Lars Geidel
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Lars Geidel has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
- Arne Blumentritt
Trusted Third Party of the University Medicine Greifswald, Greifswald, Ellernholzstr. 1-2, 17475 Greifswald, Germany
3 shared publications - Martin Bialke
Institute for Community Medicine, Department Epidemiology of Health Care and Community Health, University Medicine Greifswald, Ellernholzstr. 1-2, 17475, Greifswald, Germany.
3 shared publications - Thomas Bahls
Institute for Community Medicine, Section Epidemiology of Health Care and Community Health, University Medicine Greifswald, Greifswald, Germany
3 shared publications - Wolfgang Hoffmann
German Center for Neurodegenerative Diseases (DZNE), Site Rostock/Greifswald, Greifswald, Germany
3 shared publications - Henriette Rau
Chair of Sustainability Science and Applied Geography, University of Greifswald, Greifswald, Germany
2 shared publications - Sandra Pasewald
Trusted Third Party of the University Medicine Greifswald, Ellernholzstr. 1-2, 17475, Greifswald, Germany
2 shared publications
Latest Publications
- Open Access
- 19 December 2022
- Published by Springer Nature in BMC Medical Informatics and Decision Making
- Vol. 22 (1) , 1-11
A FHIR has been lit on gICS: facilitating the standardised exchange of informed consent in a large network of university medicine
Background: The Federal Ministry of Education and Research of Germany (BMBF) funds a network of university medicines (NUM) to support COVID-19 and pandemic research at national level. The “COVID-19 Data Exchange Platform” (CODEX) as part of NUM establishes a harmonised infrastructure that supports research use of COVID-19 datasets. The broad consent (BC) of the Medical Informatics Initiative (MII) is agreed by all German federal states and forms the legal base for data processing. All 34 participating university hospitals (NUM sites) work upon a harmonised infrastructural as well as legal basis for their data protection-compliant collection and transfer of their research dataset to the central CODEX platform. Each NUM site ensures that the exchanged consent information conforms to the already-balloted HL7 FHIR consent profiles and the interoperability concept of the MII Task Force “Consent Implementation” (TFCI). The Independent Trusted Third-Party (TTP) of the University Medicine Greifswald supports data protection-compliant data processing and provides the consent management solutions gICS. Methods: Based on a stakeholder dialogue a required set of FHIR-functionalities was identified and technically specified supported by official FHIR experts. Next, a “TTP-FHIR Gateway” for the HL7 FHIR-compliant exchange of consent information using gICS was implemented. A last step included external integration tests and the development of a pre-configured consent template for the BC for the NUM sites. Results: A FHIR-compliant gICS-release and a corresponding consent template for the BC were provided to all NUM sites in June 2021. All FHIR functionalities comply with the already-balloted FHIR consent profiles of the HL7 Working Group Consent Management. The consent template simplifies the technical BC rollout and the corresponding implementation of the TFCI interoperability concept at the NUM sites. Conclusions: This article shows that a HL7 FHIR-compliant and interoperable nationwide exchange of consent information could be built using of the consent management software gICS and the provided TTP-FHIR Gateway. The initial functional scope of the solution covers the requirements identified in the NUM-CODEX setting. The semantic correctness of these functionalities was validated by project-partners from the Ludwig-Maximilian University in Munich. The production rollout of the solution package to all NUM sites has started successfully.
- 19 December 2022
- Published by Springer Nature in BMC Medical Informatics and Decision Making
- Vol. 22 (1) , 1-11
Open AccessA FHIR has been lit on gICS: facilitating the standardised exchange of informed consent in a large network of university medicine
Background: The Federal Ministry of Education and Research of Germany (BMBF) funds a network of university medicines (NUM) to support COVID-19 and pandemic research at national level. The “COVID-19 Data Exchange Platform” (CODEX) as part of NUM establishes a harmonised infrastructure that supports research use of COVID-19 datasets. The broad consent (BC) of the Medical Informatics Initiative (MII) is agreed by all German federal states and forms the legal base for data processing. All 34 participating university hospitals (NUM sites) work upon a harmonised infrastructural as well as legal basis for their data protection-compliant collection and transfer of their research dataset to the central CODEX platform. Each NUM site ensures that the exchanged consent information conforms to the already-balloted HL7 FHIR consent profiles and the interoperability concept of the MII Task Force “Consent Implementation” (TFCI). The Independent Trusted Third-Party (TTP) of the University Medicine Greifswald supports data protection-compliant data processing and provides the consent management solutions gICS. Methods: Based on a stakeholder dialogue a required set of FHIR-functionalities was identified and technically specified supported by official FHIR experts. Next, a “TTP-FHIR Gateway” for the HL7 FHIR-compliant exchange of consent information using gICS was implemented. A last step included external integration tests and the development of a pre-configured consent template for the BC for the NUM sites. Results: A FHIR-compliant gICS-release and a corresponding consent template for the BC were provided to all NUM sites in June 2021. All FHIR functionalities comply with the already-balloted FHIR consent profiles of the HL7 Working Group Consent Management. The consent template simplifies the technical BC rollout and the corresponding implementation of the TFCI interoperability concept at the NUM sites. Conclusions: This article shows that a HL7 FHIR-compliant and interoperable nationwide exchange of consent information could be built using of the consent management software gICS and the provided TTP-FHIR Gateway. The initial functional scope of the solution covers the requirements identified in the NUM-CODEX setting. The semantic correctness of these functionalities was validated by project-partners from the Ludwig-Maximilian University in Munich. The production rollout of the solution package to all NUM sites has started successfully.
- Open Access
- 29 July 2020
- Published by Springer Nature in Journal of Translational Medicine
- Vol. 18 (1) , 1-12
The generic Informed Consent Service gICS®: implementation and benefits of a modular consent software tool to master the challenge of electronic consent management in research
Background: Defining and protecting participants’ rights is the aim of several ethical codices and legal regulations. According to these regulations, the Informed Consent (IC) is an inevitable element of research with human subjects. In the era of “big data medicine”, aspects of IC become even more relevant since research becomes more complex rendering compliance with legal and ethical regulations increasingly difficult. Methods: Based on literature research and practical experiences gathered by the Institute for Community Medicine (ICM), University Medicine Greifswald, requirements for digital consent management systems were identified. Results: To address the requirements, the free-of-charge, open-source software “generic Informed Consent Service” (gICS®) was developed by ICM to provide a tool to facilitate and enhance usage of digital ICs for the international research community covering various scenarios. gICS facilitates IC management based on IC modularisation and supports various workflows within research, including (1) electronic depiction of paper-based consents and (2) fully electronic consents. Numerous projects applied gICS and documented over 336,000 ICs and 2400 withdrawals since 2014. Discussion: Since the consent’s content is a prerequisite for securing participants’ rights, application of gICS is no guarantee for legal compliance. However, gICS supports fine-granular consents and accommodation of differentiated consent states, which can be directly exchanged between systems, allowing automated data processing. Conclusion: gICS simplifies and supports sustained IC management as a major key to successfully conduct studies and build trust in research with human subjects. Therefore, interested researchers are invited to use gICS and provide feedback for further improvements.
- 29 July 2020
- Published by Springer Nature in Journal of Translational Medicine
- Vol. 18 (1) , 1-12
Open AccessThe generic Informed Consent Service gICS®: implementation and benefits of a modular consent software tool to master the challenge of electronic consent management in research
Background: Defining and protecting participants’ rights is the aim of several ethical codices and legal regulations. According to these regulations, the Informed Consent (IC) is an inevitable element of research with human subjects. In the era of “big data medicine”, aspects of IC become even more relevant since research becomes more complex rendering compliance with legal and ethical regulations increasingly difficult. Methods: Based on literature research and practical experiences gathered by the Institute for Community Medicine (ICM), University Medicine Greifswald, requirements for digital consent management systems were identified. Results: To address the requirements, the free-of-charge, open-source software “generic Informed Consent Service” (gICS®) was developed by ICM to provide a tool to facilitate and enhance usage of digital ICs for the international research community covering various scenarios. gICS facilitates IC management based on IC modularisation and supports various workflows within research, including (1) electronic depiction of paper-based consents and (2) fully electronic consents. Numerous projects applied gICS and documented over 336,000 ICs and 2400 withdrawals since 2014. Discussion: Since the consent’s content is a prerequisite for securing participants’ rights, application of gICS is no guarantee for legal compliance. However, gICS supports fine-granular consents and accommodation of differentiated consent states, which can be directly exchanged between systems, allowing automated data processing. Conclusion: gICS simplifies and supports sustained IC management as a major key to successfully conduct studies and build trust in research with human subjects. Therefore, interested researchers are invited to use gICS and provide feedback for further improvements.
- Open Access
- 14 September 2018
- Published by Springer Nature in Journal of Translational Medicine
- Vol. 16 (1) , 256
MAGIC: once upon a time in consent management—a FHIR® tale
The use of medical data for research purposes requires an informed consent of the patient that is compliant with the EU General Data Protection Regulation. In the context of multi-centre research initiatives and a multitude of clinical and epidemiological studies scalable and automatable measures for digital consent management are required. Modular form, structure, and contents render a patient’s consent reusable for varying project settings in order to effectively manage and minimise organisational and technical efforts. Within the DFG-funded project “MAGIC” (Grant Number HO 1937/5-1) the digital consent management service tool gICS was enhanced to comply with the recommendations published in the TMF data protection guideline for medical research. In addition, a structured exchange format for modular consent templates considering established standards and formats in the area of digital informed consent management was designed. Using the new FHIR standard and the HAPI FHIR library, the first version for an exchange format and necessary import-/export-functionalities were successfully implemented. The proposed exchange format is a “work in progress”. It represents a starting point for current discussions concerning digital consent management. It also attempts to improve interoperability between different approaches within the wider IHE-/HL7-/FHIR community. Independent of the exchange format, providing the possibility to export, modify and import templates for consents and withdrawals to be reused in similar clinical and epidemiological studies is an essential precondition for the sustainable operation of digital consent management.
- 14 September 2018
- Published by Springer Nature in Journal of Translational Medicine
- Vol. 16 (1) , 256
Open AccessMAGIC: once upon a time in consent management—a FHIR® tale
The use of medical data for research purposes requires an informed consent of the patient that is compliant with the EU General Data Protection Regulation. In the context of multi-centre research initiatives and a multitude of clinical and epidemiological studies scalable and automatable measures for digital consent management are required. Modular form, structure, and contents render a patient’s consent reusable for varying project settings in order to effectively manage and minimise organisational and technical efforts. Within the DFG-funded project “MAGIC” (Grant Number HO 1937/5-1) the digital consent management service tool gICS was enhanced to comply with the recommendations published in the TMF data protection guideline for medical research. In addition, a structured exchange format for modular consent templates considering established standards and formats in the area of digital informed consent management was designed. Using the new FHIR standard and the HAPI FHIR library, the first version for an exchange format and necessary import-/export-functionalities were successfully implemented. The proposed exchange format is a “work in progress”. It represents a starting point for current discussions concerning digital consent management. It also attempts to improve interoperability between different approaches within the wider IHE-/HL7-/FHIR community. Independent of the exchange format, providing the possibility to export, modify and import templates for consents and withdrawals to be reused in similar clinical and epidemiological studies is an essential precondition for the sustainable operation of digital consent management.