Sophie Debord
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Sophie Debord has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Claude Guérin
Université Claude Bernard Lyon I, Faculté de Médecine Lyon-Est, Lyon, France
5 shared publications - Jean-Christophe Richard
Service de Médecine Intensive Réanimation, Hôpital de la Croix Rousse, Hospices Civils de Lyon, Lyon, France
5 shared publications - Véronique Leray
Service de Réanimation Médicale, Hôpital De La Croix Rousse, Hospices Civils de Lyon, 103 Grande Rue de la Croix Rousse, 69004, Lyon, France.
4 shared publications - Frédérique Bayle
Service de Réanimation Médicale, Hôpital De La Croix Rousse, Hospices Civils de Lyon, 103 Grande Rue de la Croix Rousse, 69004, Lyon, France.
3 shared publications - Gael Bourdin
Service de Réanimation Médicale, Hôpital De La Croix Rousse, Hospices Civils de Lyon, 103 Grande Rue de la Croix Rousse, 69004, Lyon, France.
3 shared publications - Hodane Yonis
Service de Réanimation Médicale, Hôpital De La Croix Rousse, Hospices Civils de Lyon, 103 Grande Rue de la Croix Rousse, 69004, Lyon, France.
3 shared publications
Latest Publications
- Open Access
- 5 December 2017
- Published by Springer Nature in Critical Care
- Vol. 21 (1) , 1-12
Change in cardiac output during Trendelenburg maneuver is a reliable predictor of fluid responsiveness in patients with acute respiratory distress syndrome in the prone position under protective ventilation
Predicting fluid responsiveness may help to avoid unnecessary fluid administration during acute respiratory distress syndrome (ARDS). The aim of this study was to evaluate the diagnostic performance of the following methods to predict fluid responsiveness in ARDS patients under protective ventilation in the prone position: cardiac index variation during a Trendelenburg maneuver, cardiac index variation during an end-expiratory occlusion test, and both pulse pressure variation and change in pulse pressure variation from baseline during a tidal volume challenge by increasing tidal volume (VT) to 8 ml.kg-1. This study is a prospective single-center study, performed in a medical intensive care unit, on ARDS patients with acute circulatory failure in the prone position. Patients were studied at baseline, during a 1-min shift to the Trendelenburg position, during a 15-s end-expiratory occlusion, during a 1-min increase in VT to 8 ml.kg-1, and after fluid administration. Fluid responsiveness was deemed present if cardiac index assessed by transpulmonary thermodilution increased by at least 15% after fluid administration. There were 33 patients included, among whom 14 (42%) exhibited cardiac arrhythmia at baseline and 15 (45%) were deemed fluid-responsive. The area under the receiver operating characteristic (ROC) curve of the pulse contour-derived cardiac index change during the Trendelenburg maneuver and the end-expiratory occlusion test were 0.90 (95% CI, 0.80–1.00) and 0.65 (95% CI, 0.46–0.84), respectively. An increase in cardiac index ≥ 8% during the Trendelenburg maneuver enabled diagnosis of fluid responsiveness with sensitivity of 87% (95% CI, 67–100), and specificity of 89% (95% CI, 72–100). The area under the ROC curve of pulse pressure variation and change in pulse pressure variation during the tidal volume challenge were 0.52 (95% CI, 0.24–0.80) and 0.59 (95% CI, 0.31–0.88), respectively. Change in cardiac index during a Trendelenburg maneuver is a reliable test to predict fluid responsiveness in ARDS patients in the prone position, while neither change in cardiac index during end-expiratory occlusion, nor pulse pressure variation during a VT challenge reached acceptable predictive performance to predict fluid responsiveness in this setting. ClinicalTrials.gov, NCT01965574 . Registered on 16 October 2013. The trial was registered 6 days after inclusion of the first patient.
- 5 December 2017
- Published by Springer Nature in Critical Care
- Vol. 21 (1) , 1-12
Open AccessChange in cardiac output during Trendelenburg maneuver is a reliable predictor of fluid responsiveness in patients with acute respiratory distress syndrome in the prone position under protective ventilation
Predicting fluid responsiveness may help to avoid unnecessary fluid administration during acute respiratory distress syndrome (ARDS). The aim of this study was to evaluate the diagnostic performance of the following methods to predict fluid responsiveness in ARDS patients under protective ventilation in the prone position: cardiac index variation during a Trendelenburg maneuver, cardiac index variation during an end-expiratory occlusion test, and both pulse pressure variation and change in pulse pressure variation from baseline during a tidal volume challenge by increasing tidal volume (VT) to 8 ml.kg-1. This study is a prospective single-center study, performed in a medical intensive care unit, on ARDS patients with acute circulatory failure in the prone position. Patients were studied at baseline, during a 1-min shift to the Trendelenburg position, during a 15-s end-expiratory occlusion, during a 1-min increase in VT to 8 ml.kg-1, and after fluid administration. Fluid responsiveness was deemed present if cardiac index assessed by transpulmonary thermodilution increased by at least 15% after fluid administration. There were 33 patients included, among whom 14 (42%) exhibited cardiac arrhythmia at baseline and 15 (45%) were deemed fluid-responsive. The area under the receiver operating characteristic (ROC) curve of the pulse contour-derived cardiac index change during the Trendelenburg maneuver and the end-expiratory occlusion test were 0.90 (95% CI, 0.80–1.00) and 0.65 (95% CI, 0.46–0.84), respectively. An increase in cardiac index ≥ 8% during the Trendelenburg maneuver enabled diagnosis of fluid responsiveness with sensitivity of 87% (95% CI, 67–100), and specificity of 89% (95% CI, 72–100). The area under the ROC curve of pulse pressure variation and change in pulse pressure variation during the tidal volume challenge were 0.52 (95% CI, 0.24–0.80) and 0.59 (95% CI, 0.31–0.88), respectively. Change in cardiac index during a Trendelenburg maneuver is a reliable test to predict fluid responsiveness in ARDS patients in the prone position, while neither change in cardiac index during end-expiratory occlusion, nor pulse pressure variation during a VT challenge reached acceptable predictive performance to predict fluid responsiveness in this setting. ClinicalTrials.gov, NCT01965574 . Registered on 16 October 2013. The trial was registered 6 days after inclusion of the first patient.
- Open Access
- 23 February 2016
- Published by Springer Nature in Critical Care
- Vol. 20 (1) , 44
Prevalence and risk factors of hypotension associated with preload-dependence during intermittent hemodialysis in critically ill patients
Background: Hypotension is a frequent complication of intermittent hemodialysis (IHD) performed in intensive care units (ICUs). Passive leg raising (PLR) combined with continuous measurement of cardiac output is highly reliable to identify preload dependence, and may provide new insights into the mechanisms involved in IHD-related hypotension. The aim of this study was to assess prevalence and risk factors of preload dependence-related hypotension during IHD in the ICU. Methods: A single-center prospective observational study performed on ICU patients undergoing IHD for acute kidney injury and monitored with a PiCCO® device. Primary end points were the prevalence of hypotension (defined as a mean arterial pressure below 65 mm Hg) and hypotension associated with preload dependence. Preload dependence was assessed by the passive leg raising test, and considered present if the systolic ejection volume increased by at least 10 % during the test, as assessed continuously by the PiCCO® device. Results: Forty-seven patients totaling 107 IHD sessions were included. Hypotension was observed in 61 IHD sessions (57 %, CI95%: 47–66 %) and was independently associated with inotrope administration, higher SOFA score, lower time lag between ICU admission and IHD session, and lower MAP at IHD session onset. Hypotension associated with preload dependence was observed in 19 % (CI95%: 10–31 %) of sessions with hypotension, and was associated with mechanical ventilation, lower SAPS II, higher pulmonary vascular permeability index (PVPI) and dialysate sodium concentration at IHD session onset. ROC curve analysis identified PVPI and mechanical ventilation as the only variables with significant diagnostic performance to predict hypotension associated with preload dependence (respective AUC: 0.68 (CI95%: 0.53–0.83) and 0.69 (CI95%: 0.54–0.85). A PVPI ≥ 1.6 at IHD session onset predicted occurrence of hypotension associated with preload dependence during IHD with a sensitivity of 91 % (CI95%: 59–100 %), and a specificity of 53 % (CI95%: 42–63 %). Conclusions: The majority of hypotensive episodes occurring during intermittent hemodialysis are unrelated to preload dependence and should not necessarily lead to reduction of fluid removal by hemodialysis. However, high PVPI at IHD session onset and mechanical ventilation are risk factors of preload dependence-related hypotension, and should prompt reduction of planned fluid removal during the session, and/or an increase in session duration.
- 23 February 2016
- Published by Springer Nature in Critical Care
- Vol. 20 (1) , 44
Open AccessPrevalence and risk factors of hypotension associated with preload-dependence during intermittent hemodialysis in critically ill patients
Background: Hypotension is a frequent complication of intermittent hemodialysis (IHD) performed in intensive care units (ICUs). Passive leg raising (PLR) combined with continuous measurement of cardiac output is highly reliable to identify preload dependence, and may provide new insights into the mechanisms involved in IHD-related hypotension. The aim of this study was to assess prevalence and risk factors of preload dependence-related hypotension during IHD in the ICU. Methods: A single-center prospective observational study performed on ICU patients undergoing IHD for acute kidney injury and monitored with a PiCCO® device. Primary end points were the prevalence of hypotension (defined as a mean arterial pressure below 65 mm Hg) and hypotension associated with preload dependence. Preload dependence was assessed by the passive leg raising test, and considered present if the systolic ejection volume increased by at least 10 % during the test, as assessed continuously by the PiCCO® device. Results: Forty-seven patients totaling 107 IHD sessions were included. Hypotension was observed in 61 IHD sessions (57 %, CI95%: 47–66 %) and was independently associated with inotrope administration, higher SOFA score, lower time lag between ICU admission and IHD session, and lower MAP at IHD session onset. Hypotension associated with preload dependence was observed in 19 % (CI95%: 10–31 %) of sessions with hypotension, and was associated with mechanical ventilation, lower SAPS II, higher pulmonary vascular permeability index (PVPI) and dialysate sodium concentration at IHD session onset. ROC curve analysis identified PVPI and mechanical ventilation as the only variables with significant diagnostic performance to predict hypotension associated with preload dependence (respective AUC: 0.68 (CI95%: 0.53–0.83) and 0.69 (CI95%: 0.54–0.85). A PVPI ≥ 1.6 at IHD session onset predicted occurrence of hypotension associated with preload dependence during IHD with a sensitivity of 91 % (CI95%: 59–100 %), and a specificity of 53 % (CI95%: 42–63 %). Conclusions: The majority of hypotensive episodes occurring during intermittent hemodialysis are unrelated to preload dependence and should not necessarily lead to reduction of fluid removal by hemodialysis. However, high PVPI at IHD session onset and mechanical ventilation are risk factors of preload dependence-related hypotension, and should prompt reduction of planned fluid removal during the session, and/or an increase in session duration.
- Open Access
- 1 December 2015
- Published by Springer Nature in Critical Care
- Vol. 19 (1) , 5
Preload dependence indices to titrate volume expansion during septic shock: a randomized controlled trial
Introduction: In septic shock, pulse pressure or cardiac output variation during passive leg raising are preload dependence indices reliable at predicting fluid responsiveness. Therefore, they may help to identify those patients who need intravascular volume expansion, while avoiding unnecessary fluid administration in the other patients. However, whether their use improves septic shock prognosis remains unknown. The aim of this study was to assess the clinical benefits of using preload dependence indices to titrate intravascular fluids during septic shock.Methods: In a single-center randomized controlled trial, 60 septic shock patients were allocated to preload dependence indices-guided (preload dependence group) or central venous pressure-guided (control group) intravascular volume expansion with 30 patients in each group. The primary end point was time to shock resolution, defined by vasopressor weaning.Results: There was no significant difference in time to shock resolution between groups (median (interquartile range) 2.0 (1.2 to 3.1) versus 2.3 (1.4 to 5.6) days in control and preload dependence groups, respectively). The daily amount of fluids administered for intravascular volume expansion was higher in the control than in the preload dependence group (917 (639 to 1,511) versus 383 (211 to 604) mL,P = 0.01), and the same held true for red cell transfusions (178 (82 to 304) versus 103 (0 to 183) mL,P = 0.04). Physiologic variable values did not change over time between groups, except for plasma lactate (time over group interaction,PP = 0.10). Intravascular volume expansion was lower in the preload dependence group for patients with lower simplified acute physiology score II (SAPS II), and the opposite was found for patients in the upper two SAPS II quartiles. The amount of intravascular volume expansion did not change across the quartiles of severity in the control group, but steadily increased with severity in the preload dependence group.Conclusions: In patients with septic shock, titrating intravascular volume expansion with preload dependence indices did not change time to shock resolution, but resulted in less daily fluids intake, including red blood cells, without worsening patient outcome.Trial registration: Clinicaltrials.govNCT01972828. Registered 11 October 2013.
- 1 December 2015
- Published by Springer Nature in Critical Care
- Vol. 19 (1) , 5
Open AccessPreload dependence indices to titrate volume expansion during septic shock: a randomized controlled trial
Introduction: In septic shock, pulse pressure or cardiac output variation during passive leg raising are preload dependence indices reliable at predicting fluid responsiveness. Therefore, they may help to identify those patients who need intravascular volume expansion, while avoiding unnecessary fluid administration in the other patients. However, whether their use improves septic shock prognosis remains unknown. The aim of this study was to assess the clinical benefits of using preload dependence indices to titrate intravascular fluids during septic shock.Methods: In a single-center randomized controlled trial, 60 septic shock patients were allocated to preload dependence indices-guided (preload dependence group) or central venous pressure-guided (control group) intravascular volume expansion with 30 patients in each group. The primary end point was time to shock resolution, defined by vasopressor weaning.Results: There was no significant difference in time to shock resolution between groups (median (interquartile range) 2.0 (1.2 to 3.1) versus 2.3 (1.4 to 5.6) days in control and preload dependence groups, respectively). The daily amount of fluids administered for intravascular volume expansion was higher in the control than in the preload dependence group (917 (639 to 1,511) versus 383 (211 to 604) mL,P = 0.01), and the same held true for red cell transfusions (178 (82 to 304) versus 103 (0 to 183) mL,P = 0.04). Physiologic variable values did not change over time between groups, except for plasma lactate (time over group interaction,PP = 0.10). Intravascular volume expansion was lower in the preload dependence group for patients with lower simplified acute physiology score II (SAPS II), and the opposite was found for patients in the upper two SAPS II quartiles. The amount of intravascular volume expansion did not change across the quartiles of severity in the control group, but steadily increased with severity in the preload dependence group.Conclusions: In patients with septic shock, titrating intravascular volume expansion with preload dependence indices did not change time to shock resolution, but resulted in less daily fluids intake, including red blood cells, without worsening patient outcome.Trial registration: Clinicaltrials.govNCT01972828. Registered 11 October 2013.
- Open Access
- 1 January 2013
- Published by Herbert Publications PVT LTD in Journal of Medical Disorders
- Vol. 1 (1)
Pink skin, urine and effluent fluid after cyanide poisoning
- 1 January 2013
- Published by Herbert Publications PVT LTD in Journal of Medical Disorders
- Vol. 1 (1)
Open AccessPink skin, urine and effluent fluid after cyanide poisoning
- Open Access
- 1 January 2011
- Published by Elsevier in Annals of Intensive Care
- Vol. 1 (1) , 9
Efficacy and safety of recruitment maneuvers in acute respiratory distress syndrome
- 1 January 2011
- Published by Elsevier in Annals of Intensive Care
- Vol. 1 (1) , 9
Open AccessEfficacy and safety of recruitment maneuvers in acute respiratory distress syndrome