Sylvie Coupaud
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Sylvie Coupaud has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
David B. Allan
Scottish Centre for Innovation in Spinal Cord Injury, Queen Elizabeth National Spinal Injuries Unit, Southern General Hospital, Glasgow G51 4TF, United Kingdom
2 shared publicationsKeisuke Sasagawa
Department of Engineering, Niigata Institute of Technology, 1719 Fujihashi, Kashiwazaki City, Niigata 945-1195, Japan
2 shared publicationsMariel Purcell
Scottish Centre for Innovation in Spinal Cord Injury, Queen Elizabeth National Spinal Injuries Unit, Queen Elizabeth University Hospital, Glasgow G51 4TF, UK
2 shared publicationsAlan N. McLean
Scottish Centre for Innovation in Spinal Cord Injury, Queen Elizabeth National Spinal Injuries Unit, Southern General Hospital, Glasgow G51 4TF, United Kingdom
1 shared publication- John S. Riddell
School of Psychology and Neuroscience, College of Medical, Veterinary and Life Sciences, University of Glasgow, Glasgow, G12 8QQ, United Kingdom
1 shared publication - Jonathan Anthony Williams
Centre for the Cellular Microenvironment, Department of Biomedical Engineering, University of Strathclyde, Glasgow, United Kingdom
1 shared publication
Latest Publications
- Open Access
Development and Preliminary Clinical Feasibility of a Wearable Nanovibration Delivery Device for Localised Bone Stimulation in Individuals with Spinal Cord Injury
Spinal cord injury (SCI) causes rapid and severe bone loss in the paralysed lower limbs, particularly at the distal femur and proximal tibia, where fragility fracture risk is high. In vitro nanoscale vibration at 1 kHz has been shown to promote osteogenic differentiation and inhibit osteoclastogenesis, suggesting potential as a targeted mechanical intervention. This study aimed to develop and evaluate a wearable device for delivering and monitoring localised nanovibration at the distal femur in individuals with SCI. The device delivered continuous sinusoidal nanoscale stimulation at 1 kHz via a bone-conduction transducer, with an opposing accelerometer used to monitor transmitted vibration in real time. Design and target-site selection were refined through two healthy-volunteer investigations comparing the distal femur, proximal tibia, and distal tibia. Bovine femur experiments characterised vibration transmission under controlled benchtop conditions. Preliminary repeated-use feasibility was assessed in one individual with motor-complete SCI. Healthy volunteer testing showed that although the ankle initially produced the highest transmitted amplitudes, these were highly variable, and positioning was inconsistent. Within the knee region, the distal femur provided the most practical and repeatable site for a wearable application. In bovine femur experiments, scanning laser vibrometry demonstrated measurable vibration on the condylar surface opposite the transducer, and depth-resolved measurements confirmed that nanoscale vibration remained detectable within bone. A gel interface layer reduced the transmitted amplitude. In the feasibility evaluation, 61 sessions were completed over 14 weeks, with logged accelerometry confirming repeated nanoscale vibration transmission. These findings establish feasibility and support further device optimisation and translational studies.
Open AccessDevelopment and Preliminary Clinical Feasibility of a Wearable Nanovibration Delivery Device for Localised Bone Stimulation in Individuals with Spinal Cord Injury
Spinal cord injury (SCI) causes rapid and severe bone loss in the paralysed lower limbs, particularly at the distal femur and proximal tibia, where fragility fracture risk is high. In vitro nanoscale vibration at 1 kHz has been shown to promote osteogenic differentiation and inhibit osteoclastogenesis, suggesting potential as a targeted mechanical intervention. This study aimed to develop and evaluate a wearable device for delivering and monitoring localised nanovibration at the distal femur in individuals with SCI. The device delivered continuous sinusoidal nanoscale stimulation at 1 kHz via a bone-conduction transducer, with an opposing accelerometer used to monitor transmitted vibration in real time. Design and target-site selection were refined through two healthy-volunteer investigations comparing the distal femur, proximal tibia, and distal tibia. Bovine femur experiments characterised vibration transmission under controlled benchtop conditions. Preliminary repeated-use feasibility was assessed in one individual with motor-complete SCI. Healthy volunteer testing showed that although the ankle initially produced the highest transmitted amplitudes, these were highly variable, and positioning was inconsistent. Within the knee region, the distal femur provided the most practical and repeatable site for a wearable application. In bovine femur experiments, scanning laser vibrometry demonstrated measurable vibration on the condylar surface opposite the transducer, and depth-resolved measurements confirmed that nanoscale vibration remained detectable within bone. A gel interface layer reduced the transmitted amplitude. In the feasibility evaluation, 61 sessions were completed over 14 weeks, with logged accelerometry confirming repeated nanoscale vibration transmission. These findings establish feasibility and support further device optimisation and translational studies.
- 1 July 2012
- Published by Elsevier in Journal of Biomechanics
- Vol. 45, S549
A FINITE ELEMENT MODEL FOR THE TIBIA OF A SPINAL CORD INJURED PATIENT
- 1 July 2012
- Published by Elsevier in Journal of Biomechanics
- Vol. 45, S549
A FINITE ELEMENT MODEL FOR THE TIBIA OF A SPINAL CORD INJURED PATIENT