Sumio Kawano
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Sumio Kawano has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
Piyamart Jannok
Faculty of Agriculture, Kagoshima University, Kagoshima, Japan
2 shared publicationsYoshinori Kamitani
Faculty of Agriculture, Kagoshima University, Kagoshima, Japan
2 shared publicationsKazunori Hironaka
Postharvest Technology Laboratory, University of the Ryukyus, Okinawa, Japan
1 shared publicationMichio Shibayama
Faculty of Agriculture, Kagoshima University, Kagoshima, Japan
1 shared publicationRon Haff
USDA, ARS, Western Region Research Center, Albany, CA, USA
1 shared publicationRudiati Evi Masithoh
National Food Research Institute, NARO, 2-1-12 Kannondai, Tsukuba 305-8642, Japan
1 shared publication
Latest Publications
- 1 February 2017
- Published by SAGE Publications in Journal of Near Infrared Spectroscopy
- Vol. 25 (1) , 26-35
Development of a near infrared calibration model with temperature compensation using common temperature-difference spectra for determining the Brix value of intact fruits
In order to create a calibration model with temperature compensation, the calibration method using the partial least squares regression based on the combined spectra measured at some different temperatures is promising. However, the method is time-consuming since it requires spectra acquisition at different temperatures. In addition, the sample quality may change during the period for the different temperature adjustment of samples. The spectra of the target fruit species of peaches, pears, and persimmons were measured at 25℃ using the interactance method. Spectra for 20℃ and 30℃ were created artificially using temperature-difference second derivative spectra from the 25℃-second derivative spectra. Then, the possibility of temperature-difference second derivative spectra of fruit(s) to create the correct 20℃ and 30℃ artificial second derivative spectra was evaluated. The temperature-difference second derivative spectra created from each target fruit species could be useful for each target fruit species while the common temperature-difference second derivative spectra created from the three target fruit species were useful for not only each target fruit species but also the other fruit species of apples. The calibration model for apples developed using the common temperature-difference second derivative spectra showed low standard error of performance and bias of 0.45°Brix and 0.09°Brix, respectively. The model could be applied well to the prediction sets of apples at 20℃, 25℃, and 30℃ with non-significant biases.
- 1 February 2017
- Published by SAGE Publications in Journal of Near Infrared Spectroscopy
- Vol. 25 (1) , 26-35
Development of a near infrared calibration model with temperature compensation using common temperature-difference spectra for determining the Brix value of intact fruits
In order to create a calibration model with temperature compensation, the calibration method using the partial least squares regression based on the combined spectra measured at some different temperatures is promising. However, the method is time-consuming since it requires spectra acquisition at different temperatures. In addition, the sample quality may change during the period for the different temperature adjustment of samples. The spectra of the target fruit species of peaches, pears, and persimmons were measured at 25℃ using the interactance method. Spectra for 20℃ and 30℃ were created artificially using temperature-difference second derivative spectra from the 25℃-second derivative spectra. Then, the possibility of temperature-difference second derivative spectra of fruit(s) to create the correct 20℃ and 30℃ artificial second derivative spectra was evaluated. The temperature-difference second derivative spectra created from each target fruit species could be useful for each target fruit species while the common temperature-difference second derivative spectra created from the three target fruit species were useful for not only each target fruit species but also the other fruit species of apples. The calibration model for apples developed using the common temperature-difference second derivative spectra showed low standard error of performance and bias of 0.45°Brix and 0.09°Brix, respectively. The model could be applied well to the prediction sets of apples at 20℃, 25℃, and 30℃ with non-significant biases.
- Open Access
- 1 January 2016
- Published by SAGE Publications in Journal of Near Infrared Spectroscopy
- Vol. 24 (1) , 83-88
Determination of Soluble Solids Content and Titratable Acidity of Intact Fruit and Juice of Satsuma Mandarin Using a Hand-Held near Infrared Instrument in Transmittance Mode
Determination of soluble solids content ( SSC) and titratable acidity ( TA) of intact fruit and juice of satsuma mandarin was carried out using a hand-held near infrared instrument (“NIR-Gun”) in transmittance mode. The resulting calibration model measured SSC in intact fruit and juice with a standard error of prediction ( SEP) of 0.33 °Bx and 0.42 °Bx, respectively. TA measurements yielded SEP values of 0.22% and 0.14% for intact fruit and juice, respectively.
- 1 January 2016
- Published by SAGE Publications in Journal of Near Infrared Spectroscopy
- Vol. 24 (1) , 83-88
Open AccessDetermination of Soluble Solids Content and Titratable Acidity of Intact Fruit and Juice of Satsuma Mandarin Using a Hand-Held near Infrared Instrument in Transmittance Mode
Determination of soluble solids content ( SSC) and titratable acidity ( TA) of intact fruit and juice of satsuma mandarin was carried out using a hand-held near infrared instrument (“NIR-Gun”) in transmittance mode. The resulting calibration model measured SSC in intact fruit and juice with a standard error of prediction ( SEP) of 0.33 °Bx and 0.42 °Bx, respectively. TA measurements yielded SEP values of 0.22% and 0.14% for intact fruit and juice, respectively.
- 1 January 2014
- Published by SAGE Publications in Journal of Near Infrared Spectroscopy
- Vol. 22 (5) , 367-373
Development of a Common Calibration Model for Determining the Brix Value of Intact Apple, Pear and Persimmon Fruits by near Infrared Spectroscopy
Calibrations developed using near infrared (NIR) spectroscopy to determine the quality of fruits or vegetables are usually applicable to a single species. The ability to determine the quality of several species using a common calibration would have advantages in some situations. A method to develop a common NIR calibration model that could be applied to many fruit species was examined. NIR spectra of apples, pears and persimmons were measured in the short-wavelength region using an interactance method. Partial least-squares (PLS) regressions based on second-derivative spectra were performed for Brix-value determination using calibration samples comprising each fruit species independently and the three species combined. Each single species calibration model predicted the Brix value in validation samples of the same species with a low standard error of performance ( SEP) (0.34–0.40°Brix (°Bx) and with low bias (0.01–0.08 °Bx) but with much higher SEP and bias errors when used to predict the Brix value in other species. The common calibration model developed from the combined sample set predicted Brix values in the apples, pears and persimmons with an SEP = 0.43 °Bx and a bias of −0.03 °Bx.
- 1 January 2014
- Published by SAGE Publications in Journal of Near Infrared Spectroscopy
- Vol. 22 (5) , 367-373
Development of a Common Calibration Model for Determining the Brix Value of Intact Apple, Pear and Persimmon Fruits by near Infrared Spectroscopy
Calibrations developed using near infrared (NIR) spectroscopy to determine the quality of fruits or vegetables are usually applicable to a single species. The ability to determine the quality of several species using a common calibration would have advantages in some situations. A method to develop a common NIR calibration model that could be applied to many fruit species was examined. NIR spectra of apples, pears and persimmons were measured in the short-wavelength region using an interactance method. Partial least-squares (PLS) regressions based on second-derivative spectra were performed for Brix-value determination using calibration samples comprising each fruit species independently and the three species combined. Each single species calibration model predicted the Brix value in validation samples of the same species with a low standard error of performance ( SEP) (0.34–0.40°Brix (°Bx) and with low bias (0.01–0.08 °Bx) but with much higher SEP and bias errors when used to predict the Brix value in other species. The common calibration model developed from the combined sample set predicted Brix values in the apples, pears and persimmons with an SEP = 0.43 °Bx and a bias of −0.03 °Bx.