Matthias Prall
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Matthias Prall has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
- Christian Graeff
GSI Helmholtzzentrum fūr Schwerionenforschung, Darmstadt, Germany
2 shared publications - Marco Durante
Biophysics Department, GSI Helmholtzzentrum für Schwerionenforschung, Planckstraße 1, 64291, Darmstadt, Germany; Institute of Condensed Matter Physics, Technische Universität Darmstadt, Hochschulstr. 6, 64289, Darmstadt, Germany; Department of Physics "Ettore Pancini", University Federico II, Via Cintia, 21 - Building 6, 80126, Naples, Italy
2 shared publications Alexander Weymann
1 shared publicationAnna Constantinescu
1 shared publicationB. Przybyla
Deutsches Zentrum für Luft- und Raumfahrt (DLR), Lindner Höhe, 51147 Cologne, Germany
1 shared publicationC. LaTessa
Brookhaven National Laboratory, P. O. Box 5000, Upton, NY 11973-5000, USA
1 shared publication
Latest Publications
- Open Access
- 10 June 2016
- Published by Springer Nature in Scientific Reports
- Vol. 6 (1) , 27651
High-energy proton imaging for biomedical applications
The charged particle community is looking for techniques exploiting proton interactions instead of X-ray absorption for creating images of human tissue. Due to multiple Coulomb scattering inside the measured object it has shown to be highly non-trivial to achieve sufficient spatial resolution. We present imaging of biological tissue with a proton microscope. This device relies on magnetic optics, distinguishing it from most published proton imaging methods. For these methods reducing the data acquisition time to a clinically acceptable level has turned out to be challenging. In a proton microscope, data acquisition and processing are much simpler. This device even allows imaging in real time. The primary medical application will be image guidance in proton radiosurgery. Proton images demonstrating the potential for this application are presented. Tomographic reconstructions are included to raise awareness of the possibility of high-resolution proton tomography using magneto-optics.
- 10 June 2016
- Published by Springer Nature in Scientific Reports
- Vol. 6 (1) , 27651
Open AccessHigh-energy proton imaging for biomedical applications
The charged particle community is looking for techniques exploiting proton interactions instead of X-ray absorption for creating images of human tissue. Due to multiple Coulomb scattering inside the measured object it has shown to be highly non-trivial to achieve sufficient spatial resolution. We present imaging of biological tissue with a proton microscope. This device relies on magnetic optics, distinguishing it from most published proton imaging methods. For these methods reducing the data acquisition time to a clinically acceptable level has turned out to be challenging. In a proton microscope, data acquisition and processing are much simpler. This device even allows imaging in real time. The primary medical application will be image guidance in proton radiosurgery. Proton images demonstrating the potential for this application are presented. Tomographic reconstructions are included to raise awareness of the possibility of high-resolution proton tomography using magneto-optics.
- 1 January 2015
- Published by Walter de Gruyter GmbH in Biomedical Engineering / Biomedizinische Technik
- Vol. 60 (2) , 147-156
Treatment of arrhythmias by external charged particle beams: a Langendorff feasibility study
Hadron therapy has already proven to be successful in cancer therapy, and might be a noninvasive alternative for the ablation of cardiac arrhythmias in humans. We present a pilot experiment investigating acute effects of a 12C irradiation on the AV nodes of porcine hearts in a Langendorff setup. This setup was adapted to the requirements of charged particle therapy. Treatment plans were computed on calibrated CTs of the hearts. Irradiation was applied in units of 5 and 10 Gy over a period of about 3 h until a total dose of up to 160 Gy was reached. Repeated application of the same irradiation field helped to mitigate motion artifacts in the resulting dose distribution. After irradiation, PET scans were performed to verify accurate dose application. Acute AV blocks were identified. No other acute effects were observed. Hearts were kept in sinus rhythm for up to 6 h in the Langendorff setup. We demonstrated that 12C ions can be used to select a small target in the heart and, thereby, influence the electrical conduction system. Second, our pilot study seems to suggest that no adverse effects have to be expected immediately during heavy ion irradiation in performing subsequent experiments with doses of 30-60 Gy and intact pigs.
- 1 January 2015
- Published by Walter de Gruyter GmbH in Biomedical Engineering / Biomedizinische Technik
- Vol. 60 (2) , 147-156
Treatment of arrhythmias by external charged particle beams: a Langendorff feasibility study
Hadron therapy has already proven to be successful in cancer therapy, and might be a noninvasive alternative for the ablation of cardiac arrhythmias in humans. We present a pilot experiment investigating acute effects of a 12C irradiation on the AV nodes of porcine hearts in a Langendorff setup. This setup was adapted to the requirements of charged particle therapy. Treatment plans were computed on calibrated CTs of the hearts. Irradiation was applied in units of 5 and 10 Gy over a period of about 3 h until a total dose of up to 160 Gy was reached. Repeated application of the same irradiation field helped to mitigate motion artifacts in the resulting dose distribution. After irradiation, PET scans were performed to verify accurate dose application. Acute AV blocks were identified. No other acute effects were observed. Hearts were kept in sinus rhythm for up to 6 h in the Langendorff setup. We demonstrated that 12C ions can be used to select a small target in the heart and, thereby, influence the electrical conduction system. Second, our pilot study seems to suggest that no adverse effects have to be expected immediately during heavy ion irradiation in performing subsequent experiments with doses of 30-60 Gy and intact pigs.