Hunter B. Gilbert
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Hunter B. Gilbert has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Robert J. Webster
Vanderbilt University
4 shared publications - Philip J. Swaney
Department of Mechanical Engineering, Vanderbilt University, Nashville, TN 37212
2 shared publications - Daniel Caleb Rucker
Department of Mechanical, Aerospace, and Biomedical Engineering, The University of Tennessee, Knoxville, TN, USA
1 shared publication - Jessica Burgner-Kahrs
University of Toronto
1 shared publication - Joseph S. Neimat
Department of Neurosurgery, Vanderbilt University, 1211 22nd Ave. S, Nashville, TN 37232, United States
1 shared publication - Peter A. York
Department of Engineering and Applied Sciences, Harvard University, Cambridge, MA USA
1 shared publication
Latest Publications
- 23 April 2016
- Published by Springer Nature
- p. 253-269
Concentric Tube Robots: The State of the Art and Future Directions
- 23 April 2016
- Published by Springer Nature
- p. 253-269
Concentric Tube Robots: The State of the Art and Future Directions
- 17 December 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Robotics
- Vol. 32 (1) , 20-35
Elastic Stability of Concentric Tube Robots: A Stability Measure and Design Test
Concentric tube robots are needle-sized manipulators which have been investigated for use in minimally invasive surgeries. It was noted early in the development of these devices that elastic energy storage can lead to a rapid snapping motion for designs with moderate to high tube curvatures. Substantial progress has recently been made in the concentric tube robot community in designing snap-free robots, planning stable paths, and characterizing conditions that result in snapping for specific classes of concentric tube robots. However, a general measure for determining the stability of a given robot configuration has yet to be proposed. In this paper, we use bifurcation and elastic stability theory to provide such a measure, as well as to produce a test for determining whether a given design is snap-free (i.e., whether snapping can occur anywhere in the unloaded robot's workspace). These results are useful in designing, planning motions for, and controlling concentric tube robots with high curvatures.
- 17 December 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Robotics
- Vol. 32 (1) , 20-35
Elastic Stability of Concentric Tube Robots: A Stability Measure and Design Test
Concentric tube robots are needle-sized manipulators which have been investigated for use in minimally invasive surgeries. It was noted early in the development of these devices that elastic energy storage can lead to a rapid snapping motion for designs with moderate to high tube curvatures. Substantial progress has recently been made in the concentric tube robot community in designing snap-free robots, planning stable paths, and characterizing conditions that result in snapping for specific classes of concentric tube robots. However, a general measure for determining the stability of a given robot configuration has yet to be proposed. In this paper, we use bifurcation and elastic stability theory to provide such a measure, as well as to produce a test for determining whether a given design is snap-free (i.e., whether snapping can occur anywhere in the unloaded robot's workspace). These results are useful in designing, planning motions for, and controlling concentric tube robots with high curvatures.
- 11 December 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 1 (1) , 98-105
Rapid, Reliable Shape Setting of Superelastic Nitinol for Prototyping Robots
Shape setting Nitinol tubes and wires in a typical laboratory setting for use in superelastic robots is challenging. Obtaining samples that remain superelastic and exhibit desired precurvatures currently requires many iterations, which is time consuming and consumes a substantial amount of Nitinol. To provide a more accurate and reliable method of shape setting, in this paper we propose an electrical technique that uses Joule heating to attain the necessary shape setting temperatures. The resulting high power heating prevents unintended aging of the material and yields consistent and accurate results for the rapid creation of prototypes. We present a complete algorithm and system together with an experimental analysis of temperature regulation. We experimentally validate the approach on Nitinol tubes that are shape set into planar curves. We also demonstrate the feasibility of creating general space curves by shape setting a helical tube. The system demonstrates a mean absolute temperature error of 10 °C.
- 11 December 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 1 (1) , 98-105
Rapid, Reliable Shape Setting of Superelastic Nitinol for Prototyping Robots
Shape setting Nitinol tubes and wires in a typical laboratory setting for use in superelastic robots is challenging. Obtaining samples that remain superelastic and exhibit desired precurvatures currently requires many iterations, which is time consuming and consumes a substantial amount of Nitinol. To provide a more accurate and reliable method of shape setting, in this paper we propose an electrical technique that uses Joule heating to attain the necessary shape setting temperatures. The resulting high power heating prevents unintended aging of the material and yields consistent and accurate results for the rapid creation of prototypes. We present a complete algorithm and system together with an experimental analysis of temperature regulation. We experimentally validate the approach on Nitinol tubes that are shape set into planar curves. We also demonstrate the feasibility of creating general space curves by shape setting a helical tube. The system demonstrates a mean absolute temperature error of 10 °C.
- 1 May 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2015 (10504729) , 1776-1781
A wrist for needle-sized surgical robots
The needle-sized surgical tools used in arthroscopy, otolaryngology, and other surgical fields could become even more valuable to surgeons if endowed with the ability to navigate around sharp corners to manipulate or visualize tissue. We present a needle-sized wrist design that grants this ability. It can be easily interfaced with manual tools or concentric tube robots and is straightforward and inexpensive to manufacture. The wrist consists of a nitinol tube with several asymmetric cutouts, actuated by a tendon. Perhaps counter-intuitively, within this seemingly simple design concept, design optimization is challenging due to the number of parameters available and nonlinearities in material properties. In this paper, we examine a subset of possible geometries and derive kinematic and static models. Experimental results with a 1.16 mm diameter prototype validate the models. Lastly, we provide a discussion summarizing the lessons learned in our early experience designing and fabricating wrists of this type.
- 1 May 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2015 (10504729) , 1776-1781
A wrist for needle-sized surgical robots
The needle-sized surgical tools used in arthroscopy, otolaryngology, and other surgical fields could become even more valuable to surgeons if endowed with the ability to navigate around sharp corners to manipulate or visualize tissue. We present a needle-sized wrist design that grants this ability. It can be easily interfaced with manual tools or concentric tube robots and is straightforward and inexpensive to manufacture. The wrist consists of a nitinol tube with several asymmetric cutouts, actuated by a tendon. Perhaps counter-intuitively, within this seemingly simple design concept, design optimization is challenging due to the number of parameters available and nonlinearities in material properties. In this paper, we examine a subset of possible geometries and derive kinematic and static models. Experimental results with a 1.16 mm diameter prototype validate the models. Lastly, we provide a discussion summarizing the lessons learned in our early experience designing and fabricating wrists of this type.
- 10 February 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Robotics
- Vol. 31 (2) , 246-258
Concentric Tube Robots as Steerable Needles: Achieving Follow-the-Leader Deployment
Concentric tube robots can enable new clinical interventions if they are able to pass through soft tissue, deploy along desired paths through open cavities, or travel along winding lumens. These behaviors require the robot to deploy in such a way that the curved shape of its shaft remains unchanged as the tip progresses forward (i.e., “follow-the-leader” deployment). Follow-the-leader deployment is challenging for concentric tube robots due to elastic (and particularly torsional) coupling between the tubes that form the robot. However, as we show in this paper, follow-the-leader deployment is possible, provided that tube precurvatures and deployment sequences are appropriately selected. We begin by defining follow-the-leader deployment and providing conditions that must be satisfied for a concentric tube robot to achieve it. We then examine several useful special cases of follow-the-leader deployment, showing that both circular and helical precurvatures can be employed, and provide an experimental illustration of the helical case. We also explore approximate follow-the-leader behavior and provide a metric for the similarity of a general deployment to a follow-the-leader deployment. Finally, we consider access to the hippocampus in the brain to treat epilepsy, as a motivating clinical example for follow-the-leader deployment.
- 10 February 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Robotics
- Vol. 31 (2) , 246-258
Concentric Tube Robots as Steerable Needles: Achieving Follow-the-Leader Deployment
Concentric tube robots can enable new clinical interventions if they are able to pass through soft tissue, deploy along desired paths through open cavities, or travel along winding lumens. These behaviors require the robot to deploy in such a way that the curved shape of its shaft remains unchanged as the tip progresses forward (i.e., “follow-the-leader” deployment). Follow-the-leader deployment is challenging for concentric tube robots due to elastic (and particularly torsional) coupling between the tubes that form the robot. However, as we show in this paper, follow-the-leader deployment is possible, provided that tube precurvatures and deployment sequences are appropriately selected. We begin by defining follow-the-leader deployment and providing conditions that must be satisfied for a concentric tube robot to achieve it. We then examine several useful special cases of follow-the-leader deployment, showing that both circular and helical precurvatures can be employed, and provide an experimental illustration of the helical case. We also explore approximate follow-the-leader behavior and provide a metric for the similarity of a general deployment to a follow-the-leader deployment. Finally, we consider access to the hippocampus in the brain to treat epilepsy, as a motivating clinical example for follow-the-leader deployment.
- 27 November 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 60 (4) , 906-909
A Flexure-Based Steerable Needle: High Curvature With Reduced Tissue Damage
In the quest to design higher curvature bevel-steered needles, kinked bevel-tips have been one of the most successful approaches yet proposed. However, the price to be paid for enhancing steerability in this way has been increased tissue damage, since the prebent tip cuts a local helical path into tissue when axially rotated. This is problematic when closed-loop control is desired, because the controller will typically require the needle to rotate rapidly, and it is particularly problematic when duty cycling (i.e., continual needle spinning) is used to adjust curvature. In this paper, we propose a new flexure-based needle tip design that provides the enhanced steerability of kinked bevel-tip needles, while simultaneously minimizing tissue damage.
- 27 November 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 60 (4) , 906-909
A Flexure-Based Steerable Needle: High Curvature With Reduced Tissue Damage
In the quest to design higher curvature bevel-steered needles, kinked bevel-tips have been one of the most successful approaches yet proposed. However, the price to be paid for enhancing steerability in this way has been increased tissue damage, since the prebent tip cuts a local helical path into tissue when axially rotated. This is problematic when closed-loop control is desired, because the controller will typically require the needle to rotate rapidly, and it is particularly problematic when duty cycling (i.e., continual needle spinning) is used to adjust curvature. In this paper, we propose a new flexure-based needle tip design that provides the enhanced steerability of kinked bevel-tip needles, while simultaneously minimizing tissue damage.