Vladimir Timofeev
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Vladimir Timofeev has a total of 34 co-authors. Here are the top co-authors by number of shared publications:
Ekaterina Khailenko
2 shared publicationsNovosibirsk State Technical University
2 shared publicationsA. A. Studenikina
Novosibirsk State Medical University; Institute of Molecular Biology and Biophysics, Federal Research Center of Fundamental and Translational Medicine
1 shared publication- A. I. Autenschlyus
Novosibirsk State Medical University; Institute of Molecular Biology and Biophysics, Federal Research Center of Fundamental and Translational Medicine
1 shared publication A. V. Morgunov
Lomonosov State Academy of Fine Chemical Technology
1 shared publication- Alexander D. Sharonin
Federal Research Center for Fundamental and Translational Medicine, Novosibirsk
1 shared publication
Latest Publications
- Open Access
- 23 July 2026
- Published by Siberian State Medical University in Bulletin of Siberian Medicine
- Vol. 25 (2) , 91-100
The potential application of the random forest method to explore the association between microRNAs and tissue and molecular genetic biomarkers of breast cancer
Aim. Exploring the potential of using a random forest method (RFM) to identify associations between serum levels of microRNAs miR-181a and miR-25 and the expression of the following markers: E-cadherin (CDH1), type II collagen (CII), integrin beta-1 (ITGB1), cyclin D1 (CCND1), and T-lymphocyte costimulator (CD86), as well as their relationship with clinically relevant molecular genetic markers (ER, PR, HER2, Ki-67) in patients with breast cancer (BC). Materials and methods. We recruited 44 BC patients with invasive ductal carcinoma who had not received neoadjuvant treatment. Serum levels of miR-181a and miR-25 were measured using digital droplet PCR, and the expression of CDH1, CII, ITGB1, CCND1, CD86, ER, PR, HER2, and Ki-67 in tumor tissue samples was assessed via immunohistochemistry. Spearman’s correlation analysis and the RFM were applied to assess associations between variables. Results. Spearman’s correlation analysis did not reveal any significant linear relationships between the studied parameters ( p > 0.05). However, the RFM identified nonlinear associations: for miR-181a, the optimal predictive model included CDH1 and CCND1 (MAE = 4.267); for miR-25, ITGB1 and CCND1 (MAE = 16.255). Among clinical and pathological characteristics, statistically significant positive correlations were found between CII and ER ( r = 0.498; p = 0.001) and PR ( r = 0.354; p = 0.018). The RFM models demonstrated the highest accuracy in predicting the HER2 status (82.6%) when using a combination of ITGB1, miR-181a, and CDH1. Conclusion. The RFM revealed complex nonlinear associations between microRNAs and tissue markers of tumor progression that were not detected by conventional statistical methods. These findings are exploratory in nature and provide a foundation for further research aimed at validating these biomarkers and elucidating their role in the pathogenesis of various breast cancer subtypes.
- 23 July 2026
- Published by Siberian State Medical University in Bulletin of Siberian Medicine
- Vol. 25 (2) , 91-100
Open AccessThe potential application of the random forest method to explore the association between microRNAs and tissue and molecular genetic biomarkers of breast cancer
Aim. Exploring the potential of using a random forest method (RFM) to identify associations between serum levels of microRNAs miR-181a and miR-25 and the expression of the following markers: E-cadherin (CDH1), type II collagen (CII), integrin beta-1 (ITGB1), cyclin D1 (CCND1), and T-lymphocyte costimulator (CD86), as well as their relationship with clinically relevant molecular genetic markers (ER, PR, HER2, Ki-67) in patients with breast cancer (BC). Materials and methods. We recruited 44 BC patients with invasive ductal carcinoma who had not received neoadjuvant treatment. Serum levels of miR-181a and miR-25 were measured using digital droplet PCR, and the expression of CDH1, CII, ITGB1, CCND1, CD86, ER, PR, HER2, and Ki-67 in tumor tissue samples was assessed via immunohistochemistry. Spearman’s correlation analysis and the RFM were applied to assess associations between variables. Results. Spearman’s correlation analysis did not reveal any significant linear relationships between the studied parameters ( p > 0.05). However, the RFM identified nonlinear associations: for miR-181a, the optimal predictive model included CDH1 and CCND1 (MAE = 4.267); for miR-25, ITGB1 and CCND1 (MAE = 16.255). Among clinical and pathological characteristics, statistically significant positive correlations were found between CII and ER ( r = 0.498; p = 0.001) and PR ( r = 0.354; p = 0.018). The RFM models demonstrated the highest accuracy in predicting the HER2 status (82.6%) when using a combination of ITGB1, miR-181a, and CDH1. Conclusion. The RFM revealed complex nonlinear associations between microRNAs and tissue markers of tumor progression that were not detected by conventional statistical methods. These findings are exploratory in nature and provide a foundation for further research aimed at validating these biomarkers and elucidating their role in the pathogenesis of various breast cancer subtypes.
- Open Access
- 14 November 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (22) , 12110
Aerosol Spraying of Carbon Nanofiber-Based Films for NO2 Detection: The Role of the Spraying Technique
This study is devoted to the determination of the role of aerosol spraying in the formation of NO2 sensor properties of carbon nanofiber (CNF)-based films. This is the first paper to systematically apply the aerosol spraying technique to CNF-based films and link the spraying parameters directly to sensor performance metrics (response, signal-to-noise ratio, response times, etc.). Chemiresistive gas sensors were created based on CNFs and tested at room temperature (25 ± 1 °C). It has been shown that the increase in the concentration of the CNF/ethanol mixture used for spraying from 3 to 30 mg/mL led to a growth in sensor response from 1.2% to 12.0% at 2 ppm NO2. The increase in the thickness of the CNF film of the sensor induced a growth in ΔR/R0 to NO2 that is attributed to the formation of a porous film. With increased film thickness, the response improves (from 7.0% to 10.6% at 2 ppm NO2) as does the signal-to-noise ratio (from 735:1 to 1892:1). The creation of hybrid all-carbon composites based on CNFs and multi-walled carbon nanotubes (MWCNTs) resulted in a decrease in both sensor response and signal-to-noise ratio; however, the response time and recovery degree improved. Two types of hybrid materials based on CNFs and MWCNTs were created using aerosol spraying to enhance the sensor behavior of CNFs. The obtained data confirm the dominant role of the thickness of CNF-based films and their density (in terms of distance between nearest carbon inclusions within the film) in sensor characteristics. The machine learning data used to describe the sensing behavior of two gases with opposite resistance changes when in contact with CNFs, namely NO2 and NH3, showed final accuracies of 92.13% on training data and 91.98% on validation data.
- 14 November 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (22) , 12110
Open AccessAerosol Spraying of Carbon Nanofiber-Based Films for NO2 Detection: The Role of the Spraying Technique
This study is devoted to the determination of the role of aerosol spraying in the formation of NO2 sensor properties of carbon nanofiber (CNF)-based films. This is the first paper to systematically apply the aerosol spraying technique to CNF-based films and link the spraying parameters directly to sensor performance metrics (response, signal-to-noise ratio, response times, etc.). Chemiresistive gas sensors were created based on CNFs and tested at room temperature (25 ± 1 °C). It has been shown that the increase in the concentration of the CNF/ethanol mixture used for spraying from 3 to 30 mg/mL led to a growth in sensor response from 1.2% to 12.0% at 2 ppm NO2. The increase in the thickness of the CNF film of the sensor induced a growth in ΔR/R0 to NO2 that is attributed to the formation of a porous film. With increased film thickness, the response improves (from 7.0% to 10.6% at 2 ppm NO2) as does the signal-to-noise ratio (from 735:1 to 1892:1). The creation of hybrid all-carbon composites based on CNFs and multi-walled carbon nanotubes (MWCNTs) resulted in a decrease in both sensor response and signal-to-noise ratio; however, the response time and recovery degree improved. Two types of hybrid materials based on CNFs and MWCNTs were created using aerosol spraying to enhance the sensor behavior of CNFs. The obtained data confirm the dominant role of the thickness of CNF-based films and their density (in terms of distance between nearest carbon inclusions within the film) in sensor characteristics. The machine learning data used to describe the sensing behavior of two gases with opposite resistance changes when in contact with CNFs, namely NO2 and NH3, showed final accuracies of 92.13% on training data and 91.98% on validation data.
- Open Access
- 29 April 2025
- Published by Silicea - Poligraf, LLC in Russian Journal of Cardiology
- Vol. 30 (3) , 5869
Efficacy and safety of inclisiran, evolocumab and alirocumab in patients with high, very high and extreme cardiovascular risk
Aim. To compare efficacy and safety of inclisiran, evolocumab and alirocumab in patients with high, very high and extreme cardiovascular risk (according to data from the Federal Research Center for Cardiology and Microbiology, Novosibirsk).Material and methods. This prospective two-year observational comparative included 53 patients (43 men and 10 women) with an average age of 61,2±4,7 years. They were treated with alirocumab at a dose of 75 mg (n=9) and 150 mg (n=25), evolocumab 140 mg (n=10), and inclisiran (n=9). Two patients were diagnosed with definite familial hypercholesterolemia according to DLCN criteria, while five patients had a myocardial infarction. Lipid profile, transaminase, creatinine, and glucose levels were assessed after 3, 6, 12, and 24 months. The primary efficacy endpoint was achievement of target low-density lipoprotein (LDL) values. The secondary efficacy endpoint was recurrent cardiovascular events (myocardial infarction, stroke, urgent coronary and non-coronary artery revascularization, critical ischemia and lower extremity amputation). New cases of diabetes and atrial fibrillation were also monitored. Safety was assessed based on clinical data and laboratory parameters, such as transaminase, total bilirubin, creatinine and blood glucose levels. The follow-up period ranged from 6 months to 2 years.Results. Target LDL cholesterol levels for extreme cardiovascular risk were achieved in 21 of 32 patients, and for very high and high risk levels — in 16 of 21 patients. The average LDL level decreased from 3,71 to 1,47 mmol/L during the period of lipid-lowering therapy, while no differences were found between the treatment subgroups. During the two-year follow-up, no endpoints were observed in the study patients. High compliance and good tolerability of all types of treatment with no adverse reactions, including local ones, were noted. None of the patients discontinued therapy.Conclusion. This single-center study showed that therapy with a PCSK9 inhibitor and inclisiran was well tolerated, and LDL-C reduction was similar to that observed in randomized, placebo-controlled trials.
- 29 April 2025
- Published by Silicea - Poligraf, LLC in Russian Journal of Cardiology
- Vol. 30 (3) , 5869
Open AccessEfficacy and safety of inclisiran, evolocumab and alirocumab in patients with high, very high and extreme cardiovascular risk
Aim. To compare efficacy and safety of inclisiran, evolocumab and alirocumab in patients with high, very high and extreme cardiovascular risk (according to data from the Federal Research Center for Cardiology and Microbiology, Novosibirsk).Material and methods. This prospective two-year observational comparative included 53 patients (43 men and 10 women) with an average age of 61,2±4,7 years. They were treated with alirocumab at a dose of 75 mg (n=9) and 150 mg (n=25), evolocumab 140 mg (n=10), and inclisiran (n=9). Two patients were diagnosed with definite familial hypercholesterolemia according to DLCN criteria, while five patients had a myocardial infarction. Lipid profile, transaminase, creatinine, and glucose levels were assessed after 3, 6, 12, and 24 months. The primary efficacy endpoint was achievement of target low-density lipoprotein (LDL) values. The secondary efficacy endpoint was recurrent cardiovascular events (myocardial infarction, stroke, urgent coronary and non-coronary artery revascularization, critical ischemia and lower extremity amputation). New cases of diabetes and atrial fibrillation were also monitored. Safety was assessed based on clinical data and laboratory parameters, such as transaminase, total bilirubin, creatinine and blood glucose levels. The follow-up period ranged from 6 months to 2 years.Results. Target LDL cholesterol levels for extreme cardiovascular risk were achieved in 21 of 32 patients, and for very high and high risk levels — in 16 of 21 patients. The average LDL level decreased from 3,71 to 1,47 mmol/L during the period of lipid-lowering therapy, while no differences were found between the treatment subgroups. During the two-year follow-up, no endpoints were observed in the study patients. High compliance and good tolerability of all types of treatment with no adverse reactions, including local ones, were noted. None of the patients discontinued therapy.Conclusion. This single-center study showed that therapy with a PCSK9 inhibitor and inclisiran was well tolerated, and LDL-C reduction was similar to that observed in randomized, placebo-controlled trials.
- Open Access
- 1 January 2022
- Published by Euroasian Scientific and Industrial Chamber, Ltd. in Современные наукоемкие технологии (Modern High Technologies)
- No. №4 2022,p. 114-121
ON ESTIMATION OF PARAMETERS OF REGRESSION MODELS WITH THE USE OF WAVELETS
- 1 January 2022
- Published by Euroasian Scientific and Industrial Chamber, Ltd. in Современные наукоемкие технологии (Modern High Technologies)
- No. №4 2022,p. 114-121
Open AccessON ESTIMATION OF PARAMETERS OF REGRESSION MODELS WITH THE USE OF WAVELETS
- 1 November 2021
- Published by Pleiades Publishing Ltd in Journal of Applied and Industrial Mathematics
- Vol. 15 (4) , 670-678
A Robust Neural Network with Simple Architecture
Under consideration are the classification problem and application of simple neural networks for solving the problem. A robust modification of the error backpropagation algorithm is proposed and used for training neural networks. Some proposition is proved that allows us to construct the proposed modification with the Huber loss-function. In order to study the properties of the so-obtained neural network, a number of computational experiments are carried out. We consider various values of the outliers’ fraction, noise level, and training and test samples sizes. Inspection of the results shows that the proposed modification can significantly increase the classification accuracy and learning rate of a neural network when working with noisy data.
- 1 November 2021
- Published by Pleiades Publishing Ltd in Journal of Applied and Industrial Mathematics
- Vol. 15 (4) , 670-678
A Robust Neural Network with Simple Architecture
Under consideration are the classification problem and application of simple neural networks for solving the problem. A robust modification of the error backpropagation algorithm is proposed and used for training neural networks. Some proposition is proved that allows us to construct the proposed modification with the Huber loss-function. In order to study the properties of the so-obtained neural network, a number of computational experiments are carried out. We consider various values of the outliers’ fraction, noise level, and training and test samples sizes. Inspection of the results shows that the proposed modification can significantly increase the classification accuracy and learning rate of a neural network when working with noisy data.
- 18 June 2021
- Published by Novosibirsk State Technical University in Analysis and data processing systems
- No. 2
Building robust neural networks using different loss functions
The paper considers the problem of building robust neural networks using different robust loss functions. Applying such neural networks is reasonably when working with noisy data, and it can serve as an alternative to data preprocessing and to making neural network architecture more complex. In order to work adequately, the error back-propagation algorithm requires a loss function to be continuously or two-times differentiable. According to this requirement, two five robust loss functions were chosen (Andrews, Welsch, Huber, Ramsey and Fair). Using the above-mentioned functions in the error back-propagation algorithm instead of the quadratic one allows obtaining an entirely new class of neural networks. For investigating the properties of the built networks a number of computational experiments were carried out. Different values of outliers’ fraction and various numbers of epochs were considered. The first step included adjusting the obtained neural networks, which lead to choosing such values of internal loss function parameters that resulted in achieving the highest accuracy of a neural network. To determine the ranges of parameter values, a preliminary study was pursued. The results of the first stage allowed giving recommendations on choosing the best parameter values for each of the loss functions under study. The second stage dealt with comparing the investigated robust networks with each other and with the classical one. The analysis of the results shows that using the robust technique leads to a significant increase in neural network accuracy and in a learning rate.
- 18 June 2021
- Published by Novosibirsk State Technical University in Analysis and data processing systems
- No. 2
Building robust neural networks using different loss functions
The paper considers the problem of building robust neural networks using different robust loss functions. Applying such neural networks is reasonably when working with noisy data, and it can serve as an alternative to data preprocessing and to making neural network architecture more complex. In order to work adequately, the error back-propagation algorithm requires a loss function to be continuously or two-times differentiable. According to this requirement, two five robust loss functions were chosen (Andrews, Welsch, Huber, Ramsey and Fair). Using the above-mentioned functions in the error back-propagation algorithm instead of the quadratic one allows obtaining an entirely new class of neural networks. For investigating the properties of the built networks a number of computational experiments were carried out. Different values of outliers’ fraction and various numbers of epochs were considered. The first step included adjusting the obtained neural networks, which lead to choosing such values of internal loss function parameters that resulted in achieving the highest accuracy of a neural network. To determine the ranges of parameter values, a preliminary study was pursued. The results of the first stage allowed giving recommendations on choosing the best parameter values for each of the loss functions under study. The second stage dealt with comparing the investigated robust networks with each other and with the classical one. The analysis of the results shows that using the robust technique leads to a significant increase in neural network accuracy and in a learning rate.
- 20 December 2017
- Published by Novosibirsk State Technical University in Science Bulletin of the Novosibirsk State Technical University
- No. 4
Binary choice modeling based on stable distribution
- 20 December 2017
- Published by Novosibirsk State Technical University in Science Bulletin of the Novosibirsk State Technical University
- No. 4
Binary choice modeling based on stable distribution