Lauryn E. DeGreeff
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Lauryn E. DeGreeff has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
Christopher J. Katilie
Nova Research Inc, Alexandria, USA
5 shared publications- Alison G. Simon
Former National Research Council post-doctoral fellow at U.S. Naval Research Laboratory, 4555 Overlook Ave. SW, Washington DC, 20375, USA
3 shared publications Kimberly Peranich
Naval Surface Warfare Center Indian Head EOD Technology Division, 3767 Strauss Ave., Indian Head MD, 20640, USA
3 shared publicationsMichael Malito
Nova Research Inc, USA
3 shared publications- Howard K. Holness
Global Forensic and Justice Center, Department of Chemistry and Biochemistry, Florida International University, Miami, FL 33199, USA
2 shared publications Kelvin Frank
Florida International University, International Forensic Research Institute, Chemistry Department, 11200 SW 8(th)St., Miami, FL, 33199, USA
2 shared publications
Latest Publications
- 28 January 2021
- Published by MyJove Corporation in Journal of Visualized Experiments
- No. 167,p. e60846
Controlled Odor Mimic Permeation Systems for Olfactory Training and Field Testing
The Controlled Odor Mimic Permeation System (COMPS) was developed to provide a convenient field testing method of odor delivery at controlled and reproducible rates. COMPS are composed of an odorant of interest on an absorbent material sealed inside of a permeable polymer bag. The permeable layer allows for a constant release of the odorant over a given amount of time. The permeable bag is further stored in a secondary, impermeable bag. The double-containment procedure allows for equilibration of the odorant from the permeable bag but within the impermeable outer layer, resulting in an instant and reproducible source of odorant vapor upon removal from the outer packaging. COMPS are used in both olfactory testing for experimental scenarios and for olfactory detection training, such as with detection canines. COMPS can be used to contain a wide range of odorants (e.g., narcotics powders) and provide a controlled release of the associated odorants. Odor availability from COMPS is expressed in terms of permeation rate (i.e., the rate of the odorant vapor released from a COMPS per unit time) and is typically measured by gravimetric means. The permeation rate for a given mass or volume of odorant can be adjusted as needed by varying the bag thickness, surface area, and/or polymer type. The available odor concentration from a COMPS can also be measured by headspace analysis techniques such as solid phase microextraction with gas chromatography/mass spectrometry (SPME-GC/MS).
- 28 January 2021
- Published by MyJove Corporation in Journal of Visualized Experiments
- No. 167,p. e60846
Controlled Odor Mimic Permeation Systems for Olfactory Training and Field Testing
The Controlled Odor Mimic Permeation System (COMPS) was developed to provide a convenient field testing method of odor delivery at controlled and reproducible rates. COMPS are composed of an odorant of interest on an absorbent material sealed inside of a permeable polymer bag. The permeable layer allows for a constant release of the odorant over a given amount of time. The permeable bag is further stored in a secondary, impermeable bag. The double-containment procedure allows for equilibration of the odorant from the permeable bag but within the impermeable outer layer, resulting in an instant and reproducible source of odorant vapor upon removal from the outer packaging. COMPS are used in both olfactory testing for experimental scenarios and for olfactory detection training, such as with detection canines. COMPS can be used to contain a wide range of odorants (e.g., narcotics powders) and provide a controlled release of the associated odorants. Odor availability from COMPS is expressed in terms of permeation rate (i.e., the rate of the odorant vapor released from a COMPS per unit time) and is typically measured by gravimetric means. The permeation rate for a given mass or volume of odorant can be adjusted as needed by varying the bag thickness, surface area, and/or polymer type. The available odor concentration from a COMPS can also be measured by headspace analysis techniques such as solid phase microextraction with gas chromatography/mass spectrometry (SPME-GC/MS).
- 20 November 2020
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 413 (3) , 955-966
Quantitative vapor delivery for improved canine threshold testing
The canine olfactory system is a highly efficient and intricate tool often exploited by humans for detection for its many attributes, including impressive sensitivity to trace analyte vapors. Canine detectors are often touted as having lower limits of detection, or olfactory detection threshold (ODT), than other field-relevant detection technologies; however, previous attempts to quantify canine ODTs have resulted in reported estimates spanning multiple orders of magnitude, even for the same analyte. A major contributor to these discrepancies is the vapor delivery method used for testing, where losses due to adsorption and dilution are often unaccounted for, and the presence of unattended compounds in the vapor stream due to carryover may go unnoticed. In this research, a trace vapor generator (TV-Gen) was used to deliver quantitatively accurate amounts of vapor reproducibly over time for canine testing. Analyte losses due to adsorption to surfaces in the flow path, dilution in the sniff port at the outlet, and analyte carryover were considered. Computational fluid dynamic (CFD) modeling was used to visualize analyte vapor spread throughout the port. CFD simulations revealed the need for a diffuser to encourage the diffusion of the analyte throughout the port. As a result, the modified vapor generator provides analyte air as a diffuse flow that is evenly distributed through the custom sampling orifice, as opposed to a narrow stream of air at the chosen concentration which exits directly into the environment. Laboratory validations were carried out for three analytes, amyl acetate, 2,4-dinitrotoluene (DNT), and methyl benzoate. A linear response across more than two orders of magnitude vapor concentration range was achieved for all analytes. These efforts will be applied in further research utilizing this TV-Gen vapor delivery system for canine ODT testing, eliminating many quantitative changes seen previously. Graphical abstract
- 20 November 2020
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 413 (3) , 955-966
Quantitative vapor delivery for improved canine threshold testing
The canine olfactory system is a highly efficient and intricate tool often exploited by humans for detection for its many attributes, including impressive sensitivity to trace analyte vapors. Canine detectors are often touted as having lower limits of detection, or olfactory detection threshold (ODT), than other field-relevant detection technologies; however, previous attempts to quantify canine ODTs have resulted in reported estimates spanning multiple orders of magnitude, even for the same analyte. A major contributor to these discrepancies is the vapor delivery method used for testing, where losses due to adsorption and dilution are often unaccounted for, and the presence of unattended compounds in the vapor stream due to carryover may go unnoticed. In this research, a trace vapor generator (TV-Gen) was used to deliver quantitatively accurate amounts of vapor reproducibly over time for canine testing. Analyte losses due to adsorption to surfaces in the flow path, dilution in the sniff port at the outlet, and analyte carryover were considered. Computational fluid dynamic (CFD) modeling was used to visualize analyte vapor spread throughout the port. CFD simulations revealed the need for a diffuser to encourage the diffusion of the analyte throughout the port. As a result, the modified vapor generator provides analyte air as a diffuse flow that is evenly distributed through the custom sampling orifice, as opposed to a narrow stream of air at the chosen concentration which exits directly into the environment. Laboratory validations were carried out for three analytes, amyl acetate, 2,4-dinitrotoluene (DNT), and methyl benzoate. A linear response across more than two orders of magnitude vapor concentration range was achieved for all analytes. These efforts will be applied in further research utilizing this TV-Gen vapor delivery system for canine ODT testing, eliminating many quantitative changes seen previously. Graphical abstract
- 1 August 2020
- Published by Elsevier in Behavioural Processes
- Vol. 177, 104148
Generalization and Discrimination of Molecularly Similar Odorants in Detection Canines and the Influence of Training
- 1 August 2020
- Published by Elsevier in Behavioural Processes
- Vol. 177, 104148
Generalization and Discrimination of Molecularly Similar Odorants in Detection Canines and the Influence of Training
- Open Access
- 21 May 2019
- Published by Oxford University Press (OUP) in Chemical Senses
- Vol. 44 (6) , 399-408
A Method for Controlled Odor Delivery in Olfactory Field-Testing
A widely recognized limitation in mammalian olfactory research is the lack of current methods for measuring odor availability (i.e., the quantifiable amount of odor presented and thus available for olfaction) of training or testing materials during behavioral or operational testing. This research utilized an existing technology known as Controlled Odor Mimic Permeation Systems (COMPS) to produce a reproducible, field-appropriate odor delivery method that can be analytically validated and quantified, akin to laboratory-based research methods, such as permeation devices that deliver a stable concentration of a specific chemical vapor for instrumental testing purposes. COMPS were created for 12 compounds across a range of carbon chain lengths and functional groups in such a way to produce similar permeation rates for all compounds. Using detection canines as a model, field-testing was performed to assess the efficacy of the method. Additionally headspace concentrations over time were measured as confirmation of odor availability using either externally sampled internal standard-solid phase microextraction-gas chromatography-mass spectrometry (ESIS-SPME-GC-MS) or collection onto a programmable temperature vaporizing (PTV) GC inlet with MS detection. Finally, lifetime usage was considered. An efficient method for producing and measuring reliable odor availabilities across various chemical functional groups was developed, addressing a noted gap in existing literature that will advance canine and other nonhuman mammal research testing.
- 21 May 2019
- Published by Oxford University Press (OUP) in Chemical Senses
- Vol. 44 (6) , 399-408
Open AccessA Method for Controlled Odor Delivery in Olfactory Field-Testing
A widely recognized limitation in mammalian olfactory research is the lack of current methods for measuring odor availability (i.e., the quantifiable amount of odor presented and thus available for olfaction) of training or testing materials during behavioral or operational testing. This research utilized an existing technology known as Controlled Odor Mimic Permeation Systems (COMPS) to produce a reproducible, field-appropriate odor delivery method that can be analytically validated and quantified, akin to laboratory-based research methods, such as permeation devices that deliver a stable concentration of a specific chemical vapor for instrumental testing purposes. COMPS were created for 12 compounds across a range of carbon chain lengths and functional groups in such a way to produce similar permeation rates for all compounds. Using detection canines as a model, field-testing was performed to assess the efficacy of the method. Additionally headspace concentrations over time were measured as confirmation of odor availability using either externally sampled internal standard-solid phase microextraction-gas chromatography-mass spectrometry (ESIS-SPME-GC-MS) or collection onto a programmable temperature vaporizing (PTV) GC inlet with MS detection. Finally, lifetime usage was considered. An efficient method for producing and measuring reliable odor availabilities across various chemical functional groups was developed, addressing a noted gap in existing literature that will advance canine and other nonhuman mammal research testing.
- 1 December 2018
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1040, 41-48
Mixed Vapor Generation Device for delivery of homemade explosives vapor plumes
- 1 December 2018
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1040, 41-48
Mixed Vapor Generation Device for delivery of homemade explosives vapor plumes
- 9 June 2017
- Published by Wiley in Journal of Forensic Sciences
- Vol. 62 (6) , 1613-1616
Feasibility of Canine Detection of Mass Storage Devices: A Study of Volatile Organic Compounds Emanating from Electronic Devices Using Solid Phase Microextraction
Detection of canines are well‐known to be valuable in the location of contraband, such as explosives or narcotics. More recently, canines have been trained and utilized in the detection of concealed mass storage devices that might contain evidence of illegal activity such as child pornography. To lay the analytical foundation for this detection work, research was carried out to determine the volatile organic compounds associated with mass storage devices (MSD) that could be used by trained canines for detection. Headspace analysis of a variety of electronic devices was performed using solid phase microextraction (SPME) with gas chromatography/mass spectrometry (GC/MS). Analyses found several volatile compounds common to SIM and SD cards, as well as USB drives, including 2‐propenenitrile, styrene, isophorone, hydroxycyclohexyl phenyl ketone, and 2‐furanmethanol, tetrahydro. Results indicated that mass storage devices do have a characteristic odor profile making detection with minimal false alerts feasible for trained canines.
- 9 June 2017
- Published by Wiley in Journal of Forensic Sciences
- Vol. 62 (6) , 1613-1616
Feasibility of Canine Detection of Mass Storage Devices: A Study of Volatile Organic Compounds Emanating from Electronic Devices Using Solid Phase Microextraction
Detection of canines are well‐known to be valuable in the location of contraband, such as explosives or narcotics. More recently, canines have been trained and utilized in the detection of concealed mass storage devices that might contain evidence of illegal activity such as child pornography. To lay the analytical foundation for this detection work, research was carried out to determine the volatile organic compounds associated with mass storage devices (MSD) that could be used by trained canines for detection. Headspace analysis of a variety of electronic devices was performed using solid phase microextraction (SPME) with gas chromatography/mass spectrometry (GC/MS). Analyses found several volatile compounds common to SIM and SD cards, as well as USB drives, including 2‐propenenitrile, styrene, isophorone, hydroxycyclohexyl phenyl ketone, and 2‐furanmethanol, tetrahydro. Results indicated that mass storage devices do have a characteristic odor profile making detection with minimal false alerts feasible for trained canines.
- 1 June 2017
- Published by Elsevier in Forensic Chemistry
- Vol. 4, 19-31
Passive delivery of mixed explosives vapor from separated components
- 1 June 2017
- Published by Elsevier in Forensic Chemistry
- Vol. 4, 19-31
Passive delivery of mixed explosives vapor from separated components
- 1 June 2016
- Published by Elsevier in Journal of Chromatography A
- Vol. 1451, 83-90
Factors affecting the intramolecular decomposition of hexamethylene triperoxide diamine and implications for detection
- 1 June 2016
- Published by Elsevier in Journal of Chromatography A
- Vol. 1451, 83-90
Factors affecting the intramolecular decomposition of hexamethylene triperoxide diamine and implications for detection