Alan D. Legatt
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Alan D. Legatt has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Alexis Boro
Saul Korey Department of Neurology, Comprehensive Epilepsy Management Center, Montefiore Medical Center, Albert Einstein College of Medicine, Bronx, New York, United States
1 shared publication Avra S. Laarakker
Ruth & Bruce Rappaport Faculty of Medicine, Technion-Israel Institute of Technology, Haifa, Israel
1 shared publicationCharles M. Epstein
Departments of Neurology, Neuroscience, and Internal Medicine (Critical Care Medicine), Montefiore Medical Center and the Albert Einstein College of Medicine, Bronx, New York, U.S.A.
1 shared publication- Daniel Jose Correa
Saul R. Korey Department of Neurology Albert Einstein College of Medicine Bronx NY USA
1 shared publication David B. MacDonald
Departments of Neurology, Neuroscience, and Internal Medicine (Critical Care Medicine), Montefiore Medical Center and the Albert Einstein College of Medicine, Bronx, New York, U.S.A.
1 shared publication- David Joseph Altschul
Department of Neurosurgery, Montefiore Medical Center, Bronx, New York, USA
1 shared publication
Latest Publications
- 1 October 2021
- Published by Elsevier in Seizure: European Journal of Epilepsy
- Vol. 91, 402-408
Factors associated with patients not proceeding with proposed resective epilepsy surgery
- 1 October 2021
- Published by Elsevier in Seizure: European Journal of Epilepsy
- Vol. 91, 402-408
Factors associated with patients not proceeding with proposed resective epilepsy surgery
- 1 January 2018
- Published by Wolters Kluwer Health in Journal Of Clinical Neurophysiology
- Vol. 35 (1) , 25-38
Electrophysiology of Cranial Nerve Testing: Auditory Nerve
The electrocochleogram and brainstem auditory evoked potentials (BAEPs) are electrophysiologic signals used to assess the auditory nerve. The electrocohleogram includes the cochlear microphonic, the cochlear summating potential, and the eighth nerve compound action potential. It is used predominantly for hearing assessment and for diagnosis of Ménière disease and auditory neuropathy. Brainstem auditory evoked potentials are used for hearing assessment, diagnosis of dysfunction within the cochlea, the auditory nerve, and the brainstem auditory pathways up to the level of the mesencephalon, and intraoperative monitoring of these structures. The earliest BAEP component, wave I, and the eighth nerve compound action potential reflect the same process—the initial depolarization in the distal auditory nerve. Brainstem auditory evoked potential wave II receives contributions from the region of the cochlear nucleus and from the second depolarization in the distal auditory nerve. Wave III and later components are entirely generated rostral to the auditory nerve. Interpretation of BAEP studies is based on waves I, III, and V; auditory nerve dysfunction is manifested as prolongation of the I–III interpeak interval or absence of waves III and V. Eighth nerve tumors can cause a variety of BAEP abnormalities depending on which structures they affect. Adverse intraoperative BAEP changes can have many etiologies, including direct mechanical or thermal injury of tissue, ischemia (including cochlear ischemia or infarction due to compromise of the internal auditory artery), eighth nerve stretch, systemic or localized hypothermia, and artifactual BAEP changes due to technical factors.
- 1 January 2018
- Published by Wolters Kluwer Health in Journal Of Clinical Neurophysiology
- Vol. 35 (1) , 25-38
Electrophysiology of Cranial Nerve Testing: Auditory Nerve
The electrocochleogram and brainstem auditory evoked potentials (BAEPs) are electrophysiologic signals used to assess the auditory nerve. The electrocohleogram includes the cochlear microphonic, the cochlear summating potential, and the eighth nerve compound action potential. It is used predominantly for hearing assessment and for diagnosis of Ménière disease and auditory neuropathy. Brainstem auditory evoked potentials are used for hearing assessment, diagnosis of dysfunction within the cochlea, the auditory nerve, and the brainstem auditory pathways up to the level of the mesencephalon, and intraoperative monitoring of these structures. The earliest BAEP component, wave I, and the eighth nerve compound action potential reflect the same process—the initial depolarization in the distal auditory nerve. Brainstem auditory evoked potential wave II receives contributions from the region of the cochlear nucleus and from the second depolarization in the distal auditory nerve. Wave III and later components are entirely generated rostral to the auditory nerve. Interpretation of BAEP studies is based on waves I, III, and V; auditory nerve dysfunction is manifested as prolongation of the I–III interpeak interval or absence of waves III and V. Eighth nerve tumors can cause a variety of BAEP abnormalities depending on which structures they affect. Adverse intraoperative BAEP changes can have many etiologies, including direct mechanical or thermal injury of tissue, ischemia (including cochlear ischemia or infarction due to compromise of the internal auditory artery), eighth nerve stretch, systemic or localized hypothermia, and artifactual BAEP changes due to technical factors.
- 14 February 2017
- Published by Wolters Kluwer Health in Neurology
- Vol. 88 (7) , 716-717
“Alligators All Around” and the ICD-10 code set
- 14 February 2017
- Published by Wolters Kluwer Health in Neurology
- Vol. 88 (7) , 716-717
“Alligators All Around” and the ICD-10 code set
- 1 February 2017
- Published by Elsevier in Seizure: European Journal of Epilepsy
- Vol. 45, 114-118
Clinical outcomes in patients with generalized periodic discharges
- 1 February 2017
- Published by Elsevier in Seizure: European Journal of Epilepsy
- Vol. 45, 114-118
Clinical outcomes in patients with generalized periodic discharges
- 1 November 2016
- Published by Journal of Neurosurgery Publishing Group (JNSPG) in Journal of Neurosurgery: Spine
- Vol. 25 (5) , 566-571
Somatosensory evoked potential monitoring detection of carotid compression during ACDF surgery in a patient with a vascularly isolated hemisphere
The authors report herein a case of anterior cervical discectomy and fusion (ACDF) surgery in which findings on somatosensory evoked potential (SSEP) monitoring led to the correction of carotid artery compression in a patient with a vascularly isolated hemisphere (no significant collateral blood vessels to the carotid artery territory). The amplitude of the cortical SSEP component to left ulnar nerve stimulation progressively decreased in multiple runs, but there were no changes in the cervicomedullary SSEP component to the same stimulus. When the lateral (right-sided) retractor was removed, the cortical SSEP component returned to baseline. The retraction was then intermittently relaxed during the rest of the operation, and the patient suffered no neurological morbidity. Magnetic resonance angiography demonstrated a vascularly isolated right hemisphere. During anterior cervical spine surgery, carotid artery compression by the retractor can cause hemispheric ischemia and infarction in patients with inadequate collateral circulation. The primary purpose of SSEP monitoring during ACDF surgery is to detect compromise of the dorsal column somatosensory pathways within the cervical spinal cord, but intraoperative SSEP monitoring can also detect hemispheric ischemia. Concurrent recording of cervicomedullary SSEPs can help differentiate cortical SSEP changes due to hemispheric ischemia from those due to compromise of the dorsal column pathways. If there are adverse changes in the cortical SSEPs but no changes in the cervicomedullary SSEPs, the possibility of hemispheric ischemia due to carotid artery compression by the retractor should be considered.
- 1 November 2016
- Published by Journal of Neurosurgery Publishing Group (JNSPG) in Journal of Neurosurgery: Spine
- Vol. 25 (5) , 566-571
Somatosensory evoked potential monitoring detection of carotid compression during ACDF surgery in a patient with a vascularly isolated hemisphere
The authors report herein a case of anterior cervical discectomy and fusion (ACDF) surgery in which findings on somatosensory evoked potential (SSEP) monitoring led to the correction of carotid artery compression in a patient with a vascularly isolated hemisphere (no significant collateral blood vessels to the carotid artery territory). The amplitude of the cortical SSEP component to left ulnar nerve stimulation progressively decreased in multiple runs, but there were no changes in the cervicomedullary SSEP component to the same stimulus. When the lateral (right-sided) retractor was removed, the cortical SSEP component returned to baseline. The retraction was then intermittently relaxed during the rest of the operation, and the patient suffered no neurological morbidity. Magnetic resonance angiography demonstrated a vascularly isolated right hemisphere. During anterior cervical spine surgery, carotid artery compression by the retractor can cause hemispheric ischemia and infarction in patients with inadequate collateral circulation. The primary purpose of SSEP monitoring during ACDF surgery is to detect compromise of the dorsal column somatosensory pathways within the cervical spinal cord, but intraoperative SSEP monitoring can also detect hemispheric ischemia. Concurrent recording of cervicomedullary SSEPs can help differentiate cortical SSEP changes due to hemispheric ischemia from those due to compromise of the dorsal column pathways. If there are adverse changes in the cortical SSEPs but no changes in the cervicomedullary SSEPs, the possibility of hemispheric ischemia due to carotid artery compression by the retractor should be considered.
- 1 February 2016
- Published by Wolters Kluwer Health in Journal Of Clinical Neurophysiology
- Vol. 33 (1) , 42-50
ACNS Guideline
- 1 February 2016
- Published by Wolters Kluwer Health in Journal Of Clinical Neurophysiology
- Vol. 33 (1) , 42-50
ACNS Guideline
- 1 February 2014
- Published by Wolters Kluwer Health in Journal Of Clinical Neurophysiology
- Vol. 31 (1) , 55-57
Median Nerve Somatosensory Evoked Potential Monitoring During Carotid Endarterectomy
Summary: Median nerve somatosensory evoked potential monitoring is commonly used during carotid endarterectomy to permit selective shunting in only those patients who are determined to have inadequate collateral flow after carotid cross-clamping. The N20 component is recorded from the CPc (contralateral centroparietal) electrode; either CPi (ipsilateral centroparietal) or Fpz (forehead) can be used as the reference. Because of the distribution of the subcortically generated N18 component, the CPc-Fpz derivation might record both the N20 and the N18 components and might therefore inadequately detect hemispheric ischemia after carotid cross-clamping. Somatosensory evoked potentials recorded were compared using these 2 derivations during 38 carotid endarterectomies to assess their ability to detect neurophysiologic changes after carotid cross-clamping. Although, as expected, the baseline N20 component was significantly larger when recorded with the CPc-Fpz derivation than with the CPc-CPi derivation (3.1 vs. 2.4 μV in the hemisphere ipsilateral to the clamped carotid, P < 0.001), there was no significant difference in the postclamp amplitude decline between the 2 derivations (8.7% vs. 8.6%, P = 0.82). It is concluded that CPc-Fpz is an acceptable derivation for recording postclamp hemispheric somatosensory evoked potential changes during carotid endarterectomy and may be advantageous because it provides a larger amplitude somatosensory evoked potential than the CPc–CPi derivation.
- 1 February 2014
- Published by Wolters Kluwer Health in Journal Of Clinical Neurophysiology
- Vol. 31 (1) , 55-57
Median Nerve Somatosensory Evoked Potential Monitoring During Carotid Endarterectomy
Summary: Median nerve somatosensory evoked potential monitoring is commonly used during carotid endarterectomy to permit selective shunting in only those patients who are determined to have inadequate collateral flow after carotid cross-clamping. The N20 component is recorded from the CPc (contralateral centroparietal) electrode; either CPi (ipsilateral centroparietal) or Fpz (forehead) can be used as the reference. Because of the distribution of the subcortically generated N18 component, the CPc-Fpz derivation might record both the N20 and the N18 components and might therefore inadequately detect hemispheric ischemia after carotid cross-clamping. Somatosensory evoked potentials recorded were compared using these 2 derivations during 38 carotid endarterectomies to assess their ability to detect neurophysiologic changes after carotid cross-clamping. Although, as expected, the baseline N20 component was significantly larger when recorded with the CPc-Fpz derivation than with the CPc-CPi derivation (3.1 vs. 2.4 μV in the hemisphere ipsilateral to the clamped carotid, P < 0.001), there was no significant difference in the postclamp amplitude decline between the 2 derivations (8.7% vs. 8.6%, P = 0.82). It is concluded that CPc-Fpz is an acceptable derivation for recording postclamp hemispheric somatosensory evoked potential changes during carotid endarterectomy and may be advantageous because it provides a larger amplitude somatosensory evoked potential than the CPc–CPi derivation.