S. Reinhardt
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
S. Reinhardt has a total of 59 co-authors. Here are the top co-authors by number of shared publications:
W. Assmann
8 shared publicationsK. Parodi
4 shared publications- Jan Jakob Wilkens
Technical University of Munich (TUM)
3 shared publications M. Hillbrand
Rinecker Proton Therapy Center, Munich, Germany
3 shared publications- Günther Dollinger
Institute for Applied Physics and Measurement Technology, University of the Bundeswehr Munich, 85579 Munich, Germany
2 shared publications K Parodi
Department of Medical Physics, Ludwig‐Maximilians University Munich, Garching, DE
2 shared publications
Latest Publications
- Open Access
- 1 February 2016
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 118, S66-S67
Range Verification with Ionoacoustics: simulations and measurements at a clinical proton synchro-cyclotron
- 1 February 2016
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 118, S66-S67
Open AccessRange Verification with Ionoacoustics: simulations and measurements at a clinical proton synchro-cyclotron
- 29 June 2015
- Published by Wiley in Medical Physics
- Vol. 42 (6Part20) , 3458
SU‐E‐T‐533: LET Dependence Correction of Radiochromic Films for Application in Low Energy Proton Irradiation
- 29 June 2015
- Published by Wiley in Medical Physics
- Vol. 42 (6Part20) , 3458
SU‐E‐T‐533: LET Dependence Correction of Radiochromic Films for Application in Low Energy Proton Irradiation
- 9 January 2015
- Published by Springer Nature in Radiation and Environmental Biophysics
- Vol. 54 (1) , 71-79
Investigation of EBT2 and EBT3 films for proton dosimetry in the 4–20 MeV energy range
Radiochromic films such as Gafchromic EBT2 or EBT3 films are widely used for dose determination in radiation therapy because they offer a superior spatial resolution compared to any other digital dosimetric 2D detector array. The possibility to detect steep dose gradients is not only attractive for intensity-modulated radiation therapy with photons but also for intensity-modulated proton therapy. Their characteristic dose rate-independent response makes radiochromic films also attractive for dose determination in cell irradiation experiments using laser-driven ion accelerators, which are currently being investigated as future medical ion accelerators. However, when using these films in ion beams, the energy-dependent dose response in the vicinity of the Bragg peak has to be considered. In this work, the response of these films for low-energy protons is investigated. To allow for reproducible and background-free irradiation conditions, the films were exposed to mono-energetic protons from an electrostatic accelerator, in the 4–20 MeV energy range. For comparison, irradiation with clinical photons was also performed. It turned out that in general, EBT2 and EBT3 films show a comparable performance. For example, dose–response curves for photons and protons with energies as low as 11 MeV show almost no differences. However, corrections are required for proton energies below 11 MeV. Care has to be taken when correction factors are related to an average LET from depth–dose measurements, because only the dose-averaged LET yields similar results as obtained in mono-energetic measurements.
- 9 January 2015
- Published by Springer Nature in Radiation and Environmental Biophysics
- Vol. 54 (1) , 71-79
Investigation of EBT2 and EBT3 films for proton dosimetry in the 4–20 MeV energy range
Radiochromic films such as Gafchromic EBT2 or EBT3 films are widely used for dose determination in radiation therapy because they offer a superior spatial resolution compared to any other digital dosimetric 2D detector array. The possibility to detect steep dose gradients is not only attractive for intensity-modulated radiation therapy with photons but also for intensity-modulated proton therapy. Their characteristic dose rate-independent response makes radiochromic films also attractive for dose determination in cell irradiation experiments using laser-driven ion accelerators, which are currently being investigated as future medical ion accelerators. However, when using these films in ion beams, the energy-dependent dose response in the vicinity of the Bragg peak has to be considered. In this work, the response of these films for low-energy protons is investigated. To allow for reproducible and background-free irradiation conditions, the films were exposed to mono-energetic protons from an electrostatic accelerator, in the 4–20 MeV energy range. For comparison, irradiation with clinical photons was also performed. It turned out that in general, EBT2 and EBT3 films show a comparable performance. For example, dose–response curves for photons and protons with energies as low as 11 MeV show almost no differences. However, corrections are required for proton energies below 11 MeV. Care has to be taken when correction factors are related to an average LET from depth–dose measurements, because only the dose-averaged LET yields similar results as obtained in mono-energetic measurements.
- 1 February 2014
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 110, S73
150: Experimental characterization of acoustic detection and imaging for Bragg peak localization in proton therapy
- 1 February 2014
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 110, S73
150: Experimental characterization of acoustic detection and imaging for Bragg peak localization in proton therapy
- 6 June 2013
- Published by Wiley in Medical Physics
- Vol. 40 (6Part11) , 215
SU-E-T-52: Evaluation of EBT2 and EBT3 Films for Dosimetry in Laser-Driven Ion Accelerators
- 6 June 2013
- Published by Wiley in Medical Physics
- Vol. 40 (6Part11) , 215
SU-E-T-52: Evaluation of EBT2 and EBT3 Films for Dosimetry in Laser-Driven Ion Accelerators
- Open Access
- 1 March 2013
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 106, S291
PO-0764: Evaluation of EBT3 films for use in clinical photon and proton beams
- 1 March 2013
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 106, S291
Open AccessPO-0764: Evaluation of EBT3 films for use in clinical photon and proton beams
- Open Access
- 1 March 2013
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 106, S217-S218
PD-0568: Investigation of the optimal design of IMRT QA tests with regard to the properties of the MLC and the measurement device
- 1 March 2013
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 106, S217-S218
Open AccessPD-0568: Investigation of the optimal design of IMRT QA tests with regard to the properties of the MLC and the measurement device
- 1 August 2012
- Published by Wiley in Medical Physics
- Vol. 39 (8) , 5257-5262
Comparison of Gafchromic EBT2 and EBT3 films for clinical photon and proton beams
Purpose: Dose verification in highly conformal radiation therapy such as IMRT or proton therapy can benefit from the high spatial resolution offered by radio‐chromic films such as Gafchromic EBT or EBT2. Recently, a new generation of these films, EBT3, has become available. The composition and thickness of the sensitive layer are the same as for the previous EBT2 films. The most important change is the symmetric layer configuration to eliminate side orientation dependence, which is reported for EBT2 films.Methods: The general film characteristics such as sensitivity to read‐out orientation and postexposure darkening evolution of the new EBT3 film are evaluated. Film response has been investigated in clinical photon and proton beams and compared to former EBT2 films. Quenching effects in the proton Bragg peak region have been studied for both, EBT2 and EBT3 films.Results: The general performance of EBT3 is comparable to EBT2, and the orientation dependence with respect to film side is completely eliminated in EBT3 films. Response differences of EBT2 and EBT3 films are of the same order of magnitude as batch‐to‐batch variations observed for EBT2 films. No significant difference has been found for both generations of EBT films between photon and proton exposure. Depth dose measurements of EBT2 and EBT3 show an excellent agreement, though underestimating dose by up to 20% in the Bragg peak region.Conclusions: The symmetric configuration of EBT3 presents a major improvement for film handling. EBT3 has similar dosimetric performance as its precursor EBT2 and can, thus, be applied to dose verification in IMRT in the same way. For dose verification in proton therapy the underresponse in the Bragg peak region has to be taken into account.
- 1 August 2012
- Published by Wiley in Medical Physics
- Vol. 39 (8) , 5257-5262
Comparison of Gafchromic EBT2 and EBT3 films for clinical photon and proton beams
Purpose: Dose verification in highly conformal radiation therapy such as IMRT or proton therapy can benefit from the high spatial resolution offered by radio‐chromic films such as Gafchromic EBT or EBT2. Recently, a new generation of these films, EBT3, has become available. The composition and thickness of the sensitive layer are the same as for the previous EBT2 films. The most important change is the symmetric layer configuration to eliminate side orientation dependence, which is reported for EBT2 films.Methods: The general film characteristics such as sensitivity to read‐out orientation and postexposure darkening evolution of the new EBT3 film are evaluated. Film response has been investigated in clinical photon and proton beams and compared to former EBT2 films. Quenching effects in the proton Bragg peak region have been studied for both, EBT2 and EBT3 films.Results: The general performance of EBT3 is comparable to EBT2, and the orientation dependence with respect to film side is completely eliminated in EBT3 films. Response differences of EBT2 and EBT3 films are of the same order of magnitude as batch‐to‐batch variations observed for EBT2 films. No significant difference has been found for both generations of EBT films between photon and proton exposure. Depth dose measurements of EBT2 and EBT3 show an excellent agreement, though underestimating dose by up to 20% in the Bragg peak region.Conclusions: The symmetric configuration of EBT3 presents a major improvement for film handling. EBT3 has similar dosimetric performance as its precursor EBT2 and can, thus, be applied to dose verification in IMRT in the same way. For dose verification in proton therapy the underresponse in the Bragg peak region has to be taken into account.
- 1 March 2012
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 102, S21-S22
62 TEST OF DIFFERENT PIXEL DETECTORS FOR LASER-DRIVEN ACCELERATED PARTICLE BEAMS
- 1 March 2012
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 102, S21-S22
62 TEST OF DIFFERENT PIXEL DETECTORS FOR LASER-DRIVEN ACCELERATED PARTICLE BEAMS
- 1 March 2012
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 102, S31
83 SINGLE SHOT HIGH DOSE CELL IRRADIATIONS WITH LASER-DRIVEN PROTONS
- 1 March 2012
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 102, S31
83 SINGLE SHOT HIGH DOSE CELL IRRADIATIONS WITH LASER-DRIVEN PROTONS