Nicolas A. Geis
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Nicolas A. Geis has a total of 100 co-authors. Here are the top co-authors by number of shared publications:
- Sven T. Pleger
Department of Internal Medicine III, Heidelberg University, 69120 Heidelberg, Germany
7 shared publications Hugo A. Katus
Department of Internal Medicine III, Cardiology, University Hospital Heidelberg , Im Neuenheimer Feld 410, Heidelberg, 69120
6 shared publications- Hugo Albert Katus
Department of Cardiology, Pulmonology and Angiology, University Hospital Heidelberg, Heidelberg, Germany
6 shared publications - Philip Raake
Department of Internal Medicine III, Cardiology, University Hospital Heidelberg, University of Heidelberg, Heidelberg, Germany
6 shared publications Norbert Frey
Department of Internal Medicine III, University Hospital Heidelberg, Heidelberg, Germany
4 shared publicationsChristina Kiriakou
Department of Internal Medicine III, University Hospital Heidelberg, Germany
3 shared publications
Latest Publications
- 6 December 2023
- Published by Elsevier in Nuclear Medicine and Biology
- Vol. 126-127, 108630
Effects of uncharged linker-modification of PSMA-617-based inhibitors on targeting properties and the pharmacokinetic profile
- 6 December 2023
- Published by Elsevier in Nuclear Medicine and Biology
- Vol. 126-127, 108630
Effects of uncharged linker-modification of PSMA-617-based inhibitors on targeting properties and the pharmacokinetic profile
- Open Access
- 18 May 2023
- Published by IOS Press
- Vol. 302, 819-820
Few-Shot and Prompt Training for Text Classification in German Doctor’s Letters
To classify sentences in cardiovascular German doctor's letters into eleven section categories, we used pattern-exploiting training, a prompt-based method for text classification in few-shot learning scenarios (20, 50 and 100 instances per class) using language models with various pre-training approaches evaluated on CARDIO:DE, a freely available German clinical routine corpus. Prompting improves results by 5-28% accuracy compared to traditional methods, reducing manual annotation efforts and computational costs in a clinical setting.
- 18 May 2023
- Published by IOS Press
- Vol. 302, 819-820
Open AccessFew-Shot and Prompt Training for Text Classification in German Doctor’s Letters
To classify sentences in cardiovascular German doctor's letters into eleven section categories, we used pattern-exploiting training, a prompt-based method for text classification in few-shot learning scenarios (20, 50 and 100 instances per class) using language models with various pre-training approaches evaluated on CARDIO:DE, a freely available German clinical routine corpus. Prompting improves results by 5-28% accuracy compared to traditional methods, reducing manual annotation efforts and computational costs in a clinical setting.
- Open Access
- 14 April 2023
- Published by Springer Nature in Scientific Data
- Vol. 10 (1) , 1-16
A distributable German clinical corpus containing cardiovascular clinical routine doctor’s letters
We present CARDIO:DE, the first freely available and distributable large German clinical corpus from the cardiovascular domain. CARDIO:DE encompasses 500 clinical routine German doctor’s letters from Heidelberg University Hospital, which were manually annotated. Our prospective study design complies well with current data protection regulations and allows us to keep the original structure of clinical documents consistent. In order to ease access to our corpus, we manually de-identified all letters. To enable various information extraction tasks the temporal information in the documents was preserved. We added two high-quality manual annotation layers to CARDIO:DE, (1) medication information and (2) CDA-compliant section classes. To the best of our knowledge, CARDIO:DE is the first freely available and distributable German clinical corpus in the cardiovascular domain. In summary, our corpus offers unique opportunities for collaborative and reproducible research on natural language processing models for German clinical texts.
- 14 April 2023
- Published by Springer Nature in Scientific Data
- Vol. 10 (1) , 1-16
Open AccessA distributable German clinical corpus containing cardiovascular clinical routine doctor’s letters
We present CARDIO:DE, the first freely available and distributable large German clinical corpus from the cardiovascular domain. CARDIO:DE encompasses 500 clinical routine German doctor’s letters from Heidelberg University Hospital, which were manually annotated. Our prospective study design complies well with current data protection regulations and allows us to keep the original structure of clinical documents consistent. In order to ease access to our corpus, we manually de-identified all letters. To enable various information extraction tasks the temporal information in the documents was preserved. We added two high-quality manual annotation layers to CARDIO:DE, (1) medication information and (2) CDA-compliant section classes. To the best of our knowledge, CARDIO:DE is the first freely available and distributable German clinical corpus in the cardiovascular domain. In summary, our corpus offers unique opportunities for collaborative and reproducible research on natural language processing models for German clinical texts.
- Open Access
- 26 August 2022
- Published by MDPI AG in Journal of Cardiovascular Development and Disease
- Vol. 9 (9) , 285
Long-Term Patency of Venous Conduits Targeting the Right Coronary Artery System—Single Is Superior to Sequential bypass Grafting
Objective: Little is known about the fate of bypass grafts to the right coronary system. To investigate the long-term patency of venous bypass grafts directed to the right coronary artery (RCA) based on postoperative angiograms and to identify predictors of graft occlusion. Methods: In this single-center study, all patients who underwent coronary angiography from 2005 to 2021 after previously undergoing isolated coronary artery bypass grafting (CABG) were included. The primary endpoint was graft occlusion over a median follow-up of 9.1 years. Results: Among a total of 1106 patients (17.0% women, 64 (57–71) years median age), 289 (26.1%) received a sequential vein graft and 798 (72.2%) a single graft. Multivariate regression revealed age (HR 1.019, CI 95% 1.007–1.032), the urgency of CABG (HR 1.355, CI 95% 1.108–1.656), and severely impaired left ventricular function (HR 1.883, CI 95% 1.290–2.748), but not gender and chronic total occlusion (CTO) as predictive factors for graft occlusion. Single conduits were found to be a predictor of graft patency (HR 0.575 CI 95% 0.449–0.737). The angiographic outcome showed an overall 10-year freedom from graft occlusion of 73.4% ± 1.6%. The 5-year (10-year) freedom from graft occlusion was 76.9% ± 2.8% (57.8% ± 4.0%) for sequential grafts and 90.4% ± 1.1% (77.8% ± 1.7%) for single grafts (log-rank p < 0.001). Conclusions: In symptomatic patients with renewed angiography, venous bypass grafting of the RCA showed acceptable long-term patency rates. Single bypass grafting of the RCA was superior to sequential grafting, which needs to be further investigated.
- 26 August 2022
- Published by MDPI AG in Journal of Cardiovascular Development and Disease
- Vol. 9 (9) , 285
Open AccessLong-Term Patency of Venous Conduits Targeting the Right Coronary Artery System—Single Is Superior to Sequential bypass Grafting
Objective: Little is known about the fate of bypass grafts to the right coronary system. To investigate the long-term patency of venous bypass grafts directed to the right coronary artery (RCA) based on postoperative angiograms and to identify predictors of graft occlusion. Methods: In this single-center study, all patients who underwent coronary angiography from 2005 to 2021 after previously undergoing isolated coronary artery bypass grafting (CABG) were included. The primary endpoint was graft occlusion over a median follow-up of 9.1 years. Results: Among a total of 1106 patients (17.0% women, 64 (57–71) years median age), 289 (26.1%) received a sequential vein graft and 798 (72.2%) a single graft. Multivariate regression revealed age (HR 1.019, CI 95% 1.007–1.032), the urgency of CABG (HR 1.355, CI 95% 1.108–1.656), and severely impaired left ventricular function (HR 1.883, CI 95% 1.290–2.748), but not gender and chronic total occlusion (CTO) as predictive factors for graft occlusion. Single conduits were found to be a predictor of graft patency (HR 0.575 CI 95% 0.449–0.737). The angiographic outcome showed an overall 10-year freedom from graft occlusion of 73.4% ± 1.6%. The 5-year (10-year) freedom from graft occlusion was 76.9% ± 2.8% (57.8% ± 4.0%) for sequential grafts and 90.4% ± 1.1% (77.8% ± 1.7%) for single grafts (log-rank p < 0.001). Conclusions: In symptomatic patients with renewed angiography, venous bypass grafting of the RCA showed acceptable long-term patency rates. Single bypass grafting of the RCA was superior to sequential grafting, which needs to be further investigated.
- Open Access
Impact of Percutaneous Mitral Valve Repair Using the MitraClipTM System on Ventricular Arrhythmias and ICD Therapies
Transcatheter edge-to-edge repair (TEER) using the MitraClip™ device has been established as a suitable alternative to mitral valve surgery in patients with severe mitral regurgitation (MR) and high or prohibitive surgical risk. Only limited information regarding the impact of TEER on ventricular arrhythmias (VA) has been reported. The aim of the present study was to assess the impact of TEER using the MitraClipTM device on the burden of VA and ICD (Implantable Cardioverter Defibrillator) therapies. Among 600 MitraClipTM implantations performed in our clinic between September 2009 and October 2018, we identified 86 patients with successful TEER and an active implantable cardiac device (pacemaker, ICD, CRT-P/D (Cardiac Resynchronization Therapy-Pacemaker/Defibrillator)) eligible for retrospective VA analyses. These patients presented with mainly functional MR (81.4%) and severely reduced left ventricular ejection fraction (mean LVEF 22.1% ± 10.3%). The observation period comprised 456 ± 313 days before and 424 ± 287 days after TEER. The burden of ventricular arrhythmias (sustained ventricular tachycardia (sVT) and ventricular fibrillation (VF)) was significantly reduced after TEER (0.85 ± 3.47 vs. 0.43 ± 2.03 events per patient per month, p = 0.01). Furthermore, the rate of ICD therapies (anti-tachycardia pacing (ATP) and ICD shock) decreased significantly after MitraClipTM implantation (1.0 ± 3.87 vs. 0.32 ± 1.41, p = 0.014). However, reduction of VA burden did not result in improved two-year survival in this patient cohort with severely reduced LVEF. Mitral valve TEER using the MitraClip™ device was associated with a significant reduction of ventricular arrhythmias and ICD therapies.
Open AccessImpact of Percutaneous Mitral Valve Repair Using the MitraClipTM System on Ventricular Arrhythmias and ICD Therapies
Transcatheter edge-to-edge repair (TEER) using the MitraClip™ device has been established as a suitable alternative to mitral valve surgery in patients with severe mitral regurgitation (MR) and high or prohibitive surgical risk. Only limited information regarding the impact of TEER on ventricular arrhythmias (VA) has been reported. The aim of the present study was to assess the impact of TEER using the MitraClipTM device on the burden of VA and ICD (Implantable Cardioverter Defibrillator) therapies. Among 600 MitraClipTM implantations performed in our clinic between September 2009 and October 2018, we identified 86 patients with successful TEER and an active implantable cardiac device (pacemaker, ICD, CRT-P/D (Cardiac Resynchronization Therapy-Pacemaker/Defibrillator)) eligible for retrospective VA analyses. These patients presented with mainly functional MR (81.4%) and severely reduced left ventricular ejection fraction (mean LVEF 22.1% ± 10.3%). The observation period comprised 456 ± 313 days before and 424 ± 287 days after TEER. The burden of ventricular arrhythmias (sustained ventricular tachycardia (sVT) and ventricular fibrillation (VF)) was significantly reduced after TEER (0.85 ± 3.47 vs. 0.43 ± 2.03 events per patient per month, p = 0.01). Furthermore, the rate of ICD therapies (anti-tachycardia pacing (ATP) and ICD shock) decreased significantly after MitraClipTM implantation (1.0 ± 3.87 vs. 0.32 ± 1.41, p = 0.014). However, reduction of VA burden did not result in improved two-year survival in this patient cohort with severely reduced LVEF. Mitral valve TEER using the MitraClip™ device was associated with a significant reduction of ventricular arrhythmias and ICD therapies.
- Open Access
- 15 February 2022
- Published by Oxford University Press (OUP) in ESC Heart Failure
- Vol. 9 (2) , 853-865
One-Year Results Following PASCAL-Based or MitraClip-Based Mitral Valve Transcatheter Edge-to-Edge Repair
Aims Mitral valve transcatheter edge-to-edge repair (TEER) has been established as a suitable alternative to mitral valve surgery in patients with severe mitral regurgitation (MR) and high surgical risk. The PASCAL system represents a novel device, potentially augmenting the toolkit for TEER. The aim of this study was to assess and compare short and 1 year safety and efficacy of the PASCAL and MitraClip systems for TEER. Methods and results Procedural, short, and 1 year outcomes of a 1:2 propensity-matched cohort including 41 PASCAL and 82 MitraClip cases were investigated. Matching was based on clinical, laboratory, echocardiographic, and functional characteristics. The primary endpoints assessed were procedural success [as defined by the Mitral Valve Academy Research Consortium (MVARC)], residual MR, functional class, and a composite endpoint comprising death, heart failure hospitalization, and mitral valve re-intervention. We found for the PASCAL and the matched MitraClip cohort no significant differences in MVARC defined technical (90.2% vs. 95.1%, P = 0.44), device (90.2% vs. 89.0%, P = 1.0), or procedural (87.8% vs. 80.5%, P = 0.45) success rates. Accordingly, the overall MR reduction and improvement in New York Heart Association (NYHA) class were comparable (1 year follow-up: MR ≤ 2 95% vs. 93.6%, P = 1.0; NYHA ≤ 2 57.1% vs. 66.7%, P = 0.59). The composite outcome revealed no statistically significant difference between both devices (1 year follow-up: 31.7% vs. 37.8%, P = 0.55). Interestingly, we found at both short and 1 year follow-up a significantly higher rate of patients with none or trace MR in the PASCAL-treated cohort (short follow-up: 17.9% vs. 0%, P = 0.0081; 1 year follow-up: 25% vs. 0%, P = 0.0016). Conversely, the rate of aborted device implantations due to an elevated transmitral gradient was higher in PASCAL interventions (9.8% vs. 1.2%, P = 0.04). Conclusions Transcatheter edge-to-edge repair using the PASCAL or MitraClip device results in favourable and comparable outcomes regarding safety, efficacy, and clinical improvement after 1 year.
- 15 February 2022
- Published by Oxford University Press (OUP) in ESC Heart Failure
- Vol. 9 (2) , 853-865
Open AccessOne-Year Results Following PASCAL-Based or MitraClip-Based Mitral Valve Transcatheter Edge-to-Edge Repair
Aims Mitral valve transcatheter edge-to-edge repair (TEER) has been established as a suitable alternative to mitral valve surgery in patients with severe mitral regurgitation (MR) and high surgical risk. The PASCAL system represents a novel device, potentially augmenting the toolkit for TEER. The aim of this study was to assess and compare short and 1 year safety and efficacy of the PASCAL and MitraClip systems for TEER. Methods and results Procedural, short, and 1 year outcomes of a 1:2 propensity-matched cohort including 41 PASCAL and 82 MitraClip cases were investigated. Matching was based on clinical, laboratory, echocardiographic, and functional characteristics. The primary endpoints assessed were procedural success [as defined by the Mitral Valve Academy Research Consortium (MVARC)], residual MR, functional class, and a composite endpoint comprising death, heart failure hospitalization, and mitral valve re-intervention. We found for the PASCAL and the matched MitraClip cohort no significant differences in MVARC defined technical (90.2% vs. 95.1%, P = 0.44), device (90.2% vs. 89.0%, P = 1.0), or procedural (87.8% vs. 80.5%, P = 0.45) success rates. Accordingly, the overall MR reduction and improvement in New York Heart Association (NYHA) class were comparable (1 year follow-up: MR ≤ 2 95% vs. 93.6%, P = 1.0; NYHA ≤ 2 57.1% vs. 66.7%, P = 0.59). The composite outcome revealed no statistically significant difference between both devices (1 year follow-up: 31.7% vs. 37.8%, P = 0.55). Interestingly, we found at both short and 1 year follow-up a significantly higher rate of patients with none or trace MR in the PASCAL-treated cohort (short follow-up: 17.9% vs. 0%, P = 0.0081; 1 year follow-up: 25% vs. 0%, P = 0.0016). Conversely, the rate of aborted device implantations due to an elevated transmitral gradient was higher in PASCAL interventions (9.8% vs. 1.2%, P = 0.04). Conclusions Transcatheter edge-to-edge repair using the PASCAL or MitraClip device results in favourable and comparable outcomes regarding safety, efficacy, and clinical improvement after 1 year.
- 1 September 2021
- Published by Wolters Kluwer Health in Circulation: Cardiovascular Interventions
- Vol. 14 (9) , e010770
Initial Experience With the PASCAL Ace Implant System for Treatment of Severe Tricuspid Regurgitation
Background: Percutaneous tricuspid valve leaflet repair is an emerging treatment option for severe tricuspid regurgitation (TR). Recent studies demonstrated the usefulness and feasibility of the lately introduced TriClip and PASCAL Transcatheter Valve Repair System. However, initial experiences regarding safety and efficacy of the novel transcatheter PASCAL Ace implant system have not yet been reported. Methods: Sixteen patients with severe, massive, or torrential TR underwent tricuspid leaflet repair using the PASCAL Ace implant at our cardiology department. All patients suffered from symptomatic right-sided heart failure with New York Heart Association functional class III or IV. Clinical, laboratory, echocardiographic, and procedural data were assessed. The primary efficiency end point was postprocedural reduction in TR of at least 1 grade. Secondary end points were feasibility, safety, clinical outcome, and improvement of structural and functional right heart parameters obtained by echocardiography. Results: Eleven procedures (69%) resulted in successful reduction of TR. In 4 patients, PASCAL Ace implantation was not successful and one patient did not achieve TR reduction despite PASCAL Ace implantation. One major bleeding related to the intervention occurred. Eight patients (73%) with successful TR reduction reported a significant improvement of New York Heart Association functional class 4 weeks after implantation ( P =0.008). A significant reduction in right atrial volume from 84±41 mL/m 2 to 69±36 mL/m 2 ( P =0.004) and right ventricular end-diastolic diameter from 50±7 mm to 47±8 mm ( P =0.013) was observed; however, we did not see an improvement in right ventricular function directly after implantation. Conclusions: Tricuspid valve leaflet repair using the transcatheter PASCAL Ace implant system has the potential to improve clinical status and right heart reverse remodeling in patients with severe TR.
- 1 September 2021
- Published by Wolters Kluwer Health in Circulation: Cardiovascular Interventions
- Vol. 14 (9) , e010770
Initial Experience With the PASCAL Ace Implant System for Treatment of Severe Tricuspid Regurgitation
Background: Percutaneous tricuspid valve leaflet repair is an emerging treatment option for severe tricuspid regurgitation (TR). Recent studies demonstrated the usefulness and feasibility of the lately introduced TriClip and PASCAL Transcatheter Valve Repair System. However, initial experiences regarding safety and efficacy of the novel transcatheter PASCAL Ace implant system have not yet been reported. Methods: Sixteen patients with severe, massive, or torrential TR underwent tricuspid leaflet repair using the PASCAL Ace implant at our cardiology department. All patients suffered from symptomatic right-sided heart failure with New York Heart Association functional class III or IV. Clinical, laboratory, echocardiographic, and procedural data were assessed. The primary efficiency end point was postprocedural reduction in TR of at least 1 grade. Secondary end points were feasibility, safety, clinical outcome, and improvement of structural and functional right heart parameters obtained by echocardiography. Results: Eleven procedures (69%) resulted in successful reduction of TR. In 4 patients, PASCAL Ace implantation was not successful and one patient did not achieve TR reduction despite PASCAL Ace implantation. One major bleeding related to the intervention occurred. Eight patients (73%) with successful TR reduction reported a significant improvement of New York Heart Association functional class 4 weeks after implantation ( P =0.008). A significant reduction in right atrial volume from 84±41 mL/m 2 to 69±36 mL/m 2 ( P =0.004) and right ventricular end-diastolic diameter from 50±7 mm to 47±8 mm ( P =0.013) was observed; however, we did not see an improvement in right ventricular function directly after implantation. Conclusions: Tricuspid valve leaflet repair using the transcatheter PASCAL Ace implant system has the potential to improve clinical status and right heart reverse remodeling in patients with severe TR.
- Open Access
- 27 August 2021
- Published by Oxford University Press (OUP) in ESC Heart Failure
- Vol. 8 (5) , 3530-3538
PASCAL-Based Mitral Valve Repair in an All-Comer Population: Acute and Mid-Term Clinical Results
Aims: We investigated short and mid-term safety and efficacy of the PASCAL system for percutaneous mitral valve repair (PMVr) in severe mitral regurgitation (MR) in an all-comer population. Methods and results: In the first consecutive 41 patients undergoing PMVr using the PASCAL system in our centre, procedural success and safety were assessed. Efficacy in improving MR and functional class were evaluated. Median patient age was 74 years, 58.5% were male patients, and median European System for Cardiac Operative Risk Evaluation Score II was 5.1%. All patients suffered from severe MR with 59% functional MR, 29% degenerative MR, and 12% of mixed aetiology MR. The technical success rate was 90%, limited by four cases where PASCAL implantation was aborted due to a prohibitive mitral gradient. On average, 1.16 PASCAL devices per patient were implanted. All patients successfully implanted with a PASCAL device were discharged with MR grade ≤ 2 and 79% with MR grade ≤ 1. Mean follow-up was 8.7 ± 4.9 months. Ninety-seven per cent of patients remained at MR ≤ 2 at follow-up, which translated into a significantly improved New York Heart Association functional class as well as a significant reduction of systolic pulmonary artery pressure and brain natriuretic peptide levels. The procedure-related rate for major adverse events was 3%. Neither early nor late single-leaflet detachment was found. In one patient, air embolism occurred, resulting in modification of the PASCAL instructions for use. Conclusions: Percutaneous mitral valve repair using PASCAL in a real-world, all-comer population was feasible and safe, resulting in a significant mid-term reduction of MR with persistent clinical improvement.
- 27 August 2021
- Published by Oxford University Press (OUP) in ESC Heart Failure
- Vol. 8 (5) , 3530-3538
Open AccessPASCAL-Based Mitral Valve Repair in an All-Comer Population: Acute and Mid-Term Clinical Results
Aims: We investigated short and mid-term safety and efficacy of the PASCAL system for percutaneous mitral valve repair (PMVr) in severe mitral regurgitation (MR) in an all-comer population. Methods and results: In the first consecutive 41 patients undergoing PMVr using the PASCAL system in our centre, procedural success and safety were assessed. Efficacy in improving MR and functional class were evaluated. Median patient age was 74 years, 58.5% were male patients, and median European System for Cardiac Operative Risk Evaluation Score II was 5.1%. All patients suffered from severe MR with 59% functional MR, 29% degenerative MR, and 12% of mixed aetiology MR. The technical success rate was 90%, limited by four cases where PASCAL implantation was aborted due to a prohibitive mitral gradient. On average, 1.16 PASCAL devices per patient were implanted. All patients successfully implanted with a PASCAL device were discharged with MR grade ≤ 2 and 79% with MR grade ≤ 1. Mean follow-up was 8.7 ± 4.9 months. Ninety-seven per cent of patients remained at MR ≤ 2 at follow-up, which translated into a significantly improved New York Heart Association functional class as well as a significant reduction of systolic pulmonary artery pressure and brain natriuretic peptide levels. The procedure-related rate for major adverse events was 3%. Neither early nor late single-leaflet detachment was found. In one patient, air embolism occurred, resulting in modification of the PASCAL instructions for use. Conclusions: Percutaneous mitral valve repair using PASCAL in a real-world, all-comer population was feasible and safe, resulting in a significant mid-term reduction of MR with persistent clinical improvement.
- Open Access
- 16 December 2020
- Published by Wiley in European Journal of Clinical Investigation
- Vol. 51 (6) , e13473
Initial experience with percutaneous mitral valve repair in patients with cardiac amyloidosis
Background: Percutaneous mitral valve repair (PMVR) is a therapeutic option for severe mitral regurgitation (MR) in patients with heart failure due to differential aetiologies. However, only little is known about the safety and efficacy of this procedure in patients with amyloid cardiomyopathy.Methods: Five patients with cardiac amyloidosis and moderate to severe or severe MR undergoing PMVR were analysed retrospectively and compared to seven patients with cardiac amyloidosis and severe MR without intervention. Clinical and functional data, renal function and cardiac biomarkers as well as established risk scores for cardiac amyloidosis were assessed. Primary endpoint was the reduction in MR one year after PMVR. Secondary endpoints were safety, overall mortality after 12 months compared with the control group, as well as changes in clinical and functional parameters.Results: Amyloidosis risk assessment documented amyloid cardiomyopathy at an advanced stage in all patients. Procedural, technical and device success of PMVR were all 100% and residual MR remained mild to moderate at 12 months follow‐up (P = .038 vs before PMVR). Differences in survival compared with the control (no PMVR) group pointed to a possible survival benefit in the PMVR group (P = .02).Conclusion: PMVR is a feasible and safe procedure in patients with cardiac amyloidosis and might carry a possible survival benefit in this patient group.
- 16 December 2020
- Published by Wiley in European Journal of Clinical Investigation
- Vol. 51 (6) , e13473
Open AccessInitial experience with percutaneous mitral valve repair in patients with cardiac amyloidosis
Background: Percutaneous mitral valve repair (PMVR) is a therapeutic option for severe mitral regurgitation (MR) in patients with heart failure due to differential aetiologies. However, only little is known about the safety and efficacy of this procedure in patients with amyloid cardiomyopathy.Methods: Five patients with cardiac amyloidosis and moderate to severe or severe MR undergoing PMVR were analysed retrospectively and compared to seven patients with cardiac amyloidosis and severe MR without intervention. Clinical and functional data, renal function and cardiac biomarkers as well as established risk scores for cardiac amyloidosis were assessed. Primary endpoint was the reduction in MR one year after PMVR. Secondary endpoints were safety, overall mortality after 12 months compared with the control group, as well as changes in clinical and functional parameters.Results: Amyloidosis risk assessment documented amyloid cardiomyopathy at an advanced stage in all patients. Procedural, technical and device success of PMVR were all 100% and residual MR remained mild to moderate at 12 months follow‐up (P = .038 vs before PMVR). Differences in survival compared with the control (no PMVR) group pointed to a possible survival benefit in the PMVR group (P = .02).Conclusion: PMVR is a feasible and safe procedure in patients with cardiac amyloidosis and might carry a possible survival benefit in this patient group.
- Open Access
- 15 December 2020
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 9 (12) , 4048
Broken Heartstrings—Post-Traumatic Stress Disorder and Psychological Burden after Acute Mitral Regurgitation Due to Chordae Tendineae Rupture
Chordae tendineae rupture (CTR) is a potentially life-threatening cardiac event often resulting in Acute mitral regurgitation (AMR). We assessed Post-traumatic stress disorder (PTSD), depression, and anxiety symptoms in CTR patients with AMR (age 82.3 ± 4.2 years; 66.7% men) and compared them to CTR patients with Chronic mitral regurgitation (CMR) and Myocardial infraction (MI) patients. Regression analyses revealed that PTSD scores were significantly higher in CTR patients with AMR than in CTR patients with CMR or MI patients. CTR patients with CMR had the lowest levels of PTSD-symptoms. Depression and anxiety scores were elevated across all three groups. Our results suggest that psychosocial factors need to be considered in CTR patients’ care.- 15 December 2020
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 9 (12) , 4048
Open AccessBroken Heartstrings—Post-Traumatic Stress Disorder and Psychological Burden after Acute Mitral Regurgitation Due to Chordae Tendineae Rupture
Chordae tendineae rupture (CTR) is a potentially life-threatening cardiac event often resulting in Acute mitral regurgitation (AMR). We assessed Post-traumatic stress disorder (PTSD), depression, and anxiety symptoms in CTR patients with AMR (age 82.3 ± 4.2 years; 66.7% men) and compared them to CTR patients with Chronic mitral regurgitation (CMR) and Myocardial infraction (MI) patients. Regression analyses revealed that PTSD scores were significantly higher in CTR patients with AMR than in CTR patients with CMR or MI patients. CTR patients with CMR had the lowest levels of PTSD-symptoms. Depression and anxiety scores were elevated across all three groups. Our results suggest that psychosocial factors need to be considered in CTR patients’ care.