QHQiang He

Qiang He

*This is an algorithmically generated author record based on publicly available information.

Qiang He has a total of 34 co-authors. Here are the top co-authors by number of shared publications:

  • Guilong Peng

    State Key Laboratory of Resource Insects, College of Sericulture, Textile and Biomass Sciences, Southwest University, Chongqing 400715, China

    11 shared publications
  • Daniel Mmereki

    Radiation Oncology, University of the Witwatersrand Johannesburg Faculty of Health Sciences, Johannesburg, South Africa

    7 shared publications
  • Ying Lu

    Department of Mathematics and Physics, Armed Police College, Chengdu, 610213, China

    7 shared publications
  • Guangming Zhou

    Key Laboratory on Luminescence and Real-Time Analysis (Southwest University), Ministry of Education, School of Chemistry and Chemical Engineering, Southwest University, Chongqing, China

    5 shared publications
  • Xiaohui Tang

    Key Laboratory of Eco-Environment of Three Gorges Region of Ministry of Education

    5 shared publications
  • Junhua Chen

    Key Laboratory on Luminescence and Real-Time Analysis (Southwest University), Ministry of Education, School of Chemistry and Chemical Engineering, Southwest University, Chongqing, China

    4 shared publications

Latest Publications

  • A novel colorimetric probe with positive correlation between toxicity and the reaction for the assessment of chromium ions

    by Jingzhou Hou, Zhengfan Shui, Jiawei Li, Danqun Huo, Xiaohui Tang, Chenhui Yu, Qiang He, Cailin Qiao

    We report a novel, rapid, simple and accurate probe for the detection of Cr 3+ and Cr 6+ .


  • A turn-on fluorescent sensor based on carbon dots from Sophora japonica leaves for the detection of glyphosate

    by Jingzhou Hou, Xianfeng Wang, Shiyu Lan, Chao Zhang, Changjun Hou, Qiang He, Danqun Huo

    Carbon dots (CDs) having low cost and low toxicity and synthesized via a green route were applied to establish a fluorescent nanoprobe for the measurement of glyphosate. The synthesis was realized via a one-pot hydrothermal procedure using Sophora japonica leaves as the carbon source. It was found that electron transfer occurred between Fe3+ and the as-prepared CDs. Therefore, Fe3+ exhibited a specific dynamic-quenching toward CDs. However, the electron transfer process was inhibited by glyphosate. The fluorescence of the quenched CDs/Fe3+ system was recovered by the addition of glyphosate. It resulted from the strong complexation between Fe3+ and the functional groups (like –PO3H2 and –COOH) in the glyphosate molecule. These functional groups captured Fe3+ from the CD/Fe3+ system to reduce the electron transfer. With such a design, the rapid detection of glyphosate could be realized by this turn-on fluorescent sensor based on the CD/Fe3+ system. Under optimal conditions, the CD/Fe3+ system showed a concentration-dependent fluorescent response toward glyphosate in the linear range from 0.1 to 16 ppm. The limit of detection was calculated to be as low as 8.75 ppb (3σ/S). In addition, the successful detection of glyphosate in real samples with satisfactory recoveries exhibited a practical application of the CD/Fe3+ nanoprobe in food safety and environmental monitoring.


  • Determination of organophosphorus pesticides and their major degradation product residues in food samples by HPLC-UV

    by Guilong Peng, Qiang He, Ying Lu, Daniel Mmereki, Zhihui Zhong

    A simple method based on dispersive solid-phase extraction (DSPE) and dispersive liquid–liquid microextraction method based on solidification of floating organic droplets (DLLME-SFO) was developed for the extraction of chlorpyrifos (CP), chlorpyrifos-methyl (CPM), and their main degradation product 3,5,6-trichloro-2-pyridinol (TCP) in tomato and cucumber samples. The determination was carried out by high performance liquid chromatography with ultraviolet detection (HPLC-UV). In the DSPE-DLLME-SFO, the analytes were first extracted with acetone. The clean-up of the extract by DSPE was carried out by directly adding activated carbon sorbent into the extract solution, followed by shaking and filtration. Under the optimum conditions, the proposed method was sensitive and showed a good linearity within a range of 2–500 ng/g, with the correlation coefficients (r) varying from 0.9991 to 0.9996. The enrichment factors ranged from 127 to 138. The limit of detections (LODs) were in the range of 0.12–0.68 ng/g, and the relative standard deviations (RSDs) for 50 ng/g of each analytes in tomato samples were in the range of 3.25–6.26 % (n = 5). The proposed method was successfully applied for the extraction and determination of the mentioned analytes residues in tomato and cucumber samples, and satisfactory results were obtained.


  • Vortex-assisted surfactant-enhanced-emulsification liquid–liquid microextraction with solidification of floating organic droplet combined with flame atomic absorption spectrometry for the fast determination of cadmium in water samples

    by Guilong Peng, Ying Lu, Qiang He, Daniel Mmereki, Xiaohui Tang, Zhihui Zhong, Xiaolong Zhao

    A novel vortex-assisted surfactant-enhanced-emulsification liquid–liquid microextraction with solidification of floating organic droplet (VSLLME-SFO) was developed for the fast, simple and efficient determination of cadmium (Cd) in water samples followed by flame atomic absorption spectrometry. In VSLLME-SFO process, the addition of surfactant (as an emulsifier), could enhance the mass-transfer from the aqueous solution into the extraction solvent. The extraction solvent could be dispersed into the aqueous under vigorously shaking with the vortex. In this paper, we investigated the influences of analytical parameters, including pH, extraction solvent type and its volume, surfactant type and its volume, concentration of chelating agent, salt effect and vortex time on the extraction efficiency of Cd were investigated. Under the optimized conditions, the limit of detection was 0.16 μg/L. The analyte enrichment factor was 37.68. The relative standard deviation was 3.2% (10 μg/L, n = 10) and the calibration graph was linear ranging from 0.5–30 μg/L. The proposed method was successfully applied for the analysis of ultra trace Cd in river water and wastewater samples.


  • Dispersive solid phase extraction followed by low-toxicity vortex-assisted liquid–liquid microextraction for the determination of organophosphorus pesticides by high-performance liquid chromatography

    by Guilong Peng, Qiang He, Ying Lu, Daniel Mmereki, Zhihui Zhong, Kaiyong Jiang, Dingjun Chen

    A simple, rapid and environmentally friendly method for the determination of organophosphorus pesticides (OPPs) in soil and cucumber samples was developed by using dispersive solid phase extraction and low-toxicity vortex-assisted liquid–liquid microextraction (DSPE-LT-VALLME) and high performance liquid chromatography with ultraviolet detection (HPLC-UV). Clean-up of the extract from soil and cucumber was conducted by DSPE using multi-walled carbon nanotubes (MWCNTs) as the sorbent. Parameters that could influence the extraction efficiencies, including the type and volume of extraction solvent, time of the vortex, pH of the sample solution and salt addition, were investigated. The linearity of the method was in the range from 1.0 to 600 ng g−1 with correlation coefficients (r) ranging from 0.9992 to 0.9999. The limits of detection (LODs) were 0.018 to 0.12 ng g−1. The relative standard deviations (RSDs) varied from 1.66% to 3.62% (n = 6), and the enrichment factors (EFs) for the target analytes were in the range of 128–136. Finally, the proposed method has been successfully applied to the determination of target analytes in real samples. The recoveries of the target analytes in soil and cucumber samples were between 83.10% and 101.20%.


  • Dispersive solid‐phase extraction followed by vortex‐assisted dispersive liquid–liquid microextraction based on the solidification of a floating organic droplet for the determination of benzoylurea insecticides in soil and sewage sludge

    by Guilong Peng, Qiang He, Daniel Mmereki, Ying Lu, Zhihui Zhong, Hanyang Liu, Weiliang Pan, Guangming Zhou, Junhua Chen

    A novel dispersive solid‐phase extraction combined with vortex‐assisted dispersive liquid–liquid microextraction based on solidification of floating organic droplet was developed for the determination of eight benzoylurea insecticides in soil and sewage sludge samples before high‐performance liquid chromatography with ultraviolet detection. The analytes were first extracted from the soil and sludge samples into acetone under optimized pretreatment conditions. Clean‐up of the extract was conducted by dispersive solid‐phase extraction using activated carbon as the sorbent. The vortex‐assisted dispersive liquid–liquid microextraction based on solidification of floating organic droplet procedure was performed by using 1‐undecanol with lower density than water as the extraction solvent, and the acetone contained in the solution also acted as dispersive solvent. Under the optimum conditions, the linearity of the method was in the range 2–500 ng/g with correlation coefficients (r) of 0.9993–0.9999. The limits of detection were in the range of 0.08–0.56 ng/g. The relative standard deviations varied from 2.16 to 6.26% (n = 5). The enrichment factors ranged from 104 to 118. The extraction recoveries ranged from 81.05 to 97.82% for all of the analytes. The good performance has demonstrated that the proposed methodology has a strong potential for application in the multiresidue analysis of complex matrices.


  • Determination of Lead in Water Samples Using a New Vortex-Assisted, Surfactant-Enhanced Emulsification Liquid–Liquid Microextraction Combined with Graphite Furnace Atomic Absorption Spectrometry

    by Guilong Peng, Qiang He, Ying Lu, Daniel Mmereki, Weiliang Pan, Xiaohui Tang, Guangming Zhou, Yufeng Mao, Xaioxuan Su

    A low toxic solvent-based vortex-assisted surfactant-enhanced emulsification liquid–liquid microextraction (LT-VSLLME) combined with graphite furnace atomic absorption spectrometry was developed for the extraction and determination of lead (Pb) in water samples. In the LT-VSLLME method, the extraction solvent was dispersed into the aqueous samples by the assistance of vortex agitator. Meanwhile, the addition of a surfactant, which acted as an emulsifier, could enhance the speed of the mass-transfer from aqueous samples to the extraction solvent. The influences of analytical parameters, including extraction solvent type and its volume, surfactant type and its volume, pH, concentration of chelating agent, salt effect and extraction time were investigated. Under the optimized conditions, a good relative standard deviation of 3.69 % at 10 ng L−1 was obtained. The calibration graph showed a linear pattern in the ranges of 5–30 ngL−1, with a limit of detection of 0.76 ng L−1. The linearity was obtained by five points in the concentration range of 5–30 ngL−1. The enrichment factor was 320. The procedure was applied to wastewater and river water, and the accuracy was assessed through the analysis of the recovery experiments.


  • Determination of 3,5,6‐trichloro‐2‐pyridinol, phoxim and chlorpyrifos‐methyl in water samples using a new pretreatment method coupled with high‐performance liquid chromatography

    by Guilong Peng, Ying Lu, Qiang He, Daniel Mmereki, Guangming Zhou, Junhua Chen, Xiaohui Tang

    A novel low‐density solvent‐based vortex‐assisted surfactant‐enhanced‐emulsification liquid–liquid microextraction with the solidification of floating organic droplet method coupled with high‐performance liquid chromatography was developed for the determination of 3,5,6‐trichloro‐2‐pyridinol, phoxim and chlorpyrifos‐methyl in water samples. In this method, the addition of a surfactant could enhance the speed of the mass transfer from the sample solution into the extraction solvent. The extraction solvent could be dispersed into the aqueous by the vortex process. The main parameters affecting the extraction efficiency were investigated and the optimum conditions were established as follows: 80 μL 1‐undecanol as extraction solvent, 0.2 mmol/L of Triton X‐114 selected as the surfactant, the vortex time was fixed at 60 s with the vortex agitator set at 3000 rpm, the concentration of acetic acid in sample solution was 0.4% v/v and 1.0 g addition of NaCl. Under the optimum conditions, the enrichment factors were from 172 to 186 for the three analytes. The linear ranges were from 0.5 to 500 μg/L with a coefficient of determination (r2) of between 0.9991 and 0.9995. Limits of detections were varied between 0.05 and 0.12 μg/L. The relative standard deviations (n = 6) ranged from 0.26 to 2.62%.


  • Vortex‐assisted liquid–liquid microextraction using a low‐toxicity solvent for the determination of five organophosphorus pesticides in water samples by high‐performance liquid chromatography

    by Guilong Peng, Qiang He, Daniel Mmereki, Guangming Zhou, Weiliang Pan, Li Gu, Leilei Fan, Xiaohui Tang, Junhua Chen, Yufeng Mao

    Vortex‐assisted liquid–liquid microextraction followed by high‐performance liquid chromatography with UV detection was applied to determine Isocarbophos, Parathion‐methyl, Triazophos, Phoxim and Chlorpyrifos‐methyl in water samples. 1‐Bromobutane was used as the extraction solvent, which has a higher density than water and low toxicity. Centrifugation and disperser solvent were not required in this microextraction procedure. The optimum extraction conditions for 15 mL water sample were: pH of the sample solution, 5; volume of the extraction solvent, 80 μL; vortex time, 2 min; salt addition, 0.5 g. Under the optimum conditions, enrichment factors ranging from 196 to 237 and limits of detection below 0.38 μg/L were obtained for the determination of target pesticides in water. Good linearities (r > 0.9992) were obtained within the range of 1–500 μg/L for all the compounds. The relative standard deviations were in the range of 1.62–2.86% and the recoveries of spiked samples ranged from 89.80 to 104.20%. The whole proposed methodology is simple, rapid, sensitive and environmentally friendly for determining traces of organophosphorus pesticides in the water samples.