Göran Sjögren
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Göran Sjögren has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
Jiyan Qiao
Institute of Mechanics, Chinese Academy of Sciences, CN-100190, Beijing, China
2 shared publicationsLi Chen
Institute of Mechanics, Chinese Academy of Sciences, CN-100190, Beijing, China
2 shared publicationsWen Kou
Dental Materials Science, Faculty of Medicine, Umeå University, SE-901 87 Umeå, Sweden
2 shared publicationsYansheng Ding
Institute of Mechanics, Chinese Academy of Sciences, CN-100190, Beijing, China
2 shared publicationsA Sundh
Anders Sundh, PhD, DDS, Praktikertjänst AB, Skellefteå, Sweden
1 shared publicationAnders Sundh
Research and Development, Cad.esthetics AB, SE-931 21 Skellefteå, Sweden
1 shared publication
Latest Publications
- 1 November 2019
- Published by Operative Dentistry in Operative Dentistry
- Vol. 44 (6) , 615-624
Effects of Pretreatment, Specimen Thickness, and Artificial Aging on Biaxial Flexural Strength of Two Types of Y-TZP Ceramics
SUMMARY: Objectives: To evaluate the effects of surface treatment, specimen thickness, and aging on the biaxial flexural strength (BFS) of two types of yttria-stabilized, tetragonal zirconia polycrystal (Y-TZP) ceramics.Methods and Materials: Disc-shaped specimens, 0.4 and 1.3 mm thick, made from hot isostatic pressed (Denzir) and non–hot isostatic pressed (ZirPlus) Y-TZP, were sandblasted, heat treated, and autoclaved. The surface topography was assessed in accordance with European Standard 623-624:2004 and the BFS tests in accordance with International Organization for Standardization Standard 6872:2008. For statistical analyses, one-way Shapiro-Wilk test, analysis of variance (post hoc: least significant differences), Mann-Whitney U-test, and Pearson correlation tests (p1.3-mm ZirPlus (p1.3-mm Denzir (p<0.001). Sandblasting with 0.2 MPa reduced the BFS of the ZirPlus and Denzir discs (p<0.01), whereas sandblasting with 0.6 MPa increased the BFS of the 0.4-mm Denzir (p<0.001) and reduced the BFS of the 0.4-mm ZirPlus (p<0.05). Heat treatment significantly reduced the BFS of all the groups except for the 0.6 MPa sandblasted 0.4-mm ZirPlus. Autoclaving reduced the BFS of the as-delivered ZirPlus and Denzir specimens (p0.05) on the BFS. The 0.6 MPa sandblasted, heat-treated, and autoclaved 0.4-mm Denzir exhibited higher BFS than the 0.6 MPa sandblasted, heat-treated, and autoclaved 0.4-mm ZirPlus (p<0.05).Conclusions: Thickness and surface treatment of Y-TZP–based ceramics should be considered since those factors could influence the BFS of the material.
- 1 November 2019
- Published by Operative Dentistry in Operative Dentistry
- Vol. 44 (6) , 615-624
Effects of Pretreatment, Specimen Thickness, and Artificial Aging on Biaxial Flexural Strength of Two Types of Y-TZP Ceramics
SUMMARY: Objectives: To evaluate the effects of surface treatment, specimen thickness, and aging on the biaxial flexural strength (BFS) of two types of yttria-stabilized, tetragonal zirconia polycrystal (Y-TZP) ceramics.Methods and Materials: Disc-shaped specimens, 0.4 and 1.3 mm thick, made from hot isostatic pressed (Denzir) and non–hot isostatic pressed (ZirPlus) Y-TZP, were sandblasted, heat treated, and autoclaved. The surface topography was assessed in accordance with European Standard 623-624:2004 and the BFS tests in accordance with International Organization for Standardization Standard 6872:2008. For statistical analyses, one-way Shapiro-Wilk test, analysis of variance (post hoc: least significant differences), Mann-Whitney U-test, and Pearson correlation tests (p1.3-mm ZirPlus (p1.3-mm Denzir (p<0.001). Sandblasting with 0.2 MPa reduced the BFS of the ZirPlus and Denzir discs (p<0.01), whereas sandblasting with 0.6 MPa increased the BFS of the 0.4-mm Denzir (p<0.001) and reduced the BFS of the 0.4-mm ZirPlus (p<0.05). Heat treatment significantly reduced the BFS of all the groups except for the 0.6 MPa sandblasted 0.4-mm ZirPlus. Autoclaving reduced the BFS of the as-delivered ZirPlus and Denzir specimens (p0.05) on the BFS. The 0.6 MPa sandblasted, heat-treated, and autoclaved 0.4-mm Denzir exhibited higher BFS than the 0.6 MPa sandblasted, heat-treated, and autoclaved 0.4-mm ZirPlus (p<0.05).Conclusions: Thickness and surface treatment of Y-TZP–based ceramics should be considered since those factors could influence the BFS of the material.
- 1 December 2016
- Published by Elsevier in Journal of Dentistry
- Vol. 55, 25-32
Effects of pretreatments and hydrothermal aging on biaxial flexural strength of lithium di-silicate and Mg-PSZ ceramics
- 1 December 2016
- Published by Elsevier in Journal of Dentistry
- Vol. 55, 25-32
Effects of pretreatments and hydrothermal aging on biaxial flexural strength of lithium di-silicate and Mg-PSZ ceramics
- Open Access
- 1 October 2015
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 50, 206-214
Numerical simulation of the fracture process in ceramic FPD frameworks caused by oblique loading
- 1 October 2015
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 50, 206-214
Open AccessNumerical simulation of the fracture process in ceramic FPD frameworks caused by oblique loading
- 1 February 2015
- Published by Elsevier in Dental Materials
- Vol. 31 (2) , 162-170
A retrospective evaluation of zirconia-fixed partial dentures in general practices: An up to 13-year study
- 1 February 2015
- Published by Elsevier in Dental Materials
- Vol. 31 (2) , 162-170
A retrospective evaluation of zirconia-fixed partial dentures in general practices: An up to 13-year study
- 5 January 2011
- Published by Wiley in Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Vol. 96B (2) , 376-385
A 3D numerical simulation of stress distribution and fracture process in a zirconia-based FPD framework
In this study, a numerical approach to the fracture behavior in a three-unit zirconia-based fixed partial denture (FPD) framework was made under mechanical loading using a newly developed three-dimensional (3D) numerical modeling code. All the materials studied were treated heterogeneously and Weibull distribution law was applied to describe the heterogeneity. The Mohr-Coulomb failure criterion with tensile strength cut-off was utilized to judge whether the material was in an elastic or failed state. For validation, the fracture pattern obtained from the numerical modeling was compared with a laboratory test; they largely correlated with each other. Similar fracture initiation sites were detected both in the numerical simulation and in an earlier fractographic analysis. The numerical simulation applied in this study clearly described the stress distribution and fracture process of zirconia-based FPD frameworks, information that could not be gained from the laboratory tests alone. Thus, the newly developed 3D numerical modeling code seems to be an efficient tool for prediction of the fracture process in ceramic FPD frameworks. © 2010 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2011.
- 5 January 2011
- Published by Wiley in Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Vol. 96B (2) , 376-385
A 3D numerical simulation of stress distribution and fracture process in a zirconia-based FPD framework
In this study, a numerical approach to the fracture behavior in a three-unit zirconia-based fixed partial denture (FPD) framework was made under mechanical loading using a newly developed three-dimensional (3D) numerical modeling code. All the materials studied were treated heterogeneously and Weibull distribution law was applied to describe the heterogeneity. The Mohr-Coulomb failure criterion with tensile strength cut-off was utilized to judge whether the material was in an elastic or failed state. For validation, the fracture pattern obtained from the numerical modeling was compared with a laboratory test; they largely correlated with each other. Similar fracture initiation sites were detected both in the numerical simulation and in an earlier fractographic analysis. The numerical simulation applied in this study clearly described the stress distribution and fracture process of zirconia-based FPD frameworks, information that could not be gained from the laboratory tests alone. Thus, the newly developed 3D numerical modeling code seems to be an efficient tool for prediction of the fracture process in ceramic FPD frameworks. © 2010 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2011.