James Talman
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Interests
James Talman has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Aaron Fleischman
Department of Biomedical Engineering, Lerner Research Institute, The Cleveland Clinic, United States of America
1 shared publication - Chaitanya Chandrana
Cleveland Clinic, Department of Biomedical Engineering, Cleveland, OH. Cleveland State University, Department of Chemical and Biomedical Engineering, Cleveland, OH
1 shared publication - Shuvo Roy
University of California, San Francisco, USA
1 shared publication - Tao Pan
Department of Biomedical Engineering, Cleveland Clinic, Cleveland, OH, USA
1 shared publication
Latest Publications
- Open Access
Design and Analysis of MEMS Based PVDF Ultrasonic Transducers for Vascular Imaging
Polyvinilidene fluoride (PVDF) single-element transducers for high-frequency (> 30 MHz) ultrasound imaging applications have been developed using MEMS (Micro-electro-Mechanical Systems) compatible techniques. Performance of these transducers has been investigated by analyzing the sources and effects of on-chip parasitic capacitances on the insertion-loss of the transducers. Modeling and experimental studies showed that on-chip parasitic capacitances degraded the performance of the transducers and an improved method of fabrication was suggested and new devices were built. New devices developed with minimal parasitic effects were shown to improve the performance significantly. A 1-mm aperture PVDF device developed with minimal parasitic effects has resulted in a reduction of insertion loss of 21 dB compared with devices fabricated using a previous method.
Open AccessDesign and Analysis of MEMS Based PVDF Ultrasonic Transducers for Vascular Imaging
Polyvinilidene fluoride (PVDF) single-element transducers for high-frequency (> 30 MHz) ultrasound imaging applications have been developed using MEMS (Micro-electro-Mechanical Systems) compatible techniques. Performance of these transducers has been investigated by analyzing the sources and effects of on-chip parasitic capacitances on the insertion-loss of the transducers. Modeling and experimental studies showed that on-chip parasitic capacitances degraded the performance of the transducers and an improved method of fabrication was suggested and new devices were built. New devices developed with minimal parasitic effects were shown to improve the performance significantly. A 1-mm aperture PVDF device developed with minimal parasitic effects has resulted in a reduction of insertion loss of 21 dB compared with devices fabricated using a previous method.