Ismail Abustan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Ismail Abustan has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
Hussam El Najar
Islamic University in Gaza
2 shared publications- Mohd Ashraf Mohamad Ismail
School of Civil Engineering, Engineering Campus, Universiti Sains Malaysia, Nibong Tebal 14300, Seberang Prai Selatan, Pulau Pinang, Malaysia
2 shared publications Mohd Remy Rozaimy
Universiti Sains Malaysia
2 shared publicationsMohd S. Abu Jabal
Universiti Sains Malaysia
2 shared publicationsA Saleh
School of Civil Engineering Engineering Campus Universiti Sains Malaysia Nibong Tebal 14300 Penang Malaysia
1 shared publication- Azlan Saleh
Disaster Preparedness and Prevention Centre (DPPC), Malaysia-Japan International Institute of Technology (MJIIT), Universiti Teknologi Malaysia Kuala Lumpur, Jalan Sultan Yahya Petra, Kuala Lumpur, Malaysia
1 shared publication
Latest Publications
- 1 December 2020
- Published by Geological Society of India in Journal of the Geological Society of India
- Vol. 96 (6) , 616-622
Development of Groundwater Level Fluctuation Response System Subjected to Rainfall for Slope Stability Forecasting
The rise of groundwater level in slope due to intense rainfall is one of the factors that can trigger slope failure. The groundwater level rise causes increase in the pore water pressure thus reducing the shear resistance of the soil. The purpose of this study is to present a groundwater level evaluation system in response to daily rainfall for slope stability forecasting. The system consists of three important components namely the conceptual multi tank model, unsaturated-saturated seepage flow analysis and stability analysis. The conceptual multi tank model was initially used to determine the fluctuations of groundwater level followed by the unsaturated-saturated seepage flow analysis to determine the pore water pressure distribution in the slope. Finally, the variation in factor of safety for the slope was determined by stability analysis corresponding to the seepage flow results. The performance of the evaluation system was demonstrated using a case study in Putrajaya, Malaysia. From this study, an early warning system can be developed for slope stability which is essential for disaster prevention during rainfall.
- 1 December 2020
- Published by Geological Society of India in Journal of the Geological Society of India
- Vol. 96 (6) , 616-622
Development of Groundwater Level Fluctuation Response System Subjected to Rainfall for Slope Stability Forecasting
The rise of groundwater level in slope due to intense rainfall is one of the factors that can trigger slope failure. The groundwater level rise causes increase in the pore water pressure thus reducing the shear resistance of the soil. The purpose of this study is to present a groundwater level evaluation system in response to daily rainfall for slope stability forecasting. The system consists of three important components namely the conceptual multi tank model, unsaturated-saturated seepage flow analysis and stability analysis. The conceptual multi tank model was initially used to determine the fluctuations of groundwater level followed by the unsaturated-saturated seepage flow analysis to determine the pore water pressure distribution in the slope. Finally, the variation in factor of safety for the slope was determined by stability analysis corresponding to the seepage flow results. The performance of the evaluation system was demonstrated using a case study in Putrajaya, Malaysia. From this study, an early warning system can be developed for slope stability which is essential for disaster prevention during rainfall.
- Open Access
- 8 January 2020
- Published by IntechOpen
Application of Artificial Barrier as Mitigation ofE. coliWhich Pass through Riverbank Filtration
Water security in the water treatment plant has been doubted, and the treatment process may have given unreliable and unsafe water to the public. A newspaper reported on November 19, 2011, that laboratory tests on water samples in Kelantan for each year by the Ministry of Health have found harmful bacteria including Escherichia coli (E. coli) in the water samples. More worryingly, it was stated in a study that chlorine in water treated with high chlorine can be harmful to human health. In 2010, Malaysia has begun to approach a natural treatment technique, namely, riverbank filtration (RBF), and firstly used it at the Water Treatment Plant in Jeli, Kelantan, and Kuala Kangsar, Perak. RBF limitation is the invisible groundwater flow that makes it difficult to predict the transport of contaminants. Managing groundwater is important to ensure that water is aligned in compliance with government legislation and environmental protection. Due to that, this study suggests an implementation of an artificial barrier for microorganism in RBF to sustain the good water quality abstracted from the abstraction well. This pretreatment or purifying method is to improve the effectiveness of RBF in removing pollutants during shock loads and reduce the load placed in the water treatment process.
- 8 January 2020
- Published by IntechOpen
Open AccessApplication of Artificial Barrier as Mitigation ofE. coliWhich Pass through Riverbank Filtration
Water security in the water treatment plant has been doubted, and the treatment process may have given unreliable and unsafe water to the public. A newspaper reported on November 19, 2011, that laboratory tests on water samples in Kelantan for each year by the Ministry of Health have found harmful bacteria including Escherichia coli (E. coli) in the water samples. More worryingly, it was stated in a study that chlorine in water treated with high chlorine can be harmful to human health. In 2010, Malaysia has begun to approach a natural treatment technique, namely, riverbank filtration (RBF), and firstly used it at the Water Treatment Plant in Jeli, Kelantan, and Kuala Kangsar, Perak. RBF limitation is the invisible groundwater flow that makes it difficult to predict the transport of contaminants. Managing groundwater is important to ensure that water is aligned in compliance with government legislation and environmental protection. Due to that, this study suggests an implementation of an artificial barrier for microorganism in RBF to sustain the good water quality abstracted from the abstraction well. This pretreatment or purifying method is to improve the effectiveness of RBF in removing pollutants during shock loads and reduce the load placed in the water treatment process.
- 29 November 2019
- Published by Springer Nature
- p. 1629-1642
Flood Hazard Map of Upper Sungai Langat Using HEC-RAS
- 29 November 2019
- Published by Springer Nature
- p. 1629-1642
Flood Hazard Map of Upper Sungai Langat Using HEC-RAS
- Open Access
- 22 May 2018
- Published by Science Publishing Corporation in International Journal of Engineering & Technology
- Vol. 7 (2.29) , 849-852
Sediment Transport and Characteristics in Perak River and Kurau River
Particle size is the most important parameter to deal in sediment transport processes. This parameter is important to determine the class of sediment transport in river. It is also important for the selection of site for sand mining operation through the determination of the size of sediment, sediment capacity and sediment replenishment rate. Data were obtained through observations made from two rivers namely Sungai Perak and Sungai Kurau in Malaysia. The rivers were categorized as wide river for Sungai Perak and small river for Sungai Kurau. For Sungai Perak, the width of river ranges from 248.18 to 338.53 meter whilst the width of Sungai Kurau ranges from 9 to 11 meter. Data covers flow discharges from 130.988 m3/s to 435.915 m3/s for Sungai Perak and from 2.52 m3/s to 4.723 m3/s for Sungai Kurau. Based on the results, the bed load of two rivers are found to be mostly uniform mixture. The results indicate that these two Malaysian rivers mostly have uniform bed load The bed material for the two rivers are poorly graded mixture and the median size of bed loads mostly ranges from 0.62 to 2.94 mm.
- 22 May 2018
- Published by Science Publishing Corporation in International Journal of Engineering & Technology
- Vol. 7 (2.29) , 849-852
Open AccessSediment Transport and Characteristics in Perak River and Kurau River
Particle size is the most important parameter to deal in sediment transport processes. This parameter is important to determine the class of sediment transport in river. It is also important for the selection of site for sand mining operation through the determination of the size of sediment, sediment capacity and sediment replenishment rate. Data were obtained through observations made from two rivers namely Sungai Perak and Sungai Kurau in Malaysia. The rivers were categorized as wide river for Sungai Perak and small river for Sungai Kurau. For Sungai Perak, the width of river ranges from 248.18 to 338.53 meter whilst the width of Sungai Kurau ranges from 9 to 11 meter. Data covers flow discharges from 130.988 m3/s to 435.915 m3/s for Sungai Perak and from 2.52 m3/s to 4.723 m3/s for Sungai Kurau. Based on the results, the bed load of two rivers are found to be mostly uniform mixture. The results indicate that these two Malaysian rivers mostly have uniform bed load The bed material for the two rivers are poorly graded mixture and the median size of bed loads mostly ranges from 0.62 to 2.94 mm.
- Open Access
- 11 April 2018
- Published by IOP Publishing in IOP Conference Series: Earth and Environmental Science
- Vol. 140 (1) , 012011
Removal of Escherichia coli via low frequency electromagnetic field in riverbank filtration system.
The removal of Escherichia coli (E. coli) via low frequency of electromagnetic field (LF-EMF) with different magnetic field was studied. LF-EMF is known as a high magnetic susceptibility method, which could affect E. coli growth without the usage of chemicals. The aim of this study was to investigate the removal of E. coli by using LF-EMF in water abstraction for the riverbank filtration (RBF) application. The effect of LF-EMF with the intensity of 2 to 10mT and 50Hz on coiled column of 1mm copper wire at 1 to 6 hours was assessed. The removal of E. coli after exposing to LF-EMF on the column model was measured using most probable number (MPN/100mL) and colonies forming unit (CFU/100mL) methods. Water flows into the column were varied up to 6 hours and with flowrate of 100 mL/min. Experimental results demonstrate that 100% of E. coli was removed at 8mT after 6 hours exposure. The magnetic field at 10mT removed 100% of E. coli after 4 hours exposure. The results obtained in this study proved that the LF-EMF was efficient in E. coli removal from RBF system. These finding indicated that the LF-EMF intensities and time of exposure can affect the removal of E. coli.
- 11 April 2018
- Published by IOP Publishing in IOP Conference Series: Earth and Environmental Science
- Vol. 140 (1) , 012011
Open AccessRemoval of Escherichia coli via low frequency electromagnetic field in riverbank filtration system.
The removal of Escherichia coli (E. coli) via low frequency of electromagnetic field (LF-EMF) with different magnetic field was studied. LF-EMF is known as a high magnetic susceptibility method, which could affect E. coli growth without the usage of chemicals. The aim of this study was to investigate the removal of E. coli by using LF-EMF in water abstraction for the riverbank filtration (RBF) application. The effect of LF-EMF with the intensity of 2 to 10mT and 50Hz on coiled column of 1mm copper wire at 1 to 6 hours was assessed. The removal of E. coli after exposing to LF-EMF on the column model was measured using most probable number (MPN/100mL) and colonies forming unit (CFU/100mL) methods. Water flows into the column were varied up to 6 hours and with flowrate of 100 mL/min. Experimental results demonstrate that 100% of E. coli was removed at 8mT after 6 hours exposure. The magnetic field at 10mT removed 100% of E. coli after 4 hours exposure. The results obtained in this study proved that the LF-EMF was efficient in E. coli removal from RBF system. These finding indicated that the LF-EMF intensities and time of exposure can affect the removal of E. coli.
- 21 February 2018
- Published by Springer Nature in Environmental Earth Sciences
- Vol. 77 (4) , 155
The deuterium and oxygen-18 isotopic composition of the groundwater in Khan Younis City, southern Gaza Strip (Palestine)
- 21 February 2018
- Published by Springer Nature in Environmental Earth Sciences
- Vol. 77 (4) , 155
The deuterium and oxygen-18 isotopic composition of the groundwater in Khan Younis City, southern Gaza Strip (Palestine)
- 13 June 2017
- Published by Springer Nature in Arabian Journal of Geosciences
- Vol. 10 (12)
Groundwater beneath the urban area of Khan Younis City, southern Gaza Strip (Palestine): assessment for multi-domestic purposes
- 13 June 2017
- Published by Springer Nature in Arabian Journal of Geosciences
- Vol. 10 (12)
Groundwater beneath the urban area of Khan Younis City, southern Gaza Strip (Palestine): assessment for multi-domestic purposes
- 1 January 2017
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1892, 070002
Assessment of total bed material equations on selected Malaysia rivers
Assessment of total sediment load equations on selected Malaysia rivers was done based on 35 sediment loads and hydraulic data. Four rivers were selected to make this assessment which are Sungai Perak, Sungai Kemaman, Sungai Pergau and Sungai Kurau. These rivers can be divided into three categories based on the river width, with Sungai Perak (300-350m) and Sungai Kemaman (150-200m) can categorised as big rivers, meanwhile, Sungai Pergau (30-45m) and Sungai Kurau (10-11m) can categorised as medium and small river respectively. The total sediment load equations used in this assessment are Ackers-White, Brownlie, Engelund-Hansen, Graf, Molinas-Wu, Karim-Kennedy and Yang. This paper also tested the local total sediment load equations by Ariffin and Sinnakaudan et al. to evaluate capabilities of the equations on different rivers in Malaysia. The graphs of the calculated equations versus measured sediment transport rates were plotted to shows the accuracy of the tested equations.
- 1 January 2017
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1892, 070002
Assessment of total bed material equations on selected Malaysia rivers
Assessment of total sediment load equations on selected Malaysia rivers was done based on 35 sediment loads and hydraulic data. Four rivers were selected to make this assessment which are Sungai Perak, Sungai Kemaman, Sungai Pergau and Sungai Kurau. These rivers can be divided into three categories based on the river width, with Sungai Perak (300-350m) and Sungai Kemaman (150-200m) can categorised as big rivers, meanwhile, Sungai Pergau (30-45m) and Sungai Kurau (10-11m) can categorised as medium and small river respectively. The total sediment load equations used in this assessment are Ackers-White, Brownlie, Engelund-Hansen, Graf, Molinas-Wu, Karim-Kennedy and Yang. This paper also tested the local total sediment load equations by Ariffin and Sinnakaudan et al. to evaluate capabilities of the equations on different rivers in Malaysia. The graphs of the calculated equations versus measured sediment transport rates were plotted to shows the accuracy of the tested equations.
- 1 January 2017
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1892, 040011
Effect of low-frequency electromagnetic fields on the Escherichia coli growth for application in riverbank filtration
A 50 Hz low-frequency electromagnetic field (LF-EMF) could give removal effect on the growth of Escherichia coli (E. coli) in the riverbank filtration (RBF) was studied. The LF-EMF strengths were varied from 2 to 10 mT using coil column induce magnetic fields. For this study, two different columns with a diameter of 50 mm and 80 mm were applied; 1.5mm copper wires with the number of turns between 300 to 600 turns. Water samples were flowed into the column at flowrate of 50mL/min with temperature in range of 28–30°C. This study, it was found that the LF-EMF has significant removal effects on E. coli growth, where the removal of 100% of E. coli at 6 mT and 8 mT after 6 hrs exposed. Moreover, for shorter exposure period of 3 hrs exposed, 82% of E. coli removal were detected in 80 mm column for 8 mT and 10 mT magnetic field. These findings indicate that the application of LF-EMF is able to decrease the E. coli, can be and efficient in E. coli growth from river water intake. Thus, the results from this study proved that the utilization of LF-EMF is able to decrease the concentrations of E. coli, and contributes in slowing down their growth. Also, it can be indicated that the LF-EMF kill a part of E. coli exposed in the river water with the large magnetic field and long-time exposure.
- 1 January 2017
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1892, 040011
Effect of low-frequency electromagnetic fields on the Escherichia coli growth for application in riverbank filtration
A 50 Hz low-frequency electromagnetic field (LF-EMF) could give removal effect on the growth of Escherichia coli (E. coli) in the riverbank filtration (RBF) was studied. The LF-EMF strengths were varied from 2 to 10 mT using coil column induce magnetic fields. For this study, two different columns with a diameter of 50 mm and 80 mm were applied; 1.5mm copper wires with the number of turns between 300 to 600 turns. Water samples were flowed into the column at flowrate of 50mL/min with temperature in range of 28–30°C. This study, it was found that the LF-EMF has significant removal effects on E. coli growth, where the removal of 100% of E. coli at 6 mT and 8 mT after 6 hrs exposed. Moreover, for shorter exposure period of 3 hrs exposed, 82% of E. coli removal were detected in 80 mm column for 8 mT and 10 mT magnetic field. These findings indicate that the application of LF-EMF is able to decrease the E. coli, can be and efficient in E. coli growth from river water intake. Thus, the results from this study proved that the utilization of LF-EMF is able to decrease the concentrations of E. coli, and contributes in slowing down their growth. Also, it can be indicated that the LF-EMF kill a part of E. coli exposed in the river water with the large magnetic field and long-time exposure.
- Open Access
- 1 September 2015
- Published by Elsevier in KSCE Journal of Civil Engineering
- Vol. 19 (6) , 1865-1869
A preliminary study of continuous discharge flow from horizontal drains using 3-dimensional resistivity model
- 1 September 2015
- Published by Elsevier in KSCE Journal of Civil Engineering
- Vol. 19 (6) , 1865-1869
Open AccessA preliminary study of continuous discharge flow from horizontal drains using 3-dimensional resistivity model