Gerke Veenstra
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Gerke Veenstra has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Evert Christiaan Boerma
Faculty Campus Fryslân, University of Groningen, Leeuwarden, The Netherlands
2 shared publications B. Scheenstra
Medical Centre Leeuwarden, ICU, Leeuwarden, The Netherlands
1 shared publication- Can Ince
Department of Translational Physiology, Academic Medical Center, University of Amsterdam, Meibergdreef 9, 1105 AZ Amsterdam, The Netherlands
1 shared publication - Can Ince
The Department of Intensive Care, Laboratory of Emeregency, Perioperative and Intensive Care (EPIC lab), Erasmus MC, University Medical Center, Rotterdam, The Netherlands
1 shared publication - Claudia Scorcella
Anesthesia and Intensive Care Unit, Department of Biomedical Sciences and Public Health, Università Politecnica delle Marche, via Tronto 10/a, 60126, Ancona, Italy
1 shared publication E.C. Boerma
Medical Centre Leeuwarden, ICU, Leeuwarden, The Netherlands
1 shared publication
Latest Publications
- Top Cited PapersOpen Access
- 31 January 2015
- Published by Springer Nature in Intensive Care Medicine Experimental
- Vol. 3 (1) , 1-10
Cytocam-IDF (incident dark field illumination) imaging for bedside monitoring of the microcirculation
Background: Orthogonal polarized spectral (OPS) and sidestream dark field (SDF) imaging video microscope devices were introduced for observation of the microcirculation but, due to technical limitations, have remained as research tools. Recently, a novel handheld microscope based on incident dark field illumination (IDF) has been introduced for clinical use. The Cytocam-IDF imaging device consists of a pen-like probe incorporating IDF illumination with a set of high-resolution lenses projecting images on to a computer controlled image sensor synchronized with very short pulsed illumination light. This study was performed to validate Cytocam-IDF imaging by comparison to SDF imaging in volunteers. Methods: This study is a prospective, observational study. The subjects consist of 25 volunteers. Results: Sublingual microcirculation was evaluated using both techniques. The main result was that Cytocam-IDF imaging provided better quality images and was able to detect 30% more capillaries than SDF imaging (total vessels density Cytocam-IDF: 21.60 ± 4.30 mm/mm2 vs SDF: 16.35 ± 2.78 mm/mm2, p < 0.0001). Comparison of the images showed increased contrast, sharpness, and image quality of both venules and capillaries. Conclusions: Cytocam-IDF imaging detected more capillaries and provided better image quality than SDF imaging. It is concluded that Cytocam-IDF imaging may provide a new improved imaging modality for clinical assessment of microcirculatory alterations.
- 31 January 2015
- Published by Springer Nature in Intensive Care Medicine Experimental
- Vol. 3 (1) , 1-10
Top Cited PapersOpen AccessCytocam-IDF (incident dark field illumination) imaging for bedside monitoring of the microcirculation
Background: Orthogonal polarized spectral (OPS) and sidestream dark field (SDF) imaging video microscope devices were introduced for observation of the microcirculation but, due to technical limitations, have remained as research tools. Recently, a novel handheld microscope based on incident dark field illumination (IDF) has been introduced for clinical use. The Cytocam-IDF imaging device consists of a pen-like probe incorporating IDF illumination with a set of high-resolution lenses projecting images on to a computer controlled image sensor synchronized with very short pulsed illumination light. This study was performed to validate Cytocam-IDF imaging by comparison to SDF imaging in volunteers. Methods: This study is a prospective, observational study. The subjects consist of 25 volunteers. Results: Sublingual microcirculation was evaluated using both techniques. The main result was that Cytocam-IDF imaging provided better quality images and was able to detect 30% more capillaries than SDF imaging (total vessels density Cytocam-IDF: 21.60 ± 4.30 mm/mm2 vs SDF: 16.35 ± 2.78 mm/mm2, p < 0.0001). Comparison of the images showed increased contrast, sharpness, and image quality of both venules and capillaries. Conclusions: Cytocam-IDF imaging detected more capillaries and provided better image quality than SDF imaging. It is concluded that Cytocam-IDF imaging may provide a new improved imaging modality for clinical assessment of microcirculatory alterations.
- 1 September 2014
- Published by Elsevier in Best Practice & Research Clinical Anaesthesiology
- Vol. 28 (3) , 217-226
Direct markers of organ perfusion to guide fluid therapy: When to start, when to stop
- 1 September 2014
- Published by Elsevier in Best Practice & Research Clinical Anaesthesiology
- Vol. 28 (3) , 217-226
Direct markers of organ perfusion to guide fluid therapy: When to start, when to stop
- Open Access
- 1 August 2014
- Published by Elsevier in Journal of Critical Care
- Vol. 29 (4) , 478-481
Microcirculatory perfusion derangements during continuous hemofiltration with fixed dose of ultrafiltration in stabilized intensive care unit patients
- 1 August 2014
- Published by Elsevier in Journal of Critical Care
- Vol. 29 (4) , 478-481
Open AccessMicrocirculatory perfusion derangements during continuous hemofiltration with fixed dose of ultrafiltration in stabilized intensive care unit patients