S. Ganesan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
S. Ganesan has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
- Prakasarao Aruna
Department of Medical Physics, Anna University, Chennai, India
5 shared publications D Manigandan
2 shared publicationsD. Koteeswaran
Department of Oral Medicine and Radiology, Meenakshi Ammal Dental College and Hospital, Chennai, India
2 shared publicationsG Rath
2 shared publicationsS Sharma
2 shared publicationsV Subramani
2 shared publications
Latest Publications
- 13 January 2015
- Published by Taylor & Francis in International Journal of Polymeric Materials and Polymeric Biomaterials
- Vol. 64 (10) , 519-525
Influence of Anionic Surface Charged Biocompatible Dendrimer With a Photosensitizer, Protoporphyrin IX, on Human Red Blood Cells: A Spectroscopic Investigation
A biocompatible anionic dendrimer with carboxylic acid and phenolic hydroxyl functional groups at the surface of every half and full generations was designed by condensing phloroglucinol and succinic acid and its hemolytic effect on red blood cells was studied. The study reveals that the anionic surface charged dendrimer exhibits hemocompatibility and satisfies the reduction of dark toxicity of photosensitizer when loaded inside the nanocarrier, one of the prime requirements for a drug delivery system in photodynamic therapy applications. GRAPHICAL ABSTRACT
- 13 January 2015
- Published by Taylor & Francis in International Journal of Polymeric Materials and Polymeric Biomaterials
- Vol. 64 (10) , 519-525
Influence of Anionic Surface Charged Biocompatible Dendrimer With a Photosensitizer, Protoporphyrin IX, on Human Red Blood Cells: A Spectroscopic Investigation
A biocompatible anionic dendrimer with carboxylic acid and phenolic hydroxyl functional groups at the surface of every half and full generations was designed by condensing phloroglucinol and succinic acid and its hemolytic effect on red blood cells was studied. The study reveals that the anionic surface charged dendrimer exhibits hemocompatibility and satisfies the reduction of dark toxicity of photosensitizer when loaded inside the nanocarrier, one of the prime requirements for a drug delivery system in photodynamic therapy applications. GRAPHICAL ABSTRACT
- 1 June 2011
- Published by Wiley in Medical Physics
- Vol. 38 (6Part13) , 3532
SU‐E‐T‐198: Evaluation of Dosimetric Characteristics of MOSFET Dosimeter for the Quality Assurance of Photon and Electron Beams
- 1 June 2011
- Published by Wiley in Medical Physics
- Vol. 38 (6Part13) , 3532
SU‐E‐T‐198: Evaluation of Dosimetric Characteristics of MOSFET Dosimeter for the Quality Assurance of Photon and Electron Beams
- 2 June 2010
- Published by Wiley in Medical Physics
- Vol. 37 (6Part20) , 3257
SU‐GG‐T‐310: Dose Perturbation Caused by MOSFET Dosimeter during in Vivo Dosimetry of Photon and Electron Beam Radiotherapy ‐ a Film Dosimetry Study
- 2 June 2010
- Published by Wiley in Medical Physics
- Vol. 37 (6Part20) , 3257
SU‐GG‐T‐310: Dose Perturbation Caused by MOSFET Dosimeter during in Vivo Dosimetry of Photon and Electron Beam Radiotherapy ‐ a Film Dosimetry Study
- 11 February 2010
- Published by SPIE-Intl Soc Optical Eng
- Vol. 7561
Diffuse reflectance spectroscopy of pre- and post-treated oral submucous fibrosis: an in vivo study
Oral submucous fibrosis (OSF) is a high risk precancerous condition characterized by changes in the connective tissue fibers of the lamina propria and deeper parts leading to stiffness of the mucosa and restricted mouth opening, fibrosis of the lining mucosa of the upper digestive tract involving the oral cavity, oro- and hypo-pharynx and the upper two-thirds of the oesophagus. Optical reflectance measurements have been used to extract diagnostic information from a variety of tissue types, in vivo. We apply diffuse reflectance spectroscopy to quantitatively monitor tumour response to chemotherapy. Twenty patients with submucous fibrosis were diagnosed with diffuse reflectance spectroscopy and treated with the chemotherapy drug, Dexamethasone sodium phosphate and Hyaluronidase injection for seven weeks and after the treatment they were again subjected to the diffuse reflectance spectroscopy. The major observed spectral alterations on pre and post treated submucous fibrosis is an increase in the diffuse reflectance from 450 to 600 nm. Normal mucosa has showed higher reflectance when compared to the pre and post-treated cases. The spectral changes were quantified and correlated to conventional diagnostic results viz., maximum mouth opening, tongue protrusion and burning sensation. The results of this study suggest that the diffuse reflectance spectroscopy may also be considered as complementary optical techniques to monitor oral tissue transformation.
- 11 February 2010
- Published by SPIE-Intl Soc Optical Eng
- Vol. 7561
Diffuse reflectance spectroscopy of pre- and post-treated oral submucous fibrosis: an in vivo study
Oral submucous fibrosis (OSF) is a high risk precancerous condition characterized by changes in the connective tissue fibers of the lamina propria and deeper parts leading to stiffness of the mucosa and restricted mouth opening, fibrosis of the lining mucosa of the upper digestive tract involving the oral cavity, oro- and hypo-pharynx and the upper two-thirds of the oesophagus. Optical reflectance measurements have been used to extract diagnostic information from a variety of tissue types, in vivo. We apply diffuse reflectance spectroscopy to quantitatively monitor tumour response to chemotherapy. Twenty patients with submucous fibrosis were diagnosed with diffuse reflectance spectroscopy and treated with the chemotherapy drug, Dexamethasone sodium phosphate and Hyaluronidase injection for seven weeks and after the treatment they were again subjected to the diffuse reflectance spectroscopy. The major observed spectral alterations on pre and post treated submucous fibrosis is an increase in the diffuse reflectance from 450 to 600 nm. Normal mucosa has showed higher reflectance when compared to the pre and post-treated cases. The spectral changes were quantified and correlated to conventional diagnostic results viz., maximum mouth opening, tongue protrusion and burning sensation. The results of this study suggest that the diffuse reflectance spectroscopy may also be considered as complementary optical techniques to monitor oral tissue transformation.
- 1 January 2010
- Published by SPIE-Intl Soc Optical Eng
Synthesis and optical limiting characteristics of HAP@SiO
- 1 January 2010
- Published by SPIE-Intl Soc Optical Eng
Synthesis and optical limiting characteristics of HAP@SiO
- 29 December 2006
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 52 (2) , 525-537
Dose distribution for endovascular brachytherapy using Ir-192 sources: comparison of Monte Carlo calculations with radiochromic film measurements
An analysis of Ir-192 source distribution using the Monte Carlo method and radiochromic film experiments for endovascular brachytherapy is presented. Three different source possibilities, namely, mHDR Ir-192 sources with 5 mm and 2.5 mm step sizes and Ir-192 seed sources with 1 mm air gap are investigated to obtain uniform radial dose distribution throughout the treatment area. From this study, it is inferred that mHDR Ir-192 sources with 2.5 mm step size are effective for getting dose uniformity. Hence, different restenosis geometries, namely, linear, dumb bell and hairpin, are simulated with 2.5 mm step size, 15 mHDR Ir-192 sources using the Monte Carlo technique and the results are compared experimentally by using radiochromic films. The results from both methods agreed to within 7%. Further, it is also inferred that for the dosimetry of endovascular brachytherapy, the film dosimetry may be considered adequate, even if the film calibration is time consuming and requires adequate dosimetric procedures.
- 29 December 2006
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 52 (2) , 525-537
Dose distribution for endovascular brachytherapy using Ir-192 sources: comparison of Monte Carlo calculations with radiochromic film measurements
An analysis of Ir-192 source distribution using the Monte Carlo method and radiochromic film experiments for endovascular brachytherapy is presented. Three different source possibilities, namely, mHDR Ir-192 sources with 5 mm and 2.5 mm step sizes and Ir-192 seed sources with 1 mm air gap are investigated to obtain uniform radial dose distribution throughout the treatment area. From this study, it is inferred that mHDR Ir-192 sources with 2.5 mm step size are effective for getting dose uniformity. Hence, different restenosis geometries, namely, linear, dumb bell and hairpin, are simulated with 2.5 mm step size, 15 mHDR Ir-192 sources using the Monte Carlo technique and the results are compared experimentally by using radiochromic films. The results from both methods agreed to within 7%. Further, it is also inferred that for the dosimetry of endovascular brachytherapy, the film dosimetry may be considered adequate, even if the film calibration is time consuming and requires adequate dosimetric procedures.