Chris H. Fraser
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Chris H. Fraser has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
Alberto Murino
Wolfson Unit for Endoscopy, St Mark's Hospital, London, United Kingdom
6 shared publicationsMasanao Nakamura
4 shared publicationsAine O'Rouke
3 shared publications- Edward John Despott
Royal Free Unit for Endoscopy The Royal Free Hospital and University College London (UCL) Institute for Liver and Digestive Health London UK
3 shared publications Adam Humphries
Wolfson Unit for Endoscopy, St Mark's Hospital, London, United Kingdom
1 shared publication- Aine J. O'Rourke
St. Mark’s Hospital and Academic Institute, Imperial College London
1 shared publication
Latest Publications
- 1 June 2018
- Published by Elsevier in Gastrointestinal Endoscopy
- Vol. 87 (6) , AB64
177 SINGLE INCISION LAPAROSCOPIC ASSISTED DOUBLE BALLOON ENTEROSCOPY: A NOVEL TECHNIQUE TO MANAGE SMALL BOWEL PATHOLOGY
- 1 June 2018
- Published by Elsevier in Gastrointestinal Endoscopy
- Vol. 87 (6) , AB64
177 SINGLE INCISION LAPAROSCOPIC ASSISTED DOUBLE BALLOON ENTEROSCOPY: A NOVEL TECHNIQUE TO MANAGE SMALL BOWEL PATHOLOGY
- 6 January 2015
- Published by Springer Nature in Digestive Diseases and Sciences
- Vol. 60 (6) , 1743-1747
A Critical Analysis of the Effect of View Mode and Frame Rate on Reading Time and Lesion Detection During Capsule Endoscopy
Factors influencing reading time and detection of lesions include the view mode (VM) and frame rate (FR) applied during reading of small bowel capsule endoscopy images. The aims of this study were to examine the impact of VM and FR on reading time and lesion detection using a standardized, single-type lesion model. A selected video clip containing a known number of positive images (n = 60) of small bowel angioectasias was read using nine different combinations of VM and FR (VM1, VM2, and VM4 × FR10, FR15, and FR25) in randomized order by six capsule endoscopists. Readers were asked to count all positive images of angioectasias (maximum number of positive images, MPIs) seen during reading. The main outcome measurements were effect of VM and FR on reading time and lesion detection. Mean MPIs for all VM2 and VM4 were 36 (60 %) and 38 (64 %). They were significantly higher than VM1 of 24 (40 %) (P = 0.011, 0.008). A statistical difference was found when the total MPIs at FR10 were compared to FR15 (P = 0.008) and to FR25 (P < 0.001). Both VM and FR significantly influence lesion detection during capsule endoscopy reading.
- 6 January 2015
- Published by Springer Nature in Digestive Diseases and Sciences
- Vol. 60 (6) , 1743-1747
A Critical Analysis of the Effect of View Mode and Frame Rate on Reading Time and Lesion Detection During Capsule Endoscopy
Factors influencing reading time and detection of lesions include the view mode (VM) and frame rate (FR) applied during reading of small bowel capsule endoscopy images. The aims of this study were to examine the impact of VM and FR on reading time and lesion detection using a standardized, single-type lesion model. A selected video clip containing a known number of positive images (n = 60) of small bowel angioectasias was read using nine different combinations of VM and FR (VM1, VM2, and VM4 × FR10, FR15, and FR25) in randomized order by six capsule endoscopists. Readers were asked to count all positive images of angioectasias (maximum number of positive images, MPIs) seen during reading. The main outcome measurements were effect of VM and FR on reading time and lesion detection. Mean MPIs for all VM2 and VM4 were 36 (60 %) and 38 (64 %). They were significantly higher than VM1 of 24 (40 %) (P = 0.011, 0.008). A statistical difference was found when the total MPIs at FR10 were compared to FR15 (P = 0.008) and to FR25 (P < 0.001). Both VM and FR significantly influence lesion detection during capsule endoscopy reading.
- 1 May 2014
- Published by Elsevier in Gastrointestinal Endoscopy
- Vol. 79 (5) , AB123
223 Should MR Enterography Be the Preferred Surveillance Modality Compared to Small Bowel Capsule Endoscopy in Peutz- Jegher's Syndrome?
- 1 May 2014
- Published by Elsevier in Gastrointestinal Endoscopy
- Vol. 79 (5) , AB123
223 Should MR Enterography Be the Preferred Surveillance Modality Compared to Small Bowel Capsule Endoscopy in Peutz- Jegher's Syndrome?
- 1 April 2012
- Published by Elsevier in Gastrointestinal Endoscopy
- Vol. 75 (4) , AB265
Sa1756 Factors Influencing Insertion Depth at Double Balloon Enteroscopy: A Prospective Analysis
- 1 April 2012
- Published by Elsevier in Gastrointestinal Endoscopy
- Vol. 75 (4) , AB265
Sa1756 Factors Influencing Insertion Depth at Double Balloon Enteroscopy: A Prospective Analysis
- 1 April 2012
- Published by Elsevier in Gastrointestinal Endoscopy
- Vol. 75 (4) , AB253
Sa1717 Improving Efficiency in Capsule Endoscopy - Can Reading Times Be Reduced Without Sacrificing Diagnostic Accuracy? A Self - Assessment
- 1 April 2012
- Published by Elsevier in Gastrointestinal Endoscopy
- Vol. 75 (4) , AB253
Sa1717 Improving Efficiency in Capsule Endoscopy - Can Reading Times Be Reduced Without Sacrificing Diagnostic Accuracy? A Self - Assessment
- 1 April 2012
- Published by Elsevier in Gastrointestinal Endoscopy
- Vol. 75 (4) , AB266
Sa1757 Improvement in Diagnostic Ability of Small Bowel Lesion is Associated With Use of FICE During Capsule Endoscopy: A Pilot Study
- 1 April 2012
- Published by Elsevier in Gastrointestinal Endoscopy
- Vol. 75 (4) , AB266
Sa1757 Improvement in Diagnostic Ability of Small Bowel Lesion is Associated With Use of FICE During Capsule Endoscopy: A Pilot Study
- 1 April 2012
- Published by Elsevier in Gastrointestinal Endoscopy
- Vol. 75 (4) , AB253-AB254
Sa1718 The Effect of Frame Rate and View Mode on Lesion Detectability by Novice and Expert Capsule Endoscopists During Reading
- 1 April 2012
- Published by Elsevier in Gastrointestinal Endoscopy
- Vol. 75 (4) , AB253-AB254
Sa1718 The Effect of Frame Rate and View Mode on Lesion Detectability by Novice and Expert Capsule Endoscopists During Reading
- 1 May 2011
- Published by Elsevier in Gastroenterology
- Vol. 140 (5)
First Evaluation of Multi-Modal FICE for Detection and Differentiation of Small Bowel Lesions at Capsule Endoscopy
- 1 May 2011
- Published by Elsevier in Gastroenterology
- Vol. 140 (5)
First Evaluation of Multi-Modal FICE for Detection and Differentiation of Small Bowel Lesions at Capsule Endoscopy