KHKazunori Harada

Kazunori Harada

*This is an algorithmically generated author record based on publicly available information.

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Kazunori Harada has a total of 29 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • A case of local recurrence of periductal stromal sarcoma of the breast

    by Kana Teramoto, Yasuro Doi, Kayo Yamamoto, Kaname Matsukawa, Hisaka Iwaihara, Rumi Motoshima, Noboru Takata, Ichiro Yoshinaka, Kazunori Harada

    症例は63歳女性.2012年,右乳房の発赤を伴う硬結を主訴に受診.葉状腫瘍と診断され腫瘍摘出術施行.術後病理結果は乳腺症であり経過観察.2年後,切除部位に同症状を認め再検査.超音波検査で右乳房A領域に広がり5 cmの地図状低エコー域を認めた.皮下脂肪層内にも低エコーが進展し,浸潤による限局性皮膚肥厚が示唆された.パワードプラで豊富な血流信号を認めた.2012年と異なる所見は,皮膚から大胸筋までの厚みが増したこと,病変が拡大し,境界が不明瞭化していることであり,臨床症状も加味すると炎症性乳癌も否定できない画像所見であった.右乳房切除術施行.病理所見では紡錘形腫瘍細胞が正常腺管の周囲に浸潤性に増殖する病理組織像を認めた.紡錘形腫瘍細胞は免疫組織化学染色でビメンチン,CD34に陽性を示し,periductal stromal sarcoma(PSS)と診断.初発時の切片を再評価すると,再発腫瘍と同様の腫瘍成分を認めた.PSSは報告例も少なく,臨床および画像上特徴的な所見も乏しく診断が困難とされる.初回手術では確定診断に至らず,局所再発をきたしたPSSの1例を経験したので,超音波画像所見を中心に報告する.

  • Open Access

    Efficacy of the projection onto convex sets (POCS) algorithm at Gd-EOB-DTPA-enhanced hepatobiliary-phase hepatic MRI

    by Shinichi Nakamura, Takeshi Nakaura, Masafumi Kidoh, Kazuo Awai, Tomohiro Namimoto, Ichiro Yoshinaka, Kazunori Harada, Yasuyuki Yamashita


  • Effects of a high-pitch protocol and a hybrid iterative reconstruction algorithm on image quality of cerebral subtracted 3D CT angiography

    by Yuji Iyama, Takeshi Nakaura, Masafumi Kidoh, Naoto Kiyota, Shouzaburou Uemura, Kazunori Harada, Yasuyuki Yamashita

    To evaluate the image quality and the radiation dose of 3D-computed tomography angiography (3D-CTA) with a high-pitch protocol and a hybrid iterative reconstruction (HIR). This was a prospective study and thirty patients were scanned at a 0.51-helical pitch with filtered back-projection (FBP, protocol-A), and 30 patients were scanned at a 0.91-helical pitch with FBP and HIR (protocol-B and C). The mean volume CT dose index (CTDIvol), image noise, and mean cerebral arterial and venous attenuation were compared between the three protocols. Two readers assessed image noise, arterial contrast and venous overlap. The mean CTDIvol of protocol-B/C (38.9 mGy) was lower than that of protocol-A (49.7 mGy). Mean image noise of protocol-B [12.6 ± 1.3 Hounsfield units (HU)] was higher than that of protocol-A (10.3 ± 1.2 HU). There was no significant difference in arterial attenuation between protocol-A (327.5 ± 57.5 HU) and C (327.7 ± 59.4 HU). Venous attenuation of protocol-C (148.5 ± 50.4 HU) was lower than that of protocol-A (185.9 ± 50.6 HU). In qualitative analysis, the image noise of protocol-B was higher than that of protocol-A/C. Venous enhancement of protocol-B/C was more inconspicuous than that of protocol-A. 3D-CTA with a high-pitch protocol and HIR can reduce radiation dose while decreasing venous enhancement and image noise to an adequate level for diagnosis.


  • Open Access

    Acute gastric volvulus in a patient with trisomy 21

    by Kota Arima, Daisuke Hashimoto, Noboru Takata, Yasuro Doi, Ichiro Yoshinaka, Kazunori Harada, Hideo Baba

    Acute gastric volvulus is a torsion of the stomach by more than 180° and a life-threatening condition. We present a 50-year-old male patient with acute abdominal pain who has Down syndrome/trisomy 21. Computed tomography showed a significant distended stomach with features of a severe gastric volvulus. Emergency operation in form of reduction and gastropexy was performed. We are not aware of any similar cases published in the English literature, where as gastric volvulus occurred in a patient with Down syndrome.


  • Open Access

    Single-breath-hold whole-heart coronary MRA in healthy volunteers at 3.0-T MRI

    by Yuji Iyama, Takeshi Nakaura, Masafumi Kidoh, Tetsuya Kawahara, Naritsugu Sakaino, Kazunori Harada, Tomoyuki Okuaki, Yasuyuki Yamashita

    The purpose of this study was to investigate the feasibility of single-breath-hold whole-heart MRA with a 3-T system. Ten healthy male volunteers underwent single-breath-hold whole-heart coronary MRA at 3 T. We assessed acquisition time, scores of image quality of coronary artery (RCA: proximal, middle and distal, LAD: main, proximal, middle and distal, LCX: proximal and distal) and the visualized vessel length of RCA, LAD and LCX. Mean acquisition time was 37.7 ± 5.2 sec. Coronary branch was successfully depicted in 67/80 branches (84%) in the 10 healthy volunteers with diagnostic image quality. And, the average visible RCA, LAD and LCX vessel length were 83.4 ± 22 mm and 59.6 ± 24 mm. 3-T MRI with single-breath-hold 3D whole-heart coronary MRA can yield adequate image quality. Further study is needed to evaluate the clinical benefit of this technique.


  • Timing of the hepatic arterial phase at Gd-EOB-DTPA-enhanced hepatic dynamic MRI: Comparison of the test-injection and the fixed-time delay method

    by Shinichi Nakamura, Takeshi Nakaura, Masafumi Kidoh, Daisuke Utsunomiya, Yasuro Doi, Kazunori Harada, Shozaburou Uemura, Yasuyuki Yamashita

    Purpose To compare the fixed‐time‐ and the test‐injection method with respect to the image quality of hypervascular hepatocellular carcinoma (HCC) and the adequacy of timing of the hepatic arterial phase (HAP) in Gd‐EOB‐DTPA (EOB) enhanced MRI. Materials and Methods We studied 63 patients with computed tomography (CT) ‐proven hypervascular HCC: 30 (group 1) were scanned HAP using the fixed‐time delay method (protocol 1); in the other 33 (group 2), we applied the test‐injection method (protocol 2). We compared the protocols with respect with tumor‐to‐liver contrast (TLC), contrast‐to‐noise‐ratio (CNR), and relative enhancement of the liver and tumor (REL, RET) during HAP. Two radiologists compared the adequacy of HAP, image contrast, image noise, and overall image quality. Results Under protocol 2, TLC, CNR, and REL and RET of hypervascular HCC were significantly higher (P < 0.01). The proportion of optimal HAP was significantly higher for protocol 2 than protocol 1 (P < 0.01). The visual score of the image contrast and the overall image quality were significantly higher in group 2 than group 1 (P = 0.02 and P = 0.01, respectively). Conclusion At EOB‐enhanced hepatic dynamic MRI, the test‐injection method yielded better image quality of hypervascular HCC and improved adequacy of timing of HAP. J. Magn. Reson. Imaging 2012;38:548–554.