Christopher Wright
Research Subjects
Christopher Wright has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Andrew Porter
3810 St. Antoine W, Montreal, QC, H4C 1B4, Canada
2 shared publications - Brad Rodu
James Graham Brown Cancer Center, University of Louisville, Louisville, USA
2 shared publications - Harriet Kimpton
Group Research & Development, British American Tobacco, Regents Park Road, Southampton, SO15 8TL, UK
2 shared publications - Kevin McAdam
Group Research & Development, British American Tobacco, Regents Park Road, Southampton, SO15 8TL, UK.
2 shared publications - Arif Faizi
Group Research & Development, British American Tobacco, Regents Park Road, Southampton, SO15 8TL, UK
1 shared publication C. H. A. Goss
British American Tobacco, Southampton SO15 8TL, UK
1 shared publication
Latest Publications
- Open Access
- 20 December 2018
- Published by Springer Nature in BMC Chemistry
- Vol. 12 (1) , 1-16
Analysis of coumarin and angelica lactones in smokeless tobacco products
Differences in health risks between different styles of smokeless tobacco products (STPs) have prompted interest in their relative levels of toxic chemicals. We report here the development of methods for the analysis of STPs for coumarin and for α-angelica lactone (α-AL), both of which have been included in various published lists of tobacco toxicants. We have also determined the concentrations of these lactones in commercial STPs from the US and Sweden, representing 80–90% of the 2010 market share for all the major STP categories in these two countries: 65 products (plus two reference products) for coumarin and 66 commercial products for α-AL. For coumarin, methanol extracts of the STPs were analysed by HPLC/MS/MS. The lower limit of quantification (LOQ) and limit of detection (LOD) were, respectively, 100 and 30 ng coumarin/g of STP on a wet weight basis (WWB). Alpha-AL was determined via direct headspace GC/MS. The LOQ and LOD were 65 and 30 ng/g WWB respectively. Coumarin was detected In 3/33 Swedish snus, 5/13 US chewing tobaccos, 16/16 moist snuffs and 5/6 dry snuffs. Concentrations in those samples with quantifiable coumarin contents ranged from 186 to 1656 ng/g WWB. Concentrations of coumarin measured in this study were consistent with levels naturally found in tobacco. None of the STPs analysed would significantly contribute to coumarin exposure in consumers compared with dietary sources, and estimated exposure levels were 1000× lower than the European Food Safety Authority Tolerable Daily Intake. Hence the relevance of coumarin to the toxicity of STPs and its inclusion in the FDA’s list of harmful and potentially harmful compounds list is questionable. Measurements of α-AL in these STPs found that the majority did not have quantifiable contents, however, for three STPs concentrations of α-AL were above the LOQ (116–140 ng/g WWB) and for four other STPs concentrations of α-AL could be estimated between the LOD and LOQ. Beta-angelica lactone was tentatively identified in three of the STPs but the levels could not be reliably quantified. The levels of α-AL in tobacco products are reported here for the first time, but the relevance of α-AL to the toxicity of STPs is also highly questionable given that it has GRAS status as a permitted food additive.
- 20 December 2018
- Published by Springer Nature in BMC Chemistry
- Vol. 12 (1) , 1-16
Open AccessAnalysis of coumarin and angelica lactones in smokeless tobacco products
Differences in health risks between different styles of smokeless tobacco products (STPs) have prompted interest in their relative levels of toxic chemicals. We report here the development of methods for the analysis of STPs for coumarin and for α-angelica lactone (α-AL), both of which have been included in various published lists of tobacco toxicants. We have also determined the concentrations of these lactones in commercial STPs from the US and Sweden, representing 80–90% of the 2010 market share for all the major STP categories in these two countries: 65 products (plus two reference products) for coumarin and 66 commercial products for α-AL. For coumarin, methanol extracts of the STPs were analysed by HPLC/MS/MS. The lower limit of quantification (LOQ) and limit of detection (LOD) were, respectively, 100 and 30 ng coumarin/g of STP on a wet weight basis (WWB). Alpha-AL was determined via direct headspace GC/MS. The LOQ and LOD were 65 and 30 ng/g WWB respectively. Coumarin was detected In 3/33 Swedish snus, 5/13 US chewing tobaccos, 16/16 moist snuffs and 5/6 dry snuffs. Concentrations in those samples with quantifiable coumarin contents ranged from 186 to 1656 ng/g WWB. Concentrations of coumarin measured in this study were consistent with levels naturally found in tobacco. None of the STPs analysed would significantly contribute to coumarin exposure in consumers compared with dietary sources, and estimated exposure levels were 1000× lower than the European Food Safety Authority Tolerable Daily Intake. Hence the relevance of coumarin to the toxicity of STPs and its inclusion in the FDA’s list of harmful and potentially harmful compounds list is questionable. Measurements of α-AL in these STPs found that the majority did not have quantifiable contents, however, for three STPs concentrations of α-AL were above the LOQ (116–140 ng/g WWB) and for four other STPs concentrations of α-AL could be estimated between the LOD and LOQ. Beta-angelica lactone was tentatively identified in three of the STPs but the levels could not be reliably quantified. The levels of α-AL in tobacco products are reported here for the first time, but the relevance of α-AL to the toxicity of STPs is also highly questionable given that it has GRAS status as a permitted food additive.
- Open Access
- 16 March 2015
- Published by Springer Nature in BMC Chemistry
- Vol. 9 (1) , 13
Analysis of hydrazine in smokeless tobacco products by gas chromatography–mass spectrometry
Due to the lower health risks associated with the use of certain categories of smokeless tobacco products (STPs) such as Swedish snus, there is interest in the comparative levels of toxic chemical constituents in different types of STPs. A method has been developed and validated for the analysis of hydrazine in STPs. Seventy four commercial STPs from the US and Sweden, representing 80-90% of the 2010 market share for all the major STP categories in these two countries, as well as three reference STPs, were analysed for hydrazine. Aqueous extracts of the STPs were treated with excess pentafluorobenzaldehyde (PFB), which reacted with hydrazine in solution to form decafluorobenzaldehyde azine (DFBA). DFBA was partitioned into hexane and then quantified by gas chromatography–mass spectrometry (GC–MS). The method was validated using five different types of STP, was linear in the range 8–170 ng/mL, and had limits of quantification (LOQ) from 26–53 ng of hydrazine per g of STP (as sold). The method was applied to the analysis of 74 contemporary STPs commercially available in the United States and Sweden, none of which were found to contain hydrazine above the LOQ or LOD. Trace levels of compounds showing chromatographic and mass spectral features consistent with hydrazine were identified at very low levels (sub-limit of detection, <10 ng/g) in the chromatograms of less than half of the 74 STPs examined; in contrast, for 40 of the STPs no evidence for the presence of hydrazine was observed. Where present, the levels of compounds consistent with hydrazine were estimated to be at least an order of magnitude lower than the only previous study to have quantified hydrazine in tobacco. Our results show that hydrazine is not a prevalent constituent of STPs, and when present is not quantifiable using currently available analytical methodology.
- 16 March 2015
- Published by Springer Nature in BMC Chemistry
- Vol. 9 (1) , 13
Open AccessAnalysis of hydrazine in smokeless tobacco products by gas chromatography–mass spectrometry
Due to the lower health risks associated with the use of certain categories of smokeless tobacco products (STPs) such as Swedish snus, there is interest in the comparative levels of toxic chemical constituents in different types of STPs. A method has been developed and validated for the analysis of hydrazine in STPs. Seventy four commercial STPs from the US and Sweden, representing 80-90% of the 2010 market share for all the major STP categories in these two countries, as well as three reference STPs, were analysed for hydrazine. Aqueous extracts of the STPs were treated with excess pentafluorobenzaldehyde (PFB), which reacted with hydrazine in solution to form decafluorobenzaldehyde azine (DFBA). DFBA was partitioned into hexane and then quantified by gas chromatography–mass spectrometry (GC–MS). The method was validated using five different types of STP, was linear in the range 8–170 ng/mL, and had limits of quantification (LOQ) from 26–53 ng of hydrazine per g of STP (as sold). The method was applied to the analysis of 74 contemporary STPs commercially available in the United States and Sweden, none of which were found to contain hydrazine above the LOQ or LOD. Trace levels of compounds showing chromatographic and mass spectral features consistent with hydrazine were identified at very low levels (sub-limit of detection, <10 ng/g) in the chromatograms of less than half of the 74 STPs examined; in contrast, for 40 of the STPs no evidence for the presence of hydrazine was observed. Where present, the levels of compounds consistent with hydrazine were estimated to be at least an order of magnitude lower than the only previous study to have quantified hydrazine in tobacco. Our results show that hydrazine is not a prevalent constituent of STPs, and when present is not quantifiable using currently available analytical methodology.
- Open Access
- 7 January 2015
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 7 (4) , 1590-1599
A validated method to measure benzo[a]pyrene concentrations in tobacco by high-performance liquid chromatography-fluorescence detection
This publication describes a validated method suitable for the quantification of Benzo[a]Pyrene (B[a]P) in tobacco blend and smokeless tobacco products by High-Performance Liquid Chromatography-Fluorescence Detection (HPLC-FLD). Samples were hydrated and extracted with a mixture of hexane and acetone. For the quantification of levels of B[a]P the sample extracts were subjected to adsorption chromatography using base-modified silica to remove co-extracted substances. The concentrated final extract was re-dissolved in acetonitrile and analysed by HPLC with fluorescence detection (FLD). B[a]P and the internal standard, deuterated B[a]P (D12-B[a]P) were resolved chromatographically. The method was validated and determined to be fit for purpose for the quantification of B[a]P in tobacco from 3R4F Kentucky reference cigarettes, a flue-cured Virginia cigarette tobacco blend containing 10% air-cured Burley tobacco, and a Tanzanian dark fire-cured cigarette blend. The method was also validated for smokeless tobacco products including commercially available dry snuff, soft pellet tobacco and pouched snus products over the concentration range of 0.38 ng g−1 to 150 ng g−1, based on extraction of a 0.5–2 g aliquot of sample. The measurement uncertainty at a confidence interval of approximately 95% was estimated from data generated by three analysts using two instruments on three separate occasions using matrix (pouched snus) fortification experiments. The expanded uncertainty of the method was ±21.3% of the mean B[a]P concentration.
- 7 January 2015
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 7 (4) , 1590-1599
Open AccessA validated method to measure benzo[a]pyrene concentrations in tobacco by high-performance liquid chromatography-fluorescence detection
This publication describes a validated method suitable for the quantification of Benzo[a]Pyrene (B[a]P) in tobacco blend and smokeless tobacco products by High-Performance Liquid Chromatography-Fluorescence Detection (HPLC-FLD). Samples were hydrated and extracted with a mixture of hexane and acetone. For the quantification of levels of B[a]P the sample extracts were subjected to adsorption chromatography using base-modified silica to remove co-extracted substances. The concentrated final extract was re-dissolved in acetonitrile and analysed by HPLC with fluorescence detection (FLD). B[a]P and the internal standard, deuterated B[a]P (D12-B[a]P) were resolved chromatographically. The method was validated and determined to be fit for purpose for the quantification of B[a]P in tobacco from 3R4F Kentucky reference cigarettes, a flue-cured Virginia cigarette tobacco blend containing 10% air-cured Burley tobacco, and a Tanzanian dark fire-cured cigarette blend. The method was also validated for smokeless tobacco products including commercially available dry snuff, soft pellet tobacco and pouched snus products over the concentration range of 0.38 ng g−1 to 150 ng g−1, based on extraction of a 0.5–2 g aliquot of sample. The measurement uncertainty at a confidence interval of approximately 95% was estimated from data generated by three analysts using two instruments on three separate occasions using matrix (pouched snus) fortification experiments. The expanded uncertainty of the method was ±21.3% of the mean B[a]P concentration.