Miyuki Noguchi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Miyuki Noguchi has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Akihiro Yamasaki
Department of Materials and Life Science, Faculty of Science and Technology, Seikei University, 3-3-1 Kichijoji-kitamachi, Musashino, Tokyo 180-8633, Japan
3 shared publications - Atsushi Mizukoshi
Department of Environmental Medicine and Behavioral Science, Kindai University Faculty of Medicine, Osakasayama, Japan
3 shared publications - Yukio Yanagisawa
Department of Environmental Systems, Institute of Frontier Sciences, The University of Tokyo, 5-1-5 Kashiwanoha, Kashiwa, Chiba 277-8563, Japan
2 shared publications - Atsushi Iizuka
Department of Environmental Studies for Advanced Society Graduate School of Environmental Studies Tohoku University 6‐6, Aramaki Aza Aoba, Aoba‐ku Sendai Miyagi 980‐8579 Japan
1 shared publication - Hiroaki Kumano
Waseda University
1 shared publication - Kaede Watanabe
Faculty of Science and Technology, Seikei University, 3-3-1 Kichijoji-kitamachi, Musashino, Tokyo 180-8633, Japan
1 shared publication
Latest Publications
- Open Access
- 9 October 2016
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 13 (10) , 994
Correlation between Odor Concentration and Volatile Organic Compounds (VOC) Composition of Environmental Tobacco Smoke (ETS)
We examined the correlation between the odor concentration and the chemical composition of environmental tobacco smoke (ETS). Three types of ETS samples were prepared: secondhand smoke (SHS), thirdhand smoke (THS), and field ETS samples from an outside smoking area. The odor concentrations of the ETS, SHS, and THS samples were determined by the triangle-odor-bag method, and the chemical compositions were determined by proton transfer mass spectrometry. The odor concentration of the SHS samples was three or four orders of magnitude higher than that of the field ETS samples, and three orders of magnitude higher than that of the THS samples. The concentration ratios of the constituent chemicals in THS to those in SHS were about 10−4, corresponding to the ratio of the odor concentration. The concentration ratios of the constituent chemicals in the field ETS samples were much lower than the ratios of the odor concentrations. This suggests that the main contributing components to the odor of the field ETS samples are different from those in SHS and THS. The main contributors of the odor in the field ETS samples could be acetaldehyde, acetonitrile, acetic acid, and other unknown components with a mass-to-charge ratio (m/z) of 39 and 43.
- 9 October 2016
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 13 (10) , 994
Open AccessCorrelation between Odor Concentration and Volatile Organic Compounds (VOC) Composition of Environmental Tobacco Smoke (ETS)
We examined the correlation between the odor concentration and the chemical composition of environmental tobacco smoke (ETS). Three types of ETS samples were prepared: secondhand smoke (SHS), thirdhand smoke (THS), and field ETS samples from an outside smoking area. The odor concentrations of the ETS, SHS, and THS samples were determined by the triangle-odor-bag method, and the chemical compositions were determined by proton transfer mass spectrometry. The odor concentration of the SHS samples was three or four orders of magnitude higher than that of the field ETS samples, and three orders of magnitude higher than that of the THS samples. The concentration ratios of the constituent chemicals in THS to those in SHS were about 10−4, corresponding to the ratio of the odor concentration. The concentration ratios of the constituent chemicals in the field ETS samples were much lower than the ratios of the odor concentrations. This suggests that the main contributing components to the odor of the field ETS samples are different from those in SHS and THS. The main contributors of the odor in the field ETS samples could be acetaldehyde, acetonitrile, acetic acid, and other unknown components with a mass-to-charge ratio (m/z) of 39 and 43.
- Open Access
- 21 July 2016
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 13 (7) , 736
Measurements of Volatile Organic Compounds in a Newly Built Daycare Center
We measured temporal changes in concentrations of total volatile organic compounds (TVOCs) and individual volatile organic compounds in a newly built daycare center. The temporal changes of the TVOC concentrations were monitored with a photo ionization detector (PID), and indoor air was sampled and analyzed by Gas Chromatography/Mass Spectrometry (GC/MS) and high performance liquid chromatography (HPLC) to determine the concentrations of the constituent VOCs. The measurements were performed just after completion of the building and again 3 months after completion. The TVOC concentration exceeded 1000 µg·m−3 for all the sampling locations just after completion of building, and decreased almost one tenth after 3 months, to below the guideline values of the TVOC in Japan at 400 µg·m−3. The concentrations of the target VOCs of which the indoor concentrations are regulated in Japan were below the guideline values for all the cases. The air-exchange rates were determined based on the temporal changes of the TVOC concentrations, and it was found that the countermeasure to increase the air exchange rate successfully decrease the TVOC concentration level in the rooms.
- 21 July 2016
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 13 (7) , 736
Open AccessMeasurements of Volatile Organic Compounds in a Newly Built Daycare Center
We measured temporal changes in concentrations of total volatile organic compounds (TVOCs) and individual volatile organic compounds in a newly built daycare center. The temporal changes of the TVOC concentrations were monitored with a photo ionization detector (PID), and indoor air was sampled and analyzed by Gas Chromatography/Mass Spectrometry (GC/MS) and high performance liquid chromatography (HPLC) to determine the concentrations of the constituent VOCs. The measurements were performed just after completion of the building and again 3 months after completion. The TVOC concentration exceeded 1000 µg·m−3 for all the sampling locations just after completion of building, and decreased almost one tenth after 3 months, to below the guideline values of the TVOC in Japan at 400 µg·m−3. The concentrations of the target VOCs of which the indoor concentrations are regulated in Japan were below the guideline values for all the cases. The air-exchange rates were determined based on the temporal changes of the TVOC concentrations, and it was found that the countermeasure to increase the air exchange rate successfully decrease the TVOC concentration level in the rooms.
- Open Access
- 5 October 2015
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 12 (10) , 12446-12465
In-situ Real-Time Monitoring of Volatile Organic Compound Exposure and Heart Rate Variability for Patients with Multiple Chemical Sensitivity
In-situ real-time monitoring of volatile organic compound (VOC) exposure and heart rate variability (HRV) were conducted for eight multiple chemical sensitivity (MCS) patients using a VOC monitor, a Holter monitor, and a time-activity questionnaire for 24 h to identify the relationship between VOC exposure, biological effects, and subjective symptoms in actual life. The results revealed no significantly different parameters for averaged values such as VOC concentration, HF (high frequency), and LF (low frequency) to HF ratio compared with previous data from healthy subjects (Int. J. Environ. Res. Public Health 2010, 7, 4127–4138). Significant negative correlations for four subjects were observed between HF and amounts of VOC change. These results suggest that some patients show inhibition of parasympathetic activities along with VOC exposure as observed in healthy subjects. Comparing the parameters during subjective symptoms and normal condition, VOC concentration and/or VOC change were high except for one subject. HF values were low for five subjects during subjective symptoms. Examining the time-series data for VOC exposure and HF of each subject showed that the subjective symptoms, VOC exposure, and HF seemed well related in some symptoms. Based on these characteristics, prevention measures of symptoms for each subject may be proposed.
- 5 October 2015
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 12 (10) , 12446-12465
Open AccessIn-situ Real-Time Monitoring of Volatile Organic Compound Exposure and Heart Rate Variability for Patients with Multiple Chemical Sensitivity
In-situ real-time monitoring of volatile organic compound (VOC) exposure and heart rate variability (HRV) were conducted for eight multiple chemical sensitivity (MCS) patients using a VOC monitor, a Holter monitor, and a time-activity questionnaire for 24 h to identify the relationship between VOC exposure, biological effects, and subjective symptoms in actual life. The results revealed no significantly different parameters for averaged values such as VOC concentration, HF (high frequency), and LF (low frequency) to HF ratio compared with previous data from healthy subjects (Int. J. Environ. Res. Public Health 2010, 7, 4127–4138). Significant negative correlations for four subjects were observed between HF and amounts of VOC change. These results suggest that some patients show inhibition of parasympathetic activities along with VOC exposure as observed in healthy subjects. Comparing the parameters during subjective symptoms and normal condition, VOC concentration and/or VOC change were high except for one subject. HF values were low for five subjects during subjective symptoms. Examining the time-series data for VOC exposure and HF of each subject showed that the subjective symptoms, VOC exposure, and HF seemed well related in some symptoms. Based on these characteristics, prevention measures of symptoms for each subject may be proposed.
- Open Access
- 10 March 2015
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 12 (3) , 2950-2966
Optimized Arrangement of Constant Ambient Air Monitoring Stations in the Kanto Region of Japan
Continuous ambient air monitoring systems have been introduced worldwide. However, such monitoring forces autonomous communities to bear a significant financial burden. Thus, it is important to identify pollutant-monitoring stations that are less efficient, while minimizing loss of data quality and mitigating effects on the determination of spatiotemporal trends of pollutants. This study describes a procedure for optimizing a constant ambient air monitoring system in the Kanto region of Japan. Constant ambient air monitoring stations in the area were topologically classified into four groups by cluster analysis and principle component analysis. Then, air pollution characteristics in each area were reviewed using concentration contour maps and average pollution concentrations. We then introduced three simple criteria to reduce the number of monitoring stations: (1) retain the monitoring station if there were similarities between its data and average data of the group to which it belongs; (2) retain the station if its data showed higher concentrations; and (3) retain the station if the monitored concentration levels had an increasing trend. With this procedure, the total number of air monitoring stations in suburban and urban areas was reduced by 36.5%. The introduction of three new types of monitoring stations is proposed, namely, mobile, for local non-methane hydrocarbon pollution, and Ox-prioritized.
- 10 March 2015
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 12 (3) , 2950-2966
Open AccessOptimized Arrangement of Constant Ambient Air Monitoring Stations in the Kanto Region of Japan
Continuous ambient air monitoring systems have been introduced worldwide. However, such monitoring forces autonomous communities to bear a significant financial burden. Thus, it is important to identify pollutant-monitoring stations that are less efficient, while minimizing loss of data quality and mitigating effects on the determination of spatiotemporal trends of pollutants. This study describes a procedure for optimizing a constant ambient air monitoring system in the Kanto region of Japan. Constant ambient air monitoring stations in the area were topologically classified into four groups by cluster analysis and principle component analysis. Then, air pollution characteristics in each area were reviewed using concentration contour maps and average pollution concentrations. We then introduced three simple criteria to reduce the number of monitoring stations: (1) retain the monitoring station if there were similarities between its data and average data of the group to which it belongs; (2) retain the station if its data showed higher concentrations; and (3) retain the station if the monitored concentration levels had an increasing trend. With this procedure, the total number of air monitoring stations in suburban and urban areas was reduced by 36.5%. The introduction of three new types of monitoring stations is proposed, namely, mobile, for local non-methane hydrocarbon pollution, and Ox-prioritized.