PAPierre-Jean Arnoux

Pierre-Jean Arnoux

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Pierre-Jean Arnoux has a total of 42 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Biomechanical comparison of spinal cord compression types occurring in Degenerative Cervical Myelopathy

    by Simon Lévy, Guillaume Baucher, Pierre-Hugues Roche, Morgane Evin, Virginie Callot, Pierre-Jean Arnoux


  • Open Access

    Effect of experimental, morphological and mechanical factors on the murine spinal cord subjected to transverse contusion: A finite element study

    by Marion Fournely, Yvan Petit, Eric Wagnac, Morgane Evin, Pierre-Jean Arnoux

    Finite element models combined with animal experimental models of spinal cord injury provides the opportunity for investigating the effects of the injury mechanism on the neural tissue deformation and the resulting tissue damage. Thus, we developed a finite element model of the mouse cervical spinal cord in order to investigate the effect of morphological, experimental and mechanical factors on the spinal cord mechanical behavior subjected to transverse contusion. The overall mechanical behavior of the model was validated with experimental data of unilateral cervical contusion in mice. The effects of the spinal cord material properties, diameter and curvature, and of the impactor position and inclination on the strain distribution were investigated in 8 spinal cord anatomical regions of interest for 98 configurations of the model. Pareto analysis revealed that the material properties had a significant effect (p<0.01) for all regions of interest of the spinal cord and was the most influential factor for 7 out of 8 regions. This highlighted the need for comprehensive mechanical characterization of the gray and white matter in order to develop effective models capable of predicting tissue deformation during spinal cord injuries.


  • Analysis of trunk impact conditions in motorcycle road accidents based on epidemiological, accidentological data and multibody simulations

    by Oscar Cherta Ballester, Maxime Llari, Sanae Afquir, Jean-Louis Martin, Nicolas Bourdet, Valentin Honoré, Catherine Masson, Pierre-Jean Arnoux


  • Assessing the Global Range of Motion of the Helmeted Head Through Rotational and Translational Measurements

    by Brieg Lecoublet, Dominic Boisclair, Morgane Evin, Eric Wagnac, Yvan Petit, Carl-Eric Aubin, Pierre-Jean Arnoux

    This work aimed to describe the helmeted head mobility as a combination of rotations and translations during functional head movements. A motion capture system was used to follow six optoelectronic markers placed on a motorcycle helmet worn by volunteers performing head motions (flexion-extension (FE), axial rotation (AR) and lateral bending (LB)). Maximum angular rotations and linear displacements were computed to assess intra-class correlation coefficients, standard errors of measurement and minimal detectable changes. Rotational range of motion was 101.9° (SD 17.8°) for FE, 78.8° (SD 13.8°) for LB and 124.7° (SD 27.5°) for AR. Linear range of motion was 255.8 mm (SD 53.5 mm), 217.6 mm (SD 35.7 mm) and 74.7 mm (SD 26.3 mm), respectively, for anteroposterior, lateral and inferior displacements. Assessing rotational and translational mobility of the helmeted head could also support validation of human models, and evaluate how safety devices could restrain head neck mobility before crash.


  • Open Access

    Experimental assessment of cervical ranges of motion and compensatory strategies

    by Céline Niewiadomski, Rohan-Jean Bianco, Sanae Afquir, Morgane Evin, Pierre-Jean Arnoux

    Literature is still limited regarding reports of non-invasive assessment of the cervical range of motion in normal subjects. Investigations into compensatory motions, defined as the contribution of an additional direction to the required motion, are also limited. The objectives of this work were to develop and assess a reliable method for measuring the cervical range of motion in order to investigate motion and compensatory strategies. Ninety-seven no neck-related pain subjects (no severe cervical pathology, 57 women, age: 28.3 ± 7.5y. old, BMI: 22.5 ± 3.2 kg/m2) underwent a non-invasive cervical range of motion assessment protocol. In-vivo head’s motion relative to the thorax was assessed through the measurement of the main angular amplitudes in the 3 directions (flexion/extension, axial rotations and lateral inclinations) and associated compensatory motions using an opto-electronic acquisition system. The principal motion reproducibility resulted in intra-class correlation coefficients ranging from 0.81 to 0.86. The following maximum ranges of motion were found: 127.4 ± 15.1° of flexion/extension, 89.3 ± 12° of lateral inclinations and 146.4 ± 13° of axial rotations after 6 outlier exclusions. Compensatory motions highly depend on the associated principal motion: for flexion/extension: (3.5 ± 7.6;-2.1 ± 7.8°), for rotation: (25.7 ± 17.9°;0.4 ± 4.7)°, for inclination: (22.9 ± 34.7°;-0.04 ± 8.7°). Age, BMI and weight significantly correlated with flexions (p < 0.032). Motion patterns were identified through clustering. This kinematic analysis has been proven to be a reliable diagnostic tool for the cervical range of motion. The non-unicity and variability of motion patterns through the clustering of motion strategy identification have been shown. Compensatory motions contributed to such motion pattern definition despite presenting significant intra-individual variability.


  • High-speed video analysis improves the accuracy of spinal cord compression measurement in a mouse contusion model

    by Marion Fournely, Yvan Petit, Éric Wagnac, Jérôme Laurin, Virginie Callot, Pierre-Jean Arnoux


  • Open Access

    A finite element model of the lower limb during stance phase of gait cycle including the muscle forces

    by Arnaud Diffo Kaze, Stefan Maas, Pierre-Jean Arnoux, Claude Wolf, Dietrich Pape

    Results of finite element (FE) analyses can give insight into musculoskeletal diseases if physiological boundary conditions, which include the muscle forces during specific activities of daily life, are considered in the FE modelling. So far, many simplifications of the boundary conditions are currently made. This study presents an approach for FE modelling of the lower limb for which muscle forces were included. The stance phase of normal gait was simulated. Muscle forces were calculated using a musculoskeletal rigid body (RB) model of the human body, and were subsequently applied to a FE model of the lower limb. It was shown that the inertial forces are negligible during the stance phase of normal gait. The contact surfaces between the parts within the knee were modelled as bonded. Weak springs were attached to the distal tibia for numerical reasons. Hip joint reaction forces from the RB model and those from the FE model were similar in magnitude with relative differences less than 16%. The forces of the weak spring were negligible compared to the applied muscle forces. The maximal strain was 0.23% in the proximal region of the femoral diaphysis and 1.7% in the contact zone between the tibia and the fibula. The presented approach based on FE modelling by including muscle forces from inverse dynamic analysis of musculoskeletal RB model can be used to perform analyses of the lower limb with very realistic boundary conditions. In the present form, this model can be used to better understand the loading, stresses and strains of bones in the knee area and hence to analyse osteotomy fixation devices.


  • Temporal bone fracture under lateral impact: biomechanical and macroscopic evaluation

    by Marion Montava, Catherine Masson, Jean-Pierre Lavieille, Julien Mancini, Jerome Soussan, Kathia Chaumoitre, Pierre-Jean Arnoux

    This work was conducted to study biomechanical properties and macroscopic analysis of petrous fracture by lateral impact. Seven embalmed intact human cadaver heads were tested to failure using an electrohydraulic testing device. Dynamic loading was done at 2 m/s on temporal region with maximal deflection to 12 mm. Anthropometric and pathological data were determined by pretest and posttest computed tomography images, macroscopic evaluation, and anatomical dissection. Biomechanical data were obtained. Results indicated the head to have nonlinear structural response. The overall mean values of failure forces, deflections, stiffness, occipital, and frontal peak acceleration were 7.1 kN (±1.1), 9.1 mm (±1.8), 1.3 kN/mm (±0.4), 90.5 g (±22.5), and 65.4 g (±16), respectively. The seven lateral impacts caused fractures, temporal fractures in six cases. We observed very strong homogeneity for the biomechanical and pathological results between different trials in our study and between data from various experiments and our study. No statistical correlation was found between anthropometric, biomechanical, and pathological data. These data will assist in the development and validation of finite element models of head injury.


  • Characterizing the Importance of Free Space in the Numerical Human Body Models

    by Omar Chebil, Pierre-Jean Arnoux, Michel Behr

    The geometric fidelity of the inner organs on finite-element model (FEM) of the human body and the choice to use discontinuous mesh engender the appearance of empty spaces that do not reflect the real-life situation of human body cavities. The aim of this study is to assess the influence of these empty spaces on the behavior of a simplified FEM built with three different structures in interaction which properties are relevant with the abdominal cavity. This FEM is made up of a large sphere (peritoneum) containing two hemispheres (liver and spleen). The space between peritoneum and inner organs was defined with two different approaches and assessed under impact conditions. The first is a meshfree space (Mfs) approach, e.g., consider the space as a perfect gas. The second approach, meshed space (MS), entailed adding volumetric elements in the empty space. From each approach, one optimal configuration was identified regarding the recorded force versus compression, the mobility of inner organs, and the space incompressibility. This space has a considerable influence on the behavior of the FEM and mainly on the applied loadings of inner organs (difference reaching 70% according to the configuration). For the first approach, the incompressible gas is designated because it guarantees space incompressibility (vf/vi = 1) and inner organs loading with the lowest delay (for high impact velocity: Peak force = 89 N, compression 47%). For the second approach, the discontinuous volumetric mesh is preferred because it promotes space incompressibility (vf/vi = 0.94) and acceptable force reaction (for high impact velocity: Peak force = 97 N, compression 49%). The current study shows the importance of this space on the human FEMs cavities behavior and proposes two configurations able to be used in a future study including detailed FEM.