Thushara Perera
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Thushara Perera has a total of 50 co-authors. Here are the top co-authors by number of shared publications:
- Adam P. Vogel
The University of Melbourne
3 shared publications Hugh J. McDermott
Bionics Institute, East Melbourne, Victoria, Australia; Department of Medical Bionics, University of Melbourne, East Melbourne, Victoria, Australia
2 shared publicationsHugh McDermott
2 shared publicationsJames Fallon
2 shared publicationsMary Jones
Bionics Institute, East Melbourne, Victoria, Australia; Department of Neurology, St. Vincent's Hospital, Fitzroy, Victoria, Australia
2 shared publicationsNicholas Sinclair
2 shared publications
Latest Publications
- Open Access
Evaluation of cerebellar function scores in relation to cerebellar axonal loss in multiple sclerosis
Background: Cerebellar damage is common in people with multiple sclerosis (pwMS) and is associated with worse progression and relapse recovery. Studies into the importance of the cerebellum in pwMS are hampered by limited understanding of cerebellar damage and its relation to cerebellar function in pwMS. Objective: Examine axonal loss, as a primary driver of progressive neurological decline, in the cerebellum using advanced diffusion MRI and compare axonal loss with cerebellar dysfunction in pwMS Methods: We recruited 55 pwMS and 14 healthy controls. Clinical assessments included scale for the assessment and rating of ataxia (SARA), and Bain tremor ratings. Subjects underwent FLAIR, T1-weighted and diffusion MRI. Cerebellar grey and white matter and lesion volume were calculated. Cerebellar axonal loss was examined with fibre-specific markers. Fibre density and cross-section (FDC) accounts for microscopic and macroscopic changes in a fibre bundle. Results: Loss of cerebellar FDC was associated with increased SARA (r=-0.42, p<0.01) and tremor severity (rho=-0.35, p=0.01). Cerebellar lesion volume correlated with SARA (r=0.49, p<0.01) and tremor severity (rho=0.41, p=0.01). Conclusion: Fibre-specific measures of cerebellar pathology could provide a functionally relevant marker of cerebellar damage in MS. Future trials using fibre-specific markers are needed to further characterize cerebellar pathology in pwMS and understand its significance in disease progression.
Open AccessEvaluation of cerebellar function scores in relation to cerebellar axonal loss in multiple sclerosis
Background: Cerebellar damage is common in people with multiple sclerosis (pwMS) and is associated with worse progression and relapse recovery. Studies into the importance of the cerebellum in pwMS are hampered by limited understanding of cerebellar damage and its relation to cerebellar function in pwMS. Objective: Examine axonal loss, as a primary driver of progressive neurological decline, in the cerebellum using advanced diffusion MRI and compare axonal loss with cerebellar dysfunction in pwMS Methods: We recruited 55 pwMS and 14 healthy controls. Clinical assessments included scale for the assessment and rating of ataxia (SARA), and Bain tremor ratings. Subjects underwent FLAIR, T1-weighted and diffusion MRI. Cerebellar grey and white matter and lesion volume were calculated. Cerebellar axonal loss was examined with fibre-specific markers. Fibre density and cross-section (FDC) accounts for microscopic and macroscopic changes in a fibre bundle. Results: Loss of cerebellar FDC was associated with increased SARA (r=-0.42, p<0.01) and tremor severity (rho=-0.35, p=0.01). Cerebellar lesion volume correlated with SARA (r=0.49, p<0.01) and tremor severity (rho=0.41, p=0.01). Conclusion: Fibre-specific measures of cerebellar pathology could provide a functionally relevant marker of cerebellar damage in MS. Future trials using fibre-specific markers are needed to further characterize cerebellar pathology in pwMS and understand its significance in disease progression.
- 6 April 2019
- Published by MyJove Corporation in Journal of Visualized Experiments
- No. 146,p. e59309
An Instrumented Pull Test to Characterize Postural Responses
Impairment of postural reflexes, termed postural instability, is a common and disabling deficit in Parkinson's disease. To assess postural reflexes, clinicians typically employ the pull test to grade corrective responses to a backward perturbation at the shoulders. However, the pull test is prone to issues with reliability and scaling (score/4). Here, we present an instrumented version of the pull test to more precisely quantify postural responses. Akin to the clinical test, pulls are manually administered except pull force is also recorded. Displacements of the trunk and feet are captured by a semi-portable motion tracking system. Raw data represent distance traveled (in millimeter units), making subsequent interpretation and analysis intuitive. The instrumented pull test also detects variabilities influencing pull test administration, such as pull force, thereby identifying and quantifying potential confounds that can be accounted for by statistical techniques. The instrumented pull test could have application in studies seeking to capture early abnormalities in postural responses, track postural instability over time, and detect responses to therapy.
- 6 April 2019
- Published by MyJove Corporation in Journal of Visualized Experiments
- No. 146,p. e59309
An Instrumented Pull Test to Characterize Postural Responses
Impairment of postural reflexes, termed postural instability, is a common and disabling deficit in Parkinson's disease. To assess postural reflexes, clinicians typically employ the pull test to grade corrective responses to a backward perturbation at the shoulders. However, the pull test is prone to issues with reliability and scaling (score/4). Here, we present an instrumented version of the pull test to more precisely quantify postural responses. Akin to the clinical test, pulls are manually administered except pull force is also recorded. Displacements of the trunk and feet are captured by a semi-portable motion tracking system. Raw data represent distance traveled (in millimeter units), making subsequent interpretation and analysis intuitive. The instrumented pull test also detects variabilities influencing pull test administration, such as pull force, thereby identifying and quantifying potential confounds that can be accounted for by statistical techniques. The instrumented pull test could have application in studies seeking to capture early abnormalities in postural responses, track postural instability over time, and detect responses to therapy.
- 1 April 2019
- Published by Elsevier in Journal of Neuroscience Methods
- Vol. 317, 113-120
A palm-worn device to quantify rigidity in Parkinson’s disease
- 1 April 2019
- Published by Elsevier in Journal of Neuroscience Methods
- Vol. 317, 113-120
A palm-worn device to quantify rigidity in Parkinson’s disease
- 1 January 2019
- Published by Elsevier in Journal of Neuroscience Methods
- Vol. 311, 377-384
Validation of a precision tremor measurement system for multiple sclerosis
- 1 January 2019
- Published by Elsevier in Journal of Neuroscience Methods
- Vol. 311, 377-384
Validation of a precision tremor measurement system for multiple sclerosis
- 11 August 2016
- Published by IOP Publishing in Physiological Measurement
- Vol. 37 (9) , 1516-1527
Clinical validation of a precision electromagnetic tremor measurement system in participants receiving deep brain stimulation for essential tremor
Tremor is characterized commonly through subjective clinical rating scales. Accelerometer-based techniques for objective tremor measurement have been developed in the past, yet these measures are usually presented as an unintuitive dimensionless index without measurement units. Here we have developed a tool (TREMBAL) to provide quantifiable and objective measures of tremor severity using electromagnetic motion tracking. We aimed to compare TREMBAL's objective measures with clinical tremor ratings and determine the test–retest reliability of our technique. Eight participants with ET receiving deep brain stimulation (DBS) therapy were consented. Tremor was simultaneously recorded using TREMBAL and video during DBS adjustment. After each adjustment, participants performed a hands-outstretched task (for postural tremor) and a finger–nose task (for kinetic tremor). Video recordings were de-identified, randomized, and shown to a panel of movement disorder specialists to obtain their ratings. Regression analysis and Pearson's correlations were used to determine agreement between datasets. Subsets of the trial were repeated to assess test–retest reliability. Tremor amplitude and velocity measures were in close agreement with mean clinical ratings (r > 0.90) for both postural and kinetic tremors. Test–retest reliability for both translational and rotational components of tremor showed intra-class correlations >0.80. TREMBAL assessments showed that tremor gradually improved with increasing DBS therapy—this was also supported by clinical observation. TREMBAL measurements are a sensitive, objective and reliable assessment of tremor severity. This tool may have application in clinical trials and in aiding automated optimization of deep brain stimulation.
- 11 August 2016
- Published by IOP Publishing in Physiological Measurement
- Vol. 37 (9) , 1516-1527
Clinical validation of a precision electromagnetic tremor measurement system in participants receiving deep brain stimulation for essential tremor
Tremor is characterized commonly through subjective clinical rating scales. Accelerometer-based techniques for objective tremor measurement have been developed in the past, yet these measures are usually presented as an unintuitive dimensionless index without measurement units. Here we have developed a tool (TREMBAL) to provide quantifiable and objective measures of tremor severity using electromagnetic motion tracking. We aimed to compare TREMBAL's objective measures with clinical tremor ratings and determine the test–retest reliability of our technique. Eight participants with ET receiving deep brain stimulation (DBS) therapy were consented. Tremor was simultaneously recorded using TREMBAL and video during DBS adjustment. After each adjustment, participants performed a hands-outstretched task (for postural tremor) and a finger–nose task (for kinetic tremor). Video recordings were de-identified, randomized, and shown to a panel of movement disorder specialists to obtain their ratings. Regression analysis and Pearson's correlations were used to determine agreement between datasets. Subsets of the trial were repeated to assess test–retest reliability. Tremor amplitude and velocity measures were in close agreement with mean clinical ratings (r > 0.90) for both postural and kinetic tremors. Test–retest reliability for both translational and rotational components of tremor showed intra-class correlations >0.80. TREMBAL assessments showed that tremor gradually improved with increasing DBS therapy—this was also supported by clinical observation. TREMBAL measurements are a sensitive, objective and reliable assessment of tremor severity. This tool may have application in clinical trials and in aiding automated optimization of deep brain stimulation.
- 29 May 2015
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 54 (2-3) , 333-339
A simple and inexpensive test-rig for evaluating the performance of motion sensors used in movement disorders research
Since the advent of electromyogram recording, precise measures of tremor and gait have been used to study movement disorders such as Parkinson’s disease. Now, a wide range of accelerometers and other motion-tracking technologies exist to better inform researchers and clinicians, yet such systems are rarely tested for accuracy or suitability before use. Our inexpensive test-rig can produce sinusoidal displacements using a simple cantilever system driven by a subwoofer. Controlled sinusoids were generated using computer software, and the displacement amplitudes of the test-rig were verified with fiducial marker tracking. To illustrate the use of the test-rig, we evaluated an accelerometer and an electromagnetic motion tracker. Accelerometry recordings were accurate to within ±0.09 g of actual peak-to-peak amplitude with a frequency response close to unity gain between 1 and 20 Hz. The electromagnetic sensor underestimated peak displacement by 2.68 mm, which was largely due to a diminishing gain with increasing frequency. Both sensors had low distortion. Overall sensitivity was limited by noise for the accelerometer and quantisation resolution for the electromagnetic sensor. Our simple and low-cost test-rig can be used to bench-test sensors used in movement disorders research. It was able to produce reliable sinusoidal displacements and worked across the 1- to 20-Hz frequency range.
- 29 May 2015
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 54 (2-3) , 333-339
A simple and inexpensive test-rig for evaluating the performance of motion sensors used in movement disorders research
Since the advent of electromyogram recording, precise measures of tremor and gait have been used to study movement disorders such as Parkinson’s disease. Now, a wide range of accelerometers and other motion-tracking technologies exist to better inform researchers and clinicians, yet such systems are rarely tested for accuracy or suitability before use. Our inexpensive test-rig can produce sinusoidal displacements using a simple cantilever system driven by a subwoofer. Controlled sinusoids were generated using computer software, and the displacement amplitudes of the test-rig were verified with fiducial marker tracking. To illustrate the use of the test-rig, we evaluated an accelerometer and an electromagnetic motion tracker. Accelerometry recordings were accurate to within ±0.09 g of actual peak-to-peak amplitude with a frequency response close to unity gain between 1 and 20 Hz. The electromagnetic sensor underestimated peak displacement by 2.68 mm, which was largely due to a diminishing gain with increasing frequency. Both sensors had low distortion. Overall sensitivity was limited by noise for the accelerometer and quantisation resolution for the electromagnetic sensor. Our simple and low-cost test-rig can be used to bench-test sensors used in movement disorders research. It was able to produce reliable sinusoidal displacements and worked across the 1- to 20-Hz frequency range.
- 1 March 2015
- Published by Elsevier in Brain Stimulation
- Vol. 8 (2) , 365-366
A personalised, closed-loop DBS system based on a cranial neurostimulator for treating Parkinson’s disease and other disorders
- 1 March 2015
- Published by Elsevier in Brain Stimulation
- Vol. 8 (2) , 365-366
A personalised, closed-loop DBS system based on a cranial neurostimulator for treating Parkinson’s disease and other disorders
- 1 March 2015
- Published by Elsevier in Brain Stimulation
- Vol. 8 (2) , 361
Clinical efficacy of symmetric constant-current biphasic pulses for deep brain stimulation
- 1 March 2015
- Published by Elsevier in Brain Stimulation
- Vol. 8 (2) , 361
Clinical efficacy of symmetric constant-current biphasic pulses for deep brain stimulation
- 1 March 2015
- Published by Elsevier in Brain Stimulation
- Vol. 8 (2) , 358-359
Development of precise tremor assessment software to aid deep brain stimulation parameter optimization
- 1 March 2015
- Published by Elsevier in Brain Stimulation
- Vol. 8 (2) , 358-359
Development of precise tremor assessment software to aid deep brain stimulation parameter optimization
- 30 December 2014
- Published by Wiley in Pediatric Anesthesia
- Vol. 25 (3) , 317-326
A Pilot study to determine whether visually evoked hemodynamic responses are preserved in children during inhalational anesthesia
Summary: Background: Anesthetic depth is an important parameter to monitor during surgery, yet remains difficult to quantify, particularly in young children where developmental changes influence the electroencephalogram. A more fundamental physiological response to stimulation is the increase in cerebral blood flow secondary to increased metabolic demand, referred to as flow–metabolism coupling (FMC) and measurable using near‐infrared spectroscopy (NIRS). Little is known about the effect of anesthesia on FMC; therefore, we studied visually evoked hemodynamic responses (VEHRs) using NIRS in children undergoing general anesthesia for minor surgical procedures.Method: We recruited 23 children (aged 2–5 years), undergoing surgery requiring general anesthesia. VEHRs were measured for 30 min using NIRS, including 5 min of baseline recording after anesthetic induction. Parameters recorded using NIRS included the concentrations of oxygenated (oxy), deoxygenated (deoxy), and total hemoglobin (Hb), which were separated into epochs for evoked response analysis after filtration of motion artifact and baseline drift. Goodness‐of‐fit statistics and classification rules were used to determine the existence of evoked responses, and a modified Gaussian equation was used to model each evoked response.Results: Near‐infrared spectroscopy data were recorded in 20/23 children, of whom nine showed a VEHR. No responses were seen in the baseline control data. When examining the relationship between VEHR and anesthetic agents, we noted that for 8/10 patients in whom preoperative or intraoperative fentanyl were administered and VEHRs were absent.Conclusion: We have shown that VEHRs can be detected using NIRS in some anesthetized children. Administration of fentanyl was associated with an absence of VEHRs. The mechanism underlying this association is unclear.
- 30 December 2014
- Published by Wiley in Pediatric Anesthesia
- Vol. 25 (3) , 317-326
A Pilot study to determine whether visually evoked hemodynamic responses are preserved in children during inhalational anesthesia
Summary: Background: Anesthetic depth is an important parameter to monitor during surgery, yet remains difficult to quantify, particularly in young children where developmental changes influence the electroencephalogram. A more fundamental physiological response to stimulation is the increase in cerebral blood flow secondary to increased metabolic demand, referred to as flow–metabolism coupling (FMC) and measurable using near‐infrared spectroscopy (NIRS). Little is known about the effect of anesthesia on FMC; therefore, we studied visually evoked hemodynamic responses (VEHRs) using NIRS in children undergoing general anesthesia for minor surgical procedures.Method: We recruited 23 children (aged 2–5 years), undergoing surgery requiring general anesthesia. VEHRs were measured for 30 min using NIRS, including 5 min of baseline recording after anesthetic induction. Parameters recorded using NIRS included the concentrations of oxygenated (oxy), deoxygenated (deoxy), and total hemoglobin (Hb), which were separated into epochs for evoked response analysis after filtration of motion artifact and baseline drift. Goodness‐of‐fit statistics and classification rules were used to determine the existence of evoked responses, and a modified Gaussian equation was used to model each evoked response.Results: Near‐infrared spectroscopy data were recorded in 20/23 children, of whom nine showed a VEHR. No responses were seen in the baseline control data. When examining the relationship between VEHR and anesthetic agents, we noted that for 8/10 patients in whom preoperative or intraoperative fentanyl were administered and VEHRs were absent.Conclusion: We have shown that VEHRs can be detected using NIRS in some anesthetized children. Administration of fentanyl was associated with an absence of VEHRs. The mechanism underlying this association is unclear.