Zhenming Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Zhenming Li has a total of 33 co-authors. Here are the top co-authors by number of shared publications:
- Wei Liu
Energy Storage and Novel Technology of Electrical Engineering Department, China Electric Power Research Institute, Beijing 100192, China
6 shared publications - Mingyang Liu
Energy Storage Research Institute, China Electric Power Research Institute (CEPRI), Beijing 100192, China
4 shared publications - Lin Gui
State Key Laboratory of Cryogenic Science and Technology and Beijing Key Laboratory of CryoBiomedicine, Technical Institute of Physics and Chemistry, Chinese Academy of Sciences, Beijing, China
3 shared publications - Pan Zhang
CAS Key Laboratory of Cryogenics, Technical Institute of Physics and Chemistry, Chinese Academy of Sciences, Beijing 100190, China
2 shared publications - Yongling Lu
Electric Power Research Institute, State Grid Jiangsu Electric Power Co., Ltd, NanJing, China, China
2 shared publications - Zhen Wang
Research Institute of State Grid Jiangsu Electric Power Co., Ltd., Nanjing 211103, China
2 shared publications
Latest Publications
- Open Access
Development of a PCM-Integrated Radiant Cold-Storage System: Radiative-Cooling Film, Water Tank Design, and Outdoor Performance Validation
Outdoor environments typically require intensive cooling during the day, while nighttime cooling demands are comparatively modest. Conventional radiative-cooling systems deliver strong cooling at night but often underperform during daytime solar exposure. Here, we develop a PCM-integrated radiative cold-storage system (RCSS) that couples a polymer metasurface radiative-cooling (PMRC) film with a paraffin cold-storage tank via a helical-tube heat exchanger, and validate it through outdoor tests supplemented by CFD-based analysis. Under representative outdoor conditions, the RCSS cools circulating water at an average nighttime rate of 3.1 K h−1 and maintains stable performance for initial water temperatures of 25–55 °C. Using PMRC’s cooling power as the benchmark for effective radiative-cooling power, we quantify the system-level heat-transfer pathways and provide design sensitivities with respect to film area, exchanger geometry, and tank dimensions. The results establish a practical route to all-day thermal management by storing “cold” at night and releasing it on demand, thereby facilitating scalable deployment of radiative-cooling technologies.
Open AccessDevelopment of a PCM-Integrated Radiant Cold-Storage System: Radiative-Cooling Film, Water Tank Design, and Outdoor Performance Validation
Outdoor environments typically require intensive cooling during the day, while nighttime cooling demands are comparatively modest. Conventional radiative-cooling systems deliver strong cooling at night but often underperform during daytime solar exposure. Here, we develop a PCM-integrated radiative cold-storage system (RCSS) that couples a polymer metasurface radiative-cooling (PMRC) film with a paraffin cold-storage tank via a helical-tube heat exchanger, and validate it through outdoor tests supplemented by CFD-based analysis. Under representative outdoor conditions, the RCSS cools circulating water at an average nighttime rate of 3.1 K h−1 and maintains stable performance for initial water temperatures of 25–55 °C. Using PMRC’s cooling power as the benchmark for effective radiative-cooling power, we quantify the system-level heat-transfer pathways and provide design sensitivities with respect to film area, exchanger geometry, and tank dimensions. The results establish a practical route to all-day thermal management by storing “cold” at night and releasing it on demand, thereby facilitating scalable deployment of radiative-cooling technologies.
- Open Access
Transformer Monitoring with Electromagnetic Energy Transmission and Wireless Sensing
To ensure stable and normal transformer operation, light gas protection of the transformer Buchholz relay is essential. However, false alarms related to light gas protection are common, and troubleshooting them often requires on-site gas sampling by personnel. During this time, the transformer’s operating state may rapidly deteriorate, posing a safety threat to field staff. To tackle these challenges, this work presents the near-field, thin-sliced transformer monitoring system that uses Electromagnetic Energy Transmission and Wireless Sensing Device (ETWSD). The system leverages external wireless energy input to power gas monitoring sensors. Simultaneously, it employs Near-Field Communication to obtain real-time concentrations of light gases, along with the electrified state and temperature. In field testing conducted on transformer relays’ gas collection chambers, the ETWSD effortlessly monitors parameters within warning ranges, encompassing methane gas concentrations around 1000 ppm, leakage voltage ranging from 0–100 V, and relay working temperatures up to 90 °C. Additionally, to facilitate real-time diagnosis for electrical workers, we have developed an Android-based APP software that displays current light gas concentrations, leakage voltage collection values, and temperature, while also enabling threshold judgment, alarms, and data storage. The developed ETWSD is expected to aid on-site personnel in promptly and accurately evaluating transformer light gas protection error alarm faults. It provides a method for simultaneous, contactless, and rapid monitoring of multiple indicators.
Open AccessTransformer Monitoring with Electromagnetic Energy Transmission and Wireless Sensing
To ensure stable and normal transformer operation, light gas protection of the transformer Buchholz relay is essential. However, false alarms related to light gas protection are common, and troubleshooting them often requires on-site gas sampling by personnel. During this time, the transformer’s operating state may rapidly deteriorate, posing a safety threat to field staff. To tackle these challenges, this work presents the near-field, thin-sliced transformer monitoring system that uses Electromagnetic Energy Transmission and Wireless Sensing Device (ETWSD). The system leverages external wireless energy input to power gas monitoring sensors. Simultaneously, it employs Near-Field Communication to obtain real-time concentrations of light gases, along with the electrified state and temperature. In field testing conducted on transformer relays’ gas collection chambers, the ETWSD effortlessly monitors parameters within warning ranges, encompassing methane gas concentrations around 1000 ppm, leakage voltage ranging from 0–100 V, and relay working temperatures up to 90 °C. Additionally, to facilitate real-time diagnosis for electrical workers, we have developed an Android-based APP software that displays current light gas concentrations, leakage voltage collection values, and temperature, while also enabling threshold judgment, alarms, and data storage. The developed ETWSD is expected to aid on-site personnel in promptly and accurately evaluating transformer light gas protection error alarm faults. It provides a method for simultaneous, contactless, and rapid monitoring of multiple indicators.
- Open Access
- 29 December 2023
- Published by MDPI AG in Micromachines
- Vol. 15 (1) , 75
A Novel Flexible Liquid Metal Microheater with a Textured Structure
In this paper, we propose a novel liquid metal microheater utilizing a textured structure. This microheater effectively solves the problem of the liquid metal in the PDMS flow channel fracturing at a certain temperature and significantly increases the maximum operating temperature that can be achieved by the current liquid metal microheater. Experimental results demonstrate that this new structured microheater can achieve a maximum operating temperature exceeding 300 °C. To explain the performance improvement and the reasons behind liquid metal fracture, corresponding experiments were conducted, and explanations were provided based on the experimental results. Subsequently, we verified the mechanical flexibility of the microheater and found that it exhibits excellent tensile and bending resistance. Finally, utilizing its good mechanical flexibility, the microheater was successfully attached to the side wall of a cup, resulting in the boiling of water.
- 29 December 2023
- Published by MDPI AG in Micromachines
- Vol. 15 (1) , 75
Open AccessA Novel Flexible Liquid Metal Microheater with a Textured Structure
In this paper, we propose a novel liquid metal microheater utilizing a textured structure. This microheater effectively solves the problem of the liquid metal in the PDMS flow channel fracturing at a certain temperature and significantly increases the maximum operating temperature that can be achieved by the current liquid metal microheater. Experimental results demonstrate that this new structured microheater can achieve a maximum operating temperature exceeding 300 °C. To explain the performance improvement and the reasons behind liquid metal fracture, corresponding experiments were conducted, and explanations were provided based on the experimental results. Subsequently, we verified the mechanical flexibility of the microheater and found that it exhibits excellent tensile and bending resistance. Finally, utilizing its good mechanical flexibility, the microheater was successfully attached to the side wall of a cup, resulting in the boiling of water.
- Open Access
- 5 July 2023
- Published by MDPI AG in Electronics
- Vol. 12 (13) , 2962
Design of a Wide-Range and High-Precision Analog Front-End Circuit for Multi-Parameter Sensors
This article presents a wide-range and high-precision analog front-end circuit for multi-parameter sensors that can handle sensor outputs of different types (R, C, V). A rail-to-rail baseline compensation method has been proposed, which further incorporates a fine offset elimination of 0.6 mV/step. Additionally, self-zeroing and correlated double-sampling techniques are integrated to reduce low-frequency noise and offset, prevent sensor signal saturation, and enhance the precision of the analog front-end circuit. By incorporating variable components in the sensor signal acquisition circuit and integrating them with the baseline compensation circuit, the applicability range of the sensor has been expanded (R: 7 –1.7 M, C: 50 fF–35 pF, V: 0.05–1.7 V). Test results show all interface circuits exhibit significant total conversion gains (C: 45 mV/fF, R: 14.5 mV/, V: 144 V/V), achieving high precision. Meanwhile, a coefficient of determination () greater than 0.998 indicates high conversion linearity of the circuit.- 5 July 2023
- Published by MDPI AG in Electronics
- Vol. 12 (13) , 2962
Open AccessDesign of a Wide-Range and High-Precision Analog Front-End Circuit for Multi-Parameter Sensors
This article presents a wide-range and high-precision analog front-end circuit for multi-parameter sensors that can handle sensor outputs of different types (R, C, V). A rail-to-rail baseline compensation method has been proposed, which further incorporates a fine offset elimination of 0.6 mV/step. Additionally, self-zeroing and correlated double-sampling techniques are integrated to reduce low-frequency noise and offset, prevent sensor signal saturation, and enhance the precision of the analog front-end circuit. By incorporating variable components in the sensor signal acquisition circuit and integrating them with the baseline compensation circuit, the applicability range of the sensor has been expanded (R: 7 –1.7 M, C: 50 fF–35 pF, V: 0.05–1.7 V). Test results show all interface circuits exhibit significant total conversion gains (C: 45 mV/fF, R: 14.5 mV/, V: 144 V/V), achieving high precision. Meanwhile, a coefficient of determination () greater than 0.998 indicates high conversion linearity of the circuit. - Open Access
- 23 March 2023
- Published by MDPI AG in Micromachines
- Vol. 14 (4) , 717
Pressure Driven Rapid Reconfigurable Liquid Metal Patterning
This paper proposes a method for pressure driven rapid reconfigurable liquid metal patterning. A sandwich structure of “pattern—film—cavity” is designed to complete this function. Both sides of the highly elastic polymer film are bonded with two PDMS slabs. One PDMS slab has microchannels patterned on the surface. The other PDMS slab has a large cavity on its surface for liquid metal storage. These two PDMS slabs are bonded together, face to face, with the polymer film in the middle. In order to control the distribution of the liquid metal in the microfluidic chip, the elastic film will deform under the high pressure of the working medium in the microchannels and then extrude the liquid metal into different patterns in the cavity. This paper studies the factors of liquid metal patterning in detail, including external control conditions, such as the type and pressure of the working medium and the critical dimensions of the chip structure. Moreover, both a single-pattern and a double-pattern chip are fabricated in this paper, which can form or reconfigure the liquid metal pattern within 800 ms. Based on the above methods, reconfigurable antennas of two frequencies are designed and fabricated. Meanwhile, their performance is simulated and tested by simulation and vector network tests. The operating frequencies of the two antennas are respectively significantly switching between 4.66 GHz and 9.97 GHz.
- 23 March 2023
- Published by MDPI AG in Micromachines
- Vol. 14 (4) , 717
Open AccessPressure Driven Rapid Reconfigurable Liquid Metal Patterning
This paper proposes a method for pressure driven rapid reconfigurable liquid metal patterning. A sandwich structure of “pattern—film—cavity” is designed to complete this function. Both sides of the highly elastic polymer film are bonded with two PDMS slabs. One PDMS slab has microchannels patterned on the surface. The other PDMS slab has a large cavity on its surface for liquid metal storage. These two PDMS slabs are bonded together, face to face, with the polymer film in the middle. In order to control the distribution of the liquid metal in the microfluidic chip, the elastic film will deform under the high pressure of the working medium in the microchannels and then extrude the liquid metal into different patterns in the cavity. This paper studies the factors of liquid metal patterning in detail, including external control conditions, such as the type and pressure of the working medium and the critical dimensions of the chip structure. Moreover, both a single-pattern and a double-pattern chip are fabricated in this paper, which can form or reconfigure the liquid metal pattern within 800 ms. Based on the above methods, reconfigurable antennas of two frequencies are designed and fabricated. Meanwhile, their performance is simulated and tested by simulation and vector network tests. The operating frequencies of the two antennas are respectively significantly switching between 4.66 GHz and 9.97 GHz.
- Open Access
- 14 June 2022
- Published by MDPI AG in Bioengineering
- Vol. 9 (6) , 254
A Liquid Metal-Enhanced Wearable Thermoelectric Generator
It is a key challenge to continuously power personal wearable health monitoring systems. This paper reports a novel liquid metal-enhanced wearable thermoelectric generator (LM-WTEG that directly converts body heat into electricity for powering the wearable sensor system. The gallium-based liquid metal alloys with room-temperature melting point (24~30 °C) and high latent heat density (about 500 MJ/m3) are used to design a new flexible finned heat sink, which not only absorbs the heat through the solid-liquid phase change of the LM and enhances the heat release to the ambient air due to its high thermal conduction. The LM finned is integrated with WTEG to present high biaxial flexibility, which could be tightly in contact with the skin. The LM-WTEG could achieve a super high output power density of 275 μW/cm2 for the simulated heat source (37 °C) with the natural convective heat transfer condition. The energy management unit, the multi-parameter sensors (including temperature, humidity, and accelerometer), and Bluetooth module with a total energy consumption of about 65 μW are designed, which are fully powered from LM-WTEG through harvesting body heat.
- 14 June 2022
- Published by MDPI AG in Bioengineering
- Vol. 9 (6) , 254
Open AccessA Liquid Metal-Enhanced Wearable Thermoelectric Generator
It is a key challenge to continuously power personal wearable health monitoring systems. This paper reports a novel liquid metal-enhanced wearable thermoelectric generator (LM-WTEG that directly converts body heat into electricity for powering the wearable sensor system. The gallium-based liquid metal alloys with room-temperature melting point (24~30 °C) and high latent heat density (about 500 MJ/m3) are used to design a new flexible finned heat sink, which not only absorbs the heat through the solid-liquid phase change of the LM and enhances the heat release to the ambient air due to its high thermal conduction. The LM finned is integrated with WTEG to present high biaxial flexibility, which could be tightly in contact with the skin. The LM-WTEG could achieve a super high output power density of 275 μW/cm2 for the simulated heat source (37 °C) with the natural convective heat transfer condition. The energy management unit, the multi-parameter sensors (including temperature, humidity, and accelerometer), and Bluetooth module with a total energy consumption of about 65 μW are designed, which are fully powered from LM-WTEG through harvesting body heat.
- Open Access
- 24 January 2020
- Published by MDPI AG in Micromachines
- Vol. 11 (2) , 133
A Performance-Enhanced Liquid Metal-Based Microheater with Parallel Ventilating Side-Channels
Gallium-based liquid metal can be used as a material for microheaters because it can be easily filled into microchannels and electrified to generate Joule heat, but the liquid metal-based microheater will suffer breakage induced by voids forming within the liquid metal when the temperature normally gets higher than 100 °C. To resolve this problem, a novel liquid metal-based microheater with parallel ventilating side-channels is presented. It consists of a liquid-metal heating channel and two parallel ventilating side-channels. The heating channel is connected with the side-channels by small gaps between polydimethylsiloxane (PDMS) posts. Experimental results show that this novel microheater can be heated up to 200 °C without damage. To explain its excellent performance, an experiment is performed to discover the development of the voids within the liquid-metal heating channel, and two reasons are put forward in this work on the basis of the experiment. Afterward pressing and bending tests are conducted to explore the mechanical stability of the novel microheaters. Finally, the microheaters are applied to warm water to show their good flexibility on non-flat surfaces. In consequence, the novel liquid metal-based microheater is believed to be widely applicable to soft micro-electro-mechanical system(MEMS) heating devices.
- 24 January 2020
- Published by MDPI AG in Micromachines
- Vol. 11 (2) , 133
Open AccessA Performance-Enhanced Liquid Metal-Based Microheater with Parallel Ventilating Side-Channels
Gallium-based liquid metal can be used as a material for microheaters because it can be easily filled into microchannels and electrified to generate Joule heat, but the liquid metal-based microheater will suffer breakage induced by voids forming within the liquid metal when the temperature normally gets higher than 100 °C. To resolve this problem, a novel liquid metal-based microheater with parallel ventilating side-channels is presented. It consists of a liquid-metal heating channel and two parallel ventilating side-channels. The heating channel is connected with the side-channels by small gaps between polydimethylsiloxane (PDMS) posts. Experimental results show that this novel microheater can be heated up to 200 °C without damage. To explain its excellent performance, an experiment is performed to discover the development of the voids within the liquid-metal heating channel, and two reasons are put forward in this work on the basis of the experiment. Afterward pressing and bending tests are conducted to explore the mechanical stability of the novel microheaters. Finally, the microheaters are applied to warm water to show their good flexibility on non-flat surfaces. In consequence, the novel liquid metal-based microheater is believed to be widely applicable to soft micro-electro-mechanical system(MEMS) heating devices.