Latest Publications
- 4 February 2026
- Published by Taylor & Francis in Clinical and Experimental Optometry
- Vol. 109 (5) , 904-916
Visual performance of spectacle films utilising opaque, non-refractive features for potential myopia management
A non-refractive approach for potential myopia management is introduced as spectacle films with opaque features, hypothesised to modulate retinal ganglion cell activity away from the baseline state of the eye. Visual performance of these spectacle films is currently unknown. The aim of this work is to compare the visual performance of spectacle films with opaque non-refractive features (test), MiYOSMART (control: MS), and single vision (control: SV) lenses. This was a prospective, randomised, unmasked, cross-over study where 37 myopic adults (18-42 years) wore each lens for a minimum of 5 days. Subjective visual performance was assessed with a 1-10 numeric rating scale for clarity of vision, vision at night, vision when walking, and overall vision satisfaction and visual acuity (monocular at 6 m and binocular at 6 m and 40 cm). Willingness-to-purchase, based on vision and myopia efficacy, was assessed with a binary Yes/No response. Test and SV were rated higher than MS (p ≤ 0.005) for all subjective ratings, while SV was rated higher than test (p ≤ 0.02) for all ratings except vision when walking (p = 0.11). A higher proportion were willing to purchase both test and SV compared to MS based on vision (p ≤ 0.001), with no difference between test and SV (p = 0.20). A higher proportion were willing to purchase SV compared to MS based on myopia efficacy (p = 0.005), with no difference between test and either control (p > 0.06). SV was significantly better than MS for acuity at 40 cm (p = 0.004) with no differences between lenses for other acuity measurements (p > 0.1). Test offered better subjective visual performance than MS with higher proportions of participants willing to purchase based on vision. Test offered worse subjective visual performance than SV with no differences in willingness-to-purchase questions. SV offered better visual performance than MS and higher proportions of participants willing to purchase for vision or myopia management.
- 4 February 2026
- Published by Taylor & Francis in Clinical and Experimental Optometry
- Vol. 109 (5) , 904-916
Visual performance of spectacle films utilising opaque, non-refractive features for potential myopia management
A non-refractive approach for potential myopia management is introduced as spectacle films with opaque features, hypothesised to modulate retinal ganglion cell activity away from the baseline state of the eye. Visual performance of these spectacle films is currently unknown. The aim of this work is to compare the visual performance of spectacle films with opaque non-refractive features (test), MiYOSMART (control: MS), and single vision (control: SV) lenses. This was a prospective, randomised, unmasked, cross-over study where 37 myopic adults (18-42 years) wore each lens for a minimum of 5 days. Subjective visual performance was assessed with a 1-10 numeric rating scale for clarity of vision, vision at night, vision when walking, and overall vision satisfaction and visual acuity (monocular at 6 m and binocular at 6 m and 40 cm). Willingness-to-purchase, based on vision and myopia efficacy, was assessed with a binary Yes/No response. Test and SV were rated higher than MS (p ≤ 0.005) for all subjective ratings, while SV was rated higher than test (p ≤ 0.02) for all ratings except vision when walking (p = 0.11). A higher proportion were willing to purchase both test and SV compared to MS based on vision (p ≤ 0.001), with no difference between test and SV (p = 0.20). A higher proportion were willing to purchase SV compared to MS based on myopia efficacy (p = 0.005), with no difference between test and either control (p > 0.06). SV was significantly better than MS for acuity at 40 cm (p = 0.004) with no differences between lenses for other acuity measurements (p > 0.1). Test offered better subjective visual performance than MS with higher proportions of participants willing to purchase based on vision. Test offered worse subjective visual performance than SV with no differences in willingness-to-purchase questions. SV offered better visual performance than MS and higher proportions of participants willing to purchase for vision or myopia management.
- 1 February 2026
- Published by Wiley in Optometry and Vision Science
- Vol. 103 (2) , e70023
Visual performance of phase alteration utilizing sub‐elements lenses for potential myopia management
Purpose: To compare the visual performance (VP) of P.A.U.S.E. spectacle lenses (tests) against defocus incorporated multiple segments (DIMS; control). Methods: This randomized, single‐masked study included 48 participants aged 18–41 years who wore five tests (T1, T2, T4, T5, T6) and DIMS. VP was assessed through the full‐lens and inferior treatment zone. Full‐lens visual‐acuity (VA) based measurements comprised monocular high‐ and low‐contrast VA (HCVA/LCVA) at 6 m and binocular HCVA at 6 m and 40 cm. Assessments through the treatment zone comprised HCVA at 40 cm and subjective ratings (1–10 scale) of near vision‐clarity and ease‐of‐reading. VP was assessed after 3 days of wear (full‐lens) using subjective ratings of vision‐clarity, night‐vision, vision‐while‐walking, eyestrain, overall‐vision‐satisfaction, and willingness‐to‐purchase (yes/no: based on vision and myopia management efficacy). Analyses were performed using linear mixed models and the X 2 test. Significance was set at 5%. Results: Full‐lens binocular HCVA at 40 cm was significantly better with three tests (T2, T4, T5) compared to DIMS ( p ≤ 0.022), whereas there were no differences between any test and DIMS for monocular or binocular HCVA at 6 m ( p > 0.5). Full‐lens monocular LCVA at 6 m was significantly better with DIMS compared to T4 ( p = 0.0057). Through the treatment zone, four tests (T2, T4, T5, T6) were significantly better than DIMS for binocular HCVA at 40 cm ( p < 0.0001), near vision‐clarity ( p ≤ 0.0011) and ease‐of‐reading ( p ≤ 0.0014). T2 was rated significantly higher than DIMS for night‐vision ( p = 0.0085) and overall‐vision‐satisfaction ( p = 0.0495), whereas DIMS was rated higher than T1 for vision‐clarity ( p = 0.0001). There were no significant differences between DIMS and any test for other subjective ratings ( p > 0.07), nor willingness‐to‐purchase based on vision ( p > 0.2) or myopia management efficacy ( p > 0.6). Conclusions: Most of the test lenses achieved better VP through the treatment zone compared to the DIMS control. T2 showed better overall VP compared to DIMS, whereas DIMS showed better overall VP compared to T1.
- 1 February 2026
- Published by Wiley in Optometry and Vision Science
- Vol. 103 (2) , e70023
Visual performance of phase alteration utilizing sub‐elements lenses for potential myopia management
Purpose: To compare the visual performance (VP) of P.A.U.S.E. spectacle lenses (tests) against defocus incorporated multiple segments (DIMS; control). Methods: This randomized, single‐masked study included 48 participants aged 18–41 years who wore five tests (T1, T2, T4, T5, T6) and DIMS. VP was assessed through the full‐lens and inferior treatment zone. Full‐lens visual‐acuity (VA) based measurements comprised monocular high‐ and low‐contrast VA (HCVA/LCVA) at 6 m and binocular HCVA at 6 m and 40 cm. Assessments through the treatment zone comprised HCVA at 40 cm and subjective ratings (1–10 scale) of near vision‐clarity and ease‐of‐reading. VP was assessed after 3 days of wear (full‐lens) using subjective ratings of vision‐clarity, night‐vision, vision‐while‐walking, eyestrain, overall‐vision‐satisfaction, and willingness‐to‐purchase (yes/no: based on vision and myopia management efficacy). Analyses were performed using linear mixed models and the X 2 test. Significance was set at 5%. Results: Full‐lens binocular HCVA at 40 cm was significantly better with three tests (T2, T4, T5) compared to DIMS ( p ≤ 0.022), whereas there were no differences between any test and DIMS for monocular or binocular HCVA at 6 m ( p > 0.5). Full‐lens monocular LCVA at 6 m was significantly better with DIMS compared to T4 ( p = 0.0057). Through the treatment zone, four tests (T2, T4, T5, T6) were significantly better than DIMS for binocular HCVA at 40 cm ( p < 0.0001), near vision‐clarity ( p ≤ 0.0011) and ease‐of‐reading ( p ≤ 0.0014). T2 was rated significantly higher than DIMS for night‐vision ( p = 0.0085) and overall‐vision‐satisfaction ( p = 0.0495), whereas DIMS was rated higher than T1 for vision‐clarity ( p = 0.0001). There were no significant differences between DIMS and any test for other subjective ratings ( p > 0.07), nor willingness‐to‐purchase based on vision ( p > 0.2) or myopia management efficacy ( p > 0.6). Conclusions: Most of the test lenses achieved better VP through the treatment zone compared to the DIMS control. T2 showed better overall VP compared to DIMS, whereas DIMS showed better overall VP compared to T1.
- Open Access
- 7 August 2025
- Published by Elsevier in Ophthalmology
- Vol. 132 (12) , 1344-1356
Spatio-Temporal Optical Phase Kit for Myopia Control
- 7 August 2025
- Published by Elsevier in Ophthalmology
- Vol. 132 (12) , 1344-1356
Open AccessSpatio-Temporal Optical Phase Kit for Myopia Control
- Open Access
- 31 May 2024
- Published by Springer Nature in Ophthalmic and Physiological Optics
- Vol. 44 (6) , 1202-1214
Refractive power profiles of commercially available soft multifocal contact lenses for myopia control
Purpose: Lens power profiles can provide valuable insights on the imposed optical defocus and visual experience of contact lens wearers, especially in the context of myopia control. This study measured the refractive power profiles of multifocal soft contact lenses (MFCLs) currently used or that have the potential for use in myopia control using high spatial resolution aberrometry. The instrument's repeatability for determining MFCLs power profiles was also assessed. Method: The power profiles of 10 MFCLs of various designs (centre‐distance, centre‐near and extended depth of focus) were measured using the Lambda‐X NIMO EVO , a phase shifting Schlieren‐based device. Power profiles were graphically expressed as measured power at each chord position and the maximum add power was calculated. The repeatability of the NIMO EVO was expressed as the within‐subject standard deviation at each chord position for a subset of five MFCLs. Results: The measured distance powers differed from nominal powers for more than half of the MFCLs with a definable distance zone. There were variations in the chord position of the distance and near correction zones, rate of power transitions and calculated maximum add between the MFCLs which did not depend on lens design. For half of the MFCLs, the power profile shape was inconsistent between different nominal back vertex powers of the same design. The repeatability of the NIMO EVO was dependent on the lens design, with designs featuring faster rates of power change exhibiting worse repeatability. Conclusions: Significant differences in MFCL power profiles were found which were not adequately represented in labelling. This is likely due to the small number of parameters used to define lens power characteristics. Eye health care practitioners should be aware of potential differences in power profiles between different MFCLs, which will impact the retinal defocus introduced during lens wear and the wearer's visual experience.
- 31 May 2024
- Published by Springer Nature in Ophthalmic and Physiological Optics
- Vol. 44 (6) , 1202-1214
Open AccessRefractive power profiles of commercially available soft multifocal contact lenses for myopia control
Purpose: Lens power profiles can provide valuable insights on the imposed optical defocus and visual experience of contact lens wearers, especially in the context of myopia control. This study measured the refractive power profiles of multifocal soft contact lenses (MFCLs) currently used or that have the potential for use in myopia control using high spatial resolution aberrometry. The instrument's repeatability for determining MFCLs power profiles was also assessed. Method: The power profiles of 10 MFCLs of various designs (centre‐distance, centre‐near and extended depth of focus) were measured using the Lambda‐X NIMO EVO , a phase shifting Schlieren‐based device. Power profiles were graphically expressed as measured power at each chord position and the maximum add power was calculated. The repeatability of the NIMO EVO was expressed as the within‐subject standard deviation at each chord position for a subset of five MFCLs. Results: The measured distance powers differed from nominal powers for more than half of the MFCLs with a definable distance zone. There were variations in the chord position of the distance and near correction zones, rate of power transitions and calculated maximum add between the MFCLs which did not depend on lens design. For half of the MFCLs, the power profile shape was inconsistent between different nominal back vertex powers of the same design. The repeatability of the NIMO EVO was dependent on the lens design, with designs featuring faster rates of power change exhibiting worse repeatability. Conclusions: Significant differences in MFCL power profiles were found which were not adequately represented in labelling. This is likely due to the small number of parameters used to define lens power characteristics. Eye health care practitioners should be aware of potential differences in power profiles between different MFCLs, which will impact the retinal defocus introduced during lens wear and the wearer's visual experience.
- 29 November 2023
- Published by DOZ-Verlag Optische Fachveroffentlichung GmbH in Optometry & Contact Lenses
- Vol. 4 (1) , 28-34
Vor- und Nachteile von Power Mapping bei weichen Kontaktlinsen
Purpose. To provide an overview of currently available meth- ods and instruments for the measurement of soft contact lens power maps, together with their advantages and potential shortcomings. Material and Methods. The three leading measurement prin- ciples of Moiré Fringe, Shack-Hartmann and Phase Shifting Schlieren were identified, and the relevant literature reviewed and technical specifications summarised. To demonstrate some of the potential deficiencies associated with optical power mapping, a series of measurements were conducted on toric, multifocal and extended depth of focus lenses, using one representative instrument. Raw measured data were analysed using various analysis tools and parameters. Results. Power maps and power profiles are presented for the various lens types. Different smoothing filter settings resulted in significantly different power profiles near the optical centre. The ‘Power versus Azimuth’ profiles showed unexpected results. Conclusion. While all three methods are generally reliable and easy to use, there are still some limitations which need to be considered when interpreting the results. In particular, the profile filter settings need to be chosen carefully for multifocal and extended depth of focus lenses. The need for accurate refractive index data for lens material and solution was demonstrated. Keywords Soft contact lenses, power maps, power profiles, Moiré Fringe, Shack-Hartmann, Phase Shifting Schlieren
- 29 November 2023
- Published by DOZ-Verlag Optische Fachveroffentlichung GmbH in Optometry & Contact Lenses
- Vol. 4 (1) , 28-34
Vor- und Nachteile von Power Mapping bei weichen Kontaktlinsen
Purpose. To provide an overview of currently available meth- ods and instruments for the measurement of soft contact lens power maps, together with their advantages and potential shortcomings. Material and Methods. The three leading measurement prin- ciples of Moiré Fringe, Shack-Hartmann and Phase Shifting Schlieren were identified, and the relevant literature reviewed and technical specifications summarised. To demonstrate some of the potential deficiencies associated with optical power mapping, a series of measurements were conducted on toric, multifocal and extended depth of focus lenses, using one representative instrument. Raw measured data were analysed using various analysis tools and parameters. Results. Power maps and power profiles are presented for the various lens types. Different smoothing filter settings resulted in significantly different power profiles near the optical centre. The ‘Power versus Azimuth’ profiles showed unexpected results. Conclusion. While all three methods are generally reliable and easy to use, there are still some limitations which need to be considered when interpreting the results. In particular, the profile filter settings need to be chosen carefully for multifocal and extended depth of focus lenses. The need for accurate refractive index data for lens material and solution was demonstrated. Keywords Soft contact lenses, power maps, power profiles, Moiré Fringe, Shack-Hartmann, Phase Shifting Schlieren
- 1 March 2019
- Published by Taylor & Francis in Clinical and Experimental Optometry
- Vol. 103 (2) , 138-147
Peripheral eye length measurement techniques: a review
Along with the rising myopia epidemic is the increasing interest in any ocular parameter that might inform understanding of myopia progression. The relationship between eye length and myopia has long been established but the recent interest in the central and peripheral retina, eye shape, retinal contour, and refractive error development is attracting more clinical and research interest in peripheral eye length measurements. Therefore, peripheral eye length measurements are an important step in the ongoing research involving the peripheral retina. Since the first measurement of peripheral eye length reported in 1991, many techniques and methods have been developed, which vary in many aspects. These techniques involve custom‐built or modified commercially available instruments, with the use of off‐axis targets and other considerations such as eye or head turn of the subject. The wide range of methods and instruments used for peripheral eye length measurements make it difficult to compare results and may account for some of the variations in the reported results. Specifications of the different methods are presented along with their advantages and disadvantages. Although researchers acknowledge a good agreement between the modified commercially available optical biometers for peripheral eye length measurement, the Lenstar LS 900 appears to offer better results. Nevertheless, the introduction to the market of an instrument specially designed for peripheral eye length might overcome the issues noted with other methods and could allow for more insights in future research involving the peripheral retina. Moreover, future studies may be able to track peripheral eye length changes and its relationship to the progression of myopia and find out if those changes are responsible for or correlated with important eye conditions.
- 1 March 2019
- Published by Taylor & Francis in Clinical and Experimental Optometry
- Vol. 103 (2) , 138-147
Peripheral eye length measurement techniques: a review
Along with the rising myopia epidemic is the increasing interest in any ocular parameter that might inform understanding of myopia progression. The relationship between eye length and myopia has long been established but the recent interest in the central and peripheral retina, eye shape, retinal contour, and refractive error development is attracting more clinical and research interest in peripheral eye length measurements. Therefore, peripheral eye length measurements are an important step in the ongoing research involving the peripheral retina. Since the first measurement of peripheral eye length reported in 1991, many techniques and methods have been developed, which vary in many aspects. These techniques involve custom‐built or modified commercially available instruments, with the use of off‐axis targets and other considerations such as eye or head turn of the subject. The wide range of methods and instruments used for peripheral eye length measurements make it difficult to compare results and may account for some of the variations in the reported results. Specifications of the different methods are presented along with their advantages and disadvantages. Although researchers acknowledge a good agreement between the modified commercially available optical biometers for peripheral eye length measurement, the Lenstar LS 900 appears to offer better results. Nevertheless, the introduction to the market of an instrument specially designed for peripheral eye length might overcome the issues noted with other methods and could allow for more insights in future research involving the peripheral retina. Moreover, future studies may be able to track peripheral eye length changes and its relationship to the progression of myopia and find out if those changes are responsible for or correlated with important eye conditions.
- 1 June 2018
- Published by Elsevier in Contact Lens and Anterior Eye
- Vol. 41, S22-S23
Visual performance with commercial soft multifocal contact lenses
- 1 June 2018
- Published by Elsevier in Contact Lens and Anterior Eye
- Vol. 41, S22-S23
Visual performance with commercial soft multifocal contact lenses
- 1 June 2018
- Published by Elsevier in Contact Lens and Anterior Eye
- Vol. 41, S22
Evaluation of novel-design extended depth of focus multifocal contact lenses
- 1 June 2018
- Published by Elsevier in Contact Lens and Anterior Eye
- Vol. 41, S22
Evaluation of novel-design extended depth of focus multifocal contact lenses
- 1 June 2018
- Published by Elsevier in Contact Lens and Anterior Eye
- Vol. 41, S23-S24
Evaluation of the potential of novel extended depth-of-focus contact lenses compared with AirOptix AQUA multifocal contact lenses
- 1 June 2018
- Published by Elsevier in Contact Lens and Anterior Eye
- Vol. 41, S23-S24
Evaluation of the potential of novel extended depth-of-focus contact lenses compared with AirOptix AQUA multifocal contact lenses
- 10 January 2018
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 4 (2) , 025004
A novel method to stimulate mechanoreceptors and quantify their threshold values
The increase in the incidence of ocular discomfort has primarily been attributed to: contact lens wear, refractive surgery, meibomian gland dysfunction, and the aging population. Efforts to diagnose, treat and understand the underlying causes have been impeded by a lack of suitable methods to quantify ocular surface sensitivity. Traditional instruments are either inaccurate, difficult to use or not generally available. A new method is presented that utilizes a liquid jet to generate a precisely controlled stimulus to the ocular surface. The stimuli are adjustable in strength to determine sensitivity thresholds for either mechanical, thermal or chemical stimulation. Technical details are described and calibration methods and results are presented for three modes of operation. At the heart of the instrument is a microprocessor controlled microvalve which can operate at a frequency of up to 4 kHz to precisely control flow of the ejected liquid. The stimulus strength can be varied either by the ejected volume or the velocity. Repeatability for the ejected volume was established over a range of different control parameter settings: temperature, pressure, working distance, operating mode and volume. For 10 repeats, the maximum standard deviation was less than 3% of the mean of ejected volume for any particular setting. The maximum error for the lateral targeting of the liquid jet for the 30 mm distance between nozzle and target surface was less than ±0.5 mm. A simplified mathematical model is presented to physically quantify the stimulus strength. Based on the liquid jet concept, a new instrument was developed and technically validated that can apply a precisely controlled stimulus to an ocular surface to determine mechanical, and potentially thermal and chemical sensitivity threshold levels. The strength and the positioning of the applied stimulus can be precisely controlled. Temporal and spatial aspects of corneal sensation can also be investigated with this new instrument.
- 10 January 2018
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 4 (2) , 025004
A novel method to stimulate mechanoreceptors and quantify their threshold values
The increase in the incidence of ocular discomfort has primarily been attributed to: contact lens wear, refractive surgery, meibomian gland dysfunction, and the aging population. Efforts to diagnose, treat and understand the underlying causes have been impeded by a lack of suitable methods to quantify ocular surface sensitivity. Traditional instruments are either inaccurate, difficult to use or not generally available. A new method is presented that utilizes a liquid jet to generate a precisely controlled stimulus to the ocular surface. The stimuli are adjustable in strength to determine sensitivity thresholds for either mechanical, thermal or chemical stimulation. Technical details are described and calibration methods and results are presented for three modes of operation. At the heart of the instrument is a microprocessor controlled microvalve which can operate at a frequency of up to 4 kHz to precisely control flow of the ejected liquid. The stimulus strength can be varied either by the ejected volume or the velocity. Repeatability for the ejected volume was established over a range of different control parameter settings: temperature, pressure, working distance, operating mode and volume. For 10 repeats, the maximum standard deviation was less than 3% of the mean of ejected volume for any particular setting. The maximum error for the lateral targeting of the liquid jet for the 30 mm distance between nozzle and target surface was less than ±0.5 mm. A simplified mathematical model is presented to physically quantify the stimulus strength. Based on the liquid jet concept, a new instrument was developed and technically validated that can apply a precisely controlled stimulus to an ocular surface to determine mechanical, and potentially thermal and chemical sensitivity threshold levels. The strength and the positioning of the applied stimulus can be precisely controlled. Temporal and spatial aspects of corneal sensation can also be investigated with this new instrument.