue reactions in the close‐to‐stitching environment are often reported for biodegradable polymeric sutures currently used by the medical community. While bioabsorbable metals are predominantly investigated and tested for vascular stent or osteosynthesis applications, they also appear to possess adequate bio­compatibility, mechanical properties, and corrosion stability to replace biodegradable polymeric sutures. In this Review, biodegradable alloys made of iron, magnesium, and zinc are critically evaluated as potential materials for the manufacturing of soft and hard tissue sutures. In the case of soft tissue closing and stitching, these metals have to compete against currently available degradable polymers. In the case of hard tissue closing and stitching, biodegradable sternal wires could replace the permanent sutures made of stainless steel or titanium alloys. This Review discusses the specific materials and degradation properties required by all suture materials, summarizes current suture testing protocols and provides a well‐grounded direction for the potential future development of biodegradable metal based sutures.


  • In vivodegradation effects of alloy MgNd2 in contact with mucous tissue

    by J.-M. Seitz, R. Eifler, C. Weber, T. H. Lenarz, H. J. Maier, M. Durisin