Nicoletta Doglioni
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Nicoletta Doglioni has a total of 56 co-authors. Here are the top co-authors by number of shared publications:
- Daniele Trevisanuto
Department of Woman’s and Child’s Health, University of Padua, Padua, Italy
10 shared publications - Francesco Cavallin
Independent Statistician, 36020 Solagna, Italy
4 shared publications - Vincenzo Zanardo
Department of Pediatrics, University of Padua School of Medicine, Padua, Italy
3 shared publications - Giuseppe De Bernardo
Department of Woman and Child, Ospedale Buon Consiglio Fatebenefratelli, 80123 Naples, Italy
2 shared publications Alessandra Fasson
1 shared publication- Bayasgalantai Bavuusuren
Department of Pediatrics, Mongolian National University of Medical Science, Ulaanbaatar, Mongolia
1 shared publication
Latest Publications
- Open Access
A Simulation Competition on Neonatal Resuscitation as a New Educational Tool for Pediatric Residents
Background: Training programs on resuscitation have been developed using simulation-based learning to build skills, strengthen cognitive strategies, and improve team performance. This is especially important for residency programs where reduced working hours and high numbers of residents can reduce the educational opportunities during the residency, with lower exposure to practical procedures and prolonged length of training. Within this context, gamification has gained popularity in teaching and learning activities. This report describes the implementation of a competition format in the context of newborn resuscitation and participants’ perceptions of the educational experience. Methods: Thirty-one teams of three Italian pediatric residents participated in a 3-day simulation competition on neonatal resuscitation. The event included an introductory lecture, familiarization time, and competition time in a tournament-like structure using high-fidelity simulation stations. Each match was evaluated by experts in neonatal resuscitation and followed by a debriefing. The scenarios and debriefings of simulation station #1 were live broadcasted in the central auditorium where teams not currently competing could observe. At the end of the event, participants received an online survey regarding their perceptions of the educational experience. Results: 81/93 (87%) participants completed the survey. Training before the event mostly included reviewing protocols and textbooks. Low-fidelity manikins were the most available simulation tools at the residency programs. Overall, the participants were satisfied with the event and appreciated the live broadcast of scenarios and debriefings in the auditorium. Most participants felt that the event improved their knowledge and self-confidence and stimulated them to be more involved in high-fidelity simulations. Suggested areas of improvement included more time for familiarization and improved communication between judges and participants during the debriefing. Conclusions: Participants appreciated the simulation competition. They self-perceived the educational impact of the event and felt that it improved their knowledge and self-confidence. Our findings suggest areas of improvements for further editions and may serve as an educational model for other institutions.
Open AccessA Simulation Competition on Neonatal Resuscitation as a New Educational Tool for Pediatric Residents
Background: Training programs on resuscitation have been developed using simulation-based learning to build skills, strengthen cognitive strategies, and improve team performance. This is especially important for residency programs where reduced working hours and high numbers of residents can reduce the educational opportunities during the residency, with lower exposure to practical procedures and prolonged length of training. Within this context, gamification has gained popularity in teaching and learning activities. This report describes the implementation of a competition format in the context of newborn resuscitation and participants’ perceptions of the educational experience. Methods: Thirty-one teams of three Italian pediatric residents participated in a 3-day simulation competition on neonatal resuscitation. The event included an introductory lecture, familiarization time, and competition time in a tournament-like structure using high-fidelity simulation stations. Each match was evaluated by experts in neonatal resuscitation and followed by a debriefing. The scenarios and debriefings of simulation station #1 were live broadcasted in the central auditorium where teams not currently competing could observe. At the end of the event, participants received an online survey regarding their perceptions of the educational experience. Results: 81/93 (87%) participants completed the survey. Training before the event mostly included reviewing protocols and textbooks. Low-fidelity manikins were the most available simulation tools at the residency programs. Overall, the participants were satisfied with the event and appreciated the live broadcast of scenarios and debriefings in the auditorium. Most participants felt that the event improved their knowledge and self-confidence and stimulated them to be more involved in high-fidelity simulations. Suggested areas of improvement included more time for familiarization and improved communication between judges and participants during the debriefing. Conclusions: Participants appreciated the simulation competition. They self-perceived the educational impact of the event and felt that it improved their knowledge and self-confidence. Our findings suggest areas of improvements for further editions and may serve as an educational model for other institutions.
- 7 January 2021
- Published by Springer Nature in European Journal of Pediatrics
- Vol. 180 (2) , 635-641
Trends in neonatal emergency transport in the last two decades
Although maternal antenatal transfer is the preferred option, some infants inevitably need urgent transport to a tertiary neonatal care facility after birth. This study aimed to investigate trends over time in patient characteristics and respiratory management in a large series of neonatal emergency transfers, in order to provide health caregivers an up-to-date profile of such patients and their therapeutic needs. Trends in patient characteristics and respiratory management were evaluated in 3337 transfers by the Eastern Veneto Neonatal Emergency Transport Service in 2000–2019. Joinpoint regression analysis was performed to evaluate trends and to estimate annual percentage changes (APCs). Proportions of preterm neonates increased (APC2000–2012 2.25%), then decreased (APC2012–2019 − 6.04%). Transfers at birth increased (APC2000–2013 2.69%), then decreased (APC2013–2019 − 5.76%). Proportion of neonates with cardiac and surgical diseases declined (APCs2000–2019 − 6.82% and − 3.32%), while proportion of neonates with neurologic diseases increased (APC2000–2019 8.62%). Use of nasal-continuous-positive-airway-pressure (APC2000–2019 9.72%) and high-flow-nasal-cannula (APC2007–2019 58.51%) at call, and nasal-continuous-positive-airway-pressure (APC2000–2019 13.87%) and nasal-intermittent-mandatory-ventilation (APC2000–2019 32.46%) during transfer increased. Mechanical ventilation during transfer decreased (APC2014–2019 − 10.77%). Use of oxygen concentrations at 21% increased at call and during transfer (APCs 2000–2019 2.24% and 2.44%), while oxygen concentrations above 40% decreased at call and during transfer (APCs 2000–2019 − 3.93% and − 5.12%). Conclusion: Our findings revealed a shift toward a more “gentle” approach and the reduced use of oxygen in respiratory management. Equipment and team expertise should meet the requirements of such changing patients and their therapeutic needs. What is Known: • Although antenatal transfer is the preferred option, some infants inevitably need urgent transport to a tertiary neonatal care facility after birth. • Trend studies investigating cohort information with appropriate statistical methods represent useful instruments to detect changes over time. What is New: • Our findings revealed marked changes in patient characteristics and respiratory management in a large series of neonatal emergency transfers during the last two decades. • Equipment and team expertise should meet the requirements of such changing patients and their therapeutic needs.
- 7 January 2021
- Published by Springer Nature in European Journal of Pediatrics
- Vol. 180 (2) , 635-641
Trends in neonatal emergency transport in the last two decades
Although maternal antenatal transfer is the preferred option, some infants inevitably need urgent transport to a tertiary neonatal care facility after birth. This study aimed to investigate trends over time in patient characteristics and respiratory management in a large series of neonatal emergency transfers, in order to provide health caregivers an up-to-date profile of such patients and their therapeutic needs. Trends in patient characteristics and respiratory management were evaluated in 3337 transfers by the Eastern Veneto Neonatal Emergency Transport Service in 2000–2019. Joinpoint regression analysis was performed to evaluate trends and to estimate annual percentage changes (APCs). Proportions of preterm neonates increased (APC2000–2012 2.25%), then decreased (APC2012–2019 − 6.04%). Transfers at birth increased (APC2000–2013 2.69%), then decreased (APC2013–2019 − 5.76%). Proportion of neonates with cardiac and surgical diseases declined (APCs2000–2019 − 6.82% and − 3.32%), while proportion of neonates with neurologic diseases increased (APC2000–2019 8.62%). Use of nasal-continuous-positive-airway-pressure (APC2000–2019 9.72%) and high-flow-nasal-cannula (APC2007–2019 58.51%) at call, and nasal-continuous-positive-airway-pressure (APC2000–2019 13.87%) and nasal-intermittent-mandatory-ventilation (APC2000–2019 32.46%) during transfer increased. Mechanical ventilation during transfer decreased (APC2014–2019 − 10.77%). Use of oxygen concentrations at 21% increased at call and during transfer (APCs 2000–2019 2.24% and 2.44%), while oxygen concentrations above 40% decreased at call and during transfer (APCs 2000–2019 − 3.93% and − 5.12%). Conclusion: Our findings revealed a shift toward a more “gentle” approach and the reduced use of oxygen in respiratory management. Equipment and team expertise should meet the requirements of such changing patients and their therapeutic needs. What is Known: • Although antenatal transfer is the preferred option, some infants inevitably need urgent transport to a tertiary neonatal care facility after birth. • Trend studies investigating cohort information with appropriate statistical methods represent useful instruments to detect changes over time. What is New: • Our findings revealed marked changes in patient characteristics and respiratory management in a large series of neonatal emergency transfers during the last two decades. • Equipment and team expertise should meet the requirements of such changing patients and their therapeutic needs.
- Open Access
- 18 November 2016
- Published by Springer Nature in Italian Journal of Pediatrics
- Vol. 42 (1) , 1-7
Performances of low level hospital health caregivers after a neonatal resuscitation course
High fidelity simulation has been executed to allow the evaluation of technical and non-technical skills of health caregivers. Our objective was to assess technical and non-technical performances of low level hospitals health caregivers who attended a Neonatal Resuscitation course using high fidelity simulation in a standard-setting scenario. Twenty-three volunteers were asked to manage a simple scenario (infant with secondary apnea) after the course. Technical and non-technical skills were assessed by using previously published scores. Performances were assessed during the scenario and after 2 months by filmed video recordings. Sixteen (69.5%) participants failed to pass the minimum required technical score. Staff experience and participation in previous courses were associated to higher score in technical and non-technical skills, while working in level I or II hospitals did not affect the scores. Previous experience in neonatal resuscitation requiring positive pressure ventilation was associated to better non-technical performance. Technical and non-technical scores were significantly correlated (r = 0.67, p = 0.0005). Delayed and direct evaluation of technical skills provided the same scores. A neonatal resuscitation course, performed by using a high fidelity simulation manikin, had a limited impact on technical and non-technical skills of participants working in low level hospitals. Training programs should be tailored to the participants’ professional background and to the more relevant sessions.
- 18 November 2016
- Published by Springer Nature in Italian Journal of Pediatrics
- Vol. 42 (1) , 1-7
Open AccessPerformances of low level hospital health caregivers after a neonatal resuscitation course
High fidelity simulation has been executed to allow the evaluation of technical and non-technical skills of health caregivers. Our objective was to assess technical and non-technical performances of low level hospitals health caregivers who attended a Neonatal Resuscitation course using high fidelity simulation in a standard-setting scenario. Twenty-three volunteers were asked to manage a simple scenario (infant with secondary apnea) after the course. Technical and non-technical skills were assessed by using previously published scores. Performances were assessed during the scenario and after 2 months by filmed video recordings. Sixteen (69.5%) participants failed to pass the minimum required technical score. Staff experience and participation in previous courses were associated to higher score in technical and non-technical skills, while working in level I or II hospitals did not affect the scores. Previous experience in neonatal resuscitation requiring positive pressure ventilation was associated to better non-technical performance. Technical and non-technical scores were significantly correlated (r = 0.67, p = 0.0005). Delayed and direct evaluation of technical skills provided the same scores. A neonatal resuscitation course, performed by using a high fidelity simulation manikin, had a limited impact on technical and non-technical skills of participants working in low level hospitals. Training programs should be tailored to the participants’ professional background and to the more relevant sessions.
- 29 June 2015
- p. 7-10
Delivery room management of ELBW infants in Italy.
In this article we evaluated the consistency of practice and the adherence to the International Guidelines in early delivery room management of ELBW infants in Italy. A polyethylene bag/wrap was used by 54 centres (55.1%). In Northern regions, one centre (2.5%) reported to use oxygen concentrations >40% to initiate positive pressure ventilation in ELBW infants. These proportions were higher in the Central (14.3%) and Southern (16.2%) areas. A T-piece device for positive pressure ventilation was widely used (77/97, 79.4%). A median of 13% (IQR: 5%-30%) of ELBW infants received chest compressions at birth in Italy. Forty-seven out of 98 (47.9%) centres declared to administer prophylactic surfactant in delivery room. Although there were geographic differences in the country, our results showed a good general adherence to the International Guidelines for Neonatal Resuscitation.
- 29 June 2015
- p. 7-10
Delivery room management of ELBW infants in Italy.
In this article we evaluated the consistency of practice and the adherence to the International Guidelines in early delivery room management of ELBW infants in Italy. A polyethylene bag/wrap was used by 54 centres (55.1%). In Northern regions, one centre (2.5%) reported to use oxygen concentrations >40% to initiate positive pressure ventilation in ELBW infants. These proportions were higher in the Central (14.3%) and Southern (16.2%) areas. A T-piece device for positive pressure ventilation was widely used (77/97, 79.4%). A median of 13% (IQR: 5%-30%) of ELBW infants received chest compressions at birth in Italy. Forty-seven out of 98 (47.9%) centres declared to administer prophylactic surfactant in delivery room. Although there were geographic differences in the country, our results showed a good general adherence to the International Guidelines for Neonatal Resuscitation.
- 1 May 2015
- Published by Elsevier in Resuscitation
- Vol. 90, e5
Intramuscolar epinephrine during neonatal resuscitation
- 1 May 2015
- Published by Elsevier in Resuscitation
- Vol. 90, e5
Intramuscolar epinephrine during neonatal resuscitation
- Open Access
- 15 July 2014
- Published by Springer Nature in Trials
- Vol. 15 (1) , 285
LMA Supreme for neonatal resuscitation: study protocol for a randomized controlled trial
The most important action in the resuscitation of a newborn in the delivery room is to establish effective assisted ventilation. The face mask and endotracheal tube are the devices used to achieve this goal. Laryngeal mask airways that fit over the laryngeal inlet have been shown to be effective for ventilating newborns at birth and should be considered as an alternative to facemask ventilation or endotracheal intubation among newborns weighing >2,000 g or delivered ≥34 weeks’ gestation. A recent systematic review and meta-analysis of supraglottic airways in neonatal resuscitation reported the results of four randomized controlled trials (RCTs) stating that fewer infants in the group using laryngeal mask airways required endotracheal intubation (1.5%) compared to the group using face masks (12.0%). However, there were methodological concerns over all the RCTs including the fact that the majority of the operators in the trials were anesthesiologists.
- 15 July 2014
- Published by Springer Nature in Trials
- Vol. 15 (1) , 285
Open AccessLMA Supreme for neonatal resuscitation: study protocol for a randomized controlled trial
The most important action in the resuscitation of a newborn in the delivery room is to establish effective assisted ventilation. The face mask and endotracheal tube are the devices used to achieve this goal. Laryngeal mask airways that fit over the laryngeal inlet have been shown to be effective for ventilating newborns at birth and should be considered as an alternative to facemask ventilation or endotracheal intubation among newborns weighing >2,000 g or delivered ≥34 weeks’ gestation. A recent systematic review and meta-analysis of supraglottic airways in neonatal resuscitation reported the results of four randomized controlled trials (RCTs) stating that fewer infants in the group using laryngeal mask airways required endotracheal intubation (1.5%) compared to the group using face masks (12.0%). However, there were methodological concerns over all the RCTs including the fact that the majority of the operators in the trials were anesthesiologists.
- 1 September 2011
- Published by Elsevier in Resuscitation
- Vol. 82 (9) , 1251-1252
Upper esophageal lesion following laryngeal mask airway resuscitation in a very low birth weight infant
- 1 September 2011
- Published by Elsevier in Resuscitation
- Vol. 82 (9) , 1251-1252
Upper esophageal lesion following laryngeal mask airway resuscitation in a very low birth weight infant
- 14 June 2010
- Published by Taylor & Francis in The Journal of Maternal-Fetal & Neonatal Medicine
- Vol. 24 (2) , 234-238
Investments for medical equipment in a mother and child health hospital: correlation with level of services/departments
To assess whether investments for medical equipments assigned by a team of experts to a mother and child health hospital located in Mongolia were correlated with structural, organizational, and educational level of its services/departments. A score was used for evaluating the level of each service/department. It was based on a 'structural area' and an 'organizational and educational area'. Destination of funds was determined by a team of experts in collaboration with the head of the service/department. Thirty-three of 36 services/departments (91.6%) were evaluated. A total sum of 4,432,140 Euros to invest in medical equipment was estimated. Assigned investments were inversely correlated with the total (structural plus organizational and educational area) score (n = 33; r = -0.59; p = 0.0002), and the specific scores for structural area (n = 33; r = -0.46; p = 0.005) and organizational and educational area (n = 33; r = -0.56; p = 0.0006). A large part of the funds for medical equipment was destined to services/departments with low organizational and educational conditions, limiting the potential effect of the aid meanwhile supporting the most in need departments. Educational efforts and monitoring of specific long-term indicators are mandatory.
- 14 June 2010
- Published by Taylor & Francis in The Journal of Maternal-Fetal & Neonatal Medicine
- Vol. 24 (2) , 234-238
Investments for medical equipment in a mother and child health hospital: correlation with level of services/departments
To assess whether investments for medical equipments assigned by a team of experts to a mother and child health hospital located in Mongolia were correlated with structural, organizational, and educational level of its services/departments. A score was used for evaluating the level of each service/department. It was based on a 'structural area' and an 'organizational and educational area'. Destination of funds was determined by a team of experts in collaboration with the head of the service/department. Thirty-three of 36 services/departments (91.6%) were evaluated. A total sum of 4,432,140 Euros to invest in medical equipment was estimated. Assigned investments were inversely correlated with the total (structural plus organizational and educational area) score (n = 33; r = -0.59; p = 0.0002), and the specific scores for structural area (n = 33; r = -0.46; p = 0.005) and organizational and educational area (n = 33; r = -0.56; p = 0.0006). A large part of the funds for medical equipment was destined to services/departments with low organizational and educational conditions, limiting the potential effect of the aid meanwhile supporting the most in need departments. Educational efforts and monitoring of specific long-term indicators are mandatory.
- 1 January 2009
- Published by Taylor & Francis in The Journal of Maternal-Fetal & Neonatal Medicine
- Vol. 22 (2) , 148-151
A new device (Cicogna) for transferring the neonate in the delivery room setting: a randomised, controlled trial
We developed a new system ('cicogna') for transferring the neonates into the delivery room setting. Our aim was to compare the 'cicogna' system and the conventional method (plastic basin) with regard to the time needed to transfer the neonate from the operating table to the radiant warmer; and to evaluate the degree of approval for the 'cicogna' expressed by the midwives. In a prospective, randomised, controlled trial including 100 infants (gestational age > or =34 weeks), we measured the time elapsed from the umbilical cord clamping to the positioning of the neonate under the radiant warmer using the 'cicogna' system or the conventional method. Midwives involved in the study were asked to fill out a final, written evaluation regarding the feasibility and the safety of the devices. The time elapsed from the cord clamping to the positioning of the infant under the radiant warmer was significantly shorter for infants who were managed with the 'cicogna' system compared with infants who received standard care: 18.7 +/- 5.6 s vs. 24.5 +/- 9.0 s (p < 0.001). In the evaluation forms, 19 out of 20 midwives (95%) evaluated the 'cicogna' as good or excellent. In comparison with the conventional method, 'cicogna' decreased the time needed to transfer the neonate into delivery room setting and received a high degree of approval by personnel involved in neonatal care. It appears to be a feasible and safe method for transferring the neonate in the setting of the delivery room.
- 1 January 2009
- Published by Taylor & Francis in The Journal of Maternal-Fetal & Neonatal Medicine
- Vol. 22 (2) , 148-151
A new device (Cicogna) for transferring the neonate in the delivery room setting: a randomised, controlled trial
We developed a new system ('cicogna') for transferring the neonates into the delivery room setting. Our aim was to compare the 'cicogna' system and the conventional method (plastic basin) with regard to the time needed to transfer the neonate from the operating table to the radiant warmer; and to evaluate the degree of approval for the 'cicogna' expressed by the midwives. In a prospective, randomised, controlled trial including 100 infants (gestational age > or =34 weeks), we measured the time elapsed from the umbilical cord clamping to the positioning of the neonate under the radiant warmer using the 'cicogna' system or the conventional method. Midwives involved in the study were asked to fill out a final, written evaluation regarding the feasibility and the safety of the devices. The time elapsed from the cord clamping to the positioning of the infant under the radiant warmer was significantly shorter for infants who were managed with the 'cicogna' system compared with infants who received standard care: 18.7 +/- 5.6 s vs. 24.5 +/- 9.0 s (p < 0.001). In the evaluation forms, 19 out of 20 midwives (95%) evaluated the 'cicogna' as good or excellent. In comparison with the conventional method, 'cicogna' decreased the time needed to transfer the neonate into delivery room setting and received a high degree of approval by personnel involved in neonatal care. It appears to be a feasible and safe method for transferring the neonate in the setting of the delivery room.
- 31 January 2007
- Published by Elsevier in The Journal of Pediatrics
- Vol. 150 (1) , 112
Overcoiling of the Umbilical Cord
- 31 January 2007
- Published by Elsevier in The Journal of Pediatrics
- Vol. 150 (1) , 112
Overcoiling of the Umbilical Cord