Jiho Lee
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jiho Lee has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
Tae Kuk Ko
8 shared publications- Young Jin Hwang
Division of Electronics and Electrical Information Engineering, Korea Maritime & Ocean University, Busan, South Korea
4 shared publications - Woo Seung Lee
Korea Basic Science Institute, Cheongju-si, South Korea
3 shared publications - Yoon Do Chung
Dept. of Electrical Engineering, Suwon Science College, Gyeonggi-do, Korea
2 shared publications Chang Young Lee
1 shared publication- Dong Jin Yoo
Graduate School, Department of Energy Storage/Conversion Engineering (BK21 FOUR), Hydrogen and Fuel Cell Research Center, Jeonbuk National University, 567 Baekje-daero, Deokjin-gu, Jeonju-si, Jeollabuk-do 54896, Republic of Korea
1 shared publication
Latest Publications
- 30 June 2015
- Published by The Korea Institute of Applied Superconductivity and Cryogenics in Progress in Superconductivity and Cryogenics
- Vol. 17 (2) , 41-44
Statistical analysis for HTS coil considering inhomogeneous Icdistribution of HTS tape
- 30 June 2015
- Published by The Korea Institute of Applied Superconductivity and Cryogenics in Progress in Superconductivity and Cryogenics
- Vol. 17 (2) , 41-44
Statistical analysis for HTS coil considering inhomogeneous Icdistribution of HTS tape
- 6 February 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 24 (3) , 1-5
Experimental Study on Low-Pass Filtering Characteristic of Axial Magnetic Field of No-Insulation and Partial-Insulation HTS Coils Carrying a DC-Biased AC Current
This paper deals with the low-pass filtering characteristic of the axial magnetic field of no-insulation and partial-insulation high temperature superconducting (HTS) coils carrying a dc-biased ac current. Recently, the no-insulation winding technique has been issued as a key technique to enhance the performance of HTS coils in terms of the overall current density, thermal stability, and mechanical integrity. In this paper, to verify the effect of time-varying external distortion on no-insulation HTS coils, an experimental analysis is carried on three HTS coils-insulation, no-insulation, and partial-insulation coils. To simulate the environment in which time-varying external distortion influences the HTS coils, a dc-biased ac current is carried by the HTS coils. The axial magnetic fields of no-insulation, partial insulation, and insulation HTS coils are experimentally tested and analyzed. When the coils carry a dc-biased ac current, the no-insulation and partial-insulation coils have a tendency to attenuate the high-frequency components and to act as a low-pass filter on the axial magnetic field; however, the insulation coil does not attenuate the high-frequency components of the axial magnetic field. The analysis of the experimental results can be useful data for the adoption of no-insulation and partial-insulation windings in superconducting applications.
- 6 February 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 24 (3) , 1-5
Experimental Study on Low-Pass Filtering Characteristic of Axial Magnetic Field of No-Insulation and Partial-Insulation HTS Coils Carrying a DC-Biased AC Current
This paper deals with the low-pass filtering characteristic of the axial magnetic field of no-insulation and partial-insulation high temperature superconducting (HTS) coils carrying a dc-biased ac current. Recently, the no-insulation winding technique has been issued as a key technique to enhance the performance of HTS coils in terms of the overall current density, thermal stability, and mechanical integrity. In this paper, to verify the effect of time-varying external distortion on no-insulation HTS coils, an experimental analysis is carried on three HTS coils-insulation, no-insulation, and partial-insulation coils. To simulate the environment in which time-varying external distortion influences the HTS coils, a dc-biased ac current is carried by the HTS coils. The axial magnetic fields of no-insulation, partial insulation, and insulation HTS coils are experimentally tested and analyzed. When the coils carry a dc-biased ac current, the no-insulation and partial-insulation coils have a tendency to attenuate the high-frequency components and to act as a low-pass filter on the axial magnetic field; however, the insulation coil does not attenuate the high-frequency components of the axial magnetic field. The analysis of the experimental results can be useful data for the adoption of no-insulation and partial-insulation windings in superconducting applications.
- Open Access
- 1 January 2014
- Published by Elsevier in Physics Procedia
- Vol. 58, 268-271
Experimental Study on Current Decay Characteristics of Persistent Current HTS Magnet by Alternating Magnetic Field
- 1 January 2014
- Published by Elsevier in Physics Procedia
- Vol. 58, 268-271
Open AccessExperimental Study on Current Decay Characteristics of Persistent Current HTS Magnet by Alternating Magnetic Field
- 11 November 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 24 (3) , 1-5
Estimation of the Engineering Critical Current Criteria for HTS Wire Carrying an Alternating Current
This paper deals with a method to estimate the engineering critical current criteria for high temperature superconducting (HTS) wire in alternating current (ac) operation. There are plenty of high temperature superconducting devices used in ac operation, such as superconducting fault current limiters and superconducting cables. However, the operating currents of those ac superconducting devices are mostly designated by the critical current measured in direct current operation based on International Electrotechnical Commision (IEC) 61788-3, so the engineering critical current criteria of the HTS wire for ac operation is needed. In this paper, the engineering critical current criteria of HTS wires for ac operation are estimated considering the odd harmonic electric fields, the calculated ac loss, and the temperature. The authors expect that the method and approaches used in this study will help to estimate the engineering critical current and to decide the operating currents of HTS applications.
- 11 November 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 24 (3) , 1-5
Estimation of the Engineering Critical Current Criteria for HTS Wire Carrying an Alternating Current
This paper deals with a method to estimate the engineering critical current criteria for high temperature superconducting (HTS) wire in alternating current (ac) operation. There are plenty of high temperature superconducting devices used in ac operation, such as superconducting fault current limiters and superconducting cables. However, the operating currents of those ac superconducting devices are mostly designated by the critical current measured in direct current operation based on International Electrotechnical Commision (IEC) 61788-3, so the engineering critical current criteria of the HTS wire for ac operation is needed. In this paper, the engineering critical current criteria of HTS wires for ac operation are estimated considering the odd harmonic electric fields, the calculated ac loss, and the temperature. The authors expect that the method and approaches used in this study will help to estimate the engineering critical current and to decide the operating currents of HTS applications.
- 18 October 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 24 (3) , 1-5
Electromagnetic Design of a 15 MW-Class HTS Flux Switching Synchronous Generator considering Mechanical Stress of the Rotor Core
This paper introduces a novel flux switching synchronous generator (FSSG) using high-temperature superconducting (HTS) field coils. Unlike conventional superconducting synchronous generators, the HTS field coils in the proposed FSSG are mounted in the stator and do not rotate during operation. Therefore, the design and fabrication of the cooling and excitation systems for HTS field coils are easier than those for the conventional superconducting synchronous generator. To verify the feasibility of the structure, a 15 MW-class FSSG was designed using a fundamental design methodology considering the mechanical stress of the rotor core. The design methodology uses mechanical and electromagnetic equations. It defines the size of the rotor first using mechanical equations for the rotor and designs the HTS field winding and armature winding using the electromagnetic equations and an FEM analysis. In addition, the operational characteristics of the FSSG were analyzed by a transient motion analysis using the FEM program. This paper could be utilized to develop superconducting synchronous generators.
- 18 October 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 24 (3) , 1-5
Electromagnetic Design of a 15 MW-Class HTS Flux Switching Synchronous Generator considering Mechanical Stress of the Rotor Core
This paper introduces a novel flux switching synchronous generator (FSSG) using high-temperature superconducting (HTS) field coils. Unlike conventional superconducting synchronous generators, the HTS field coils in the proposed FSSG are mounted in the stator and do not rotate during operation. Therefore, the design and fabrication of the cooling and excitation systems for HTS field coils are easier than those for the conventional superconducting synchronous generator. To verify the feasibility of the structure, a 15 MW-class FSSG was designed using a fundamental design methodology considering the mechanical stress of the rotor core. The design methodology uses mechanical and electromagnetic equations. It defines the size of the rotor first using mechanical equations for the rotor and designs the HTS field winding and armature winding using the electromagnetic equations and an FEM analysis. In addition, the operational characteristics of the FSSG were analyzed by a transient motion analysis using the FEM program. This paper could be utilized to develop superconducting synchronous generators.
- Open Access
- 31 March 2013
- Published by The Korea Institute of Applied Superconductivity and Cryogenics in Progress in Superconductivity and Cryogenics
- Vol. 15 (1) , 51-54
Experiment of harmonic components in voltage on high temperature superconducting wire carrying an AC
- 31 March 2013
- Published by The Korea Institute of Applied Superconductivity and Cryogenics in Progress in Superconductivity and Cryogenics
- Vol. 15 (1) , 51-54
Open AccessExperiment of harmonic components in voltage on high temperature superconducting wire carrying an AC