Sherri M. Jones
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Sherri M. Jones has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
Jessica Pierce
Department of Communication Sciences and Disorders, East Carolina University, Greenville, NC, USA
2 shared publications- Sarath Vijayakumar
Department of Biomedical Sciences, School of Medicine, Creighton University, Omaha, NE 68178, USA
2 shared publications - Timothy A. Jones
University of Nebraska-Lincoln, Department of Special Education and Communication Disorders, Lincoln, NE 68583-0738 USA
2 shared publications Alyson K. Butler
*Department of Communication Sciences and Disorders, East Carolina University, Greenville, North Carolina, USA
1 shared publication- Andrew Stuart
Department of Communication Sciences and Disorders, East Carolina University, Greenville, North Carolina
1 shared publication - Bruce E. Mock
Department of Communication Sciences and Disorders, East Carolina University, Greenville, NC, USA
1 shared publication
Latest Publications
- 1 July 2016
- Published by Elsevier in Neurobiology of Aging
- Vol. 43, 13-22
Differential effects of Cdh23 753A on auditory and vestibular functional aging in C57BL/6J mice
- 1 July 2016
- Published by Elsevier in Neurobiology of Aging
- Vol. 43, 13-22
Differential effects of Cdh23 753A on auditory and vestibular functional aging in C57BL/6J mice
- 3 February 2015
- Published by Springer Nature in Mammalian Genome
- Vol. 26 (3-4) , 154-172
Vestibular dysfunction, altered macular structure and trait localization in A/J inbred mice
A/J mice develop progressive hearing loss that begins before 1 month of age and is attributed to cochlear hair cell degeneration. Screening tests indicated that this strain also develops early onset vestibular dysfunction and has otoconial deficits. The purpose of this study was to characterize the vestibular dysfunction and macular structural pathology over the lifespan of A/J mice. Vestibular function was measured using linear vestibular evoked potentials (VsEPs). Macular structural pathology was evaluated using light microscopy, scanning electron microscopy, transmission electron microscopy, confocal microscopy and Western blotting. Individually, vestibular functional deficits in mice ranged from mild to profound. On average, A/J mice had significantly reduced vestibular sensitivity (elevated VsEP response thresholds and smaller amplitudes), whereas VsEP onset latency was prolonged compared to age-matched controls (C57BL/6). A limited age-related vestibular functional loss was also present. Structural analysis identified marked age-independent otoconial abnormalities in concert with some stereociliary bundle defects. Macular epithelia were incompletely covered by otoconial membranes with significantly reduced opacity and often contained abnormally large or giant otoconia as well as normal-appearing otoconia. Elevated expression of key otoconins (i.e., otoconin 90, otolin and keratin sulfate proteoglycan) ruled out the possibility of reduced levels contributing to otoconial dysgenesis. The phenotype of A/J was partially replicated in a consomic mouse strain (C57BL/6J-Chr 17A/J/NaJ), thus indicating that Chr 17A/J contained a trait locus for a new gene variant responsible to some extent for the A/J vestibular phenotype. Quantitative trait locus analysis identified additional epistatic influences associated with chromosomes 1, 4, 9 and X. Results indicate that the A/J phenotype represents a complex trait, and the A/J mouse strain presents a new model for the study of mechanisms underlying otoconial formation and maintenance.
- 3 February 2015
- Published by Springer Nature in Mammalian Genome
- Vol. 26 (3-4) , 154-172
Vestibular dysfunction, altered macular structure and trait localization in A/J inbred mice
A/J mice develop progressive hearing loss that begins before 1 month of age and is attributed to cochlear hair cell degeneration. Screening tests indicated that this strain also develops early onset vestibular dysfunction and has otoconial deficits. The purpose of this study was to characterize the vestibular dysfunction and macular structural pathology over the lifespan of A/J mice. Vestibular function was measured using linear vestibular evoked potentials (VsEPs). Macular structural pathology was evaluated using light microscopy, scanning electron microscopy, transmission electron microscopy, confocal microscopy and Western blotting. Individually, vestibular functional deficits in mice ranged from mild to profound. On average, A/J mice had significantly reduced vestibular sensitivity (elevated VsEP response thresholds and smaller amplitudes), whereas VsEP onset latency was prolonged compared to age-matched controls (C57BL/6). A limited age-related vestibular functional loss was also present. Structural analysis identified marked age-independent otoconial abnormalities in concert with some stereociliary bundle defects. Macular epithelia were incompletely covered by otoconial membranes with significantly reduced opacity and often contained abnormally large or giant otoconia as well as normal-appearing otoconia. Elevated expression of key otoconins (i.e., otoconin 90, otolin and keratin sulfate proteoglycan) ruled out the possibility of reduced levels contributing to otoconial dysgenesis. The phenotype of A/J was partially replicated in a consomic mouse strain (C57BL/6J-Chr 17A/J/NaJ), thus indicating that Chr 17A/J contained a trait locus for a new gene variant responsible to some extent for the A/J vestibular phenotype. Quantitative trait locus analysis identified additional epistatic influences associated with chromosomes 1, 4, 9 and X. Results indicate that the A/J phenotype represents a complex trait, and the A/J mouse strain presents a new model for the study of mechanisms underlying otoconial formation and maintenance.
- 4 March 2013
- Published by Taylor & Francis in International Journal of Audiology
- Vol. 52 (6) , 413-418
Real-ear output measures of ear level fluency devices
The purpose of this study was to measure real-ear aided and saturated responses of SpeechEasy™ devices and compare responses while devices delivered altered auditory feedback (AAF) and non-altered feedback (NAF). A repeated measures quasi-experimental design was employed. Ten people fitted with completely-in-the-canal or open fit behind-the-ear devices participated. Probe microphone measures were obtained with speech, and 17 chirp stimuli presented at 75 dB and 85 dB SPL, respectively. Measurements were compared with devices delivering AAF (i.e. delayed and frequency shifted) versus NAF. Maximum outputs were approximately 100-105 dB SPL in the 2000-4000 Hz range. Statistically significant differences in device SPL output as a function of device setting (AAF vs. NAF) were found for seven chirp stimuli (p <.05) when levels were sampled at points that were not temporally aligned with the output chirps but not for speech stimulus (p = .17). Device output varied across individuals and with open fit devices dominated by ear canal resonance effects. Real-ear aided responses were equivalent with speech input when devices delivered AAF and NAF. Real-ear saturated responses were not, however, comparable between AAF and NAF settings and may be underestimated if AAF delay is not accounted for.
- 4 March 2013
- Published by Taylor & Francis in International Journal of Audiology
- Vol. 52 (6) , 413-418
Real-ear output measures of ear level fluency devices
The purpose of this study was to measure real-ear aided and saturated responses of SpeechEasy™ devices and compare responses while devices delivered altered auditory feedback (AAF) and non-altered feedback (NAF). A repeated measures quasi-experimental design was employed. Ten people fitted with completely-in-the-canal or open fit behind-the-ear devices participated. Probe microphone measures were obtained with speech, and 17 chirp stimuli presented at 75 dB and 85 dB SPL, respectively. Measurements were compared with devices delivering AAF (i.e. delayed and frequency shifted) versus NAF. Maximum outputs were approximately 100-105 dB SPL in the 2000-4000 Hz range. Statistically significant differences in device SPL output as a function of device setting (AAF vs. NAF) were found for seven chirp stimuli (p <.05) when levels were sampled at points that were not temporally aligned with the output chirps but not for speech stimulus (p = .17). Device output varied across individuals and with open fit devices dominated by ear canal resonance effects. Real-ear aided responses were equivalent with speech input when devices delivered AAF and NAF. Real-ear saturated responses were not, however, comparable between AAF and NAF settings and may be underestimated if AAF delay is not accounted for.