Roman C. Ostermann
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Roman C. Ostermann has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Thomas Manfred Tiefenboeck
Department of Trauma Surgery, University Clinic of Orthopedics and Trauma Surgery, Medical University of Vienna, Waehringer Guertel 18-20, 1090 Vienna, Austria
3 shared publications - Harald Binder
Department of Orthopedics and Trauma-Surgery, Medical University of Vienna, 1090 Vienna, Austria
2 shared publications - Julian Joestl
Department of Trauma Surgery, Medical University of Vienna, Austria
2 shared publications Marcus Hofbauer
Department of Trauma Surgery, Medical University of Vienna, Vienna, Austria
2 shared publicationsPatrick Platzer
Department of Trauma Surgery, Medical University of Vienna, Vienna, Austria
2 shared publications- Sandra Boesmueller
Department of Orthopedics and Trauma Surgery, AUVA Trauma Center Vienna–Meidling, Vienna, Austria
2 shared publications
Latest Publications
- Open Access
- 4 August 2017
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 18 (1) , 1-8
Acromioclavicular joint dislocation treated with Bosworth screw and additional K-wiring: results after 7.8 years – still an adequate procedure?
The acromioclavicular (AC) joint dislocation is a major reason for shoulder instability. Different concepts of treatment and surgical methods are described in the literature. Thus, the purpose of this study was to present our data of long-term follow-up of patients having undergone treatment of acromioclavicular (AC) joint dislocation using the Bosworth Screw with additional K-wiring. This study was conducted as a retrospective single centre data analysis. All patients treated operatively for AC joint dislocation with a Bosworth screw and additional K-wire fixation at our Department were asked to participate in this study. The study population consisted of 22 patients, 20 male and 2 female, with a mean age of 40 years ±15.6 years. Three grade-II lesions, 13 grade-III lesions, four grade-IV lesions and two grade-V lesions according to the Rockwood classification were found. The overall mean clinical outcome at the latest follow up was: Constant 95, DASH 6.4, ASES 94.6, SST 99.02, UCLA 33.1, ACJI 91.82 and VAS 0.29 – representing a good-to-excellent long-term outcome in all patients after at least 2 years follow-up (range; 2 - 19 years). Overall, 19 patients (86%) reported to be very satisfied with the achieved result, 15 patients (68%) reported to be able to participate in every sports activity and 16 patients (73%) reported to be able to perform their daily work without limitations. Overall, complications occurred in three patients (14%). Only one patient remained unsatisfied with the achieved result. Summarizing, our reported results showed that surgical fixation of acute AC joint dislocation with a Bosworth screw and additional K-wire fixation leads to good-to-excellent functional outcome and highly satisfactory results in the majority of patients. Despite its complications, in accordance with our results, Bosworth screw fixation with additional K-wiring in AC joint dislocation represents an adequate surgical procedure. Level of Evidence: Level IV, retrospective study.
- 4 August 2017
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 18 (1) , 1-8
Open AccessAcromioclavicular joint dislocation treated with Bosworth screw and additional K-wiring: results after 7.8 years – still an adequate procedure?
The acromioclavicular (AC) joint dislocation is a major reason for shoulder instability. Different concepts of treatment and surgical methods are described in the literature. Thus, the purpose of this study was to present our data of long-term follow-up of patients having undergone treatment of acromioclavicular (AC) joint dislocation using the Bosworth Screw with additional K-wiring. This study was conducted as a retrospective single centre data analysis. All patients treated operatively for AC joint dislocation with a Bosworth screw and additional K-wire fixation at our Department were asked to participate in this study. The study population consisted of 22 patients, 20 male and 2 female, with a mean age of 40 years ±15.6 years. Three grade-II lesions, 13 grade-III lesions, four grade-IV lesions and two grade-V lesions according to the Rockwood classification were found. The overall mean clinical outcome at the latest follow up was: Constant 95, DASH 6.4, ASES 94.6, SST 99.02, UCLA 33.1, ACJI 91.82 and VAS 0.29 – representing a good-to-excellent long-term outcome in all patients after at least 2 years follow-up (range; 2 - 19 years). Overall, 19 patients (86%) reported to be very satisfied with the achieved result, 15 patients (68%) reported to be able to participate in every sports activity and 16 patients (73%) reported to be able to perform their daily work without limitations. Overall, complications occurred in three patients (14%). Only one patient remained unsatisfied with the achieved result. Summarizing, our reported results showed that surgical fixation of acute AC joint dislocation with a Bosworth screw and additional K-wire fixation leads to good-to-excellent functional outcome and highly satisfactory results in the majority of patients. Despite its complications, in accordance with our results, Bosworth screw fixation with additional K-wiring in AC joint dislocation represents an adequate surgical procedure. Level of Evidence: Level IV, retrospective study.
- Open Access
- 23 January 2017
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 18 (1) , 1-6
Displaced Neer Type IIB distal-third clavicle fractures—Long-term clinical outcome after plate fixation and additional screw augmentation for coracoclavicular instability
Unstable Neer Type IIB fractures require meticulous surgical treatment. Thus, the aim of this study was to present long-term outcomes after plate fixation and minimally invasive coracoclavicular (CC) stabilization using screw fixation. A consecutive series of patients with unstable Neer Type IIB displaced clavicle fractures, treated by open reduction and internal fixation (ORIF) with a plate and additional screw fixation for coracoclavicular ligament instability, was reviewed in order to determine long-term clinical and radiological outcome. Seven patients, six males and one female, with a mean age of 37 ± 8 years (median: 36 years; range, 28–51 years), were evaluated. At latest follow-up, after a mean of 67 months (range, 11–117 months), patients presented with the following mean scores: DASH: 0.57, ASES: 98.81, UCLA: 34.29, VAS: 0.43, Simple Shoulder Test: 11.57. However, two complications were observed: one case of implant loosening and one non-union. There were no differences observed between the CC distances comparing postoperative X-rays to those in final follow-up. In 25% of our patients early postoperative complications occurred. In all patients reoperation was necessary to remove the implanted screw. The results of the present study indicate that the treatment of Neer Type IIB lateral clavicle fractures with ORIF using a plate and additional CC screw fixation, leads to satisfying clinical and radiological outcomes in the long-term. However, considering an early postoperative complication rate of 25% and a 100% rate of secondary surgery due to removal of the CC screw does not seem to justify this technique anymore.
- 23 January 2017
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 18 (1) , 1-6
Open AccessDisplaced Neer Type IIB distal-third clavicle fractures—Long-term clinical outcome after plate fixation and additional screw augmentation for coracoclavicular instability
Unstable Neer Type IIB fractures require meticulous surgical treatment. Thus, the aim of this study was to present long-term outcomes after plate fixation and minimally invasive coracoclavicular (CC) stabilization using screw fixation. A consecutive series of patients with unstable Neer Type IIB displaced clavicle fractures, treated by open reduction and internal fixation (ORIF) with a plate and additional screw fixation for coracoclavicular ligament instability, was reviewed in order to determine long-term clinical and radiological outcome. Seven patients, six males and one female, with a mean age of 37 ± 8 years (median: 36 years; range, 28–51 years), were evaluated. At latest follow-up, after a mean of 67 months (range, 11–117 months), patients presented with the following mean scores: DASH: 0.57, ASES: 98.81, UCLA: 34.29, VAS: 0.43, Simple Shoulder Test: 11.57. However, two complications were observed: one case of implant loosening and one non-union. There were no differences observed between the CC distances comparing postoperative X-rays to those in final follow-up. In 25% of our patients early postoperative complications occurred. In all patients reoperation was necessary to remove the implanted screw. The results of the present study indicate that the treatment of Neer Type IIB lateral clavicle fractures with ORIF using a plate and additional CC screw fixation, leads to satisfying clinical and radiological outcomes in the long-term. However, considering an early postoperative complication rate of 25% and a 100% rate of secondary surgery due to removal of the CC screw does not seem to justify this technique anymore.
- Open Access
- 2 March 2015
- Published by Wiley in Arthroscopy Techniques
- Vol. 4 (2) , e91-5
The “Labral Bridge”: A Novel Technique for Arthroscopic Anatomic Knotless Bankart Repair
Arthroscopic Bankart repair with suture anchors is widely considered a mainstay for surgical treatment of anterior shoulder instability after recurrent anterior shoulder dislocations. Traditionally, the displaced capsulolabral complex is restored and firmly attached to the glenoid by placing multiple suture anchors individually from a 5‐ to 3‐o'clock position. A variety of different techniques using different anchor designs and materials have been described. Knotless anchors are widely used nowadays for shoulder instability repair, providing a fast and secure way of labral fixation with favorable long‐term outcomes. However, these techniques result in a concentrated point load of the reduced labrum to the glenoid at each suture anchor. We describe a technique, developed by the first author, using a 1.5‐mm LabralTape (Arthrex, Naples, FL) in combination with knotless suture anchors (3.5‐mm PEEK [polyether ether ketone] PushLock anchors; Arthrex), for hybrid fixation of the labrum. The LabralTape is used to secure the torn labrum to the glenoid between each suture anchor, thus potentially providing a more even pressure distribution. Technique Video: video See video under supplementary data.
- 2 March 2015
- Published by Wiley in Arthroscopy Techniques
- Vol. 4 (2) , e91-5
Open AccessThe “Labral Bridge”: A Novel Technique for Arthroscopic Anatomic Knotless Bankart Repair
Arthroscopic Bankart repair with suture anchors is widely considered a mainstay for surgical treatment of anterior shoulder instability after recurrent anterior shoulder dislocations. Traditionally, the displaced capsulolabral complex is restored and firmly attached to the glenoid by placing multiple suture anchors individually from a 5‐ to 3‐o'clock position. A variety of different techniques using different anchor designs and materials have been described. Knotless anchors are widely used nowadays for shoulder instability repair, providing a fast and secure way of labral fixation with favorable long‐term outcomes. However, these techniques result in a concentrated point load of the reduced labrum to the glenoid at each suture anchor. We describe a technique, developed by the first author, using a 1.5‐mm LabralTape (Arthrex, Naples, FL) in combination with knotless suture anchors (3.5‐mm PEEK [polyether ether ketone] PushLock anchors; Arthrex), for hybrid fixation of the labrum. The LabralTape is used to secure the torn labrum to the glenoid between each suture anchor, thus potentially providing a more even pressure distribution. Technique Video: video See video under supplementary data.
- 12 August 2014
- Published by Springer Nature in International Orthopaedics
- Vol. 39 (1) , 119-124
Injury severity in ice skating: an epidemiologic analysis using a standardised injury classification system
Although injuries sustained during ice skating have been reported to be more serious than other forms of skating, the potential injury risks are often underestimated by skating participants. The purpose of this study was to give a descriptive overview of injury patterns occurring during ice skating. Special emphasis was put on injury severity by using a standardised injury classification system. Over a six month period, all patients treated with ice-skating-related injuries at Europe’s largest hospital were included. Patient demographics were collected and all injuries categorised according to the Abbreviated Injury Scale (AIS) 2005. A descriptive statistic and logistic regression analysis was performed. Three hundred and forty-one patients (134 M, 207 F) were included in this study. Statistical analysis revealed that age had a significant influence on injury severity. People > 50 years had a higher risk of sustaining a more severe injury according to the AIS compared with younger skaters. Furthermore, the risk of head injury was significantly lower for people aged between 18 and 50 years than for people < 18 years (p = 0.0007) and significantly higher for people > 50 years than for people aged between 18 and 50 years (p = 0.04). The severity of ice-skating injuries is associated with the patient’s age, showing more severe injuries in older patients. Awareness should be raised among the public and physicians about the risks associated with this activity in order to promote further educational interventions and the use of protective gear.
- 12 August 2014
- Published by Springer Nature in International Orthopaedics
- Vol. 39 (1) , 119-124
Injury severity in ice skating: an epidemiologic analysis using a standardised injury classification system
Although injuries sustained during ice skating have been reported to be more serious than other forms of skating, the potential injury risks are often underestimated by skating participants. The purpose of this study was to give a descriptive overview of injury patterns occurring during ice skating. Special emphasis was put on injury severity by using a standardised injury classification system. Over a six month period, all patients treated with ice-skating-related injuries at Europe’s largest hospital were included. Patient demographics were collected and all injuries categorised according to the Abbreviated Injury Scale (AIS) 2005. A descriptive statistic and logistic regression analysis was performed. Three hundred and forty-one patients (134 M, 207 F) were included in this study. Statistical analysis revealed that age had a significant influence on injury severity. People > 50 years had a higher risk of sustaining a more severe injury according to the AIS compared with younger skaters. Furthermore, the risk of head injury was significantly lower for people aged between 18 and 50 years than for people < 18 years (p = 0.0007) and significantly higher for people > 50 years than for people aged between 18 and 50 years (p = 0.04). The severity of ice-skating injuries is associated with the patient’s age, showing more severe injuries in older patients. Awareness should be raised among the public and physicians about the risks associated with this activity in order to promote further educational interventions and the use of protective gear.