HFHai-Wei Fu

Hai-Wei Fu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Hai-Wei Fu has a total of 21 co-authors. Here are the top co-authors by number of shared publications:

  • Jijun Ding

    Ministry of Key Laboratory on Photoelectric Oil-Gas Logging and Detecting, School of Science, Xi’an Shiyou University, Xi’an 710065, China

    2 shared publications
  • Jingle Zhang

    Ministry of Key Laboratory on Photoelectric Oil-Gas Logging and Detecting, School of Science, Xi’an Shiyou University, Xi’an 710065, China

    2 shared publications
  • Min Shao

    School of Science, Xian Shiyou University, Xian, China

    2 shared publications
  • Min Zhang

    Ministry of Key Laboratory on Photoelectric Oil-Gas Logging and Detecting, School of Science, Xi’an Shiyou University, Xi’an 710065, China

    2 shared publications
  • Xue-Guang Qiao

    2 shared publications
  • Yi Zhu

    Ministry of Key Laboratory on Photoelectric Oil-Gas Logging and Detecting, School of Science, Xi’an Shiyou University, Xi’an 710065, China

    2 shared publications

Latest Publications

  • Fabrication of three-dimensional zinc oxide nanoflowers for high-sensitivity fiber-optic ammonia gas sensors

    by Yi Zhu, Haiwei Fu, Jijun Ding, Huidong Li, Min Zhang, Jingle Zhang, Yinggang Liu

    ZnO is identified as one of the promising coating materials in optical fiber for ammonia gas sensors. In this work, three-dimensional ZnO nanoflowers are fabricated via a facile hydrothermal method and used as sensitive coating materials for optical fiber ammonia gas sensors. Results show that the sensor with ZnO nanoflowers exhibits a high sensitivity of 5.75  pm/(μg·L−1) for ammonia concentration ranging from 0 to 5460  μg·L−1, which is more than 2.6 times higher than that of the sensor with a coating of ZnO microspheres [2.2  pm/(μg·L−1)].


  • Graphene-oxide-coated interferometric optical microfiber ethanol vapor sensor

    by Jingle Zhang, Haiwei Fu, Jijun Ding, Min Zhang, Yi Zhu

    A graphene-oxide-coated interferometric microfiber-sensor-based polarization-maintaining optical fiber is proposed for highly sensitive detecting for ethanol vapor concentration at room temperature in this paper. The strong sensing capability of the sensor to detect the concentration of ethanol vapor is demonstrated, taking advantage of the evanescent field enhancement and gas absorption of a graphene-oxide-coated microfiber. The transmission spectrum of the sensor varies with concentrations of ethanol vapor, and the redshift of the transmission spectrum has been analyzed for the concentration range from 0 to 80 ppm with sensitivity as high as 0.138 nm/ppm. The coated graphene oxide layer induces the evanescent field enhancement and gas selective adsorption, which improves sensitivity and selectivity of the microfiber gas sensor for ethanol vapor detection.


    • 1 June 2014
      • Vol. 34  (6) , 1722-6

    [Research on high sensitivity temperature sensor based on Mach-Zehnder interferometer with waist-enlarged fiber bitapers].

    by Na Zhano, Hai-Wei Fu, Min Shao, Hui-Dong Li, Ying-Gang Liu, Xue-Guang Qiao

    Optical fiber sensing technology is one of the very promising techniques in sensing fields. A high sensitivity high temperature sensor based on inline optical fiber Mach-Zehnder(M-Z) interferometer by using standard single mode fiber with two waist-enlarged bitapers is proposed in the present paper. The waist-enlarged bitapers are considered as couplers, the distance between the two bitapers is the sensing arm. The light in the lead-in fiber core couples into the sensing arms' fiber core and cladding by the first bitaper, and then propagate in them. The phase difference between core mode and cladding mode is produced when the light reaches the second bitaper. Then the second bitaper couples the light into the lead-out single-mode fiber to get the interference spectrum. The sensors with different length were fabricated. The relationship between the sensor length and interference period, and the temperature response of the.sensor were studied by experiments. The results show that the 35 mm long sensor has a high sensitivity of 0.115 nm x degrees C(-1) in the range of 30-400 degrees C. The transmission spectrum of the sensor was also analyzed by the fast Fourier transform. It shows that only LP01 mode and LP08 mode propagate in the sensor. Thesensor has advantages of small size, high precision, and immunity to electromagnetic inteference. In addition, it is of easy fabrication, high signal-to-noise ratio, light weight, and high sensitivity, and could be operated under high temperature. This kind of sensor is a good candidate for high temperature measurement of hot gas, oil and gas well logging and other areas.

  • In-fiber Mach-Zehnder interferometer based on fiber core etched air-bubble and core diameter mismatch for liquid refractive index sensing

    by Li Hui-Dong, Fu Hai-Wei, Shao Min, Zhao Na, Qiao Xue-Guang, Liu Ying-Gang, Li Yan, Yan Xu

    介绍了一种基于光纤气泡和纤芯失配的Mach-Zehnder干涉液体折射率传感器. 将两根纤芯经过腐蚀的普通单模光纤熔接在一起, 在熔接点处形成一个气泡, 在距气泡20 mm处级联一段20 mm的细芯光纤, 再接入一段单模光纤, 形成单模光纤-气泡-单模光纤-细芯光纤-单模光纤结构的传感器. 气泡与光纤芯径失配处的两个节点起到光纤耦合器的作用, 从而形成光纤Mach-Zehnder干涉仪. 环境液体折射率的变化,将使得传感器透射谱能量发生变化, 通过测量干涉谱波峰峰值能量从而实现对折射率的测量. 并对所制作传感器的折射率响应特性进行了实验研究, 实验结果表明干涉谱波峰峰值能量与环境液体折射率之间存在良好的线性关系, 当环境液体折射率变化范围在1.3511.402时, 响应灵敏度为143.537 dB/RIU, 线性度0.996. 该传感器在生物化学领域有较好的应用前景.


    • 1 September 2012
      • Vol. 32  (9) , 2318-21

    [Simultaneous measurement of temperature and strain based on long-period fiber grating and Sagnac interferometer spectrum].

    by Min Shao, Xue-Guang Qiao, Xue Zhao, Hai-Wei Fu, Zhen-An Jia, De-Quan Feng

    A simultaneous measurement system of temperature and strain is proposed and fabricated, which has advantages of low cost and easy structure. The system is formed by combining a long period fiber grating with a polarization-maintaining fiber Sagnac loop. The transmission spectrum of the fiber Sagnac interferometer is modulated by LPFG. The simultaneous measurement of temperature and strain can be realized. The experimental results show that the wavelength of the dip is varied with temperature changing and applied strain on polarization-maintaining fiber, and the intensity of the dip is changed with applied strain on LPFG. The temperature sensitivity of the system is 0.181 81 nm x degrees C(-1), the strain sensitivity of LPFG is 0. 005 283 dB x mu epsilon(-1), and the strain sensitivity of polarization-maintaining fiber Sagnac loop is 0.015 72 nm x mu epsilon(-1). The experimental system indicates that the proposal is feasible and has an application prospect.