Thierry Bourguignon
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Thierry Bourguignon has a total of 45 co-authors. Here are the top co-authors by number of shared publications:
Alain Mirza
Department of Cardiac Surgery , Tours University Hospital , Tours , France
5 shared publicationsClaudia Loardi
Department of Cardiothoracic Surgery, Trousseau University Hospital, Tours, France
5 shared publicationsMichel Aupart
Department of Cardiothoracic Surgery, Trousseau University Hospital, Tours, France
5 shared publicationsMichel Marchand
Department of Cardiac Surgery , Tours University Hospital , Tours , France
5 shared publicationsPascal Candolfi
Department of Biostatistics, Edwards Lifesciences, Nyon, Switzerland
5 shared publicationsAnne-Lorraine Bouquiaux-Stablo
Department of Cardiac Surgery, Tours University Hospital, France
2 shared publications
Latest Publications
- 1 September 2019
- Published by Elsevier in The Journal of Thoracic and Cardiovascular Surgery
- Vol. 158 (3) , 780-790.e1
Stimulation of murine P2Y11-like purinoreceptor protects against hypoxia/reoxygenation injury and decreases heart graft rejection lesions
- 1 September 2019
- Published by Elsevier in The Journal of Thoracic and Cardiovascular Surgery
- Vol. 158 (3) , 780-790.e1
Stimulation of murine P2Y11-like purinoreceptor protects against hypoxia/reoxygenation injury and decreases heart graft rejection lesions
- 4 April 2018
- Published by Georg Thieme Verlag KG in Thrombosis and Haemostasis
- Vol. 118 (05) , 945-947
Risk of Thromboembolic Events without Oral Anticoagulation at 90 Days after Surgical Aortic Valve Replacement with a Bioprosthesis
Thromboembolism, including systemic emboli and prosthetic valve thrombosis, is among the most dreaded complications after aortic valve replacement (AVR). However, in contrast to the lifelong necessity of oral anticoagulation (OAC) with mechanical valves, the optimal antithrombotic regimen and duration of treatment after implantation of a bioprosthesis remain controversial. Despite low long-term thromboembolic risk, it has been anticipated that patients with bioprosthetic valves are at moderate risk for thromboembolic complications in the first 3 months after surgery, until the sewing ring is fully endothelialized.[1] [2] [3] For patients at high risk for thromboembolic events (atrial fibrillation, venous thromboembolism, hypercoagulable state or severely impaired left ventricular function), current guidelines recommend OAC.[4] [5] However, the optimal antithrombotic therapy is still debated for the majority of patients after bioprosthetic AVR. This is reflected in the most recent North American and European guidelines, which recommend low dose aspirin (evidence level IIa), or warfarin therapy (evidence level IIa and IIb, respectively) for 3 months after surgery.[4] [5] Of note, these guidelines are supported by weak evidence. The initial support for post-operative OAC came from Heras et al in 1995, reporting that OAC was associated with lower thromboembolic risk after implantation of a bioprosthesis. However, this observational study examined early generation bioprosthetic valves implanted in the 1970s and included both aortic and mitral valve implantations.[2] To date, only two randomized trials have compared anticoagulation versus antiplatelet treatment after bioprosthetic AVR.[6] [7] Both trials did not demonstrate superiority of anticoagulation over antiplatelet treatment for thromboprophylaxis. None of them focused on patients with no condition associated with high-risk of thromboembolism. As a consequence, there remains great variability in the current clinical practice. The ACTION Registry including 48 European centres reported that after bioprosthetic AVR, 43% of centres prescribe anticoagulation with warfarin only, 33% with aspirin only, 20% with both aspirin and warfarin and no antithrombotic therapy at all in 4% of the centres.[8] In patients undergoing surgical AVR with a bioprosthesis and no condition with a high-risk of thromboembolism, we compared the 3-month outcomes with a post-operative management with no OAC and with or without aspirin 75 mg once daily. From 1984 to 2011, a total of 2,981 consecutive patients undergoing bioprosthetic AVR at our institution were identified. They all received the same model of bovine pericardial bioprosthesis (PERIMOUNT valve, Edwards Lifesciences, Irvine, California, United States). Exclusion criteria were: associated surgery on another valve; history of atrial fibrillation, thromboembolism, venous thrombosis and/or pulmonary embolus; and left ventricular ejection fraction inferior to 30%. Patients with prior use of anticoagulants and high risk of bleeding like history of cerebral bleeding were also excluded. Finally, patients who developed post-operative atrial fibrillation before hospital discharge were also excluded from the study. At the time of discharge, 2,282 patients met the inclusion criteria (n = 699 exclusions). For all these patients with no condition associated with a high thromboembolic risk, a strategy with no post-operative OAC was systematically chosen. Low-molecular weight heparin 4,000 IU was administered for 10 days post-operatively. The administration of aspirin was at the discretion of the clinician and was started on day 2 after operation. Group A (n = 1,194 patients) received no post-operative OAC and no aspirin, while group B (n = 1,088 patients) received no OAC but a low-dose aspirin (75 mg once daily) during the first 3 months. Hospital charts of all patients were reviewed for in-hospital events. For 90-day follow-up, clinical questionnaires were mailed to patients and those not responding were contacted by phone. Information concerning post-operative treatment, bleeding and thromboembolic events were collected. The 90-day-follow-up was 100% complete. Definition of events followed guidelines for reporting morbidity after cardiac intervention.[9] At baseline, the only significant difference between the two groups was a higher prevalence of coronary artery disease and coronary artery bypass graft in the group treated with aspirin (26.5% vs. 15.1%; p < 0.01) ([Table 1]). There was no significant difference concerning operative mortality or the mean hospital stay, around 7 days. At 3 months, thromboembolic and bleeding events were rare and we report no case of valve thrombosis. More precisely, 27 thromboembolic events were reported at 3 months: 15 strokes (4 leading to death), 7 transient ischaemic attack and 5 non-cerebral thromboembolic events. In multivariate analysis, use of aspirin was not associated with a lower risk of thromboembolism (odds ratio [OR] = 0.96; p = 0.91). Interestingly, 78% (n = 21) of thromboembolic events occurred in the first week and only 6 events were described after hospital discharge. Five bleeding events were reported: 4 of them occurred during the first month and 2 led to death. Localization of bleeding was respiratory, orthopaedic, gastrointestinal or gynaecological. In multivariate analysis, use of aspirin was not associated with a higher risk of bleeding (OR = 1.03; p = 0.88). All authors confirm they had full access to data and contributed to drafting of the article.
- 4 April 2018
- Published by Georg Thieme Verlag KG in Thrombosis and Haemostasis
- Vol. 118 (05) , 945-947
Risk of Thromboembolic Events without Oral Anticoagulation at 90 Days after Surgical Aortic Valve Replacement with a Bioprosthesis
Thromboembolism, including systemic emboli and prosthetic valve thrombosis, is among the most dreaded complications after aortic valve replacement (AVR). However, in contrast to the lifelong necessity of oral anticoagulation (OAC) with mechanical valves, the optimal antithrombotic regimen and duration of treatment after implantation of a bioprosthesis remain controversial. Despite low long-term thromboembolic risk, it has been anticipated that patients with bioprosthetic valves are at moderate risk for thromboembolic complications in the first 3 months after surgery, until the sewing ring is fully endothelialized.[1] [2] [3] For patients at high risk for thromboembolic events (atrial fibrillation, venous thromboembolism, hypercoagulable state or severely impaired left ventricular function), current guidelines recommend OAC.[4] [5] However, the optimal antithrombotic therapy is still debated for the majority of patients after bioprosthetic AVR. This is reflected in the most recent North American and European guidelines, which recommend low dose aspirin (evidence level IIa), or warfarin therapy (evidence level IIa and IIb, respectively) for 3 months after surgery.[4] [5] Of note, these guidelines are supported by weak evidence. The initial support for post-operative OAC came from Heras et al in 1995, reporting that OAC was associated with lower thromboembolic risk after implantation of a bioprosthesis. However, this observational study examined early generation bioprosthetic valves implanted in the 1970s and included both aortic and mitral valve implantations.[2] To date, only two randomized trials have compared anticoagulation versus antiplatelet treatment after bioprosthetic AVR.[6] [7] Both trials did not demonstrate superiority of anticoagulation over antiplatelet treatment for thromboprophylaxis. None of them focused on patients with no condition associated with high-risk of thromboembolism. As a consequence, there remains great variability in the current clinical practice. The ACTION Registry including 48 European centres reported that after bioprosthetic AVR, 43% of centres prescribe anticoagulation with warfarin only, 33% with aspirin only, 20% with both aspirin and warfarin and no antithrombotic therapy at all in 4% of the centres.[8] In patients undergoing surgical AVR with a bioprosthesis and no condition with a high-risk of thromboembolism, we compared the 3-month outcomes with a post-operative management with no OAC and with or without aspirin 75 mg once daily. From 1984 to 2011, a total of 2,981 consecutive patients undergoing bioprosthetic AVR at our institution were identified. They all received the same model of bovine pericardial bioprosthesis (PERIMOUNT valve, Edwards Lifesciences, Irvine, California, United States). Exclusion criteria were: associated surgery on another valve; history of atrial fibrillation, thromboembolism, venous thrombosis and/or pulmonary embolus; and left ventricular ejection fraction inferior to 30%. Patients with prior use of anticoagulants and high risk of bleeding like history of cerebral bleeding were also excluded. Finally, patients who developed post-operative atrial fibrillation before hospital discharge were also excluded from the study. At the time of discharge, 2,282 patients met the inclusion criteria (n = 699 exclusions). For all these patients with no condition associated with a high thromboembolic risk, a strategy with no post-operative OAC was systematically chosen. Low-molecular weight heparin 4,000 IU was administered for 10 days post-operatively. The administration of aspirin was at the discretion of the clinician and was started on day 2 after operation. Group A (n = 1,194 patients) received no post-operative OAC and no aspirin, while group B (n = 1,088 patients) received no OAC but a low-dose aspirin (75 mg once daily) during the first 3 months. Hospital charts of all patients were reviewed for in-hospital events. For 90-day follow-up, clinical questionnaires were mailed to patients and those not responding were contacted by phone. Information concerning post-operative treatment, bleeding and thromboembolic events were collected. The 90-day-follow-up was 100% complete. Definition of events followed guidelines for reporting morbidity after cardiac intervention.[9] At baseline, the only significant difference between the two groups was a higher prevalence of coronary artery disease and coronary artery bypass graft in the group treated with aspirin (26.5% vs. 15.1%; p < 0.01) ([Table 1]). There was no significant difference concerning operative mortality or the mean hospital stay, around 7 days. At 3 months, thromboembolic and bleeding events were rare and we report no case of valve thrombosis. More precisely, 27 thromboembolic events were reported at 3 months: 15 strokes (4 leading to death), 7 transient ischaemic attack and 5 non-cerebral thromboembolic events. In multivariate analysis, use of aspirin was not associated with a lower risk of thromboembolism (odds ratio [OR] = 0.96; p = 0.91). Interestingly, 78% (n = 21) of thromboembolic events occurred in the first week and only 6 events were described after hospital discharge. Five bleeding events were reported: 4 of them occurred during the first month and 2 led to death. Localization of bleeding was respiratory, orthopaedic, gastrointestinal or gynaecological. In multivariate analysis, use of aspirin was not associated with a higher risk of bleeding (OR = 1.03; p = 0.88). All authors confirm they had full access to data and contributed to drafting of the article.
- 12 February 2018
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 54 (2) , 302-309
Bioprosthetic mitral valve replacement in patients aged 65 years or younger: long-term outcomes with the Carpentier–Edwards PERIMOUNT pericardial valve†
Mitral valve replacement using a bioprosthesis remains controversial in young patients because data on long-term outcomes are missing. This study evaluated the long-term results of the PERIMOUNT pericardial mitral bioprosthesis in patients aged 65 years or younger. From 1984 to 2010, 148 Carpentier–Edwards PERIMOUNT mitral bioprostheses were implanted in 148 patients aged 65 years or younger. Baseline clinical, perioperative and follow-up data were recorded prospectively. Structural valve deterioration (SVD) was defined by strict echocardiographic assessment. The mean follow-up period was 8.6 ± 5.5 years, for a total of 1269 valve-years. Operative mortality rate was 2.0%. Fifty-one late deaths occurred (linearized rate 4.0% per valve-year). Actuarial survival rates averaged 70 ± 4%, 53 ± 6% and 31 ± 7% after 10, 15 and 20 years of follow-up, respectively. Actuarial freedom from SVD at 10, 15 and 20 years was 78 ± 5%, 47 ± 7% and 19 ± 7%, respectively. Reoperation was associated with no operative mortality. Actuarial freedom from reoperation due to SVD at 10, 15 and 20 years was 82 ± 4%, 50 ± 6% and 25 ± 8%, respectively. Competing risk analysis demonstrated an actual risk of explantation secondary to SVD at 20 years of 44 ± 5%. Expected valve durability was 14.2 years for this age group. In the selected patients aged 65 years or younger undergoing mitral valve replacement with a pericardial bioprosthesis, the expected valve durability was 14.2 years. Reoperation for SVD was associated with a low risk of mortality.
- 12 February 2018
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 54 (2) , 302-309
Bioprosthetic mitral valve replacement in patients aged 65 years or younger: long-term outcomes with the Carpentier–Edwards PERIMOUNT pericardial valve†
Mitral valve replacement using a bioprosthesis remains controversial in young patients because data on long-term outcomes are missing. This study evaluated the long-term results of the PERIMOUNT pericardial mitral bioprosthesis in patients aged 65 years or younger. From 1984 to 2010, 148 Carpentier–Edwards PERIMOUNT mitral bioprostheses were implanted in 148 patients aged 65 years or younger. Baseline clinical, perioperative and follow-up data were recorded prospectively. Structural valve deterioration (SVD) was defined by strict echocardiographic assessment. The mean follow-up period was 8.6 ± 5.5 years, for a total of 1269 valve-years. Operative mortality rate was 2.0%. Fifty-one late deaths occurred (linearized rate 4.0% per valve-year). Actuarial survival rates averaged 70 ± 4%, 53 ± 6% and 31 ± 7% after 10, 15 and 20 years of follow-up, respectively. Actuarial freedom from SVD at 10, 15 and 20 years was 78 ± 5%, 47 ± 7% and 19 ± 7%, respectively. Reoperation was associated with no operative mortality. Actuarial freedom from reoperation due to SVD at 10, 15 and 20 years was 82 ± 4%, 50 ± 6% and 25 ± 8%, respectively. Competing risk analysis demonstrated an actual risk of explantation secondary to SVD at 20 years of 44 ± 5%. Expected valve durability was 14.2 years for this age group. In the selected patients aged 65 years or younger undergoing mitral valve replacement with a pericardial bioprosthesis, the expected valve durability was 14.2 years. Reoperation for SVD was associated with a low risk of mortality.
- Open Access
- 1 February 2018
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
- Vol. 20 (1) , 59-11
Cardiovascular magnetic resonance in heart transplant patients: diagnostic value of quantitative tissue markers: T2 mapping and extracellular volume fraction, for acute rejection diagnosis
- 1 February 2018
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
- Vol. 20 (1) , 59-11
Open AccessCardiovascular magnetic resonance in heart transplant patients: diagnostic value of quantitative tissue markers: T2 mapping and extracellular volume fraction, for acute rejection diagnosis
- Open Access
- 2 November 2015
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 49 (5) , 1462-1468
Very long-term outcomes of the Carpentier-Edwards Perimount aortic valve in patients aged 50–65 years
Aortic valve replacement (AVR) using a bioprosthesis remains controversial for patients aged 50–65 years. This cohort study reports the very long-term outcomes of AVR using Carpentier-Edwards Perimount pericardial bioprosthesis in this age group. From 1984 to 2008, 522 Carpentier-Edwards Perimount pericardial aortic bioprostheses were implanted in 516 patients aged 50–65 years (mean age, 60 ± 4 years; 19% female). Multiple valve replacements were excluded fro m our cohort. Baseline demographic, perioperative and follow-up data were recorded prospectively. Mean follow-up was 9 ± 6 years, for a total of 4428 valve-years. Follow-up was complete for 97% of patients included. Operative mortality rate was 2%. One hundred and forty-six late deaths occurred for a linearized rate of 3%/valve-year. Actuarial survival rates averaged 73 ± 2, 59 ± 3 and 35 ± 5% after 10, 15 and 20 years of follow-up, respectively. Mortality rate associated with reoperation was 2%. Actuarial freedom from reoperation rates due to structural valve deterioration (SVD) at 10, 15 and 20 years was respectively of 91 ± 2, 76 ± 3 and 50 ± 6%. Competing risk analysis demonstrated an actual risk of explantation secondary to SVD at 20 years of 30 ± 3%. Expected valve durability was 19 years for this age group. Age was not a significant risk factor for SVD in this middle-aged population. In patients aged 50–65 years undergoing AVR with the Carpentier-Edwards Perimount bioprosthesis, the expected valve durability was 19 years. Age was not a significant risk factor for SVD within this age group. Patient selection and attention to timing of reintervention may be determinants of long-term outcomes.
- 2 November 2015
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 49 (5) , 1462-1468
Open AccessVery long-term outcomes of the Carpentier-Edwards Perimount aortic valve in patients aged 50–65 years
Aortic valve replacement (AVR) using a bioprosthesis remains controversial for patients aged 50–65 years. This cohort study reports the very long-term outcomes of AVR using Carpentier-Edwards Perimount pericardial bioprosthesis in this age group. From 1984 to 2008, 522 Carpentier-Edwards Perimount pericardial aortic bioprostheses were implanted in 516 patients aged 50–65 years (mean age, 60 ± 4 years; 19% female). Multiple valve replacements were excluded fro m our cohort. Baseline demographic, perioperative and follow-up data were recorded prospectively. Mean follow-up was 9 ± 6 years, for a total of 4428 valve-years. Follow-up was complete for 97% of patients included. Operative mortality rate was 2%. One hundred and forty-six late deaths occurred for a linearized rate of 3%/valve-year. Actuarial survival rates averaged 73 ± 2, 59 ± 3 and 35 ± 5% after 10, 15 and 20 years of follow-up, respectively. Mortality rate associated with reoperation was 2%. Actuarial freedom from reoperation rates due to structural valve deterioration (SVD) at 10, 15 and 20 years was respectively of 91 ± 2, 76 ± 3 and 50 ± 6%. Competing risk analysis demonstrated an actual risk of explantation secondary to SVD at 20 years of 30 ± 3%. Expected valve durability was 19 years for this age group. Age was not a significant risk factor for SVD in this middle-aged population. In patients aged 50–65 years undergoing AVR with the Carpentier-Edwards Perimount bioprosthesis, the expected valve durability was 19 years. Age was not a significant risk factor for SVD within this age group. Patient selection and attention to timing of reintervention may be determinants of long-term outcomes.
- 1 September 2015
- Published by Elsevier in The Annals of Thoracic Surgery
- Vol. 100 (3) , 853-859
Very Long-Term Outcomes of the Carpentier-Edwards Perimount Aortic Valve in Patients Aged 60 or Younger
- 1 September 2015
- Published by Elsevier in The Annals of Thoracic Surgery
- Vol. 100 (3) , 853-859
Very Long-Term Outcomes of the Carpentier-Edwards Perimount Aortic Valve in Patients Aged 60 or Younger
- Top Cited Papers
- 1 March 2015
- Published by Elsevier in The Annals of Thoracic Surgery
- Vol. 99 (3) , 831-837
Very Long-Term Outcomes of the Carpentier-Edwards Perimount Valve in Aortic Position
- 1 March 2015
- Published by Elsevier in The Annals of Thoracic Surgery
- Vol. 99 (3) , 831-837
Top Cited PapersVery Long-Term Outcomes of the Carpentier-Edwards Perimount Valve in Aortic Position
- 1 November 2014
- Published by Elsevier in The Journal of Thoracic and Cardiovascular Surgery
- Vol. 148 (5) , 2004-2011.e1
Very late outcomes for mitral valve replacement with the Carpentier-Edwards pericardial bioprosthesis: 25-year follow-up of 450 implantations
- 1 November 2014
- Published by Elsevier in The Journal of Thoracic and Cardiovascular Surgery
- Vol. 148 (5) , 2004-2011.e1
Very late outcomes for mitral valve replacement with the Carpentier-Edwards pericardial bioprosthesis: 25-year follow-up of 450 implantations
- 1 November 2011
- Vol. 20 (6) , 673-80
Risk factors for valve-related complications after mechanical heart valve replacement in 505 patients with long-term follow up.
Currently, valve thrombosis, thromboembolic events and bleeding events account for 75% of all complications that occur after mechanical heart valve replacement. The study aim was to determine the main risk factors for valve-related complications in patients undergoing mechanical heart valve replacement. Data were available from the systematic follow up of patients who had received a CarboMedics bileaflet mechanical heart valve replacement at the authors' institution. Follow up examinations were conducted prospectively at two-year intervals, via questionnaires sent to the patients' general practitioners, or by telephone calls. Between January 1988 and December 2005, a total of 505 consecutive patients (300 males, 205 females; mean age 52 years; range: 5 to 77 years) underwent heart valve replacement using a CarboMedics mechanical prosthesis. Aortic valve replacement (AVR) was performed in 308 patients, mitral valve replacement (MVR) in 134 patients, and double-valve replacement (DVR) in 62 patients. The follow up was 95.4% complete; the mean follow up was 7.5 years, and the total follow up 3,718 patient-years. Thromboembolic and bleeding complications represented the leading cause of valve-related events (104/195), of valve-related mortality (15/25), and of the need for repeat surgery (9/16). Valve thrombosis occurred in 12 patients. Implantation in the mitral position was identified as a risk factor (HR = 15.07; CI: 8.41-23.07; p 0.0001). Thromboembolism occurred in 32 patients; the use of antiplatelet agents was found to be a protective factor (HR = 0.23; CI: 0.08-0.70; p = 0.01). Bleeding events occurred in 52 patients; risk factors for bleeding events included a history of thromboembolic or bleeding complications (HR = 2.70; CI: 1.33-5.26; p = 0.006) and an unstable International Normalized Ratio (INR) (HR = 2.86; CI: 1.01-8.08; p = 0.05). After mechanical heart valve replacement, the only risk factors for bleeding complications were an unstable INR and a history of thromboembolic or bleeding events. The use of antiplatelet agents proved to be a protective factor against thromboembolic events.
- 1 November 2011
- Vol. 20 (6) , 673-80
Risk factors for valve-related complications after mechanical heart valve replacement in 505 patients with long-term follow up.
Currently, valve thrombosis, thromboembolic events and bleeding events account for 75% of all complications that occur after mechanical heart valve replacement. The study aim was to determine the main risk factors for valve-related complications in patients undergoing mechanical heart valve replacement. Data were available from the systematic follow up of patients who had received a CarboMedics bileaflet mechanical heart valve replacement at the authors' institution. Follow up examinations were conducted prospectively at two-year intervals, via questionnaires sent to the patients' general practitioners, or by telephone calls. Between January 1988 and December 2005, a total of 505 consecutive patients (300 males, 205 females; mean age 52 years; range: 5 to 77 years) underwent heart valve replacement using a CarboMedics mechanical prosthesis. Aortic valve replacement (AVR) was performed in 308 patients, mitral valve replacement (MVR) in 134 patients, and double-valve replacement (DVR) in 62 patients. The follow up was 95.4% complete; the mean follow up was 7.5 years, and the total follow up 3,718 patient-years. Thromboembolic and bleeding complications represented the leading cause of valve-related events (104/195), of valve-related mortality (15/25), and of the need for repeat surgery (9/16). Valve thrombosis occurred in 12 patients. Implantation in the mitral position was identified as a risk factor (HR = 15.07; CI: 8.41-23.07; p 0.0001). Thromboembolism occurred in 32 patients; the use of antiplatelet agents was found to be a protective factor (HR = 0.23; CI: 0.08-0.70; p = 0.01). Bleeding events occurred in 52 patients; risk factors for bleeding events included a history of thromboembolic or bleeding complications (HR = 2.70; CI: 1.33-5.26; p = 0.006) and an unstable International Normalized Ratio (INR) (HR = 2.86; CI: 1.01-8.08; p = 0.05). After mechanical heart valve replacement, the only risk factors for bleeding complications were an unstable INR and a history of thromboembolic or bleeding events. The use of antiplatelet agents proved to be a protective factor against thromboembolic events.