Werner De Gersem
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Werner De Gersem has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
- Tom Vercauteren
Department of Radiotherapy, Ghent University, Ghent, Belgium
4 shared publications - Bruno Speleers
Department of Human Structure and Repair, Faculty of Medicine and Health Sciences, Ghent University, Ghent, Belgium
3 shared publications - Liv Veldeman
Ghent University Hospital, Department of Radiation Oncology, Ghent, Belgium
3 shared publications - Katrien Vandecasteele
Cancer Research Institute Ghent (CRIG), 9000 Ghent, Belgium
2 shared publications - Thomas Mulliez
Department of Radiotherapy, Ghent University Hospital, De Pintelaan 185, 9000, Ghent, Belgium.
2 shared publications - Wilfried De Neve
Department of Human structure and repair, Ghent University, Belgium; Department of Radiation Oncology, Ghent University Hospital, Belgium
2 shared publications
Latest Publications
- Open Access
- 12 May 2024
- Published by Elsevier in Clinical and Translational Radiation Oncology
- Vol. 47, 100793
Exclusion of non-Involved uterus from the target volume (EXIT-trial): An individualized treatment for locally advanced cervical cancer using modern radiotherapy and imaging techniques followed by completion surgery
- 12 May 2024
- Published by Elsevier in Clinical and Translational Radiation Oncology
- Vol. 47, 100793
Open AccessExclusion of non-Involved uterus from the target volume (EXIT-trial): An individualized treatment for locally advanced cervical cancer using modern radiotherapy and imaging techniques followed by completion surgery
- Open Access
- 2 April 2016
- Published by Springer Nature in Radiation Oncology
- Vol. 11 (1) , 1-9
Intensity modulated arc therapy implementation in a three phase adaptive 18F-FDG-PET voxel intensity-based planning strategy for head-and-neck cancer
This study investigates the implementation of a new intensity modulated arc therapy (IMAT) class solution in comparison to a 6-static beam step-and-shoot intensity modulated radiotherapy (s-IMRT) for three-phase adaptive 18F-FDG-PET-voxel-based dose-painting-by-numbers (DPBN) for head-and-neck cancer. We developed 18F-FDG-PET-voxel intensity-based IMAT employing multiple arcs and compared it to clinically used s-IMRT DPBN. Three IMAT plans using 18F-FDG-PET/CT acquired before treatment (phase I), after 8 fractions (phase II) and CT acquired after 18 fractions (phase III) were generated for each of 10 patients treated with 3 s-IMRT plans based on the same image sets. Based on deformable image registration (ABAS, version 0.41, Elekta CMS Software, Maryland Heights, MO), doses of the 3 plans were summed on the pretreatment CT using validated in-house developed software. Dosimetric indices in targets and organs-at-risk (OARs), biologic conformity of treatment plans set at ≤5 %, treatment quality and efficiency were compared between IMAT and s-IMRT for the whole group and for individual patients. Doses to most organs-at-risk (OARs) were significantly better in IMAT plans, while target levels were similar for both types of plans. On average, IMAT ipsilateral and contralateral parotid mean doses were 14.0 % (p = 0.001) and 12.7 % (p < 0.001) lower, respectively. Pharyngeal constrictors D50% levels were similar or reduced with up to 54.9 % for IMAT compared to s-IMRT for individual patient cases. IMAT significantly improved biologic conformity by 2.1 % for treatment phases I and II. 3D phantom measurements reported an agreement of ≥95 % for 3 % and 3 mm criteria for both treatment modalities. IMAT delivery time was significantly shortened on average by 41.1 %. IMAT implementation significantly improved the biologic conformity as compared to s-IMRT in adaptive dose-escalated DPBN treatments. The better OAR sparing and faster delivery highly improved the treatment efficiency.
- 2 April 2016
- Published by Springer Nature in Radiation Oncology
- Vol. 11 (1) , 1-9
Open AccessIntensity modulated arc therapy implementation in a three phase adaptive 18F-FDG-PET voxel intensity-based planning strategy for head-and-neck cancer
This study investigates the implementation of a new intensity modulated arc therapy (IMAT) class solution in comparison to a 6-static beam step-and-shoot intensity modulated radiotherapy (s-IMRT) for three-phase adaptive 18F-FDG-PET-voxel-based dose-painting-by-numbers (DPBN) for head-and-neck cancer. We developed 18F-FDG-PET-voxel intensity-based IMAT employing multiple arcs and compared it to clinically used s-IMRT DPBN. Three IMAT plans using 18F-FDG-PET/CT acquired before treatment (phase I), after 8 fractions (phase II) and CT acquired after 18 fractions (phase III) were generated for each of 10 patients treated with 3 s-IMRT plans based on the same image sets. Based on deformable image registration (ABAS, version 0.41, Elekta CMS Software, Maryland Heights, MO), doses of the 3 plans were summed on the pretreatment CT using validated in-house developed software. Dosimetric indices in targets and organs-at-risk (OARs), biologic conformity of treatment plans set at ≤5 %, treatment quality and efficiency were compared between IMAT and s-IMRT for the whole group and for individual patients. Doses to most organs-at-risk (OARs) were significantly better in IMAT plans, while target levels were similar for both types of plans. On average, IMAT ipsilateral and contralateral parotid mean doses were 14.0 % (p = 0.001) and 12.7 % (p < 0.001) lower, respectively. Pharyngeal constrictors D50% levels were similar or reduced with up to 54.9 % for IMAT compared to s-IMRT for individual patient cases. IMAT significantly improved biologic conformity by 2.1 % for treatment phases I and II. 3D phantom measurements reported an agreement of ≥95 % for 3 % and 3 mm criteria for both treatment modalities. IMAT delivery time was significantly shortened on average by 41.1 %. IMAT implementation significantly improved the biologic conformity as compared to s-IMRT in adaptive dose-escalated DPBN treatments. The better OAR sparing and faster delivery highly improved the treatment efficiency.
- Open Access
- 9 January 2015
- Published by Springer Nature in Radiation Oncology
- Vol. 10 (1) , 9
Reproducibility of deep inspiration breath hold for prone left-sided whole breast irradiation
Investigating reproducibility and instability of deep inspiration breath hold (DIBH) in the prone position to reduce heart dose for left-sided whole breast irradiation. Thirty patients were included and underwent 2 prone DIBH CT-scans during simulation. Overlap indices were calculated for the ipsilateral breast, heart and lungs to evaluate the anatomical reproducibility of the DIBH maneuver. The breathing motion of 21 patients treated with prone DIBH were registered using magnetic probes. These breathing curves were investigated to gain data on intra-fraction reproducibility and instability of the different DIBH cycles during treatment. Overlap index was 0.98 for the ipsilateral breast and 0.96 for heart and both lungs between the 2 prone DIBH-scans. The magnetic sensors reported population amplitudes of 2.8 ± 1.3 mm for shallow breathing and 11.7 ± 4.7 mm for DIBH, an intra-fraction standard deviation of 1.0 ± 0.4 mm for DIBH, an intra-breath hold instability of 1.0 ± 0.6 mm and a treatment time of 300 ± 69 s. Prone DIBH can be accurately clinically implemented with acceptable reproducibility and instability.
- 9 January 2015
- Published by Springer Nature in Radiation Oncology
- Vol. 10 (1) , 9
Open AccessReproducibility of deep inspiration breath hold for prone left-sided whole breast irradiation
Investigating reproducibility and instability of deep inspiration breath hold (DIBH) in the prone position to reduce heart dose for left-sided whole breast irradiation. Thirty patients were included and underwent 2 prone DIBH CT-scans during simulation. Overlap indices were calculated for the ipsilateral breast, heart and lungs to evaluate the anatomical reproducibility of the DIBH maneuver. The breathing motion of 21 patients treated with prone DIBH were registered using magnetic probes. These breathing curves were investigated to gain data on intra-fraction reproducibility and instability of the different DIBH cycles during treatment. Overlap index was 0.98 for the ipsilateral breast and 0.96 for heart and both lungs between the 2 prone DIBH-scans. The magnetic sensors reported population amplitudes of 2.8 ± 1.3 mm for shallow breathing and 11.7 ± 4.7 mm for DIBH, an intra-fraction standard deviation of 1.0 ± 0.4 mm for DIBH, an intra-breath hold instability of 1.0 ± 0.6 mm and a treatment time of 300 ± 69 s. Prone DIBH can be accurately clinically implemented with acceptable reproducibility and instability.
- Open Access
- 24 June 2013
- Published by Springer Nature in Radiation Oncology
- Vol. 8 (1) , 151
Whole breast radiotherapy in prone and supine position: is there a place for multi-beam IMRT?
Early stage breast cancer patients are long-term survivors and finding techniques that may lower acute and late radiotherapy-induced toxicity is crucial. We compared dosimetry of wedged tangential fields (W-TF), tangential field intensity-modulated radiotherapy (TF-IMRT) and multi-beam IMRT (MB-IMRT) in prone and supine positions for whole-breast irradiation (WBI).
- 24 June 2013
- Published by Springer Nature in Radiation Oncology
- Vol. 8 (1) , 151
Open AccessWhole breast radiotherapy in prone and supine position: is there a place for multi-beam IMRT?
Early stage breast cancer patients are long-term survivors and finding techniques that may lower acute and late radiotherapy-induced toxicity is crucial. We compared dosimetry of wedged tangential fields (W-TF), tangential field intensity-modulated radiotherapy (TF-IMRT) and multi-beam IMRT (MB-IMRT) in prone and supine positions for whole-breast irradiation (WBI).