LHLucie Habartová

Lucie Habartová

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Lucie Habartová has a total of 50 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • LABORATORY DIAGNOSIS OF HEPATOCELLULAR CARCINOMA - CONVENTIONAL BIOMARKERS AND BLOOD PLASMA SPECTROSCOPY

    by Petr Hříbek, Lucie Habartová, Johana Klasová, Kristýna Kubíčková, Tomáš Kupsa, Tomáš Tůma, Vladimír Setnička, Petr Urbánek

  • Open Access

    Vibrational and chiroptical analysis of blood plasma for hepatocellular carcinoma diagnostics

    by OndřEj Vrtělka, KateřIna Králová, Markéta Fousková, Lucie Habartová, Petr Hříbek, Petr Urbánek, Vladimír Setnička

    Using a combination of vibrational and chiroptical spectroscopy together with principal component analysis and a random forest algorithm, we have successfully distinguished patients with hepatocellular carcinoma from patients with cirrhosis.


  • Open Access

    In vivo Raman spectroscopy in the diagnostics of colon cancer

    by Markéta Fousková, Jan Vališ, Alla Synytsya, Lucie Habartová, Jaromír Petrtýl, Luboš Petruželka, Vladimír Setnička

    In vivo Raman spectroscopy coupled with machine learning methods was used for tissue diagnostics of precancerous and cancerous lesions of the colon and rectum.


  • The potential of spectroscopy in the diagnosis of hepatocellular carcinoma – a pilot study

    by Petr Hříbek, Lucie Habartová, Kristýna Kubíčková, Johana Klasová, Vladimír Setnička, Petr Urbánek

    Summary: None of the bio­markers studied so far in the HCC area has yielded higher sensitivity and specificity in the early-stage dia­gnosis than the liver ultrasonography examination. There is an urgent clinical need for establishing a laboratory marker for HCC that meets the requirements for high sensitivity and specificity for the screening and early dia­gnosis of at-risk patients. As a variety of pathological processes, including carcinogenesis, may cause changes in both the concentration and the structure and spatial arrangement of body bio­molecules, the spectroscopic analysis of blood-based derivatives appears to be an appropriate tool for the early detection thereof. In our research, the focus is on the identification of novel bio­markers in blood plasma, which would exhibit sufficient sensitivity and specificity to detect early and potentially curable HCC stages, and which would be potentially useful for routine screening of this disease in well-defined at-risk groups. For this purpose, we utilised a unique combination of two chiroptical methods – electronic circular dichroism (ECD) and Raman optical activity (ROA) – supplemented by non-polarised variants – infrared (IR) absorption and Raman spectroscopy. Methods: Blood plasma of 18 selected patients with liver cirrhosis, 8 of which also suffered from HCC, was analysed by a combination of ECD, ROA, IR and Raman spectroscopy. Results: The obtained spectral data were processed by a multivariate statistical evaluation using principal component analysis (PCA) and linear discriminant analysis (LDA). The visualisation of the LDA results showed the separation of the two monitored groups with only a slight overlap. Based on the spectral analysis within this preliminary study, sensitivity and specificity for the discrimination between cirrhotic individuals with and without HCC reached 88% and 90% after leave-one-out cross validation, respectively. The area under the ROC curve of 0.975 proved high reliability of the established model. Conclusion: Based on our findings, the combination of advanced spectroscopic methods for the analysis of blood plasma might be a promising tool in HCC dia­gnosis and potentially in the screening thereof. Key words: hepatocellular carcinoma – blood plasma – spectroscopy – cirrhosis


  • Open Access

    Chiral detection by induced surface-enhanced Raman optical activity

    by Moumita Das, Debraj Gangopadhyay, Jaroslav Šebestík, Lucie Habartová, Pavel Michal, Josef Kapitán, Petr Bouř

    Combination of optical activity with surface-enhanced Raman scattering has been a dream of physical chemists for a long time. We report a measurement protocol based on silver colloids and aromatic linkers where chiral acids could be detected in concentrations of about 10−5 M. We explain the mechanism by binding and self-assembly of the linkers into chiral aggregates on the silver surface. Following the “sergeants-and-soldiers” principle, the chirality is determined by the relatively minor acidic component. Such detection of biologically relevant molecules may be useful when other methods, such as electronic circular dichroism, are not sensitive enough. In the future, variations of the chemical structure of the linker or other conditions are needed to provide a more specific signal allowing one to better discriminate among the optically active molecules.


  • Blood-based molecular signature of Alzheimer's disease via spectroscopy and metabolomics

    by Lucie Habartová, Kateřina Hrubešová, Kamila Syslová, Jana Vondroušová, Zdeněk Fišar, Roman Jirák, Jiří Raboch, Vladimír Setnička


  • Plasma amyloid beta levels and platelet mitochondrial respiration in patients with Alzheimer's disease

    by Zdeněk Fišar, Roman Jirák, Martina Zvěřová, Vladimír Setnička, Lucie Habartová, Jana Hroudová, Zdislava Vaníčková, Jiří Raboch


  • Diagnosis of pancreatic cancer via 1 H NMR metabolomics of human plasma

    by Lenka Michálková, Štěpán Horník, Jan Sýkora, Lucie Habartová, Vladimír Setnička

    The investigation of blood plasma via 1 H NMR metabolomics revealed a panel of potential biomarkers of pancreatic cancer.


  • Chiroptical spectroscopy and metabolomics for blood‐based sensing of pancreatic cancer

    by Lucie Habartová, Bohuš Bunganič, Michal Tatarkovič, Miroslav Zavoral, Jana Vondroušová, Kamila Syslová, Vladimír Setnička

    To enable the early diagnosis of pancreatic cancer, the search for and definition of reliable biomarkers remain a subject of great interest, with the specificity and sensitivity of the currently used biomarkers being below the required values. We tested a novel diagnostic approach for pancreatic cancer based on the specific molecular signature of blood plasma components. To acquire more detailed structural information, structure‐sensitive chiroptical methods (electronic circular dichroism and Raman optical activity) were supplemented by conventional Raman and infrared spectroscopies. The obtained spectra were subsequently processed by linear discriminant analysis yielding high values of specificity and sensitivity. In addition, to monitor not only large biomolecules as potential biomarkers but also those of low molecular weight, we conducted an analysis of blood plasma samples by using metabolomics. The achieved results suggest a panel of promising biomarkers for a reliable detection of pancreatic cancer.


  • Electronic circular dichroism for the detection of microalbuminuria

    by Lucie Habartová, Hana Logerová, Lukáš Tomaník, Aneta Marešová, Vladimír Setnička

    Over the past decades, chiroptical spectroscopy has proved its incomparable ability to elucidate the structure and spatial arrangement of chiral molecules. Systematic analysis of biomolecules in the natural environment of biofluids, however, remains challenging. In this study, we used chiroptical spectroscopy to monitor urinary levels of human serum albumin. Not only severe proteinuria but even just a slightly increased urinary excretion of albumin (microalbuminuria) may indicate serious health complications, especially for diabetic individuals. Given the chiral nature of albumin and its typical spectral pattern, it may be easily observable by chiroptical spectroscopy, particularly electronic circular dichroism. The performed chiroptical analysis of urine not only allowed the detection of clinically confirmed microalbuminuria but was also able to reveal this pathological condition in cases beyond the diagnostic capability of common clinical procedures. Thus, our approach suggests that electronic circular dichroism is a useful tool for the fast and reliable qualitative monitoring of microalbuminuria with the potential for a quantitative analysis in the future.