Xiu Yang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Xiu Yang has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Bo Tang
Faculty of Electrical Engineering, Shanghai University of Electric Power, Yangpu District, Shanghai 200090, China
1 shared publication - Chaojun Zheng
School of Electrical Engineering, Shanghai University of Electric Power, Shanghai 200090, China
1 shared publication - Chenyang Zhao
Key Laboratory of Control of Power Transmission and Conversion, Ministry of Education, Shanghai Jiao Tong University, Shanghai 200240, China
1 shared publication Fang Liu
Shanghai University of Electric Power
1 shared publication- Gangfeng Gao
School of Electric Power Engineering, Shanghai University of Electric Power, Shanghai 200090, China
1 shared publication - Haoyu Li
College of Electrical Engineering, Shanghai University of Electric Power, Shanghai 200090, China
1 shared publication
Latest Publications
- Open Access
Research on Power Grid Accident Analysis and Early Warning Model Based on Meteorological Factors
Natural disasters and extreme meteorological events are primary causes of unplanned outages in modern power systems. Existing early warning methods suffer from insufficient non-linear feature extraction, severe class imbalance, and limited minority-class recall under single-classifier architectures. This paper proposes a seven-class meteorological fault early warning framework that integrates a sparse autoencoder (SAE), a G1–entropy composite weighting scheme, SMOTE oversampling, and a soft-voting BP–XGBoost ensemble. A leakage-free experimental protocol confines SMOTE exclusively to the training partition, eliminating data contamination from evaluation. Validated on 1955 fault records from a regional grid in East China covering 110 kV, 220 kV, and 500 kV voltage levels (2013–2022), the proposed framework achieved 96.42% accuracy and a 97.46% macro F1-score on the held-out test set, outperforming SVM (72.68%), Random Forest (89.31%), LSTM (81.47%), 1D-CNN (85.38%), and LightGBM (92.15%). Ablation experiments confirmed that SMOTE and G1–entropy weighting contributed macro F1 gains of 8.34 and 6.91 percentage points, respectively, while removing the XGBoost branch degraded accuracy by 28.25%. Temporal validation on 2019–2022 records yielded 91.57% accuracy, confirming temporal generalization. Error analysis further revealed that bidirectional misclassification between lightning damage and wind damage, rooted in shared atmospheric instability signatures, constitutes the dominant residual error source, providing theoretical guidance for future threshold optimization strategies.
Open AccessResearch on Power Grid Accident Analysis and Early Warning Model Based on Meteorological Factors
Natural disasters and extreme meteorological events are primary causes of unplanned outages in modern power systems. Existing early warning methods suffer from insufficient non-linear feature extraction, severe class imbalance, and limited minority-class recall under single-classifier architectures. This paper proposes a seven-class meteorological fault early warning framework that integrates a sparse autoencoder (SAE), a G1–entropy composite weighting scheme, SMOTE oversampling, and a soft-voting BP–XGBoost ensemble. A leakage-free experimental protocol confines SMOTE exclusively to the training partition, eliminating data contamination from evaluation. Validated on 1955 fault records from a regional grid in East China covering 110 kV, 220 kV, and 500 kV voltage levels (2013–2022), the proposed framework achieved 96.42% accuracy and a 97.46% macro F1-score on the held-out test set, outperforming SVM (72.68%), Random Forest (89.31%), LSTM (81.47%), 1D-CNN (85.38%), and LightGBM (92.15%). Ablation experiments confirmed that SMOTE and G1–entropy weighting contributed macro F1 gains of 8.34 and 6.91 percentage points, respectively, while removing the XGBoost branch degraded accuracy by 28.25%. Temporal validation on 2019–2022 records yielded 91.57% accuracy, confirming temporal generalization. Error analysis further revealed that bidirectional misclassification between lightning damage and wind damage, rooted in shared atmospheric instability signatures, constitutes the dominant residual error source, providing theoretical guidance for future threshold optimization strategies.
- Open Access
Photovoltaic Sub-Synchronous Oscillation Suppression Method Based on Model-Free Adaptive Control
The large-scale grid integration of photovoltaic systems, accompanied by extensive power electronic equipment, exacerbates the risk of sub-synchronous oscillation (SSO) and poses a serious threat to the safe and stable operation of modern power systems. To address the limitation that traditional additional damping controllers rely on accurate mathematical models of the system, this paper applies model-free adaptive control (MFAC) to suppress sub-synchronous oscillation in photovoltaic systems. The proposed method requires no prior identification of the plant model and achieves adaptive control by online estimation of pseudo-partial derivatives using only system input-output data, with parameters optimized by particle swarm optimization. Simulation results show that the proposed controller can effectively shorten the settling time and suppress oscillations However, for oscillations induced by different mechanisms, it still has the limitation of requiring parameter re-optimization. This approach provides a new model-free technical pathway for sub-synchronous oscillation mitigation in grid-connected photovoltaic systems.
Open AccessPhotovoltaic Sub-Synchronous Oscillation Suppression Method Based on Model-Free Adaptive Control
The large-scale grid integration of photovoltaic systems, accompanied by extensive power electronic equipment, exacerbates the risk of sub-synchronous oscillation (SSO) and poses a serious threat to the safe and stable operation of modern power systems. To address the limitation that traditional additional damping controllers rely on accurate mathematical models of the system, this paper applies model-free adaptive control (MFAC) to suppress sub-synchronous oscillation in photovoltaic systems. The proposed method requires no prior identification of the plant model and achieves adaptive control by online estimation of pseudo-partial derivatives using only system input-output data, with parameters optimized by particle swarm optimization. Simulation results show that the proposed controller can effectively shorten the settling time and suppress oscillations However, for oscillations induced by different mechanisms, it still has the limitation of requiring parameter re-optimization. This approach provides a new model-free technical pathway for sub-synchronous oscillation mitigation in grid-connected photovoltaic systems.
- Open Access
- 22 March 2023
- Published by Wiley
Model Selection and Mechanism Design for Electricity Markets in Hydropower-Rich Regions: Adaptation Study
Most of the first eight pilot regions in China have entered the long-period continuous operation stage, and the second batch of six power spot pilots have started their simulation trial runs; however, the construction of power markets in the hydropower-rich regions of China (i.e., Sichuan and Yunnan) still faces multiple problems, including poor reliability of medium- and long-term power supplies, inefficient hydropower resource utilization and consumption scales, and unstable market prices. In this study, we establish a multi-scale joint clearing model for different market models (considering both long- and short-term operation strategies) and perform simulations of different market models at different time scales, to compare and analyze their optimization results and electricity price fluctuations. The model can stabilize the market price and reasonably reflect the true value of hydropower; it can also promote the consumption of clean energy and ensure the reliability of power supplies in the medium and long term. Finally, suggestions are made regarding the selection of electricity market models, the security of energy supplies, and the design of sustainable development mechanisms for hydropower in hydropower-rich regions, with a view to providing useful references for the development of China’s electricity market.
- 22 March 2023
- Published by Wiley
Open AccessModel Selection and Mechanism Design for Electricity Markets in Hydropower-Rich Regions: Adaptation Study
Most of the first eight pilot regions in China have entered the long-period continuous operation stage, and the second batch of six power spot pilots have started their simulation trial runs; however, the construction of power markets in the hydropower-rich regions of China (i.e., Sichuan and Yunnan) still faces multiple problems, including poor reliability of medium- and long-term power supplies, inefficient hydropower resource utilization and consumption scales, and unstable market prices. In this study, we establish a multi-scale joint clearing model for different market models (considering both long- and short-term operation strategies) and perform simulations of different market models at different time scales, to compare and analyze their optimization results and electricity price fluctuations. The model can stabilize the market price and reasonably reflect the true value of hydropower; it can also promote the consumption of clean energy and ensure the reliability of power supplies in the medium and long term. Finally, suggestions are made regarding the selection of electricity market models, the security of energy supplies, and the design of sustainable development mechanisms for hydropower in hydropower-rich regions, with a view to providing useful references for the development of China’s electricity market.
- Open Access
- 8 June 2021
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 15 (19) , 2804-2818
Research on the assessment of the capacity of urban distribution networks to accept electric vehicles based on the improved TOPSIS method
This study proposes a TOPSIS‐based method for assessing the ability of distribution networks to accept electric vehicles. This method establishes an assessment index system in terms of the rationality, safety, and economy of the distribution network operation, and assesses the capacity of the distribution network in all aspects. Firstly, a fuzzy theory‐based model of users' charging psychology under the influence of time‐of‐use electricity price was constructed, and the spatio‐temporal distribution of EV charging loads in the target area was predicted using travel chain theory and Monte Carlo methods. Secondly, considering the rationality, safety and economy of the distribution network operation, a comprehensive evaluation index system for acceptability has been constructed. Then, a comprehensive weighting method for evaluation indexes based on AHP and entropy weight method is proposed, and the improved TOPSIS is used to evaluate the acceptance capacity of the distribution network when EV charging loads are connected in different ways. Finally, a typical IEEE33 distribution network is used to simulate the time and space distribution of the charging load, and taking the charging load access schemes proposed in this paper to verify the effectiveness of the evaluation method.
- 8 June 2021
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 15 (19) , 2804-2818
Open AccessResearch on the assessment of the capacity of urban distribution networks to accept electric vehicles based on the improved TOPSIS method
This study proposes a TOPSIS‐based method for assessing the ability of distribution networks to accept electric vehicles. This method establishes an assessment index system in terms of the rationality, safety, and economy of the distribution network operation, and assesses the capacity of the distribution network in all aspects. Firstly, a fuzzy theory‐based model of users' charging psychology under the influence of time‐of‐use electricity price was constructed, and the spatio‐temporal distribution of EV charging loads in the target area was predicted using travel chain theory and Monte Carlo methods. Secondly, considering the rationality, safety and economy of the distribution network operation, a comprehensive evaluation index system for acceptability has been constructed. Then, a comprehensive weighting method for evaluation indexes based on AHP and entropy weight method is proposed, and the improved TOPSIS is used to evaluate the acceptance capacity of the distribution network when EV charging loads are connected in different ways. Finally, a typical IEEE33 distribution network is used to simulate the time and space distribution of the charging load, and taking the charging load access schemes proposed in this paper to verify the effectiveness of the evaluation method.
- 29 November 2018
- Published by Springer Nature in Frontiers in Energy
- Vol. 12 (4) , 569-581
Optimal dispatch of multi energy system using power-to-gas technology considering flexible load on user side
- 29 November 2018
- Published by Springer Nature in Frontiers in Energy
- Vol. 12 (4) , 569-581
Optimal dispatch of multi energy system using power-to-gas technology considering flexible load on user side
- Open Access
Integrated Energy System Configuration Optimization for Multi-Zone Heat-Supply Network Interaction
The integrated energy system effectively improves the comprehensive utilization of energy through cascade utilization and coordinated scheduling of various types of energy. Based on the independent integrated energy system, the thermal network interaction between different load characteristic regions is introduced, requiring a minimum thermal grid construction cost, CCHP investment operation cost and carbon emission tax as the comprehensive optimization targets, and making overall optimization to the configuration and operation of the multi-region integrated energy systems. This paper focuses on the planning of equipment capacity of multi-region integrated energy system based on a CCHP system and heat network. Combined with the above comprehensive target and heat network model, a mixed integer linear programming model for a multi-region CCHP system capacity collaborative optimization configuration is established. The integrated energy system, just a numerical model solved with the LINGO software, is presented. Taking a typical urban area in Shanghai as an example, the simulation results show that the integrated energy system with multi-zone heat-suply network interaction compared to the single area CCHP model improved the clean energy utilization of the system, rationally allocates equipment capacity, promotes the local consumption of distributed energy, and provides better overall system benefits.
Open AccessIntegrated Energy System Configuration Optimization for Multi-Zone Heat-Supply Network Interaction
The integrated energy system effectively improves the comprehensive utilization of energy through cascade utilization and coordinated scheduling of various types of energy. Based on the independent integrated energy system, the thermal network interaction between different load characteristic regions is introduced, requiring a minimum thermal grid construction cost, CCHP investment operation cost and carbon emission tax as the comprehensive optimization targets, and making overall optimization to the configuration and operation of the multi-region integrated energy systems. This paper focuses on the planning of equipment capacity of multi-region integrated energy system based on a CCHP system and heat network. Combined with the above comprehensive target and heat network model, a mixed integer linear programming model for a multi-region CCHP system capacity collaborative optimization configuration is established. The integrated energy system, just a numerical model solved with the LINGO software, is presented. Taking a typical urban area in Shanghai as an example, the simulation results show that the integrated energy system with multi-zone heat-suply network interaction compared to the single area CCHP model improved the clean energy utilization of the system, rationally allocates equipment capacity, promotes the local consumption of distributed energy, and provides better overall system benefits.
- Open Access
- 1 October 2014
- Published by Taylor & Francis in Journal of International Council on Electrical Engineering
- Vol. 4 (4) , 341-347
Research on Hybrid Energy Storage System of Super-capacitor and Battery Optimal Allocation
– Hybrid super-capacitor and battery energy storage combine the advantages of power-type energy storage element and energy storage components, to avoid the disadvantages of a single energy storage technology, which is one of the important development direction of the energy storage technology. For energy storage applying in high-power, high-capacity and strong volatility applications, the article analyzes the composition of the total cost of the objective function in the hybrid super-capacitor and battery energy storage system entire life cycle, with regard to two decision variables - the number of each energy storage element batch and the batch of energy storage element in the objective function, proposing calculation method of energy storage component number and batch based respectively on Ragone plots and the equivalent cycle life. The example proves the effectiveness of the proposed method.
- 1 October 2014
- Published by Taylor & Francis in Journal of International Council on Electrical Engineering
- Vol. 4 (4) , 341-347
Open AccessResearch on Hybrid Energy Storage System of Super-capacitor and Battery Optimal Allocation
– Hybrid super-capacitor and battery energy storage combine the advantages of power-type energy storage element and energy storage components, to avoid the disadvantages of a single energy storage technology, which is one of the important development direction of the energy storage technology. For energy storage applying in high-power, high-capacity and strong volatility applications, the article analyzes the composition of the total cost of the objective function in the hybrid super-capacitor and battery energy storage system entire life cycle, with regard to two decision variables - the number of each energy storage element batch and the batch of energy storage element in the objective function, proposing calculation method of energy storage component number and batch based respectively on Ragone plots and the equivalent cycle life. The example proves the effectiveness of the proposed method.