    The Significance of the Adaptive Thermal Comfort Limits on the Air-Conditioning Loads in a Temperate Climate

    by Aiman Albatayneh, Dariusz Alterman, Adrian Page, Behdad Moghtaderi

    The building industry is regarded a major contributor to climate change as energy consumption from buildings accounts for 40% of the total energy. The types of thermal comfort models used to predict the heating and cooling loads are critical to save energy in operative buildings and reduce greenhouse gas emissions (GHG). In this research, the internal air temperatures were recorded for over one year under the free floating mode with no heating or cooling, then the number of hours required for heating or cooling were calculated based on fixed sets of operative temperatures (18 °C–24 °C) and the adaptive thermal comfort model to estimate the number of hours per year required for cooling and heating to sustain the occupants’ thermal comfort for four full-scale housing test modules at the campus of the University of Newcastle, Australia. The adaptive thermal comfort model significantly reduced the time necessary for mechanical cooling and heating by more than half when compared with the constant thermostat setting used by the air-conditioning systems installed on the site. It was found that the air-conditioning system with operational temperature setups using the adaptive thermal comfort model at 80% acceptability limits required almost half the operating energy when compared with fixed sets of operating temperatures. This can be achieved by applying a broader range of acceptable temperature limits and using techniques that require minimal energy to sustain the occupants’ thermal comfort.


  • Open Access

    The Impact of the Thermal Comfort Models on the Prediction of Building Energy Consumption

    by Aiman Albatayneh, Dariusz Alterman, Adrian Page, Behdad Moghtaderi

    Building energy assessment software/programs use various assumptions and types of thermal comfort models to forecast energy consumption. This paper compares the results of using two major thermal comfort models (adaptive thermal comfort and the predicted mean vote (PMV) adjusted by the expectancy factor) to examine their influence on the prediction of the energy consumption for several full-scale housing experimental modules constructed on the campus of the University of Newcastle, Australia. Four test modules integrating a variety of walling types (insulated cavity brick (InsCB), cavity brick (CB), insulated reverse brick veneer (InsRBV), and insulated brick veneer (InsBV)) were used for comparing the time necessary for cooling and heating to maintain internal thermal comfort for both models. This research paper exhibits the benefits of adopting the adaptive thermal model for building structures. It shows the effectiveness of this model in helping to reduce energy consumption, increasing the thermal comfort level for the buildings, and therefore reducing greenhouse emissions.


  • Open Access

    The Significance of Temperature Based Approach Over the Energy Based Approaches in the Buildings Thermal Assessment

    by Aiman Albatayneh, Dariusz Alterman, Adrian Page, Behdad Moghtaderi

    The design of low energy buildings requires accurate thermal simulation software to assess the heating and cooling loads. Such designs should sustain thermal comfort for occupants and promote less energy usage over the life time of any building. One of the house energy rating used in Australia is AccuRate, star rating tool to assess and compare the thermal performance of various buildings where the heating and cooling loads are calculated based on fixed operational temperatures between 20 °C to 25 °C to sustain thermal comfort for the occupants. However, these fixed settings for the time and temperatures considerably increase the heating and cooling loads. On the other hand the adaptive thermal model applies a broader range of weather conditions, interacts with the occupants and promotes low energy solutions to maintain thermal comfort. This can be achieved by natural ventilation (opening window/doors), suitable clothes, shading and low energy heating/cooling solutions for the occupied spaces (rooms). These activities will save significant amount of operating energy what can to be taken into account to predict energy consumption for a building. Most of the buildings thermal assessment tools depend on energy-based approaches to predict the thermal performance of any building e.g. AccuRate in Australia. This approach encourages the use of energy to maintain thermal comfort. This paper describes the advantages of a temperature-based approach to assess the building’s thermal performance (using an adaptive thermal comfort model) over energy based approach (AccuRate Software used in Australia). The temperature-based approach was validated and compared with the energy-based approach using four full scale housing test modules located in Newcastle, Australia (Cavity Brick (CB), Insulated Cavity Brick (InsCB), Insulated Brick Veneer (InsBV) and Insulated Reverse Brick Veneer (InsRBV)) subjected to a range of seasonal conditions in a moderate climate. The time required for heating and/or cooling using the adaptive thermal comfort approach and AccuRate predictions were estimated. Significant savings (of about 50 %) in energy consumption in minimising the time required for heating and cooling were achieved by using the adaptive thermal comfort model.


  • Open Access

    WARMING ISSUES ASSOCIATED WITH THE LONG TERM SIMULATION OF HOUSING USING CFD ANALYSIS

    by Aiman Albatayneh, Dariusz Alterman, Adrian W. Page, Behdad Moghtaderi

    The determination of internal building air temperature has an impact on the design and performance of a building in measuring thermal comfort and heating and cooling loads. There is software to assist with measuring internal building air temperature such as Autodesk CFD simulation. However, the use of Autodesk CFD simulation for the analysis appears to have an issue with simulations extending over a long term (i.e. months or years) as the internal air temperature in a building keeps rising with time. This paper addresses the challenges encountered using CFD simulation in the modelling of a building for long term performance. A new method to overcome the issue of the progressive rising of internal air temperature using two external air boundaries, one for the external volume (sky boundary) and the other surrounding the building, is suggested in the paper.


  • Open Access

    THE INFLUENCE OF THERMAL RESISTANCE AND THERMAL MASS ON THE SEASONAL PERFORMANCE OF WALLING SYSTEMS IN AUSTRALIA

    by Dariusz Alterman, Adrian W. Page, Behdad Moghtaderi, Congcong Zhang, Trevor Moffiet

    This paper describes an experimental investigation of the thermal performance of four Australian domestic walling systems (cavity brick, insulated cavity brick, insulated brick veneer and insulated reverse brick veneer) having various combinations of thermal insulation and of thermal mass location within the wall. This experimental analysis extends further the previous studies of the benefits of thermal mass on the overall thermal performance of building enclosures (Gregory et al. 2008, Luo at al. 2008, Alashaary et al. 2009). The comparison is based on the time required to maintain thermal comfort for free-floating internal conditions. The results clearly show that internal comfort levels are influenced by both the thermal resistance of the walls as well as the extent and location of the thermal mass, with neither parameter being the sole predictor. The best thermal performance is therefore obtained by an appropriate combination of thermal mass and resistance, rather than focussing on the overall wall thermal resistance (R-value) alone. A new approach of density temperature plots for comparison of temperature variation is also used in the assessment of module thermal performance.