D. Iturbe
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
D. Iturbe has a total of 3 co-authors. Here are the top co-authors by number of shared publications:
- Ana Urkiaga
GAIKER Technology Centre
2 shared publications - Javier Etxebarria
GAIKER Technology Centre, Zamudio, Spain
2 shared publications - Eneko Agirre
HiTZ Center University of the Basque Country (UPV/EHU)
1 shared publication
Latest Publications
- Open Access
- 22 January 2015
- Published by Elsevier in Desalination and Water Treatment
- Vol. 56 (13) , 3415-3426
Effect of different additives on the fabrication of hydrophilic polysulfone ultrafiltration membranes
Polysulfone ultrafiltration membranes have been widely applied, especially for water and wastewater treatment. Polysulfone as membrane material presents several advantages, such as good mechanical properties, high thermal and chemical resistance, processing easiness, and wide availability in the market. However, the hydrophobic nature of the polysulfone membrane leads to a low water flux and increases the proneness to organic fouling. In order to overcome this problem, the effect of different additives and polymer concentration on the performance and morphology of polysulfone flat sheet membranes, prepared by phase inversion process, were investigated in this work. Several experimental sets were performed. The effect of polyvinylpyrrolidone to increase the pore density and membrane permeability was confirmed. Moreover, the effect of lithium chloride to reduce the amount of macrovoids in the membrane and to increase the viscosity of the casting solution was also confirmed. The fabricated membranes were characterized by atomic force microscopy, scanning electron microscopy, and infrared spectroscopy (ATR-IR). Furthermore, water permeability, retention tests to evaluate the molecular weight cut-off, and the real thickness of the prepared membranes as well as viscosity of the casting solutions were measured.
- 22 January 2015
- Published by Elsevier in Desalination and Water Treatment
- Vol. 56 (13) , 3415-3426
Open AccessEffect of different additives on the fabrication of hydrophilic polysulfone ultrafiltration membranes
Polysulfone ultrafiltration membranes have been widely applied, especially for water and wastewater treatment. Polysulfone as membrane material presents several advantages, such as good mechanical properties, high thermal and chemical resistance, processing easiness, and wide availability in the market. However, the hydrophobic nature of the polysulfone membrane leads to a low water flux and increases the proneness to organic fouling. In order to overcome this problem, the effect of different additives and polymer concentration on the performance and morphology of polysulfone flat sheet membranes, prepared by phase inversion process, were investigated in this work. Several experimental sets were performed. The effect of polyvinylpyrrolidone to increase the pore density and membrane permeability was confirmed. Moreover, the effect of lithium chloride to reduce the amount of macrovoids in the membrane and to increase the viscosity of the casting solution was also confirmed. The fabricated membranes were characterized by atomic force microscopy, scanning electron microscopy, and infrared spectroscopy (ATR-IR). Furthermore, water permeability, retention tests to evaluate the molecular weight cut-off, and the real thickness of the prepared membranes as well as viscosity of the casting solutions were measured.
- Open Access
- 22 January 2015
- Published by Elsevier in Desalination and Water Treatment
- Vol. 56 (13) , 3568-3575
Study of the influence of different variables on membrane fouling in submerged membrane bioreactors
Membrane fouling is still the greatest handicap to overcome in membrane bioreactor (MBR) technology. In this study, a multi-factorial experimental design was carried out in order to optimize the MBR process, studying the effect of major variables involved in the fouling phenomenon as well as the interaction between them. To that end, a submerged membrane bioreactor was operated at three different levels of: sludge retention time (SRT) [25 and 60 d], mixed liquor suspended solids (MLSS) [6 and 14 g/L], and ratio between soluble and particulate chemical oxygen demand (sCOD/pCOD) [1 and 4] in the wastewater. The concentration of extracellular polymeric substances (EPS), as one of the most relevant factor responsible for membrane fouling, and the permeate flux were measured. After an exhaustive statistical analysis, it was confirmed that there is a relationship between the concentration of EPS and membrane fouling. It also appears that the ratio sCOD/pCOD in the composition of the wastewater plays a very important role in the fouling which becomes less pronounced as the soluble fraction increases. Moreover, high fouling potential was observed at high SRT values. Finally, it was proved that the membrane fouling was slightly less pronounced at higher MLSS concentration.
- 22 January 2015
- Published by Elsevier in Desalination and Water Treatment
- Vol. 56 (13) , 3568-3575
Open AccessStudy of the influence of different variables on membrane fouling in submerged membrane bioreactors
Membrane fouling is still the greatest handicap to overcome in membrane bioreactor (MBR) technology. In this study, a multi-factorial experimental design was carried out in order to optimize the MBR process, studying the effect of major variables involved in the fouling phenomenon as well as the interaction between them. To that end, a submerged membrane bioreactor was operated at three different levels of: sludge retention time (SRT) [25 and 60 d], mixed liquor suspended solids (MLSS) [6 and 14 g/L], and ratio between soluble and particulate chemical oxygen demand (sCOD/pCOD) [1 and 4] in the wastewater. The concentration of extracellular polymeric substances (EPS), as one of the most relevant factor responsible for membrane fouling, and the permeate flux were measured. After an exhaustive statistical analysis, it was confirmed that there is a relationship between the concentration of EPS and membrane fouling. It also appears that the ratio sCOD/pCOD in the composition of the wastewater plays a very important role in the fouling which becomes less pronounced as the soluble fraction increases. Moreover, high fouling potential was observed at high SRT values. Finally, it was proved that the membrane fouling was slightly less pronounced at higher MLSS concentration.