QCQueenie Chan

Queenie Chan

*This is an algorithmically generated author record based on publicly available information.

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Queenie Chan has a total of 41 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • The application of T2W SPIR-FLAIR in the diagnosis of hip synovitis in patients with spondyloarthritis

    by Zhen-Guo Huang, Xiao-Liang Chen, Kai-Ning Shi, Ran Yan, He Chen, Min-Xing Yang, Bao-Xiang Gao, Queenie Chan, Guo-Chun Wang

    To investigate the feasibility and accuracy of T2 weighted spectral pre-saturation inversion recovery combined with fluid-attenuated inversion recovery (T2W SPIR-FLAIR) in the diagnosis of hip synovitis in patients with spondyloarthritis (SpA). 10 volunteers underwent a T2W SPIR and 4 T2W SPIR-FLAIR sequence scans with different inversion times (TIs) to determine the optimum TI that could effectively suppress the intra-articular fluid signals. Hip MRI including T2W SPIR-FLAIR and enhanced T1 weighted (T1W) SPIR sequences was performed in 45 patients with SpA and totally 90 hips were evaluated. McNemar's test and Kappa test were used to compare the diagnostic results of synovitis between T2W SPIR-FLAIR and enhanced T1W SPIR. A TI of 2100 ms was selected as the optimum TI. 32 hips from 17 patients exhibited high signal intensity within the articular cavity on both T2W SPIR-FLAIR and enhanced T1W SPIR sequences, while only 3 hips showed high signals within the articular cavity on T2W SPIR-FLAIR. The remaining 55 hips did not show high signals within the articular cavity on both sequences. The T2W SPIR-FLAIR and enhanced T1W SPIR sequences had similar values in the diagnosis of hip synovitis (p = 0.25) and a high degree of diagnostic consistency (Kappa = 0.929). T2W SPIR-FLAIR can effectively suppress the intra-articular fluid signals, while retaining the signals of thickened synovial membranes and can be used for the diagnosis of hip synovitis in patients with SpA. The enhanced T1W SPIR is a classic sequence for synovitis diagnosis, but it requires the injection of contrast agents. The T2W SPIR-FLAIR and enhanced T1W SPIR sequences had similar values in the diagnosis of hip synovitis (p = 0.25) and a high degree of diagnostic consistency (Kappa = 0.929).


  • Correlation between intravoxel incoherent motion MR parameters and MR nodular grade of parotid glands in patients with Sjögren’s syndrome: A pilot study

    by Chen Chu, Nan Zhou, Huayong Zhang, Xin Dou, Ming Li, Song Liu, Yun Zhu, Weibo Chen, Queenie Chan, Jian He, et al.


  • Intravoxel incoherent motion MR imaging for breast lesions: comparison and correlation with pharmacokinetic evaluation from dynamic contrast-enhanced MR imaging

    by Chunling Liu, Kun Wang, Queenie Chan, Zaiyi Liu, Jine Zhang, Hui He, Shuixing Zhang, Changhong Liang

    Objectives To compare diagnostic performance for breast lesions by quantitative parameters derived from intravoxel incoherent motion (IVIM) and dynamic contrast-enhanced (DCE) magnetic resonance imaging (MRI) and to explore whether correlations exist between these parameters. Methods IVIM and DCE MRI were performed on a 1.5-T MRI scanner in patients with suspicious breast lesions. Thirty-six breast cancers and 23 benign lesions were included in the study. Quantitative parameters from IVIM (D, f and D*) and DCE MRI (Ktrans, Kep, Ve and Vp) were calculated and compared between malignant and benign lesions. Spearman correlation test was used to evaluate correlations between them. Results D, f, D* from IVIM and Ktrans, Kep, Vp from DCE MRI were statistically different between breast cancers and benign lesions (p < 0.05, respectively) and D demonstrated the largest area under the receiver-operating characteristic curve (AUC = 0.917) and had the highest specificity (83 %). The f value was moderately statistically correlated with Vp (r = 0.692) and had a poor correlation with Ktrans (r = 0.456). Conclusions IVIM MRI is useful in the differentiation of breast lesions. Significant correlations were found between perfusion-related parameters from IVIM and DCE MRI. IVIM may be a useful adjunctive tool to standard MRI in diagnosing breast cancer. Key Points • IVIM provided diffusion as well as perfusion information • IVIM could help differential diagnosis of breast lesions • Correlations were found between perfusion-related parameters from IVIM and DCE MRI


  • Intravoxel water diffusion heterogeneity MR imaging of nasopharyngeal carcinoma using stretched exponential diffusion model

    by Vincent Lai, Victor Ho Fun Lee, Ka On Lam, Henry Chun Kin Sze, Queenie Chan, Pek Lan Khong

    To determine the utility of stretched exponential diffusion model in characterisation of the water diffusion heterogeneity in different tumour stages of nasopharyngeal carcinoma (NPC). Fifty patients with newly diagnosed NPC were prospectively recruited. Diffusion-weighted MR imaging was performed using five b values (0–2,500 s/mm2). Respective stretched exponential parameters (DDC, distributed diffusion coefficient; and alpha (α), water heterogeneity) were calculated. Patients were stratified into low and high tumour stage groups based on the American Joint Committee on Cancer (AJCC) staging for determination of the predictive powers of DDC and α using t test and ROC curve analyses. The mean ± standard deviation values were DDC = 0.692 ± 0.199 (×10−3 mm2/s) for low stage group vs 0.794 ± 0.253 (×10−3 mm2/s) for high stage group; α = 0.792 ± 0.145 for low stage group vs 0.698 ± 0.155 for high stage group. α was significantly lower in the high stage group while DDC was negatively correlated. DDC and α were both reliable independent predictors (p < 0.001), with α being more powerful. Optimal cut-off values were (sensitivity, specificity, positive likelihood ratio, negative likelihood ratio) DDC = 0.692 × 10−3 mm2/s (94.4 %, 64.3 %, 2.64, 0.09), α = 0.720 (72.2 %, 100 %, −, 0.28). The heterogeneity index α is robust and can potentially help in staging and grading prediction in NPC. • Stretched exponential diffusion models can help in tissue characterisation in nasopharyngeal carcinoma • α and distributed diffusion coefficient (DDC) are negatively correlated • α is a robust heterogeneity index marker • α can potentially help in staging and grading prediction


  • Open Access

    Relationship between intravoxel incoherent motion diffusion-weighted MRI and dynamic contrast-enhanced MRI in tissue perfusion of cervical cancers

    by Elaine Yuen Phin Lee, Edward Sai Kam Hui, Karen Kar Loen Chan, Ka Yu Tse, Wai Kay Kwong, Tien Yee Chang, Queenie Chan, Pek-Lan Khong

    Purpose To investigate the relationship between intravoxel incoherent motion (IVIM) diffusion-weighted magnetic resonance imaging (MRI) and dynamic contrast-enhanced MRI (DCE-MRI) in cervical cancer perfusion. Materials and Methods Prospective newly diagnosed cervical cancer patients underwent diffusion-weighted MRI (13 b-values: 1–1000 s/mm2) and DCE-MRI. The IVIM perfusion parameters, perfusion fraction (f), pseudodiffusion coefficient (D*), and flow-related parameter (fD*), were derived from a biexponential decay model. DCE-MRI was analyzed with a pharmacokinetic model and signal-time curve to derive the amplitude factor (A), estimated volume transfer constant between blood plasma, and the extravascular extracellular space (estKtrans), maximum relative enhancement (MaxRE), and area under the signal-time curve (AUC). Spearman's rank correlation coefficient (r) evaluated the correlative relationships. Results The f = 13.51% ± 1.76%, D* = 71.72 ± 7.55 × 10−3 mm2/s, fD* = 9.64 ± 1.28 × 10−3 mm2/s, A = 1.41 ± 0.43, estKtrans = 0.19 ± 0.06 s−1, MaxRE of 120.02 ± 21.07%, and AUC 212,393 ± 54,423 was found in 25 cervical cancer patients. Statistically significant positive correlations were found between fD* and estKtrans (r = 0.42, P = 0.038), fD* and A (r = 0.50, P = 0.011), fD* and MaxRE (r = 0.52, P = 0.008), f and AUC (r = 0.58, P = 0.003). Conclusion: The IVIM perfusion parameters showed moderate to good correlations with quantitative and semiquantitative perfusion parameters derived from DCE-MRI in cervical cancer. J. Magn. Reson. Imaging 2014. J. Magn. Reson. Imaging 2015;42:454–459.


  • Dual-source parallel RF transmission for diffusion-weighted imaging of the abdomen using different b values: Image quality and apparent diffusion coefficient comparison with conventional single-source transmission

    by Lijun Guo, Cheng Liu, Weibo Chen, Queenie Chan, Guangbin Wang

    Purpose: To prospectively and intraindividually evaluate what effects dual‐source parallel radiofrequency (RF) transmission have on image quality and apparent diffusion coefficient (ADC) of abdomen diffusion‐weighted imaging (DWI) using different b values, compared with the single‐source RF transmission. Materials and Methods: Eighteen healthy male volunteers were enrolled in this Health Insurance Portability and Accountability Act (HIPAA)‐compliant Institutional Review Board (IRB)‐approved study. Abdominal DWI was performed with dual‐source and single‐source RF transmission at 3.0 T using a series of b‐value combinations: 0/100, 0/500, 0/800, and 0/100/800. RF field homogeneity, subjective image quality, and signal to noise ratio (SNR) of each abdominal organ were evaluated. ADC values were calculated for each abdominal organ. Wilcoxon test and repeated‐measures analysis of variance was used to calculate statistical significance. Results: The parallel RF transmission significantly improved homogeneity of the RF field (P = 0.0001–0.008) and subjective image quality (P < 0.0001) at each b value and also increased SNR. At lower and higher b value, the measured ADC of lateral left hepatic lobe and spleen between dual‐source and single‐source images were significantly different (P = 0.0001–0.047). At b = 0/500, there was no significant difference in ADC measurements between dual‐source and single‐source RF transmission for abdominal organs, except a slight statistically significant difference for spleen (P = 0.047). Conclusion: Parallel RF transmission significantly improved the image quality and homogeneity of the RF field. The RF transmission had a significant influence on measured ADC of lateral left hepatic lobe and spleen. At b = 0/500 the influence was minimum for all abdominal organs. J. Magn. Reson. Imaging 2013;37:875–885.