Rajesh Kumar Nema
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Rajesh Kumar Nema has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Savita Nema
Department of Electrical Engineering, MANIT, Bhopal, India
5 shared publications - Dhananjay Kumar
Government Engineering College Siwan
3 shared publications - Shailendra Jain
Maulana Azad National Institute of Technology
2 shared publications - Sunil Kumar Gautam
Maulana Azad National Institute of Technology
2 shared publications - Sushma Gupta
Maulana Azad National Institute of Technology
2 shared publications - Annamalai Kirubakaran
National Institute of Technology Warangal, Warangal, India
1 shared publication
Latest Publications
- 1 May 2024
- Published by Springer Nature in Electrical Engineering
- Vol. 106 (6) , 6911-6926
Advanced order diminution technique for linear time-invariant systems with applications in lag/lead compensators and PID controller design
- 1 May 2024
- Published by Springer Nature in Electrical Engineering
- Vol. 106 (6) , 6911-6926
Advanced order diminution technique for linear time-invariant systems with applications in lag/lead compensators and PID controller design
- 17 October 2023
- Published by Taylor & Francis in IETE Technical Review
- Vol. 41 (4) , 389-409
A Novel Order Abatement Technique for Linear Dynamic Systems and Design of PID Controller
- 17 October 2023
- Published by Taylor & Francis in IETE Technical Review
- Vol. 41 (4) , 389-409
A Novel Order Abatement Technique for Linear Dynamic Systems and Design of PID Controller
- 1 January 2022
- Published by ACTA Press in International Journal of Power and Energy Systems
- Vol. 42 (10)
A NOVEL MULTILEVEL INVERTER TOPOLOGY FOR SYMMETRIC AND ASYMMETRIC SOURCE CONFIGURATION WITH REDUCED DEVICE COUNT
Multilevel inverters (MLIs) are very popular in renewable energy applications due to reduced voltage stress and less total harmonics distortion.
- 1 January 2022
- Published by ACTA Press in International Journal of Power and Energy Systems
- Vol. 42 (10)
A NOVEL MULTILEVEL INVERTER TOPOLOGY FOR SYMMETRIC AND ASYMMETRIC SOURCE CONFIGURATION WITH REDUCED DEVICE COUNT
Multilevel inverters (MLIs) are very popular in renewable energy applications due to reduced voltage stress and less total harmonics distortion.
- 1 January 2022
- Published by ACTA Press in International Journal of Power and Energy Systems
- Vol. 42 (10)
A FAULT-TOLERANT SENSORLESS APPROACH IN FIVE-LEVEL PACKED U CELLS (PUC5) MULTILEVEL INVERTER
In this paper, a modified structure of fault-tolerant (FT) operationhas been designed for the five-level packed U cells (PUC5) multilevelinverter (MLI).
- 1 January 2022
- Published by ACTA Press in International Journal of Power and Energy Systems
- Vol. 42 (10)
A FAULT-TOLERANT SENSORLESS APPROACH IN FIVE-LEVEL PACKED U CELLS (PUC5) MULTILEVEL INVERTER
In this paper, a modified structure of fault-tolerant (FT) operationhas been designed for the five-level packed U cells (PUC5) multilevelinverter (MLI).
- 1 January 2021
- Published by ACTA Press in International Journal of Power and Energy Systems
- Vol. 41 (1) , 17-23
IMPROVING DIELECTRIC DISSIPATION FACTOR OF 420 kV CLASS OIL-SF6 RIP BUSHINGS AT SITE
The resin-impregnated paper (RIP) bushing offers many benefits over the resin-bonded paper (RBP) or oil-impregnated paper (OIP) bushings. RIP bushing that is upgraded with a new generation of epoxy resin-impregnated crepe paper insulation, which is hygroscopic in nature, is highly cured, dried, and processed during the production. The challenging job is to ensure the dried conditions during the long lead time of transportation, storage, erection, testing, and commissioning, though they are preserved and transported in a very protective environment. During the pre-installation check at various commissioning sites, the Tan delta value of RIP bushing must conform to the International Council on Large Electric Systems (CIGRE) standard, else it had to be replaced with a new healthy bushing, causing unnecessary delay in the project schedule and increase in the project cost. As on date, no such on-site Tand improvement procedure is reported/available in the literature that could improve Tand of the RIP bushing with the detrimental value. A new on-site dry-out procedure is evolved and discussed in this paper to improve Tand of the RIP bushing.'
- 1 January 2021
- Published by ACTA Press in International Journal of Power and Energy Systems
- Vol. 41 (1) , 17-23
IMPROVING DIELECTRIC DISSIPATION FACTOR OF 420 kV CLASS OIL-SF6 RIP BUSHINGS AT SITE
The resin-impregnated paper (RIP) bushing offers many benefits over the resin-bonded paper (RBP) or oil-impregnated paper (OIP) bushings. RIP bushing that is upgraded with a new generation of epoxy resin-impregnated crepe paper insulation, which is hygroscopic in nature, is highly cured, dried, and processed during the production. The challenging job is to ensure the dried conditions during the long lead time of transportation, storage, erection, testing, and commissioning, though they are preserved and transported in a very protective environment. During the pre-installation check at various commissioning sites, the Tan delta value of RIP bushing must conform to the International Council on Large Electric Systems (CIGRE) standard, else it had to be replaced with a new healthy bushing, causing unnecessary delay in the project schedule and increase in the project cost. As on date, no such on-site Tand improvement procedure is reported/available in the literature that could improve Tand of the RIP bushing with the detrimental value. A new on-site dry-out procedure is evolved and discussed in this paper to improve Tand of the RIP bushing.'
- 12 June 2020
- Published by Taylor & Francis in IETE Journal of Research
- Vol. 68 (5) , 3670-3682
A Novel Higher Level Symmetrical and Asymmetrical Multilevel Inverter for Solar Energy Environment
In this paper, a higher level symmetrical and asymmetrical multilevel inverter (MLI) with reduced device count is proposed for renewable energy systems. Multilevel inverters are recently gaining importance in renewable energy systems and other DC to AC conversion applications due to reducing voltage stress, low total harmonic distortion (THD) and high-quality output as compared to classical inverters. This paper present a basic cell unit of reduced device count (RDC) MLI with six switching devices is proposed. The topology has advantages of reduced device count over existing topologies for the same number of output levels, thus improving operating efficiency and reliability. Upon cascading two such basic cells with 12 devices synthesizes a 49 level output with an estimated THD of 1.63%. The other advantages accrued due to reduced device count are a reduction in switch driver circuits, less number of required dc voltage sources, less installation space and reduction in cost. The major benefit of the proposed topology is that it can deliver power from an asymmetrical source to load even under sudden variation in environmental conditions. The proposed MLI topology is simulated in MATLAB/Simulink environment and a laboratory prototype is developed and tested in the lab. The control paradigm is developed as the Simulink model, which is interfaced with dSPACE DS-1104 for generating control pulses to drive switches of proposed MLI topology. The experimental results validate the concept and paradigm of the proposed MLI topology.
- 12 June 2020
- Published by Taylor & Francis in IETE Journal of Research
- Vol. 68 (5) , 3670-3682
A Novel Higher Level Symmetrical and Asymmetrical Multilevel Inverter for Solar Energy Environment
In this paper, a higher level symmetrical and asymmetrical multilevel inverter (MLI) with reduced device count is proposed for renewable energy systems. Multilevel inverters are recently gaining importance in renewable energy systems and other DC to AC conversion applications due to reducing voltage stress, low total harmonic distortion (THD) and high-quality output as compared to classical inverters. This paper present a basic cell unit of reduced device count (RDC) MLI with six switching devices is proposed. The topology has advantages of reduced device count over existing topologies for the same number of output levels, thus improving operating efficiency and reliability. Upon cascading two such basic cells with 12 devices synthesizes a 49 level output with an estimated THD of 1.63%. The other advantages accrued due to reduced device count are a reduction in switch driver circuits, less number of required dc voltage sources, less installation space and reduction in cost. The major benefit of the proposed topology is that it can deliver power from an asymmetrical source to load even under sudden variation in environmental conditions. The proposed MLI topology is simulated in MATLAB/Simulink environment and a laboratory prototype is developed and tested in the lab. The control paradigm is developed as the Simulink model, which is interfaced with dSPACE DS-1104 for generating control pulses to drive switches of proposed MLI topology. The experimental results validate the concept and paradigm of the proposed MLI topology.
- 2 January 2014
- Published by Taylor & Francis in IETE Technical Review
- Vol. 31 (1) , 17-33
Adaptive Control Schemes for Improving the Control System Dynamics: A Review
Adaptive control involves modifying the control law used by the controller to cope with the fact that the parameters of the system being controlled change drastically owing to change in environmental conditions or in the system itself. The adaptive control process continuously and automatically measures the dynamic behaviour of plant, compares it with the desired output and uses the difference to vary adjustable system parameters or to generate an actuating signal in such a way that optimal performance can be maintained regardless of system changes. This paper deals with the application of different adaptive schemes in the control system and provides a detailed comparison between the schemes on the basis of their approach to deal with the control problem. A comparative analysis is presented to show the effectiveness of adaptive control techniques during transients in the area of power quality improvement with a shunt active power filter. A classified list of more than 90 publications on this topic is also given for quick reference.
- 2 January 2014
- Published by Taylor & Francis in IETE Technical Review
- Vol. 31 (1) , 17-33
Adaptive Control Schemes for Improving the Control System Dynamics: A Review
Adaptive control involves modifying the control law used by the controller to cope with the fact that the parameters of the system being controlled change drastically owing to change in environmental conditions or in the system itself. The adaptive control process continuously and automatically measures the dynamic behaviour of plant, compares it with the desired output and uses the difference to vary adjustable system parameters or to generate an actuating signal in such a way that optimal performance can be maintained regardless of system changes. This paper deals with the application of different adaptive schemes in the control system and provides a detailed comparison between the schemes on the basis of their approach to deal with the control problem. A comparative analysis is presented to show the effectiveness of adaptive control techniques during transients in the area of power quality improvement with a shunt active power filter. A classified list of more than 90 publications on this topic is also given for quick reference.
- 1 October 2008
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-7
Distributed Generation by Solid Oxide Fuel Cell: A Review
The private power producers are increasing rapidly to meet rising load demand in domestic, commercial and Industrial sector. In this scenario distribution generation system (DGs) plays increasingly important role over fossil fuel generation. A review is therefore carried out in this area of distributed generation system (DGs) with emphasis on Solid Oxide Fuel Cells (SOFCs). The study is performed to review the impact of SOFC's characteristics and associated control strategies on system dynamic behavior in standalone/grid connected applications with the constraint of providing good quality supply to the customers. The main aim of this review is to support researchers in the above field to carry out further research work so as to evolve/design an effective dynamic model/power conditioning unit with overall reduced system cost and increased life span & efficiency of generating system.
- 1 October 2008
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-7
Distributed Generation by Solid Oxide Fuel Cell: A Review
The private power producers are increasing rapidly to meet rising load demand in domestic, commercial and Industrial sector. In this scenario distribution generation system (DGs) plays increasingly important role over fossil fuel generation. A review is therefore carried out in this area of distributed generation system (DGs) with emphasis on Solid Oxide Fuel Cells (SOFCs). The study is performed to review the impact of SOFC's characteristics and associated control strategies on system dynamic behavior in standalone/grid connected applications with the constraint of providing good quality supply to the customers. The main aim of this review is to support researchers in the above field to carry out further research work so as to evolve/design an effective dynamic model/power conditioning unit with overall reduced system cost and increased life span & efficiency of generating system.
- 1 October 2008
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Superiority of PSO Relay Coordination Algorithm over Non-Linear Programming: A Comparison, Review and Verification
Over Current Relays (OCRs) and Directional Over Current Relays (DOCRs) are widely used for the radial protection and ring sub transmission protection systems and for distribution systems. All previous work formulates the DOCR coordination problem either as a Linear Programming (LP) problem or as a Non Linear Programming (NLP) problem or as a Mixed Integer Non Linear Programming (MINLP) Problem or as a Mixed Integer Programming (MIP) problem using optimization techniques. In this paper, a Modified Particle Swarm Optimization (MPSO) technique is discussed, reviewed and verified for the optimal settings of DOCRs in power systems as a NLP problem. The paper also compares MPSO algorithm with General Algebraic Modeling System (GAMS). The calculation of the Time Dial Setting (TDS) and the pickup current (Ip) setting of the relays is the core of the coordination study. Recently PSO is considered as realistic and powerful solution schemes to obtain the global or quasi global optimum in optimization.
- 1 October 2008
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Superiority of PSO Relay Coordination Algorithm over Non-Linear Programming: A Comparison, Review and Verification
Over Current Relays (OCRs) and Directional Over Current Relays (DOCRs) are widely used for the radial protection and ring sub transmission protection systems and for distribution systems. All previous work formulates the DOCR coordination problem either as a Linear Programming (LP) problem or as a Non Linear Programming (NLP) problem or as a Mixed Integer Non Linear Programming (MINLP) Problem or as a Mixed Integer Programming (MIP) problem using optimization techniques. In this paper, a Modified Particle Swarm Optimization (MPSO) technique is discussed, reviewed and verified for the optimal settings of DOCRs in power systems as a NLP problem. The paper also compares MPSO algorithm with General Algebraic Modeling System (GAMS). The calculation of the Time Dial Setting (TDS) and the pickup current (Ip) setting of the relays is the core of the coordination study. Recently PSO is considered as realistic and powerful solution schemes to obtain the global or quasi global optimum in optimization.